ANADIGICS ATA01501D1C

ATA01501D1C
ATA01501S2C
AGC Transimpedance Amplifier
SONET OC-3
Preliminary Data Sheet - Rev 5
FEATURES
·
Single +5 Volt Supply
·
Automatic Gain Control
·
Excellent Sensitivity
·
0 dBm Optical Overload
VDD2
VDD1
GND
GND
19F
IIN
1992
VOUT
GND
GND
GND GND
CBY
CBY
GND
C AGC
GND
APPLICATIONS
·
·
·
SONET OC-3 Receiver
FDDIk Ethernet Fiber LAN
Low Noise RF Amplifier
S2
12 Pin 4 Sided
SQFP Package
D1
Electrical Characteristics (1) (TA= 25°C, VDD=+5.0V + 10%, CDIODE+CSTRAY = 0.5 pF, Det. Cathode to IIN)
PAR AMETER
MIN
Transresi stance (RL= ¥ ,Idc<500nA)
TYP
MAX
17
U N IT
KW
5.5
8
Bandwi dth -3dB (D 1C )
150
175
MHz
Bandwi dth -3dB (S2C )
130
75
MHz
500
W
Transresi stance (RL=50 W) (1)
Input Resi stance (2)
Output Resi stance
30
Supply C urrent
Input Offset Voltage
1.4
Output Offset Voltage
10
KW
50
60
W
30
45
mA
1.6
1.9
Volts
1.8
Volts
AGC Threshold (IIN) (3)
15
30
mA
Opti cal Overload
-3
0
dB m
(4)
Input Noi se C urrent (5)
14
AGC Ti me C onstant
16
m se c
(6)
Offset Voltage D ri ft
20
nA
1
mV/ º C
Opti cal Sensi ti vi ty -(D 1C ) (7)
-38
dB m
Opti cal Sensi ti vi ty - (S2C )
-37
dB m
(7)
Operati ng Voltage Range
+ 4.5
Operati ng Temperature Range
- 40
+ 5.0
1.
2.
+ 6.0
Volts
85
ºC
3.
4.
5.
6.
7.
f = 50 MHz
Measured with IIN below
AGC Threshold. During
AGC, input impedance will
decrease proportionally to IIN
Defined as the IIN where
Transresistance has
decreased by 50%.
See note on “Indirect
Measurement of Optical
Overload”.
See note on “Measurement
of Input Referred Noise
Current”.
CAGC = 220 pF
Parameter is guaranteed
(not tested) by design
and characterization
data @155Mb assuming
detector responsivity of 0.9
ATA01501D1C/ATA01501S2C
Absolute Maximum Ratings
V DD1
7.0 V
V DD2
7.0 V
IIN
5 mA
TA
Operati ng Temp. - 40 C to 125 C
TS
Storage Temp. - 65 C to 150 C
Pad Description
PAD
D escription
C omment
V DD1
V DD1
Posi ti ve supply for i nput gai n stage
V DD2
V DD2
Posi ti ve supply for second gai n stage
IIN
TIA Input C urrent
VOUT
TIA Output Voltage
C AGC
External AGC C apaci tor
C BY
Input gai n stage bypass capaci tor
C onnect detector cathode for proper operati on
Requi res external D C block
70K * C AGC = AGC ti me constant
>56 pF
Equivalent Circuit
VDD1
VDD2
AGC
19 K
70K
CAGC
+
4pF
IIN
GND
or
neg.supply
- 45
+ 0.8
VGA
US PATENT
VOUT
GND
CBY
Photodector cathode must be connected
to Iin for proper AGC operation
2
ATA01501D1C/ATA01501S2C
ATA01501D1C Die Bonding Pads
ATA01501D1C Die Typical Bonding
VDD
VDD2
56pF
VDD1
GND
GND
56pF
V DD2
GND
19 I
VDD
925 um
IIN
PIN
1992
GND
19 I
IIN
GND
1992
VOUT
GND
VOUT
GND
GND
CBY
CBY
GND GND
GND CAGC
GND
GND GND
GND
CBY CBY
GND CAGC GND
56pF
56pF
OUT
1250 um
ATA01501DS2C SQFP Package Outline
0.245 (6.22)
0.230 (5.84)
0.065 (1.65)
0.055 (1.40)
0.165 (4.19)
0.152 (3.86)
0.047 (1.19)
0.032 (0.81)
12
11
PIN NO.
FUNC TION
1
NC
2
GND
3
IIN
4
C BY
7°
o
0
0.035 (.89)
0.020 (.51)
10
0.018 (.460)
0.012 (.300)
0.021X45°
4 Sides
1
9
5
GND
2
8
6
C AGC
3
7
7
VOUT
8
GND
9
NC
10
VDD
11
GND
12
NC
0.000 (0.00)
0.020 (.51)
4
5
0.015 (.38)
0.000 (0.00)
6
4X 0.023X45°
0.024 (.61)
0.011 (.28)
0.007 (.18)
0.018 (.46)
0.032 BSC
(0.81)
ATA01501DS2C Typical SQFP Connection Package
VDD
0.1µF
NC
12
NC
IIN
11
10
1
9
2
8
3
7
GND
or
Neg.Supply
4
56 pF
5
NC
0.1µF
Vout
6
56 pF
3
ATA01501D1C/ATA01501S2C
ANADIGICS, Inc.
35 Technology Drive
Warren, New Jersey 07059
Tel: (908) 668-5000
Fax: (908) 668-5132
http://www.anadigics.com
[email protected]
IMPORTANT NOTICE
ANADIGICS, Inc. reserves the right to make changes to its products or discontinue any product at any time without notice.
The Advanced Product data sheets and product specifications contained in this data sheet are subject to change prior to
a products formal introduction. The information in this data sheet has been carefully checked and is assumed to be reliable.
However, ANADIGICS assumes no responsibility for inaccuracies. ANADIGICS strongly urges customers to verify that the
information they are using is current before placing orders.
WARNING
ANADIGICS products are not intended for use in life support appliances, devices, or systems. Use of an ANADIGICS
product in any such application without written consent is prohibited.
4