VECTRON 5116

Hi-Rel
VCXO
5116
Typical Applications
Features
Mil/Space Applications
Satellite Applications
Rad Hard Environments
9x14 J Leaded Surface Mount Package
4 Point Crystal Mount / Swept Quartz 3
Class S Screening IAW MIL-PRF-55310
100 krad Total Dose Radiation Tolerance 3
Nominal Frequency Range:
1 to 85 MHz
Operating Temperature Range
Parameter
Operating Temperature Range
Min
Max.
Units
-0
Typ
+70
°C
Condition
Ordering Code
C
-20
+70
°C
D
-40
+85
°C
F
Supply voltage (Vs)
Parameter
Min
Typ
Max.
Units
Supply voltage
4.75
5
5.25
VDC
15
mA
1.0 to 23.9 MHZ
20
mA
24 to 49.9 MHz
40
mA
50 to 85.0 MHz
3.465
VDC
6
mA
Current consumption (no load)
3.135
Supply voltage
3.3
Current consumption (no load)
Condition
Ordering Code
SV050
SV033
1.0 to 14.9 MHZ
8
mA
15.0 TO 39.9 MHz
12
mA
40.0 TO 59.9 MHz
16
mA
60.0 TO 85.0 MHz
Max.
Units
RF output
Parameter
Signal
Load
Min
Typ
Condition
ACMOS
15
Signal Level (Vol)
Signal Level (Voh)
50
pF
0.5
0.3
VDC
VDC
VDC
VDC
ns
ns
%
%
4.5
3.0
Rise and fall times for ACMOS
(measured 10% to 90%)
Duty cycle
10
5
55
60
45
40
Ordering Code
RFA
Vs= 5.0V and 15pF load
Vs=3.3V and 15pF load
Vs= 5.0V and 15pF load
Vs=3.3V and 15pF load
1.0 to 23.9 MHz
24.0 to 85.0 MHz
@ 50% Vs < 15 MHz
@ 50% Vs > 15 MHz
Frequency Tuning (EFC) 1
Parameter
Absolute Pull Range
Min
±30
Typ
Max.
10
15
%
4.5
3.0
VDC
VDC
±50
Linearity
Units
ppm
Condition
ppm
Tuning Slope
Ordering Code
AP030
AP050
Positive
Control Voltage Range
Vectron International
0.5
0.3
2.5
1.65
100 Watts Street
Mount Holly Springs PA 17065
t 717 486 3411
f 717 486 5920
with Vs=5.0VDC
with Vs=3.3VDC
www.vectron.com
9/5/06 SEM
1/3
Hi-Rel
VCXO
5116
Screening level
Parameter
Class S Screening
Class B Screening
Engineering Model
Condition
IAW MIL-PRF-55310
IAW MIL-PRF-55310
No Screening
Ordering Code
S
B
X
Additional parameters
Parameter
Phase Noise 2
(measured at 52 MHz)
Min
Typ
-60
-90
-120
-140
-145
<2
Weight
Max.
Units
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
g
Condition
10
100
1
10
100
Hz
Hz
kHz
kHz
kHz
Absolute Maximum Ratings
Parameter
Supply voltage (Vs)
Min
Operable temperature range
Storage temperature range
-55
-55
Typ
Max.
7.0
Units
V
+85
+125
°C
°C
Condition
Enclosure
Type A - ACMOS
Ordering Codes
A1 = 4 leads
5
T= Tinned J leads
X = No Tinning
4
Maximum
Height
Maximum
Stand-off
0.188 max
(4.77)
0.043 max
(1.09)
Pin Connections
1
2
3
4
Control Voltage
Case Ground
RF Output
Supply Voltage
Vectron International
100 Watts Street
Mount Holly Springs PA 17065
t 717 486 3411
f 717 486 5920
www.vectron.com
9/5/06 SEM
2/3
Hi-Rel
VCXO
5116
How to Order this Product: 6
Step 1
Use this worksheet to forward the following information to your factory representative (example follows):
Model
Operating
Temperature
Code
Supply
Voltage
Code
RF Output
Code
Frequency
Tuning
Code
Screening
Code
Package
Code
Tinning
Code
C5116
F
SV033
RFA
AP030
S
A1
T
Step 2
The factory representative will then respond with a Vectron Part Number in the following configuration:
Model
Package Code
Dash
Dash Number
C5116
[Customer Specified Package Code]
-
[Factory Generated 4 digit number]
Typical P/N: C5116A1-0001
Notes:
1 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control
voltage, load, temperature (25°C)
2 Phase noise degrades with increasing output frequency.
3 Flight models will be manufactured with swept quartz and Class S die; engineering models will be manufactured with cultured quartz
and commercial grade components.
4 When requested, leads tinned per Vectron International standard procedure (GR-37409)
5 Contact factory for other options.
6 Please be sure to specify nominal frequency.
Vectron International
100 Watts Street
Mount Holly Springs PA 17065
t 717 486 3411
f 717 486 5920
www.vectron.com
9/5/06 SEM
3/3