OMRON D4BS-3AFS

Safety-door Switch
D4BS
CSM_D4BS_DS_E_3_1
The Special Operation Key Activates a Direct
Opening Mechanism to Open the Contacts
and Shut Off Control Circuits when Protective
Doors Are Opened on Machine Tools or Other
Equipment
Note: Contact your sales representative for details
on models with safety standard certification.
• Conforms to EN (TÜV) standards corresponding to the CE marking.
• Certified by UL and CSA standards.
• The Switch contact is opened by a direct opening mechanism (NC
contacts only) when the protective cover is opened. The EN-certified
direct opening mechanism is indicated by
on the Switch.
• Malfunctions and false operation prevented by special Operation Key.
• Wide temperature range specifications: −40 to 80°C.
• Degree of protection of the switch box: IP67 (EN60947-5-1).
• Series includes models with gold-plated contacts for handling the
microload range.
Be sure to read the “Safety Precautions” on page 7 and the
“Precautions for All Safety Door Switches”.
Model Number Structure
Model Number Legend
Switch
D4BS S
1
2
Operation Key
D4BS - K
3
1
1. Conduit
1: PG13.5 (1 conduit)
2: G1/2 (1 conduit)
3: 1/2-14NPT (1 conduit)
4: M20 (1 conduit)
5: PG13.5 (3-conduit)
6: G1/2 (3-conduit)
7: 1/2-14NPT (3-conduit)
8: M20 (2-conduit)
2. Built-in Switch
1. Operation Key Type
5: 1NC/1NO (slow-action)
1: Horizontal mounting
6: 1NC/NO (slow-action), gold-plated contacts
2: Vertical mounting
A: 2NC (slow-action)
3: Adjustable mounting (Horizontal)
B: 2NC (slow-action), gold-plated contacts
Note: An order for the head part or the switch
3. Head Mounting Direction
part alone cannot be accepted. (The
F: Four mounting directions
Operation Key is sold separately.)
possible (front-side mounting
at shipping)
Ordering Information
List of Models
Switches (Operation Keys are sold separately.)
: Models with certified direct opening contacts.
Consult with your OMRON representative when ordering any models that are not listed in this table.
Type
Mounting direction
1-conduit
Front-side
mounting
3-conduit
Conduit size
1NC/1NO (Slow-action)
2NC (Slow-action)
Pg13.5
D4BS-15FS
D4BS-1AFS
G1/2
D4BS-25FS
D4BS-2AFS
1/2–14NPT
D4BS-35FS
D4BS-3AFS
M20
D4BS-45FS
D4BS-4AFS
Pg13.5
D4BS-55FS
D4BS-5AFS
G1/2
D4BS-65FS
D4BS-6AFS
1/2–14NPT
D4BS-75FS
D4BS-7AFS
M20
D4BS-85FS
D4BS-8AFS
1
D4BS
Operation Keys
Type
Model
Horizontal mounting
D4BS-K1
Vertical mounting
D4BS-K2
Adjustable mounting
(Horizontal)
D4BS-K3
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
•
•
•
•
Certified Standards
Machinery Directive
Low Voltage Directive
EN50041
EN1088
Certification body
Standard
TÜV Rheinland
EN60947-5-1
(certified direct
opening)
GS-ET-15
UL
UL508
CSA
CSA C22.2 No. 14
CQC (CCC)
GB14048.5
File No.
J50084815
E76675
LR45746
2003010305073833
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Item
Utilization category
AC-15
Rated operating current (Ie)
2A
Rated operating voltage (Ue)
400 V
Note: Use a 10 A fuse type a gI or gG that conforms to IEC60269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14) (A600)
Rated voltage
Carry current
120 VAC
240 VAC
480 VAC
600 VAC
10 A
Current (A)
Volt-amperes (VA)
Make
Break
60
6
30
3
15
1.5
12
1.2
Make
Break
7,200
720
2
D4BS
Characteristics
Degree of protection *1
Durability *2
IP67 (EN60947-5-1)
Mechanical
1,000,000 operations min.
Electrical
500,000 operations min. (10 A resistive load at 250 VAC)
Operating speed
0.1 m/s to 0.5 m/s
Operating frequency
30 operations/minute max.
Direct opening force *3
19.61 N min. (EN60947-5-1)
Direct opening travel *3
20 mm min. (EN60947-5-1)
Contact resistance
25 mΩ max.
Rated insulation voltage (Ui)
600 V (EN60947-5-1)
Rated frequency
50/60 Hz
Protection against electric shock
Class I (with ground terminal)
Pollution degree (operating environment)
3 (EN60947-5-1)
Between terminals of
same polarity
Impulse withstand
voltage
(EN60947-5-1)
Between terminals of
different polarity
4 kV
Between each
terminal and ground
Insulation resistance
100 MΩ min. (at 500 VDC) between terminals of same or different polarity, between each
terminal and ground, and between each terminal and non-current-carrying metal part
Contact gap
2 × 2 mm min.
Vibration
resistance
Shock resistance
Malfunction
10 to 500 Hz, 0.65 mm single amplitude
Destruction
1,000 m/s2 min. (IEC68-2-27)
Malfunction
300 m/s2 min. (IEC68-2-27)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 20 A (EN60947-5-1)
Ambient operating temperature
−40 to 80°C (with no icing)
Ambient operating humidity
95% max.
Weight
Approx. 285 g (D4BS-15FS)
Note: The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand. Although the switch box is protected from dust, oil, or water penetration, do not use the
D4BS in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning
may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. Contact your OMRON sales representative
for more detailed information on other operating environments.
*3. These figures are minimum requirements for safe operation.
3
D4BS
Structure and Nomenclature
Structure
Head
The switch head is coated with
easy-to-see red paint. The mounting
direction of the switch head can be varied
to any of the four directions.
Operation Key
D4BS's exclusive-use Operation Key is provided
to assure accurate switching operation.
Seal Ring (NBR)
Set Zone Mark
A triangular Set Zone
Mark makes it easy to
adjust the operating
position when inserting
the Operation Key.
Oil Seal (NBR)
The operation plunger employs an oil
seal, with which the switch box meets
the requirements of IP67.
Built-in Switch
A shearing force contact separating mechanism (NC
contact) is employed, which positively pulls apart the
contacts from each other by using shearing force if
any abnormality such as contact welding should occur
in the contact area.
There is a difference in level between the NC and NO
terminal, which assures easy wiring.
Seal Packing (NBR)
Conduit Opening
Refer to the following list.
Ground Terminal Screw
A ground terminal is provided to
improve safety. (Built into the
Unit.)
Box
1-conduit
box
3-conduit
box
Pg13.5
Yes
Yes
G1/2
Yes
Yes
1/2-14NPT
Yes
Yes
Size
Contact Form (Diagrams Show State with Key Inserted)
Model
Contact form
Operating pattern
Zb
D4BS-@5@S
1NC/1NO
11
12
23
24
2NC
Stroke
Operation Key
insertion completion
position
ON
11
12
21
22
Stroke
Operation Key
insertion completion
position
ON
Extraction
completion
position
Only NC contact 11-12
has a certified direct
opening mechanism.
Terminals 11-12 and
23-24 can be used as
unlike poles.
Extraction
completion
position
11 - 12
21 - 22
Zb
D4BS-@A@S
11 - 12
23 - 24
Remarks
NC contacts 11-12 and
21-22 have a certified
direct opening
mechanism.
Terminals 11-12 and
21-22 can be used as
unlike poles.
Note: The terminal numbers are in accordance with EN50013, and the contact symbols are in accordance with IEC60947-5-1.
4
D4BS
Dimensions and Operating Characteristics
(Unit: mm)
Switches
1-conduit
D4BS-1@@S
D4BS-2@@S
D4BS-3@@S
31.4
17
41
16
Four, M3.5 head
clamping screws
7
Red
34.5
35
Two, 5.3 dia.
mounting holes
Two, M4 cover
clamping screws
(111.5)
60±0.2
7.3
Cover
15
31.5
43
31.4
17
41
16
7
*
Four, M3.5 head
clamping screws
34.5
5.3
Red
(110)
30±0.2
66.4
50.9
51
28.5
57
63
Key insertion force
Key extraction force
19.61 N max.
19.61 N max.
Pretravel (PT)
40+1
0
3-conduit
D4BS-5@@S
D4BS-6@@S
D4BS-7@@S
D4BS-1@@S
D4BS-2@@S
D4BS-3@@S
10±5 mm
77
5.3
30±0.1
8
Model
Operating
characteristics
Six, 5.3 dia.
mounting holes
Four, M3.5 x 10 cover
clamping screws
Two caps
Cover
23 mm min.
Direct opening force
Direct opening stroke
19.61 N min.
20 mm min.
Model
Operating
characteristics
D4BS-5@@S
D4BS-6@@S
D4BS-7@@S
Key insertion force
Key extraction force
19.61 N max.
19.61 N max.
Pretravel (PT)
71.4 75.4
17.2
*
Total travel
35.7
38.3
dia.
Two, 5+0.15
−0
holes (6 mm deep)
10±5 mm
Total travel
23 mm min.
Direct opening force
Direct opening stroke
19.61 N min.
20 mm min.
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application.
* The conduit thread varies with the model as follows:
D4BS-1@@S, D4BS-5@@S: Pg 13.5
D4BS-2@@S, D4BS-6@@S: G1/2
D4BS-3@@S, D4BS-7@@S: 1/2-14NPT
5
D4BS
Operation Keys
D4BS-K3
D4BS-K1
78.7
40.7
Black
20
12
Black
26
7.3 15
15
36
5.3 5.3
Two, 2.65R
7.5
2.5
40
12 20
15
20
11.4
Red
5
18°
4 dia.
26
18°
D4BS-K2
53.7
13
5.3 × 7.3 mounting long hole
40
30
Black
26
40
15
52.4
5.3 12
19.5
(37.8)
5
4 dia.
7.5
M4 Allen-head bolt
20
11.4
2.5
11.4
30
36
(80.7)
36
Two, 5.3 dia.
mounting hole
17.5
34.6
5
4 dia.
2.5
With Operation Key Inserted
D4BS-1@@S + D4BS-K1
D4BS-2@@S + D4BS-K1
D4BS-3@@S + D4BS-K1
D4BS-1@@S + D4BS-K2
D4BS-2@@S + D4BS-K2
D4BS-3@@S + D4BS-K2
Red
Red
Red
Operation Key insertion
radius in horizontal
direction: R ≥ 150
Operation Key insertion
radius in horizontal
direction: R ≥ 1200
Operation Key insertion
radius in horizontal
direction: R ≥ 1200
53.5 min.
58 max.
D4BS-1@@S + D4BS-K3
D4BS-2@@S + D4BS-K3
D4BS-3@@S + D4BS-K3
54.5 min.
59 max.
81.5 min.
86 max.
(20±0.15)
(40±0.15)
(41)
(41)
(12)
53.5 min.
58 max.
(41)
(13)
Operation Key insertion
radius in vertical
direction: R ≥ 1000
(30±0.15)
Operation Key insertion
radius in vertical
direction: R ≥ 1000
54.5 min.
59 max.
81.5 min.
86 max.
(20±0.15)
(41)
(41)
(35)
(40)
Operation Key insertion
radius in vertical
direction: R ≥ 1000
(41)
(35)
(35)
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
6
D4BS
Safety Precautions
Refer to the “Precautions for All Switches” and “Precautions for All Safety Door Switches” .
Precautions for Safe Use
• Do not use the Switch submersed in oil or water or in locations
continuously subject to splashes of oil or water. Doing so may
result in oil or water entering the Switch. (The IP67 degree of
protection of the Switch specifies the amount of water penetration
after the Switch is submerged in water for a certain period of time.)
• Always attach the cover after completing wiring and before using
the Switch. Also, do not turn ON the Switch with the cover open.
Doing so may result in electric shock.
Stopper Installation
Do not use a Switch as a stopper.
Be sure to install a stopper as shown in the following illustration when
mounting the Switch and adjust the stopper so that the Operation Key
is within the setting zone.
Do not subject the Switch to a shock that exceeds the Switch's shock
resistance of 1,000 m/s2.
Stopper
Correct
Extra space
Incorrect
Precautions for Correct Use
Appropriate Tightening Torque
Loose screws may result in malfunction. Tighten the screws to the
specified torques.
Type
Appropriate tightening
torque
M3.5 terminal screw (including ground
terminal screw)
0.59 to 0.78 N·m
Cover mounting screw *1
1.18 to 1.37 N·m
Head mounting screw
0.78 to 0.98 N·m
M5 body mounting screw *2
4.90 to 5.88 N·m
Operation Key mounting screw
2.35 to 2.75 N·m
Connector
1.77 to 2.16 N·m
Cap screw
1.27 to 1.67 N·m
*1. Apply a torque of 0.78 to 0.88 N·m if the D4BS is a three-conduit
model.
*2. Apply a torque of 4.90 to 5.88 N·m for an Allen-head bolt. For a
pan head screw, apply a torque of 2.35 to 2.75 N·m.
Mounting Dimensions (M5)
Standard Model
Switch
Set zone
Three-conduit Model
Correct
30
40
42
Incorrect
59.3±0.1
60
Studs
27±0.1
30
5 −0.05
−0.15 dia. holes, max. height: 5
Mounting hole
Mounting side
Insertion hole for stud
−0.05
dia. holes, max. height: 5
5−0.15
With a Three-conduit Model, the Switch can be mounted more
securely at four points rather than with just two mounting holes, i.e.,
by adding two studs at the bottom of the switch, each of which is 5 mm
maximum in height and 5 −0.05
−0.15 mm in diameter as shown below.
Mounting Hole Dimensions for Operation Keys
Horizontal
Mounting
Vertical
Mounting
Adjustable
Mounting
Two, M5
Two, M5
20±0.1
40±0.1
Two, M5
30±0.1
Use spring washers to mount the Switch and Operation key, and
tighten the screws to a suitable torque.
To ensure safety, use screws that cannot be easily removed or
another means to prevent the Switch and Operation Key from easily
being removed.
7
D4BS
Operation Key
Wiring
Make sure that the Operation Key can be inserted properly with
a tolerance of ±0.5 mm in the upward, downward, left, or right
direction. Otherwise the D4BS may soon become damaged due to
misalignment.
Do not connect the lead wires directly to the terminals. Connect the
lead wires through insulation tubes and M3.5 round crimp terminals.
Tighten each terminal screw within the proper torque range.
The proper lead wire is AWG20 to AWG14 (0.5 to 2.5 mm2) in size.
Observe the specified insertion radius for the Operation Key and
insert it in a direction perpendicular to the key hole. Do not use the
D4BL operation key.
Incorrect
±0.5 or greater
dz dia.:
D dia.:
B:
L:
F:
I:
Incorrect
±0.5 or greater
3.7
4.5
7.0
20.2
7.7
9.0 (mm)
D dia.
dz dia.
Wire using the methods shown below so that the crimp terminals are
not caught on the case or cover. Otherwise it may not be possible to
mount the cover completely and malfunctions may occur.
Changes in Head Mounting Direction
By removing the screws on the four corners of the head, the head can
be reset in any of four directions. The head direction can be changed
with or without the Operation Key inserted in the head. Make sure that
no foreign materials enter through the head and that the head is
tightened securely within the proper torque range.
Incorrect
Correct
Terminal screw
Crimp terminal
Incorrect
Correct
Terminal screw
Terminal screw
Crimp
terminal
Cover
Cover
Casing
Casing
Crimp terminal
Correct
Incorrect
Crimp terminal
Crimp terminal
Conduit Opening
• Tighten the connector to a suitable torque.
• Excessive tightening torque may damage the casing.
• When using 1/2-14NPT conduits, apply sealing tape between the
connector and conduit opening to maintain the degree of protection
(IP67) of the Switch.
• If using a Pg13.5 conduit, use an ABS-08 Pg13.5 connector or an
ABS-12 Pg13.5 connector (manufactured by Nippon Flex).
• Use a connector (SC Series, sold separately) suitable for the outer
diameter of the cable.
• When wiring a 3-conduit model, securely tighten the cap screw
provided for unused conduit openings.
8
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2009.3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2009 All Right Reserved.