TI TMP101NA/3K

TMP100
TMP101
SBOS231C – JANUARY 2002 – REVISED JULY 2003
Digital Temperature Sensor
with I2C Interface
FEATURES
DESCRIPTION
● DIGITAL OUTPUT: I2C Serial 2-Wire
● RESOLUTION: 9- to 12-Bits, User-Selectable
● ACCURACY: ±2.0°C from –25°C to +85°C (max)
±3.0°C from –55°C to +125°C (max)
● LOW QUIESCENT CURRENT: 45µA, 0.1µA Standby
● WIDE SUPPLY RANGE: 2.7V to 5.5V
● TINY SOT23-6 PACKAGE
The TMP100 and TMP101 are 2-wire, serial output temperature sensors available in SOT23-6 packages. Requiring no
external components, the TMP100 and TMP101 are capable
of reading temperatures with a resolution of 0.0625°C.
APPLICATIONS
●
●
●
●
●
●
●
●
●
POWER-SUPPLY TEMPERATURE MONITORING
COMPUTER PERIPHERAL THERMAL PROTECTION
NOTEBOOK COMPUTERS
CELL PHONES
BATTERY MANAGEMENT
OFFICE MACHINES
THERMOSTAT CONTROLS
ENVIRONMENTAL MONITORING and HVAC
ELECTROMECHANICAL DEVICE TEMPERATURE
Temperature
SCL
GND
ADD1
The TMP100 and TMP101 feature SMBus and I2C™ interface compatibility, with the TMP100 allowing up to eight
devices on one bus. The TMP101 offers SMBus alert function with up to three devices per bus.
The TMP100 and TMP101 are ideal for extended temperature measurement in a variety of communication, computer,
consumer, environmental, industrial, and instrumentation
applications.
The TMP100 and TMP101 are specified for operation over a
temperature range of –55°C to +125°C.
I2C is a registered trademark of Philips Incorporated.
Temperature
1
2
3
Diode
Temp.
Sensor
Control
Logic
6
∆Σ
A/D
Converter
Serial
Interface
5
OSC
Config
and Temp
Register
4
SDA
SCL
ADD0
GND
V+
ALERT
TMP100
1
2
3
Diode
Temp.
Sensor
Control
Logic
6
∆Σ
A/D
Converter
Serial
Interface
5
OSC
Config
and Temp
Register
4
SDA
ADD0
V+
TMP101
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
All trademarks are the property of their respective owners.
Copyright © 2002-2003, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
www.ti.com
ELECTROSTATIC
DISCHARGE SENSITIVITY
ABSOLUTE MAXIMUM RATINGS(1)
Power Supply, V+ ............................................................................... 7.5V
Input Voltage(2) .................................................................... –0.5V to 7.5V
Operating Temperature Range ...................................... –55°C to +125°C
Storage Temperature Range ......................................... –60°C to +150°C
Junction Temperature (TJ Max) .................................................... +150°C
Lead Temperature (soldering) ....................................................... +300°C
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling
and installation procedures can cause damage.
NOTES: (1) Stresses above those listed under “Absolute Maximum Ratings”
may cause permanent damage to the device. Exposure to absolute maximum
conditions for extended periods may affect device reliability. (2) Input voltage
rating applies to all TMP100 and TMP101 input voltages.
ESD damage can range from subtle performance degradation
to complete device failure. Precision integrated circuits may be
more susceptible to damage because very small parametric
changes could cause the device not to meet its published
specifications.
PACKAGE/ORDERING INFORMATION
PACKAGE-LEAD
PACKAGE
DESIGNATOR(1)
SPECIFIED
TEMPERATURE
RANGE
PACKAGE
MARKING
ORDERING
NUMBER
TRANSPORT
MEDIA, QUANTITY
TMP100
SOT23-6
DBV
–55°C to +125°C
T100
"
"
"
"
"
TMP101
SOT23-6
DBV
–55°C to +125°C
T101
"
"
"
"
"
TMP100NA/250
TMP100NA/3K
TMP101NA/250
TMP101NA/3K
Tape and Reel, 250
Tape and Reel, 3000
Tape and Reel, 250
Tape and Reel, 3000
PRODUCT
NOTE: (1) For the most current specifications and package information, refer to our web site at www.ti.com.
PIN CONFIGURATIONS
Top View
SOT23
GND
2
ADD1
3
6
SDA
SCL
1
5
ADD0
GND
2
4
V+
ALERT
3
TMP100
2
SOT23
T101
1
T100
SCL
Top View
6
SDA
5
ADD0
4
V+
TMP101
TMP100, 101
www.ti.com
SBOS231C
ELECTRICAL CHARACTERISTICS
At TA = –55°C to +125°C, and V+ = 2.7V to 5.5V, unless otherwise noted.
TMP100, TMP101
PARAMETER
CONDITION
TEMPERATURE INPUT
Range
Accuracy (Temperature Error)
DIGITAL INPUT/OUTPUT
Input Logic Levels:
VIH
VIL
Input Current, IIN
Output Logic Levels:
VOL SDA
VOL ALERT
Resolution
Conversion Time
0V ≤ VIN ≤ 6V
IOL = 3mA
IOL = 4mA
Selectable
9-Bit
10-Bit
11-Bit
12-Bit
9-Bit
10-Bit
11-Bit
12-Bit
0
0
ISD
Serial
Serial
Serial Bus Inactive
Bus Active, SCL Freq =
Bus Active, SCL Freq =
Serial Bus Inactive
Bus Active, SCL Freq =
Bus Active, SCL Freq =
45
70
150
0.1
20
100
400kHz
3.4MHz
400kHz
3.4MHz
–55
–60
SOT23-6 Surface-Mount
TMP100, 101
SBOS231C
0.15
0.15
9 to 12
40
80
160
320
25
12
6
3
2.7
IQ
Serial
Serial
TEMPERATURE RANGE
Specified Range
Storage Range
Thermal Resistance, θJA
±0.5
±1.0
±0.0625
0.7(V+)
–0.5
Conversion Rate
Shutdown Current
TYP
–55
–25°C to +85°C
–55°C to +125°C
Selectable
Resolution
POWER SUPPLY
Operating Range
Quiescent Current
MIN
www.ti.com
MAX
UNITS
+125
±2.0
±3.0
°C
°C
°C
°C
6.0
0.3(V+)
1
V
V
µA
0.4
0.4
V
V
Bits
ms
ms
ms
ms
s/s
s/s
s/s
s/s
75
150
300
600
5.5
75
1
+125
+150
150
V
µA
µA
µA
µA
µA
µA
°C
°C
°C/W
3
TYPICAL CHARACTERISTICS
At TA = +25°C, V+ = 5.0V, unless otherwise noted.
QUIESCENT CURRENT vs TEMPERATURE
SHUTDOWN CURRENT vs TEMPERATURE
1.0
70
0.9
0.8
60
0.7
0.6
ISD (µA)
IQ (µA)
V+ = 5V
50
0.5
0.4
0.3
V+ = 2.7V
0.2
40
0.1
0.0
Serial Bus Inactive
–0.1
30
–60
–40 –20
0
20
40
60
80
100
120 140
–60
–40 –20
0
Temperature (°C)
20
40
60
80
100
120 140
Temperature (°C)
CONVERSION TIME vs TEMPERATURE
TEMPERATURE ACCURACY vs TEMPERATURE
400
2.0
350
Temperature Error (°C)
Conversion Time (ms)
1.5
V+ = 5V
300
V+ = 2.7V
1.0
0.5
0.0
–0.5
–1.0
–1.5
NOTE: 12-bit resolution.
NOTE: 12-bit resolution.
3 Typical Units
250
–2.0
–60
–40 –20
0
20
40
60
80
100
120 140
–60
–40 –20
0
Temperature (°C)
20
40
60
80
100
120 140
Temperature (°C)
QUIESCENT CURRENT WITH
BUS ACTIVITY vs TEMPERATURE
180
160
125°C
140
25°C
IQ (µA)
120
100
125°C
80
25°C
–55°C
60
40
20
–55°C
FAST MODE
Hs MODE
0
10k
100k
1M
10M
SCL Frequency (Hz)
4
TMP100, 101
www.ti.com
SBOS231C
APPLICATIONS INFORMATION
The TMP100 and TMP101 are digital temperature sensors
optimal for thermal management and thermal protection
applications. The TMP100 and TMP101 are I2C and SMBus
interface compatible and are specified over a temperature
range of –55°C to +125°C.
The TMP100 and TMP101 require no external components
for operation except for pull-up resistors on SCL, SDA, and
ALERT, although a 0.1µF bypass capacitor is recommended,
as shown in Figure 1 and Figure 2.
POINTER REGISTER
Figure 3 shows the internal register structure of the TMP100
and TMP101. The 8-bit Pointer Register of the TMP100 and
TMP101 is used to address a given data register. The Pointer
Register uses the two LSBs to identify which of the data
registers should respond to a read or write command. Table
I identifies the bits of the Pointer Register byte. Table II
describes the pointer address of the registers available in the
TMP100 and TMP101. Power-up Reset value of P1/P0 is 00.
Pointer
Register
V+
Temperature
Register
0.1µF
4
SCL
To I2C
Controller
SDA
3
1
ALERT
(Output)
6
5
SCL
Configuration
Register
TMP101
I/O
Control
Interface
ADD0
(Input)
2
TLOW
Register
NOTE: (1) SCL, SDA and ALERT
require pull-up resistors for
I2C bus applications.
SDA
THIGH
Register
GND
FIGURE 1. Typical Connections of the TMP101.
FIGURE 3. Internal Register Structure of TMP100 and TMP101.
V+
SCL
To I2C
Controller
SDA
3
1
6
P6
P5
P4
P3
P2
0
0
0
0
0
0
ADD1
(Input)
P1
P0
0
0
1
1
0
1
0
1
TMP100
5
P1
P0
Register Bits
TABLE I. Pointer Register Byte.
0.1µF
4
P7
ADD0
(Input)
2
REGISTER
Temperature Register (READ Only)
Configuration Register (READ/WRITE)
TLOW Register (READ/WRITE)
THIGH Register (READ/WRITE)
TABLE II. Pointer Addresses of the TMP100 and TMP101
Registers.
NOTE: (1) SCL and SDA
require pull-up resistors for
I2C bus applications.
TEMPERATURE REGISTER
GND
FIGURE 2. Typical Connections of the TMP100.
The die flag of the lead frame is connected to pin 2. The
sensing device of the TMP100 and TMP101 is the chip itself.
Thermal paths run through the package leads as well as the
plastic package. The lower thermal resistance of metal causes
the leads to provide the primary thermal path. The GND pin
of the TMP100 or TMP101 is directly connected to the metal
lead frame, and is the best choice for thermal input.
To maintain the accuracy in applications requiring air or
surface temperature measurement, care should be taken to
isolate the package and leads from ambient air temperature.
A thermally conductive adhesive will assist in achieving
accurate surface temperature measurement.
The Temperature Register of the TMP100 or TMP101 is a 12bit read-only register that stores the output of the most recent
conversion. Two bytes must be read to obtain data and are
described in Table III and Table IV. The first 12 bits are used
to indicate temperature with all remaining bits equal to zero.
Data format for temperature is summarized in Table V.
Following power-up or reset, the Temperature Register will
read 0°C until the first conversion is complete.
D7
D6
D5
D4
D3
D2
D1
D0
T11
T10
T9
T8
T7
T6
T5
T4
TABLE III. Byte 1 of Temperature Register.
D7
D6
D5
D4
D3
D2
D1
D0
T3
T2
T1
T0
0
0
0
0
TABLE IV. Byte 2 of Temperature Register.
TMP100, 101
SBOS231C
www.ti.com
5
TEMPERATURE
(°C)
DIGITAL OUTPUT
(BINARY)
128
127.9375
100
80
75
50
25
0.25
0.0
–0.25
–25
–55
–128
0111
0111
0110
0101
0100
0011
0001
0000
0000
1111
1110
1100
1000
1111
1111
0100
0000
1011
0010
1001
0000
0000
1111
0111
1001
0000
HEX
1111
1111
0000
0000
0000
0000
0000
0100
0000
1100
0000
0000
0000
7FF
7FF
640
500
4B0
320
190
004
000
FFC
E70
C90
800
THIGH
Measured
Temperature
TLOW
TMP101 ALERT PIN
(Comparator Mode)
POL = 0
TMP101 ALERT PIN
(Interrupt Mode)
POL = 0
TABLE V. Temperature Data Format.
TMP101 ALERT PIN
(Comparator Mode)
POL = 1
The user can obtain 9, 10, 11, or 12 bits of resolution by
addressing the Configuration Register and setting the resolution bits accordingly. For 9, 10, or 11 bit resolution, the most
significant bits in the Temperature Register are used with the
unused LSBs set to zero.
TMP101 ALERT PIN
(Interrupt Mode)
POL = 1
Read
Read
Read
Time
CONFIGURATION REGISTER
FIGURE 4. Output Transfer Function Diagrams.
The Configuration Register is an 8-bit read/write register
used to store bits that control the operational modes of the
temperature sensor. Read/write operations are performed
MSB first. The format of the Configuration Register for the
TMP100 and TMP101 is shown in Table VI, followed by a
breakdown of the register bits. The power-up/reset value of
the Configuration Register is all bits equal to 0. The OS/
ALERT bit will read as 1 after power-up/reset.
Byte
D7
D6
D5
D4
D3
D2
D1
D0
1
OS/ALERT
R1
R0
F1
F0
POL
TM
SD
FAULT QUEUE (F1/F0)
A fault condition occurs when the measured temperature
exceeds the limits set in the THIGH and TLOW Registers. The
Fault Queue is provided to prevent a false alert due to
environmental noise and requires consecutive fault measurements to trigger the alert function of the TMP101. Table
VII defines the number of measured faults that may be
programmed to trigger an alert condition.
TABLE VI. Configuration Register Format.
SHUTDOWN MODE (SD)
The Shutdown Mode of the TMP100 and TMP101 allows the
user to save maximum power by shutting down all device
circuitry other than the serial interface, which reduces current
consumption to less than 1µA. For the TMP100 and TMP101,
Shutdown Mode is enabled when the SD bit is 1. The device will
shutdown once the current conversion is completed. For SD
equal to 0, the device will maintain continuous conversion.
THERMOSTAT MODE (TM)
CONSECUTIVE FAULTS
0
1
0
1
1
2
4
6
CONVERTER RESOLUTION (R1/R0)
The Converter Resolution Bits control the resolution of the
internal Analog-to-Digital (A/D) converter. This allows the
user to maximize efficiency by programming for higher resolution or faster conversion time. Table VIII identifies the
Resolution Bits and relationship between resolution and conversion time.
POLARITY (POL)
6
F0
0
0
1
1
TABLE VII. Fault Settings of the TMP100 and TMP101.
The Thermostat Mode bit of the TMP101 indicates to the device
whether to operate in Comparator Mode (TM = 0) or Interrupt
Mode (TM = 1). For more information on comparator and
interrupt modes, see text “HIGH and LOW Limit Registers.”
The Polarity Bit of the TMP101 allows the user to adjust the
polarity of the ALERT pin output. If POL = 0, the ALERT pin
will be active LOW, as shown in Figure 4. For POL = 1 the
ALERT Pin will be active HIGH, and the state of the ALERT
Pin is inverted.
F1
R1
R0
RESOLUTION
CONVERSION TIME
(typical)
0
0
1
1
0
1
0
1
9 Bits (0.5°C)
10 Bits (0.25°C)
11 Bits (0.125°C)
12 Bits (0.0625°C)
40ms
80ms
160ms
320ms
TABLE VIII. Resolution of the TMP100 and TMP101.
TMP100, 101
www.ti.com
SBOS231C
OS/ALERT (OS)
The TMP100 and TMP101 feature a One-Shot Temperature
Measurement Mode. When the device is in Shutdown Mode,
writing a 1 to the OS/ALERT bit will start a single temperature
conversion. The device will return to the shutdown state at
the completion of the single conversion. This is useful to
reduce power consumption in the TMP100 and TMP101
when continuous monitoring of temperature is not required.
Reading the OS/ALERT bit will provide information about the
Comparator Mode status. The state of the POL bit will invert the
polarity of data returned from the OS/ALERT bit. For POL = 0,
the OS/ALERT will read as 0 until the temperature equals or
exceeds THIGH for the programmed number of consecutive
faults, causing the OS/ALERT bit to read as 1. The OS/ALERT
bit will continue to read as 1 until the temperature falls below
TLOW for the programmed number of consecutive faults when it
will again read as 0. The status of the TM bit does not affect the
status of the OS/ALERT bit.
HIGH AND LOW LIMIT REGISTERS
In Comparator Mode (TM = 0), the ALERT Pin of the TMP101
becomes active when the temperature equals or exceeds the
value in THIGH and generates a consecutive number of faults
according to fault bits F1 and F0. The ALERT pin will remain
active until the temperature falls below the indicated TLOW
value for the same number of faults.
In Interrupt Mode (TM = 1) the ALERT Pin becomes active
when the temperature equals or exceeds THIGH for a consecutive number of fault conditions. The ALERT pin remains
active until a read operation of any register occurs or the
device successfully responds to the SMBus Alert Response
Address. The ALERT pin will also be cleared if the device is
placed in Shutdown Mode. Once the ALERT pin is cleared,
it will only become active again by the temperature falling
below TLOW. When the temperature falls below TLOW, the
ALERT pin will become active and remain active until cleared
by a read operation of any register or a successful response
to the SMBus Alert Response Address. Once the ALERT pin
is cleared, the above cycle will repeat with the ALERT pin
becoming active when the temperature equals or exceeds
THIGH. The ALERT pin can also be cleared by resetting the
device with the General Call Reset command. This will also
clear the state of the internal registers in the device returning
the device to Comparator Mode (TM = 0).
Both operational modes are represented in the Figure 4. Tables
IX and X describe the format for the THIGH and TLOW registers.
Power-up Reset values for THIGH and TLOW are: THIGH = 80°C
and TLOW = 75°C. The format of the data for THIGH and TLOW
is the same as for the Temperature Register.
All 12 bits for the Temperature, THIGH, and TLOW registers are
used in the comparisons for the ALERT function for all converter resolutions. The three LSBs in T HIGH and TLOW can
affect the ALERT output even if the converter is configured for
9-bit resolution.
Byte
D7
D6
D5
D4
D3
D2
D1
D0
1
H11
H10
H9
H8
H7
H6
H5
H4
Byte
D7
D6
D5
D4
D3
D2
D1
D0
2
H3
H2
H1
H0
0
0
0
0
TABLE IX. Bytes 1 and 2 of THIGH Register.
Byte
D7
D6
D5
D4
D3
D2
D1
D0
1
L11
L10
L9
L8
L7
L6
L5
L4
Byte
D7
D6
D5
D4
D3
D2
D1
D0
2
L3
L2
L1
L0
0
0
0
0
TABLE X. Bytes 1 and 2 of TLOW Register.
SERIAL INTERFACE
The TMP100 and TMP101 operate only as slave devices on
the I2C bus and SMBus. Connections to the bus are made via
the open-drain I/O lines SDA and SCL. The TMP100 and
TMP101 support the transmission protocol for fast (up to
400kHz) and high-speed (up to 3.4MHz) modes. All data
bytes are transmitted most significant bit first.
SERIAL BUS ADDRESS
To program the TMP100 and TMP101, the master must first
address slave devices via a slave address byte. The slave
address byte consists of seven address bits, and a direction
bit indicating the intent of executing a read or write operation.
The TMP100 features two address pins to allow up to eight
devices to be addressed on a single I2C interface. Table XI
describes the pin logic levels used to properly connect up to eight
devices. ‘Float’ indicates the pin is left unconnected. The state of
pins ADD0 and ADD1 is sampled on the first I2C bus communication and should be set prior to any activity on the interface.
ADD1
ADD0
SLAVE ADDRESS
0
0
0
1
1
1
Float
Float
0
Float
1
0
Float
1
0
1
1001000
1001001
1001010
1001100
1001101
1001110
1001011
1001111
TABLE XI. Address Pins and Slave Addresses for TMP100.
The TMP101 features one address pin and an ALERT pin,
allowing up to three devices to be connected per bus. Pin logic
levels are described in Table XII. The address pins of the
TMP100 and TMP101 are read after reset or in response to an
I2C address acquire request. Following reading, the state of
the address pins is latched to minimize power dissipation
associated with detection.
ADD0
SLAVE ADDRESS
0
Float
1
1001000
1001001
1001010
TABLE XII. Address Pins and Slave Address for TMP101.
TMP100, 101
SBOS231C
www.ti.com
7
BUS OVERVIEW
The device that initiates the transfer is called a “master,” and
the devices controlled by the master are “slaves.” The bus
must be controlled by a master device that generates the
serial clock (SCL), controls the bus access, and generates
the START and STOP conditions.
To address a specific device, a START condition is initiated,
indicated by pulling the data-line (SDA) from a HIGH to LOW
logic level while SCL is HIGH. All slaves on the bus shift in the
slave address byte, with the last bit indicating whether a read
or write operation is intended. During the ninth clock pulse,
the slave being addressed responds to the master by generating an Acknowledge and pulling SDA LOW.
Data transfer is then initiated and sent over eight clock pulses
followed by an Acknowledge Bit. During data transfer SDA
must remain stable while SCL is HIGH, as any change in SDA
while SCL is HIGH will be interpreted as a control signal.
Once all data has been transferred, the master generates a
STOP condition indicated by pulling SDA from LOW to HIGH,
while SCL is HIGH.
WRITING/READING TO THE TMP100 AND TMP101
Accessing a particular register on the TMP100 and TMP101
is accomplished by writing the appropriate value to the
Pointer Register. The value for the Pointer Register is the
first byte transferred after the I2C slave address byte with the
R/W bit LOW. Every write operation to the TMP100 and
TMP101 requires a value for the Pointer Register. (Refer to
Figure 6.)
When reading from the TMP100 and TMP101, the last value
stored in the Pointer Register by a write operation is used to
determine which register is read by a read operation. To
change the register pointer for a read operation, a new value
must be written to the Pointer Register. This is accomplished
by issuing an I2C slave address byte with the R/W bit LOW,
followed by the Pointer Register Byte. No additional data is
required. The master can then generate a START condition
and send the I2C slave address byte with the R/W bit HIGH
to initiatnlthe read command. See Figure 7 for details of this
sequence. If repeated reads from the same register are
desired, it is not necessary to continually send the Pointer
Register bytes as the TMP100 and TMP101 will remember
the Pointer Register value until it is changed by the next write
operation.
SLAVE MODE OPERATIONS
The TMP100 and TMP101 can operate as slave receivers or
slave transmitters.
Slave Receiver Mode:
The first byte transmitted by the master is the slave address, with
the R/W bit LOW. The TMP100 or TMP101 then acknowledges
reception of a valid address. The next byte transmitted by the
master is the Pointer Register. The TMP100 or TMP101 then
acknowledges reception of the Pointer Register byte. The next
8
byte or bytes are written to the register addressed by the Pointer
register. The TMP100 and TMP101 will acknowledge reception of each data byte. The master may terminate data
transfer by generating a START or STOP condition.
Slave Transmitter Mode:
The first byte is transmitted by the master and is the slave
address, with the R/W bit HIGH. The slave acknowledges
reception of a valid slave address. The next byte is transmitted by the slave and is the most significant byte of the
register indicated by the Pointer Register. The master acknowledges reception of the data byte. The next byte transmitted by the slave is the least significant byte. The master
acknowledges reception of the data byte. The master may
terminate data transfer by generating a Not-Acknowledge on
reception of any data byte, or generating a START or STOP
condition.
SMBus ALERT FUNCTION
The TMP101 supports the SMBus Alert function. When the
TMP101 is operating in Interrupt Mode (TM = 1), the ALERT
pin of the TMP101 may be connected as an SMBus Alert
signal. When a master senses that an ALERT condition is
present on the ALERT line, the master sends an SMBus Alert
command (00011001) on the bus. If the ALERT pin of the
TMP101 is active, the TMP101 will acknowledge the SMBus
Alert command and respond by returning its slave address
on the SDA line. The eighth bit (LSB) of the slave address
byte will indicate if the temperature exceeding THIGH or falling
below TLOW caused the ALERT condition. This bit will be
HIGH if the temperature is greater than or equal to THIGH.
This bit will be LOW if the temperature is less than TLOW.
Refer to Figure 8 for details of this sequence.
If multiple devices on the bus respond to the SMBus Alert
command, arbitration during the slave address portion of the
SMBus alert command will determine which device will clear
its ALERT status. If the TMP101 wins the arbitration, its
ALERT pin will become inactive at the completion of the
SMBus Alert command. If the TMP101 loses the arbitration,
its ALERT pin will remain active.
The TMP100 will also respond to the SMBus ALERT command if its TM bit is set to 1. Since it does not have an ALERT
pin, the master needs to periodically poll the device by
issuing an SMBus Alert command. If the TMP100 has generated an ALERT, it will acknowledge the SMBus Alert
command and return its slave address in the next byte.
GENERAL CALL
The TMP100 and TMP101 respond to the I2C General Call
address (0000000) if the eighth bit is 0. The device will
acknowledge the General Call address and respond to commands in the second byte. If the second byte is 00000100,
the TMP100 and TMP101 will latch the status of their
address pins, but will not reset. If the second byte is 00000110,
the TMP100 and TMP101 will latch the status of their
address pins and reset their internal registers.
TMP100, 101
www.ti.com
SBOS231C
HIGH-SPEED MODE
In order for the I2C bus to operate at frequencies above
400kHz, the master device must issue an Hs-mode master
code (00001XXX) as the first byte after a START condition to
switch the bus to high-speed operation. The TMP100 and
TMP101 will not acknowledge this byte as required by the I2C
specification, but will switch their input filters on SDA and
SCL and their output filters on SDA to operate in Hs-mode,
allowing transfers at up to 3.4MHz. After the Hs-mode master
code has been issued, the master will transmit an I2C slave
address to initiate a data transfer operation. The bus will
continue to operate in Hs-mode until a STOP condition
occurs on the bus. Upon receiving the STOP condition, the
TMP100 and TMP101 will switch their input and output filters
back to fast-mode operation.
TIMING DIAGRAMS
The TMP100 and TMP101 are I2C and SMBus compatible.
Figures 5 to 8 describe the various operations on the TMP100
and TMP101. Bus definitions are given below. Parameters
for Figure 5 are defined in Table XIII.
Bus Idle: Both SDA and SCL lines remain HIGH.
Start Data Transfer: A change in the state of the SDA line,
from HIGH to LOW, while the SCL line is HIGH, defines a
START condition. Each data transfer is initiated with a
START condition.
Stop Data Transfer: A change in the state of the SDA line
from LOW to HIGH while the SCL line is HIGH defines a
STOP condition. Each data transfer is terminated with a
repeated START or STOP condition.
Data Transfer: The number of data bytes transferred between a START and a STOP condition is not limited and is
determined by the master device. The receiver acknowledges the transfer of data.
Acknowledge: Each receiving device, when addressed, is
obliged to generate an Acknowledge bit. A device that
acknowledges must pull down the SDA line during the
Acknowledge clock pulse in such a way that the SDA line is
stable LOW during the HIGH period of the Acknowledge
clock pulse. Setup and hold times must be taken into account. On a master receive, the termination of the data
transfer can be signaled by the master generating a NotAcknowledge on the last byte that has been transmitted by
the slave.
FAST MODE
PARAMETER
SCLK Operating Frequency
Bus Free Time Between STOP and START Condition
MIN
f(SCLK)
HIGH-SPEED MODE
MAX
MIN
0.4
MAX
UNITS
3.4
MHz
t(BUF)
600
160
ns
t(HDSTA)
600
160
ns
Repeated START Condition Setup Time
t(SUSTA)
600
160
ns
STOP Condition Setup Time
t(SUSTO)
600
160
ns
Data Hold Time
t(HDDAT)
0
0
ns
Data Setup Time
t(SUDAT)
100
10
ns
SCLK Clock LOW Period
t(LOW)
1300
160
ns
SCLK Clock HIGH Period
t(HIGH)
600
60
Hold Time After Repeated START Condition.
After this period, the first clock is generated.
ns
Clock/Data Fall Time
tF
300
160
ns
Clock/Data Rise Time
tR
300
160
ns
TABLE XIII. Timing Diagram Definitions.
TMP100, 101
SBOS231C
www.ti.com
9
I2C TIMING DIAGRAMS
t(LOW)
tF
tR
t(HDSTA)
SCL
t(HDSTA)
t(HIGH)
t(SUSTO)
t(SUSTA)
t(HDDAT)
t(SUDAT)
SDA
t(BUF)
P
S
S
P
FIGURE 5. I2C Timing Diagram.
1
9
1
9
…
SCL
SDA
1
0
0
1
A2
A1
A0
R/W
Start By
Master
0
0
0
0
0
0
P1
ACK By
TMP100 or TMP101
…
P0
ACK By
TMP100 or TMP101
Frame 1 I2C Slave Address Byte
Frame 2 Pointer Register Byte
1
9
1
9
SCL
(Continued)
SDA
(Continued)
D7
D6
D5
D4
D3
D2
D1
D7
D0
D6
D5
D4
D3
Frame 3 Data Byte 1
D2
D1
D0
ACK By
Stop By
TMP100 or TMP101 Master
ACK By
TMP100 or TMP101
Frame 4 Data Byte 2
FIGURE 6. I2C Timing Diagram for Write Word Format.
10
TMP100, 101
www.ti.com
SBOS231C
1
9
1
9
…
SCL
SDA
0
1
0
1
A2
A1
A0
R/W
Start By
Master
0
0
0
0
0
0
P1
…
P0
ACK By
TMP100 or TMP101
ACK By
TMP100 or TMP101
Frame 1 I2C Slave Address Byte
Frame 2 Pointer Register Byte
1
9
1
9
…
SCL
(Continued)
SDA
(Continued)
1
0
0
1
A2
A1
A0
D7
R/W
Start By
Master
D6
D5
D4
D3
ACK By
TMP100 or TMP101
D1
…
D0
From
TMP100 or TMP101
Frame 3 I2C Slave Address Byte
1
D2
ACK By
Master
Frame 4 Data Byte 1 Read Register
9
SCL
(Continued)
SDA
(Continued)
D7
D6
D5
D4
D3
D2
D1
D0
From
TMP100 or TMP101
ACK By
Master
Stop By
Master
Frame 5 Data Byte 2 Read Register
FIGURE 7. I2C Timing Diagram for Read Word Format.
ALERT
1
9
1
9
SCL
SDA
0
0
0
1
1
0
Start By
Master
0
R/W
1
ACK By
TMP100 or TMP101
Frame 1 SMBus ALERT Response Address Byte
0
0
1
A2
A1
A0
Status
From
NACK By
TMP100 or TMP101 Master
Stop By
Master
Frame 2 Slave Address From TMP100
FIGURE 8. Timing Diagram for SMBus ALERT.
TMP100, 101
SBOS231C
www.ti.com
11
PACKAGE OPTION ADDENDUM
www.ti.com
3-Oct-2003
PACKAGING INFORMATION
ORDERABLE DEVICE
STATUS(1)
PACKAGE TYPE
PACKAGE DRAWING
PINS
PACKAGE QTY
TMP100NA/250
ACTIVE
SOP
DBV
6
250
3000
TMP100NA/3K
ACTIVE
SOP
DBV
6
TMP101NA/250
ACTIVE
SOP
DBV
6
250
TMP101NA/3K
ACTIVE
SOP
DBV
6
3000
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Amplifiers
Applications
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Mailing Address:
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2003, Texas Instruments Incorporated