ANADIGICS AWS5504-S14

AWS5504-S14
A
GaAs IC High Power Positive Control
SPDT Reflective Switch DC-2.0 GHz
Advanced Product Information
Rev. 1
FEATURES
• High Linearity (IP3 55 dBm @ 0.9 GHz)
• Low Insertion Loss (0.35 dB @ 0.9 GHz)
• +3 V to +5 V Operation
• Low DC Power Consumption
• Ultra Miniature SOT-6 Package
DESCRIPTION
The AWS5504 is a Single Pole Double Throw (SPDT) GaAs
MMIC switch assembled in a SOT-6 plastic package. The
AWS5504 is designed for analog and digital applications that
require low insertion loss, high linearity, and small size. The
switch can be controlled with positive, negative, or a
combination of both voltages.
S14
SOT-6
6 Pin Plastic Package
Typical applications include: transmit/receive switch,
diversity switching, and antenna selection.
ELECTRICAL SPECIFICATIONS AT 25 °C (0, +5V)
Parameter 1
Frequency
Insertion Loss 3
2
Min
Typ
Max
Unit
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
-
0.3
0.4
1.0
0.4
0.6
1.2
dB
Isolation
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
20
15
8
23
17
10
-
dB
VSWR 4
DC - 1.0 GHz
DC - 2.0 GHz
-
1.3:1
1.3:1
1.4:1
1.8:1
dB
OPERATING CHARACTERISTICS AT 25° C (0, +5V)
Parameter
Condition
Frequency
Min
Typ
Max
Unit
Switching Characteritics 5
Rise, Fall (10/90% or 90/10% RF)
On, Off (50% CTL to 90%/10% RF)
Video Feedthru
-
-
60
100
50
-
ns
ns
mV
Intermodulation Intercept Point (IP3)
For Two-tone Input Power +10 dBm
0.9 GHz
-
+55
-
dBm
0.9 GHz
-
+38
-
dBm
Input Power for 1dB Compression
Control Voltage
1.
2.
3.
4.
5.
VLOW = 0 to 0.2 V @ 20 uA Max
VHIGH = +3 V @ 100 uA Max to +5 V @ 200 uA Max
VS = VHIGH + 0.2V
All measurements made in a 50 ohm system, unless other specified.
DC = 300 kHz.
Insertion loss changes by 0.003 dB/°C.
Insertion loss state.
Video feedthru measured with 1 ns rise time pulse and 500 MHz bandwidth.
AWS5504-S14
Advanced Product Information - Rev. 0
ABSOLUTE MAXIMUM RATINGS
Characteristics
Value
RF Input Power
6 W Max > 900 MHz, 0/-5 V Control
TRUTH TABLE
Control Voltage
-0.2 V, +8 V
V1
V2
J1 - J2
J1 - J3
Operating Temperature
-40° C to +85°C
0
VHigh
Isolation
Insertion Loss
Storage Temperature
-65°C to +150°C
VHigh
0
Insertion Loss
Isolation
qJC
VHigh = +3 to +5 V (VS = Vhigh + 0.2 V)
25° C/W
PIN OUT
Vs
5
4
C2
3
RFOUT 2
(J3)
6
GND
2
C1
1
RFOUT 1
(J2)
V1
10KW
C3
RFIN
(J1)
V2
DC block capacitors C1, 2, 3 must be supplied externally.
C1, 2 , 3 = 100 pF for operation >500 MHz
P in
Function
D escription
1
RFOUT 1 (J2)
2
GND
Ground connecti on. K eep as short as
possi ble.
3
RFOUT 2 (J3)
RF port can be used as an i nput or an
ouput.
4
V2
5
RFIN (J1)/V s
6
V1
RF port can be used as an i nput or as an
output.
C ontrol Voltage 2, Low 0V , Hi gh 3V to 5V
RF common port and bi as voltage for
posi ti ve control (3V to 5V ).
C ontrol Voltage 1, Low 0V , Hi gh 3V to 5V
TEST CIRCUIT LAYOUT
A
2
AWS5504-S14
Advanced Product Information - Rev. 0
PACKAGE OUTLINE DRAWING
S504
θ
NOTES:
1. Package body sizes exclude mold
flash and gate burrs.
2. Dimension L is measured in gage
plane
3. Coplanarity: 0.1000 mm
4. Tolerance + 0.1000 mm (4 mil)
unless otherwise specified.
SYMBOLS
A
A1
A2
b
C
D
E
e
H
L
θ1
DIMENSIONS IN MILLIMETERS
MIN
1.00
0.00
0.70
0.35
0.10
2.70
1.40
2.60
0.37
1°
NOM
1.10
−−−
0.80
0.40
0.15
2.90
1.60
1.90(TYP)
2.80
−−−
5°
MAX
1.30
0.10
0.90
0.50
0.25
3.10
1.80
3.00
−−−
9°
DIMENSIONS IN INCHES
MIN
0.039
0.00
0.027
0.014
0.004
0.106
0.055
NOM
0.043
−−−
0.031
0.016
0.006
0.114
0.063
0.075(TYP)
0.102
0.110
0.015
−−−
1°
5°
MAX
0.051
0.004
0.035
0.020
0.010
0.122
0.071
0.118
−−−
9°
ANADIGICS, Inc.
35 Technology Drive
Warren, New Jersey 07059
Tel: (908) 668-5000 / Fax: (908) 668-5132
Email: [email protected]
www.anadigics.com
IMPORTANT NOTICE
ANADIGICS, Inc. reserves the right to make changes to its products or discontinue any product at any time without notice. The Advanced Product
data sheets and product specifications contained in this data sheet are subject to change prior to a products formal introduction. The information in
this data sheet has been carefully checked and is assumed to be reliable. However, ANADIGICS assumes no responsibility for inaccuracies.
ANADIGICS strongly urges customers to verify that the information they are using is current before placing orders.
WARNING
ANADIGICS products are not intended for use in life support appliances, device, or systems. Use of an ANADIGICS product in any such
application without written consent is prohibited.
A
3