MEANWELL PPT

P P T- 1 2 5
125W Triple Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
PWM control and regulated
High power density 6.117W/inch3
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
SPECIFICATION
MODEL
PPT-125A
PPT-125B
PPT-125C
PPT-125D
OUTPUT NUMBER
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
DC VOLTAGE
3.3V
5V
12V
5V
12V
-12V
5V
15V
-15V
5V
24V
12V
RATED CURRENT
10A
8A
0.5A
11.5A
3A
0.5A
11A
2.5A
0.5A
7A
2.5A
0.5A
CURRENT RANGE (convection) 1 ~ 10A
0.8 ~ 8A 0.05 ~ 0.5A 1 ~ 11.5A 0.3 ~ 3A
0.05 ~ 0.5A 1 ~ 11A
0.25 ~ 2.5A 0.05 ~ 0.5A 1 ~ 7A
CH3
0.25 ~ 2.5A 0.05 ~ 0.5A
CURRENT RANGE (18CFM FAN) 1 ~ 12.5A 0.8 ~ 10A 0.05 ~ 0.63A 1 ~ 14.38A 0.3 ~ 3.75A 0.05 ~ 0.63A 1 ~ 13.75A 0.25 ~ 3.13A 0.05 ~ 0.63A 1 ~ 8.75A 0.25 ~ 3.13A 0.05 ~ 0.63A
OUTPUT
RATED POWER (convection) 79W
99.5W
100W
101W
RATED POWER (18CFM FAN) 98.8W
124.46W
125.15W
126.43W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 240mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
INPUT
CH1:3.13 ~ 3.46V
3.0%
5.0%
CH1:4.75 ~ 5.25V
3.0%
5.0%
6.0%
6.0%
CH1:4.75 ~ 5.25V
3.0%
5.0%
6.0%
CH1:4.75 ~ 5.25V
3.0%
5.0%
6.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
3.0%
3.0%
5.0%
3.0%
3.0%
5.0%
3.0%
3.0%
5.0%
3.0%
3.0%
5.0%
SETUP, RISE TIME
1000ms, 30ms/230VAC
2000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
24ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47~63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC
EFFICIENCY (Typ.)
75%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.7A/115VAC
0.75A/230VAC
COLD START 24A/230VAC
24ms/115VAC at full load
127 ~ 370VDC
PF>0.98/115VAC at full load
78%
78%
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
130 ~ 160% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
WORKING TEMP., HUMIDITY
WORKING TEMP.
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
CH1:3.6 ~ 4.45V
CH1:5.75 ~ 6.75V
CH1:5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
0.05%/
78%
CH1:5.75 ~ 6.75V
, 10 ~ 95% RH
(0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
/ 70% RH
(Note 4)
OTHERS
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
94.7Khrs min. MIL-HDBK-217F (25 )
127*76.2*34.6mm (L*W*H)
0.37Kg; 36pcs/14.3Kg/0.79CUFT
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 & HS3 can not be shorted.
File Name:PPT-125-SPEC 2010-10-18
P P T- 1 2 5
125W Triple Output with PFC Function
Mechanical Specification
series
Unit:mm
127
115.6
6.4
5
HS3
SVR1
FS1
T2A 250VAC
64.8
76.2
HS1
1
2
3
CN1
LED1
1
2
3
4
5
6
7
8
9
10
HS2
CN4
43.
Pin No.
1
2
3
Assignment
AC/L
No Pin
AC/N
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
5
Air flow
direction
AC Input Connector (CN1) : JST B3P-VH or equivalent
DC Output Connector (CN4) : JST B5P-VH*2 or equivalent
34.6
Pin No.
1
2,3
4~8
9,10
Assignment
CH3
CH2
GND
CH1
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
3max.
HS1, HS2 & HS3 can not be shorted
Block Diagram
fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
RECTIFIERS
&
FILTER
PWM & PFC
CONTROL
FG
V3
REGULATOR
RECTIFIERS
&
FILTER
V2
+5V
COM
DETECTION
CIRCUT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
125
Forced air 18CFM
90
100
80
70
70
50
60
LOAD(%)
LOAD (%)
Free air Convection
40
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
50
40
85
100
115
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:PPT-125-SPEC 2010-10-18