A AWS5503-S15 GaAs IC High Power SPDT Reflective Switch Positive Control DC - 3 GHz Advanced Product Information Rev. 0 FEATURES High Linearity (IP3 55 dBm @ 1.9 GHz) High Isolation (20 dB @ 1.9 GHz) Low Insertion Loss (0.55 dB @ 1.9 GHz)\ Low DC Power Consumption Positive 3V or 5V Control Voltage DESCRIPTION The AWS5503 is a Single Pole Double Throw (SPDT) GaAs MMIC assembled in a MSOP-8 plastic package. The AWS5503 is designed for analog and digital applications that require low insertion loss, high linearity, and small size. State selection is achieved with positive voltage. S15 MSOP-8 8 Pin Plastic Package Typical applications include: transmit/receive switch, diversity switching, and antenna selection. ELECTRICAL SPECIFICATIONS AT 25 °C (0, +5V) Parameter 1 Frequency Insertion Loss 3 2 Min Typ Max Unit DC - 1.0 GHz 1.0 - 2.0 GHz 2.0 - 3.0 GHz - 0.45 0.6 0.9 0.55 0.75 1.2 dB Isolation DC - 1.0 GHz 1.0 - 2.0 GHz 2.0 - 3.0 GHz 19 18 20 22 20 23 - dB VSWR 4 DC - 1.0 GHz 1.0 - 2.0 GHz 2.0 - 3.0 GHz - 1.2:1 1.3:1 1.7:1 1.3:1 1.4:1 1.8:1 - OPERATING CHARACTERISTICS AT 25° C (0, +5V) Parameter Frequency Min Typ Max Unit Rise, Fall (10/90% or 90/10% RF) On, Off (50% CTL to 90%/10% RF) Video Feedthru - - 60 100 50 - ns ns mV Intermodulation Intercept Point (IP3) For Two-tone Input Power +10 dBm 1.9 GHz - +55 - dBm Input Power for 1dB Compression @ +3V @ +5V 1.9 GHz 1.9 GHz - +28.5 +35 - dBm Control Voltage VLOW = 0 to 0.2 V @ 20 uA Max VHIGH = +3 V @ 100 uA Max to +5 V @ 200 uA Max VS = VHIGH + 0.2V Switching Characteritics 1. 2. 3. 4. 5. Condition 5 All measurements made in a 50 ohm system, unless otherwise specified. DC = 300 kHz. Insertion loss changes by 0.003 dB/°C. Insertion loss state. Video feedthru measured with 1 ns rise time pulse and 500 MHz bandwidth. A 1 AWS5503-S14 Advanced Product Information - Rev. 0 ABSOLUTE MAXIMUM RATINGS TRUTH TABLE Characteristics Value RF Input Power 6 W Max > 900 MHz, 0/+5 V Control Supply Voltage +8 V Control Voltage -0.2 V, +8 V Operating Temperature -40° C to +85°C Storage Temperature -65°C to +150°C qJC V2 J1 - J2 J1 - J3 VHigh 0 Isolation Insertion Loss 0 VHigh Insertion Loss Isolation VHigh = +3 to +5 V (VS = VHigh + 0.2 V) 25° C/W PIN OUT 8 7 6 V1 4 5 GND 3 C1 V2 2 Vs 1 GND RFIN (J1) V1 C3 C2 RFOUT2 (J3) RFOUT1 (J2) External DC Blocking capacitors are required on all RF ports. C1,2, 3 = 100 pF for operation >500 MHz. Pin Function D escription 1 GND 2 Vs 3 RFIN (J1) 4 GND 5 RFOUT (J2) 6 V1 C ontrol Voltage1 (Low 0V, Hi gh 3V to 5V) 7 V2 C ontrol Voltage 2 (Low 0V, Hi gh 3V to 5V) 8 RFOUT (J3) Ground connecti on. (Keep as short as possi ble) Bi as voltage for posi ti ve control (3V to 5V). RF common port. Ground connecti on. (Keep short as possi ble) RF port (can be used as an i nput or as an output) RF port (can be used as an i nput or as an output) TEST CIRCUIT LAYOUT A 2 AWS5503-S14 Advanced Product Information - Rev. 0 PACKAGE OUTLINE DRAWING NOTES: 1. Package body sizes exclude mold flash and gate burrs. S503 2. Dimension L is measured in gage plane. 3. Tolerance 0.10 mm unless otherwise specified. θ SYMBOLS A A1 A2 b C D E E1 e L y θ 4. Controlling dimensions are metric. Converted inch dimensions are not necessarily exact. DIMENSIONS IN MILLIMETERS MIN 0.81 0.00 0.76 0.28 0.13 2.90 4.80 2.90 −−− 0.40 −−− 0° NOM 1.02 −−− 0.86 0.30 0.15 3.00 4.90 3.00 0.65 0.53 −−− −−− MAX 1.22 0.20 0.97 0.38 0.23 3.10 5.00 3.10 −−− 0.66 0.10 6° DIMENSIONS IN INCHES MIN 0.032 0.000 0.030 0.011 0.005 0.114 0.189 0.114 −−− 0.016 −−− 0° NOM 0.040 −−− 0.034 0.012 0.006 0.118 0.193 0.118 0.026 0.021 −−− −−− MAX 0.048 0.008 0.038 0.015 0.009 0.122 0.197 0.122 −−− 0.026 0.004 6° ANADIGICS, Inc. 35 Technology Drive Warren, New Jersey 07059 Tel: (908) 668-5000 / Fax: (908) 668-5132 Email: [email protected] www.anadigics.com IMPORTANT NOTICE ANADIGICS, Inc. reserves the right to make changes to its products or discontinue any product at any time without notice. The Advanced Product data sheets and product specifications contained in this data sheet are subject to change prior to a products formal introduction. The information in this data sheet has been carefully checked and is assumed to be reliable. However, ANADIGICS assumes no repsponsibility for inaccuracies. ANADIGICS strongly urges customers to verift that the informationn they are using is current before placing orders. WARNING ANADIGICS products are not intened for use in life support appliances, device, or systems. Use of an ANADIGICS product in any such application without written consent is prohibited. A 3