5616 5616 Data Sheet 26110 2-FUNCTION, 4-DIGIT LCD AUTOMOTIVE CLOCK The SCL5616HW is a 2-function digital automotive clock circuit. Fabricated on a single monolithic chip using silicon-gate CMOS PROM technology, it offers low cost, low power, and high reliability. It also includes digital frequency correction, stored in the internal nonvolatile memory, for easy adjustment of the oscillator nominal frequency. adge1 AM PM BACKPLANE b1 g2 f2 a2 2-FUNCTION, 4-DIGIT LCD AUTOMOTIVE CLOCK—PROGRAMMABLE b2 c1 COLON e2 g3 d2 f3 c2 ad3 e3 2040 x 3040 µm b3 U e4 f4 d4 D FEATURES P O R E C N O ■ Digital Tuning of Crystal Frequency ■ PROM for Storing Frequency Correction Information ■ 12 or 24 Hour Timekeeping Option ■ Flashing Colon ■ Two Switches Control All Setting Functions ■ High Noise Immunity ■ Internal Power-Up Reset Circuitry ■ Internal Voltage Regulation D E N U E N ER I T F N E O R C R S I O D F — a4 c4 S2 b4 SELECT S1 GROUND { OSC. GROUND NU VPP NU IGNITION VDD DATA Y L The SCL5616HW is supplied in wafer form and is rated for continuous operation over the automotive temperature range of -40°C to +85°C. c3 0.080 x 0.120 in g4 T C Dwg. No. PC-001 ABSOLUTE MAXIMUM RATINGS Supply Current, IDD .......................... 2.0 mA Input Voltage Range, VIN (except VPP) ...................... -0.3 V to VDD (Programming Power Voltage, VPP) .................. 18.5 V Input Current (except VPP), IIN ......... ±10 mA Power Dissipation, PD ................... 300 mW Operating Temperature Range, TA .................................. -40°C to +85°C Storage Temperature Range, TS ................................ -65°C to +150°C Caution: These CMOS devices have static protection, but are susceptible to damage if exposed to extremely high static electrical charges. Always order by complete part number: SCL5616HW . 5616 2-FUNCTION, 4-DIGIT LCD AUTOMOTIVE CLOCK TYPICAL APPLICATION 6.8 kΩ 4.194304 MHz CL = 15 pF, RS = 50 Ω IGNITION +12 V VDD 1 MΩ MINUTES + 47 µF BACKPLANE AM S2 SEGMENTS HOURS PM S1 GROUNDS Dwg. EC-001 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 W Copyright © 1990, 1995, Allegro MicroSystems, Inc. 5616 2-FUNCTION, 4-DIGIT LCD AUTOMOTIVE CLOCK ELECTRICAL CHARACTERISTICS at TA = -40°C to +85°C, in Typical Application (unless otherwise noted). Limits Characteristic Symbol Test Conditions Min. Typ. Max. Units Operating Voltage Range VDD TA = +25°C 4.5 — — V Zener Voltage VDD IDD = 1.0 mA 5.5 — 6.8 V Segment Output Current IOUT VDD = 5.0 V, VOUT = 4.8 V -20 — — µA VDD = 5.0 V, VOUT = 0.2 V 120 — — µA VDD = 5.0 V, VOUT = 4.8 V -80 — — µA VDD = 5.0 V, VOUT = 0.2 V 240 — — µA VDD ≥5.0 V 4.0 — — V S1, S2, DATA, or SELECT -55 — -700 µA — 4.194 304 — MHz VDD = Zener voltage — — 200 ms ∆VDD = ±100 mV — — ±1.0 ppM Backplane Output Current LCD Drive Signal Input Current IOUT VDISP IIN Oscillator Frequency fOSC Oscillator Starting Time tOSC Oscillator Stability ∆fOSC Backplane Frequency fBP — 64 — Hz Switch Debounce Time tDB 0 — 62.5 ms Osc. Feedback Resistance ROSC — 16 — MΩ Osc. Input Capacitance COSCI — 15 — pF Osc. Output Capacitance COSCO — 30 — pF — — 1.0 mA Supply Current IDD VDD = 5.0 V NOTE: Negative current is defined as coming out of (sourcing) the specified device terminal. DISPLAY FORMAT a1 AM a2 b1 f2 a3 b2 g1 f3 g2 a4 b3 g3 f4 c3 e4 b4 g4 COLON PM e1 c1 d1 e2 c2 d2 e3 d3 c4 d4 Dwg. No. OC-001 5616 2-FUNCTION, 4-DIGIT LCD AUTOMOTIVE CLOCK FUNCTIONAL DESCRIPTION DATA Logic Levels are VDD and Ground Power-Up Reset. When power up occurs, the hours and minutes counters are reset, and the clock starts running: Operation 12-Hour mode and counting starts from 1:00 AM Programming Modes. Data is loaded by pulling DATA low (1 µs pulse duration) n times to set the desired bits for frequency correction into the data input register. This information is latched in the RAM, thus allowing the testing of the oscillator frequency adjustment without storing the selected pattern in the PROM cells. The data latched in the RAM is stored in the PROM cells when DATA is held low for a minimum of 10 ms. The data stored in the data input register is cleared on any SELECT transition (low to high or high to low). It is also cleared when the program power voltage (VPP) is reduced from 18 V to VDD. Clearing the data input register does not affect the data latched in the RAM. Program VPP DATA VD SELECT VS 18 V 18 V VDD Pulse Ground VDD Ground VDD Ground Operation DATA load for frequency correction DATA store Verify stored data FREQUENCY CORRECTION FREQUENCY CORRECTION VPP t PHDL 1 2 t wD t DHPL 3 t DLH 127 MAX VD t DHL t PLSX VS t SVDL VERIFY CYCLE (VPP = VDD ) VS t SLDV t SHDX SEGMENT OUTPUTS Dwg. No. WC-001-1 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 5616 2-FUNCTION, 4-DIGIT LCD AUTOMOTIVE CLOCK Frequency Correction. The on-chip oscillator circuit increases the crystal frequency approximately 40 ppm. This ensures that the typical crystal will operate within the tuning range. With VS at ground, data pulses are then used to trim the internal clock frequency by 2 to 254 ppm to the required value. The quantity of data pulses needed (1 to 127) is n= fBP - 64 128 x 10-6 where fBP is the measured frequency at BACKPLANE. Prior to trimming, it must be between 64.000 128 Hz and 64.016 256 Hz. Operating Modes. The operating modes of the clock are controlled by the voltages applied to VPP, SELECT, IGNITION, and switches S1 and S2. Program VPP VDD VDD 18 V SELECT VS S1 S2 IGNITION VDD VDD Ground Open Ground Open Open Ground Open X 12 V X Mode Clock running Diagnostic Programming X = Irrelevant, ground or 12 V Clock Running Mode. During the clock running mode, setting functions are achieved by either momentary or continuous operation of switches S1 and S2, which are enabled by IGNITION. Hours or minutes are incremented on S1 or S2 (respectively) depression and continue at a 1 Hz rate while the switch is depressed. S1 S2 Open Open X X Ground Open Open Ground Ground Ground IGNITION X Ground 12 V 12 V 12 V Operation Clock running Setting disabled Set hours Set Minutes Change counting sequence (12 to 24 hour or 24 to 12 hour) X = Irrelevant, ground or 12 V for IGNITION, ground or open for S1 and S2 Diagnostic Mode. To enter the diagnostic mode, S1 and S2 are operated with IGNITION connected to 12 V. All segments are displayed for as long as S1 and S2 are depressed. On opening S1 and S2, the clock will leave the diagnostic mode and go through a power-up sequence. In the SCL5616HW, the counting sequence will change (from 12 hour to 24 hour or from 24 hour to 12 hour). To inhibit the power-up reset, hold the DATA input low (ground). The counting mode will change without resetting the hours or minutes counters. 5616 2-FUNCTION, 4-DIGIT LCD AUTOMOTIVE CLOCK Stored Data Verification. In the verify mode, the complement value of the information stored in the PROM cells is brought out directly to the segment output terminals for easy verification of the stored data. If a bit is programmed (high), the appropriate segment output is turned ON (low). The segments represent the binary equivalent of the number of frequency correction data pulses entered. Frequency Selection Pulses Segment 64 b4 32 c4 16 d4 8 e4 4 c3 2 e3 1 c2 RECOMMENDED FLASH PROGRAMMING CHARACTERISTICS at TA = +25°C, Logic Levels are VDD and Ground (except PROGRAM High) Characteristic Symbol Min. PROGRAM High (18 V) to DATA Low tPHDL 1.0 — µs SELECT Valid to DATA Low tSVDL 25 — µs DATA Low to DATA High tDLH 1.0 1.5 µs DATA High to DATA Low tDHL 1.0 — µs DATA Store Pulse Duration twD 10 — ms DATA High to PROGRAM Low tDHPL 1.0 — µs PROGRAM Low to SELECT Change tPLSX 1.0 — µs SELECT Low (Verify) to DATA Valid tSLDV — 1.0 µs DATA Hold from End of Verify tSHDX — 10 ns Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the design of its products. The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 Max. Units