勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Safety-Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors H Conforms to EN (TÜV) standards. (positive H H H H H opening mechanism is indicated on the switch) Wide standard operating temperature range: --30 to 70°C Double-insulation structure (with mark) requires no grounding terminals Five-direction Operation Key Approved by UL, CSA, BIA and SUVA standards Standards and EC Directives: E • Conforms to the following EC Directives: Machinery Directive Low Voltage Directive EN50047 EN1088 H Approved Standards Agency Standard File No. TÜV Rheinland EN60947-5-1 R9551708 (Positive opening: approved) UL (see note) UL508 CSA C22.2 No.14 E76675 BIA GS-ET-15 1-conduit: 9509915 2-conduit: 9509913 SUVA SUVA 1-conduit: 6010Z 2-conduit: 6011Z Note: CSA C22.2 No. 14 compliance was verified and approved ). by UL (Marked with 2 u 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Ordering Information J MODEL NUMBER LEGEND Operation Key Switch D4DS-jjjS 1 1. 2. 2 D4DS-Kj 3 1 Conduit size/type 1: Pg13.5 (1-conduit, European type) 2: G1/2 (1-conduit, Japanese type) 3: 1/2-14NPT (1-conduit, North American type) 5: Pg13.5 (2-conduit) (1-conduit, European type) 6: G1/2 (2-conduit Japanese type) Built-in Switch 5: 1NC/1NO (Slow-action) A: 2NC (Slow-action) 3. Head Mounting Direction F: Four mounting directions possible (Front-side mounting at shipping) 1. Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) 5: Adjustable mounting (Horizontal/ Vertical) Note: An order for the head part or the switch part alone cannot be accepted. The Operation Key is sold separately. J SWITCHES Description Appearance Part number Conduit size/type 1-conduit 2-conduit 1NC/1NO (Slow-action) 2NC (Slow-action) Pg13.5 (European) D4DS-15FS D4DS-1AFS G1/2 (Japanese) D4DS-25FS D4DS-2AFS 1/2-14NPT (North American) D4DS-35FS D4DS-3AFS Pg13.5 (European) D4DS-55FS D4DS-5AFS G1/2 (Japanese) D4DS-65FS D4DS-6AFS J OPERATION KEYS (ORDER SEPARATELY) Type Part number Horizontal mounting D4DS-K1 Vertical mounting D4DS-K2 Adjustable mounting (Horizontal) D4DS-K3 Adjustable mounting (Horizontal/Vertical) D4DS-K5 3 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Specifications J APPROVED STANDARD RATINGS TÜV (EN60947-5-1) Utilization category AC-15 Rated operating current (Ie) 2A Rated operating voltage (Ue) 400 V Note: Use a 10-A fuse type gl or gG as a short-circuit protection device that conforms to IEC269. UL (UL508/CSA C22.2 No.14) A600 Rated voltage Carryy current 120 VAC 10 A Current Volt-amperes Make Break Make Break 60 A 6A 7,200 VA 720 VA 240 VAC 30 A 3A 480 VAC 15 A 1.5 A 600 VAC 12 A 1.2 A J CHARACTERISTICS Degree of protection (see note 1) IP65 (EN60947-5-1) Life expectancy (see note 2) Mechanical: 1,000,000 operations min. Electrical: 150,000 operations min. Operating speed 0.1 m/s to 0.5 m/s Contact gap 2 x 2.0 mm min. Operating frequency 30 operations/minute min. Positive opening force (see note 3) 58.84 N min. Positive opening travel (see note 3) 10 mm min. Insulation resistance 100 MΩ min. (at 500 VDC) between terminals of same polarity, between terminals of different polarity, between each terminal and ground, and between each terminal and non-current-carrying metal part Contact resistance 25 mΩ max. (initial value) Dielectric strength Uimp 4 kV between terminals of same polarity, between terminals of different polarity, and between each terminal and non-current-carrying metal part (EN60947-5-1) Rated insulation voltage (Ui) 400 V (EN60947-5-1) Conditional short-circuit current 100 A (EN60947-5-1) Short-circuit protective device (SCPD) 10 A, fuse type gI or gG (IEC269) Switching overvoltage 1,500 V max. (EN60947-5-1) Pollution degree (operating environment) 3 (EN60947-5-1) Conventional enclosed thermal current (Ithe) 10 A (EN60947-5-1) Protection against electric shock Class II (double insulation) Vibration resistance Malfunction: 10 to 500 Hz, 0.65-mm single amplitude with an imposed acceleration of 100 m/s2 max. Shock resistance Destruction: 1,000 m/s2 min. Malfunction: 300 m/s2 min. Ambient temperature Operating: --30°C to 70°C (with no icing) Ambient humidity Operating: 95% max. Weight Approx. 76 g (for D4DS-15FS) Note: 1. Although the Switch casing resists dust, oil, and water, make sure that the keyhole on the head is free from dust, oil, water, and chemical, or the D4DS may wear out, break, or malfunction. 2. Life expectancy values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments. 3. These figures are minimum requirements for safe operation. 4 勝特力科技 886-3-5753170 百年電子 86-755-83289224 Http://www.100y.com.tw J OPERATING CHARACTERISTICS 1-Conduit/2-Conduit Models Model D4DS-jjjS Operating force (extraction) 14.71 N Release force (insertion) 29.42 N Pretravel 6±3 mm Total travel (reference value) 28 mm Min. positive opening force (see note) 58.84 N Min. positive opening stroke (see note) 10 mm Note: Make sure that the positive opening stroke is at least 16 mm in order to use the D4DS safely. Nomenclature Head The head can be mounted in four directions. The Operation Key can be inserted in five directions including the downward direction. Operation Key The dedicated key prevents operational mistakes and forcibly separates the contacts. Oil Seal The plunger has an O ring. The switch casing ensures IP65 (except the keyhole, which ensures IP00). Use the D4DS in places where the keyhole is free from oil and metal chips. Built-in Switch Has a positive opening mechanism which forcibly separates the NC contacts even if they are welded. The built-in switch incorporates a pair each of NC contacts and NO contacts or two pairs of NC contacts. Cover The cover, with a hinge on its lower part, can be opened by removing the screw of the cover, which ensures ease of maintenance and wiring. Conduit Wide switch variations. Pg13.5: 1-conduit, 2-conduit models G1/2: 1-conduit, 2-conduit models 1/2-14NPT: 1-conduit models Note: The housing and head of the D4DS are made of synthetic resin. If high mechanical durability is required, use the D4BS Safety Door Switch. 5 D4DS 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Operation J CONTACT FORM (DIAGRAMS SHOW STATE WITH KEY INSERTED) Model Contact D4DS-j5jS 1NC/1NO Diagrams Zb 11 12 Remarks Only NC contact 11-12 has an approved positive opening mechanism. The terminals 11-12 and 23-24 can be used as unlike poles. 11 - 12 23 - 24 23 24 Stroke Operation Key insertion completion position Pull-out completion position ON D4DS-jAjS 2NC Zb 11 12 NC contacts 11-12 and 21-22 have an approved positive opening mechanism. The terminals 11-12 and 23-24 can be used as unlike poles. 11 - 12 21 - 22 21 Stroke 22 Operation Key insertion completion position Pull-out completion position ON Note: Terminals are numbered according to EN50013 and contacts are marked according to EN60947-5-1. J POSITIVE OPENING MECHANISM 2NC Contact (Slow-Action) 1NC/1NO Contact (Slow-Action) Fixed contact (NC) Fixed contact (NC) Contact spring Contact spring Movable contact Return spring Movable contact Plunger Fixed contact (NO) Return spring Plunger Only the NC contacts have a positive opening function. When metal deposition occurs, the contacts are separated from each other by pushing in the plunger. Conforms to EN60947-5-1 Positive Opening Both NC contacts incorporate a positive opening function. When metal deposition occurs, the contacts are separated from each other by pushing in the plunger. Conforms to EN60947-5-1 Positive Opening Note: The switches are marked with indicating approval for the positive opening mechanism. 6 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Dimensions Unit: mm (inch) Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. The conduit thread varies with the model as follows: Conduit thread Model Pg13.5 D4DS-1jjS/-5jjS G1/2 D4DS-2jjS/-6jjS 1/2-14NPT D4DS-3jjS J SWITCHES 1-Conduit Models D4DS-1jjS D4DS-2jjS D4DS-3jjS Red 30 x 30 Black Two, 4 +0.15 0 dia. holes depth: 5 R2.15±0.05 mounting holes Conduit opening 2-Conduit Models D4DS-5jjS D4DS-6jjS Red Black 30 x 30 R2.15±0.05 mounting holes 56 max. 7 Conduit opening Cap Two, 4 +0.15 dia. holes 0 depth: 5 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw J OPERATION KEYS Horizontal Mounting D4DS-K1 Vertical Mounting D4DS-K2 Adjustable Mounting (Horizontal) D4DS-K3 Black Four, R2.15 9 dia. 4.5 dia. 8 dia. Four, R2.15 Adjustable Mounting (Horizontal/Vertical) D4DS-K5 Black Mounting Holes 18° ± 9 0.1 41±0.1 43±0.1 Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified. 8 Two, M4 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw J WITH OPERATION KEY INSERTED Horizontal Mounting D4DS-1jjS + D4DS-K1 D4DS-2jjS + D4DS-K1 D4DS-3jjS + D4DS-K1 D4DS-5jjS + D4DS-K1 D4DS-6jjS + D4DS-K1 Red Vertical Mounting D4DS-1jjS + D4DS-K2 D4DS-2jjS + D4DS-K2 D4DS-3jjS + D4DS-K2 D4DS-5jjS + D4DS-K2 D4DS-6jjS + D4DS-K2 44 to 46.5 Key insertion face Horizontal key insertion radius R ≧ 200 Red Black 44 to 46.5 Key insertion face Black Permissible difference in center lines between the Operation Key and key hole. 44 to 46.5 Horizontal key Key insertion face insertion radius R ≧ 200 Horizontal key insertion radius R ≧ 200 Permissible difference in center lines between the Operation Key and key hole. 44 to 46.5 Horizontal key Key insertion face insertion radius R ≧ 200 Permissible difference in center lines between the Operation Key and key hole. Permissible difference in center lines between the Operation Key and key hole. Adjustable Mounting (Horizontal) Adjustable Mounting (Horizontal/Vertical) D4DS-1jjS + D4DS-K3 D4DS-2jjS + D4DS-K3 D4DS-3jjS + D4DS-K3 D4DS-5jjS + D4DS-K3 D4DS-6jjS + D4DS-K3 D4DS-1jjS + D4DS-K5 D4DS-2jjS + D4DS-K5 D4DS-3jjS + D4DS-K5 D4DS-5jjS + D4DS-K5 D4DS-6jjS + D4DS-K5 51.9 to 54.4 Key insertion face Red 44 to 46.5 Key insertion face Red Horizontal key insertion radius R ≧ 200 Black Black 44 to 46.5 Key insertion face Horizontal key insertion radius R ≧ 50 Permissible difference in center lines between the Operation Key and key hole. Horizontal key insertion radius R ≧ 200 51.9 to 54.4 Key insertion face Permissible difference in center lines between the Operation Key and key hole. Permissible difference in center lines between the Operation Key and key hole. Horizontal key insertion radius R ≧ 200 Permissible difference in center lines between the Operation Key and key hole. 9 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Precautions ! CAUTION Do not remove the operation key from the door intentionally and insert it into the switch with the door open. The machine may start operating, and injury or death may be caused. Do not use metal connectors or conduits with this switch. Rigid connectors and conduits may damage the switch. The broken conduit hole may cause an electrical shock hazard. Install the operation key so that it will not hit the operator when the door is open. If the D4DS is to be used as a switch in an emergency stop circuit or in a safety circuit for preventing accidents resulting in injuries or deaths, use NC contacts with a forced release mechanism and set the D4DS so that it will operate in positive opening mode. For safety, install the Switch and the Operation Key using one-way rotational screws or other similar means to prevent them from easily coming off. Protect the D4DS with an appropriate cover and post a warning sign near the D4DS in order to ensure the safety of the door. To prevent the D4DS from damage due to circuit short-circuiting, connect a fuse with a breaking current 1.5 to 2 times larger than the rated current of the D4DS in series to the D4DS. J CORRECT USE Operating Environment Do not use the D4DS in the following environments, or the D4DS may malfunction. • • • • Locations subject to significant temperature fluctuations Humid locations where there is a risk of condensation Locations subject to significant vibrations Locations subject to metal chips, oils, and chemicals inside a protective door Operation Key Be sure to use a special Operation Key only. Do not operate the D4DS with anything other than the special Operation Key, or the D4DS may break or the safety of the system may not be maintained. Do not impose excessive force on the Operation Key inserted into the D4DS or drop the D4DS with the Operation Key inserted, or the Operation Key may deform or break. Excessive force If the D4DS is used under EN-approved conditions, use a gI or gG 10-A fuse approved by IEC269. Mount with a Stopper Be sure to mount the D4DS with a stopper as shown in the following illustration. Do not use the casing of the D4DS as a stopper. Be sure to install the stopper so that the space “a” will be a maximum of 3 mm. Drop Secure the Operation Key with screws so that the Operation Key cannot be removed easily. Stopper Refer to Dimensions for the mounting dimensions of the Operation Key and properly mount the Operation Key so that the position and angle will be correct. Make sure that the Operation Key can be inserted correctly with a tolerance of ±0.5 mm in the upward, downward, left, or right direction, or damage to the D4DS may occur. Switch ±1 min. ±1 min. 10 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Mounting J MOUNTING Switch Tightening Torque Two, M4 Allen-head bolts with washers must be used in order to mount the D4DS securely. To mount the D4DS more securely, prepare two, 4 --0.05/ --0.15 dia. protruding portions with 4.8 mm maximum in height each as shown below and support the D4DS at a total of four points. Be sure to tighten each screw to the appropriate tightening torque as shown below. 3 Mounting Dimensions with Protruding Portions Standard Model 5 4 1 2 6 4 --0.05 --0.15 dia. height, 4.8 max. Two-Conduit Model 7 4 --0.05 --0.15 dia. height, 4.8 max. No. Type Torque 1 Terminal screw 0.59 to 0.78 N S m 2 Cover mounting screw 0.78 to 0.88 N S m 3 Head mounting screw 0.78 to 0.88 N S m 4 M4 switch mounting bolt (see note 1) 0.49 to 0.69 N S m 5 Operation Key mounting screw 2.35 to 2.75 N S m 6 Connector 1.77 to 2.16 N S m 1.37 to 1.77 N S m (see note 2) 7 Cap screw 1.27 to 1.67 N S m Mounting hole Mounting surface Insertion hole for protrusions --0.05 4 --0.15 dia. height, 4.8 max. Note: 1. Tighten each screw with a washer and use the appropriate tightening torque. 2. This force range applies to 1/2-14NPT. 11 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Operation Key Mounting Dimensions Securing the Door Horizontal/Vertical Mounting D4DS-K1 or D4DS-K2 When the door is closed (with the Operation Key inserted), the door (or the Operation Key) may be pushed back across the set zone due to the door’s weight, the door cushion rubber, etc. If load is applied to the Operation Key, the door may fail to unlock. Secure the door with hooks so that it will remain within in the set zone. Two, M4 Set zone (0.5 to 3 mm) Adjustable Mounting (Horizontal) D4DS-K3 Two, M4 Operation Key Adjustable Mounting (Horizontal/Vertical) D4DS-K5 Changes in Head Mounting Direction 9 ± 0.1 By removing the screws on the four corners of the head, the head can be reset in any of four directions. When changing the head mounting direction, make sure that the Operation Key is in the head. 41±0.1 43±0.1 Two, M4 Make sure that no foreign materials penetrate through the mounting holes of the head. Internal screws of the head must not be removed, or the internal parts of the head may be lost or deformed. Wiring Do not connect lead wires directly to the terminals. Be sure to connect the lead wires through insulation tubes and crimp terminals., and tighten each terminal screw within an optimum torque range. The lead wires must be an AWG20 to AWG14 type (i.e., 0.5 to 25 mm2 thick). dz dia.: D dia.: B: L: F: I: 3.7 4.5 7.0 20.2 7.7 9.0 (mm) D dia. dz dia. 12 勝特力科技 886-3-5753170 百年電子 86-755-83289224 D4DS Http://www.100y.com.tw Conduit Opening Recommended Connector Tighten the connector to a torque of 1.8 to 2.2 N S m (1.37 to 1.77 N S m if it is a 1/2-14NPT). Excessive tightening torque may damage the casing. In order to continue satisfying IP65, apply sealing tape to the connector conduit. Size Manufacturer Model Suitable cable dia. G1/2 OMRON SC-6 7.5 to 9.0 mm LAPP (see note 1) ST-PF1/2 5360-1002 6.0 to 12.0 mm The diameter of the cable must be suited to the corresponding connector. Wire the crimp terminal as shown in the following diagram so that it will not come in contact with the case or cover. Correct Terminal screw Incorrect Ohm Electric OA-W1609 7.0 to 9.0 mm Pg13.5 LAPP (see note 1) ST13.5 5301-5030 5.0 to 12.0 mm 1/2-14NPT LAPP (see note 1) ST-NPT1/2 5301-6030 6.0 to 12.0 mm Note: 1. LAPP is a German manufacturer. 2. Ohm Denki is a Japanese manufacturer. Maintenance and Repairs The user must not maintain or repair equipment incorporating any D4DS model. Contact the manufacturer of the equipment for any maintenance or repairs required. Crimp terminal Crimp-style terminal Crimp-style terminal Properly attach the provided conduit cap to the unused conduit opening and securely tighten the cap screw within a torque range between 1.27 and 1.67 N S m when wiring the D4DS two-conduit model. 13