ELANTEC ELH0002H

Current Amplifier
Features
General Description
#
#
#
#
#
#
#
#
#
The ELH0002 is a general purpose hybrid current amplifier
buffer that is built on a single substrate.
400 mA pulsed output current
DC to 30 MHz bandwidth
200 V/ms slew rate
Low harmonic distortion
High input impedanceÐ400 kX
Low output impedanceÐ6X
High power efficiency
Operation from g 5V to g 20V
Output voltage swing approaches
supply voltage
# MIL-STD-883 devices
manufactured in U.S.A.
Applications
#
#
#
#
#
Line driver
30 MHz buffer
High-speed D/A conversion
Instrumentation buffer
Precision current source
The ELH0002 is ideal for current buffering operational amplifiers without changing the characteristics of the Op Amp. The
ELH0002 uses a completely symmetrical circuit to provide a
low output impedance when both sourcing and sinking current.
This means the output will drive coaxial cables and other capacitive loads with equivalent rise and fall times.
ELH0002H/883/7801301XX
ELH0002H/883/7801301XX
The ELH0002 is specified for operation over the b 55§ C to
a 125§ C military temperature range.
Elantec facilities comply with MIL-I-45208A and are MILSTD-1772 certified. Elantec’s Military devices comply with
MIL-STD-883B Revision C and are manufactured in our rigidly
controlled, ultra-clean facilities in Milpitas, California. For additional information on Elantec’s Quality and Reliability Assurance Policy and procedures request brochure QRA-1.
Equivalent Schematic
Ordering Information
Part No.
Temp. Range
Pkg. OutlineÝ
ELH0002H/883B b 55§ C to a 125§ C TO-5 MDP0001
7801301XX is the DESC version of this
device.
0002 – 1
Top View
Case is electrically isolated.
Note: All information contained in this data sheet has been carefully checked and is believed to be accurate as of the date of publication; however, this data sheet cannot be a ‘‘controlled document’’. Current revisions, if any, to these
specifications are maintained at the factory and are available upon your request. We recommend checking the revision level before finalization of your design documentation. Patent pending.
CMSÝ0002DS
© 1989 Elantec, Inc.
July 1991 Rev G
0002 – 2
ELH0002H/883/7801301XX
Current Amplifier
Absolute Maximum Ratings (TA e 25§ C)
Supply Voltage
Input Voltage
Power Dissipation Ambient
Storage Temperature
VS
VIN
PD
TST
g 22V
TA
g 22V
600 mW
b 65§ C to a 150§ C
Operating Temperature Range
ELH0002
Steady State Current
Pulsed Output Current
(50 ms On/1 second Off)
b 55§ C to a 125§ C
g 100 mA
g 400 mA
Important Note:
All parameters having Min/Max specifications are guaranteed. The Test Level column indicates the specific device testing actually
performed during production and Quality inspection. Elantec performs most electrical tests using modern high-speed automatic test
equipment, specifically the LTX77 Series system. Unless otherwise noted, all tests are pulsed tests, therefore TJ e TC e TA.
Test Level
I
II
III
IV
V
Test Procedure
100% production tested and QA sample tested per QA test plan QCX0002.
100% production tested at TA e 25§ C and QA sample tested at TA e 25§ C ,
TMAX and TMIN per QA test plan QCX0002.
QA sample tested per QA test plan QCX0002.
Parameter is guaranteed (but not tested) by Design and Characterization Data.
Parameter is typical value at TA e 25§ C for information purposes only.
DC Electrical Characteristics VS e g 12V, TMIN s TA s TMAX
ELH0002
Description
Test Conditions
Min
Max
Test
Level
Units
Typ
g 10
g 30
I
mV
VOS
Output Offset
Voltage
RS e 300X, RL e 1 kX
AV
Voltage Gain
RS e 10 kX, RL e 1 kX,
VIN e g 10 Vdc
0.95
0.97
I
V/V
RIN
Input Impedance
RS e 200 kX, VIN e g 1 Vdc ,
RL e 1 kX
180
400
I
kX
ROUT
Output Impedance
RS e 50X, VIN e g 1 Vdc ,
RS e 10 kX
VO
Output Voltage
Swing
VIN e g 12V, RL e 1 KX
g 10
I
V
VS e g 15V, VIN e g 12V,
RS e 50X, RL e 100X, TA e 25§ C
g 10
I
V
IB
Input Current
RS e 10 kX, RL e 1 kX
IS a
Positive
Supply Current
RS e 10 kX, RL e 1 kX
ISb
Negative
Supply Current
RS e 10 kX, RL e 1 kX
6
X
g 11
g6
g 10
I
mA
6
10
I
mA
b6
b 10
I
mA
Note 1: Elantec’s ELH0002H/200 is tested to the ELH0002 DC limits at b25§ C, a 25§ C and a 125§ C, and the AC limits at 25§ C. In
addition, the parts are also tested to the DC limits for VOS, AVOL with RL e 1 kX, IIN, IS a and ISb at 200§ C.
2
TD is 3.1in
Parameter
ELH0002H/883/7801301XX
Current Amplifier
AC Electrical Characteristics VS e g 12V, TA e 25§ C
ELH0002
Description
Test Conditions
AV
Voltage Gain
RS e 10 kX, RL e 1 kX
VIN e 3 VP-P, f e 1 kHz
AI
Current Gain
VIN e 1 VRMS, f e 1 kHz
RIN
Input Impedance
RS e 200 kX, VIN e 1 VRMS,
RL e 1 kX, f e 1 kHz
ROUT
Output Impedance
RL e 50X, VIN e 1 VRMS,
RS e 10 kX, f e 1 kHz
HD
Harmonic
Distortion
VIN e 5 VRMS, f e 1 kHz
tr
Rise Time
RL e 50X, DVIN e 100 mV
Min
Typ
0.95
0.97
Max
Test
Level
Units
I
V/V
40
180
A/mA
400
6
10
0.1
7
12
I
kX
I
X
V
%
III
ns
Typical Performance Curves
Maximum Power
Dissipation
Frequency Response
Supply Current
Positive Pulse
Input Impedance
(Magnitude & Phase)
Negative Pulse
0002 – 3
3
TD is 2.2in
Parameter
ELH0002H/883/7801301XX
Current Amplifier
Typical Performance
Curves Ð Contd.
Burn-In Circuit
Input Current
0002 – 5
0002 – 4
Typical Applications
High Current Operational Amplifier
Line Driver
0002 – 7
Select capacitor to adjust
time response of pulse.
0002 – 6
4
ELH0002H/883/7801301XX
TAB WIDE
Current Amplifier
ELH0002 Macromodel
input
l
l
l
l
l
l
V1 a
l
l
l
l
l
V2 a
l
l
l
l
V1b
l
V2b
*
output
l
l
*
l
l
l
.subckt M0002 8
1
2
7
6
4
* Models
.model qp pnp (is e 10eb14 bf e 300 vaf e 60 ikf e 200mA var e 6V br e 9
a rb e 30 cje e 40pF cjc e 15pF tf e 1nS xtb e 2.0)
.model qn npn (is e 10eb14 bf e 200 vaf e 200 ikf e 200mA var e 12V br e 8
a rb e 30 cje e 27pF cjc e 10pF tf e 1nS xtb e 2.0)
* Resistors
r1 1 10 5K
r2 11 7 5K
r3 3 4 2.0
r4 5 4 2.0
* Transistors
q1 7 8 10 qp
q4 6 11 5 qp
q2 1 8 11 qn
q3 2 10 3 qn
.ends
5
TD is 3.2in
* Connections:
*
*
*
*
ELH0002H/883/7801301XX
Current Amplifier
ELH0002 Macromodel Ð Contd.
0002 – 9
6
7
BLANK
ELH0002H/883/7801301XX
ELH0002H/883/7801301XX
Current Amplifier
General Disclaimer
Specifications contained in this data sheet are in effect as of the publication date shown. Elantec, Inc. reserves the right to make changes
in the circuitry or specifications contained herein at any time without notice. Elantec, Inc. assumes no responsibility for the use of any
circuits described herein and makes no representations that they are free from patent infringement.
July 1991 Rev G
WARNING Ð Life Support Policy
Elantec, Inc. products are not authorized for and should not be
used within Life Support Systems without the specific written
consent of Elantec, Inc. Life Support systems are equipment intended to support or sustain life and whose failure to perform
when properly used in accordance with instructions provided can
be reasonably expected to result in significant personal injury or
death. Users contemplating application of Elantec, Inc. products
in Life Support Systems are requested to contact Elantec, Inc.
factory headquarters to establish suitable terms & conditions for
these applications. Elantec, Inc.’s warranty is limited to replacement of defective components and does not cover injury to persons or property or other consequential damages.
Elantec, Inc.
1996 Tarob Court
Milpitas, CA 95035
Telephone: (408) 945-1323
(800) 333-6314
Fax: (408) 945-9305
European Office: 44-71-482-4596
8