SOURCE C-13-1250AC-T

1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Features
• SC Duplex Single Mode Transceiver
• Industry Standard 1x9 Footprint
• Gigabit Ethernet Compliant
• Single +3.3V/+5V Power Supply
• LVPECL Differential Inputs and Outputs (AC-coupling)
• LVTTL Signal Detection Output
• Wave Solderable and Aqueous Washable
• Uncooled laser diode with MQW structure
• Complies with Telcordia (Bellcore) GR-468-CORE
• Gigabit Ethernet Application
• RoHS compliance available
Absolute Maximum Rating
Parameter
Symbol
Min.
Max.
Unit
Note
Power Supply Voltage
Vcc
0
3.6
V
C-13-1250AC-T3-SSC(2)
Power Supply Voltage
Vcc
0
6
V
C-13-1250AC-T-SSC(2)
Output Current
Iout
0
30
mA
-
-
260
ºC
Tstg
-40
85
ºC
Soldering Temperature
Storage Temperature
10 seconds on leads only
Recommended Operating Condition
Parameter
Symbol
Min.
Typ.
Max.
Unit
Power Supply Voltage
Vcc
3.1
3.3
3.5
V
Power Supply Voltage
Vcc
4.75
5
4.25
V
Operating Temperature1
Operating Temperature1
Topr
0
-
70
ºC
Topr
-40
-
85
ºC
-
-
1250
-
Mbps
Data Rate
Note1: Please refer to ordering information
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS827-Jan0408
Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Transmitter Specifications
Parameter
Symbol
Min
Typical
Max
Unit
Optical Transmit Power
Po
-10
-
-3
dBm
C-13-1250AC-T(3)-SSC
Optical Transmit Power
Po
-5
-
0
dBm
C-13-1250AC-T(3)-SSC2
Output center Wavelength
λ
1270
1310
1355
nm
C-13-1250AC-T(3)-SSC
Output center Wavelength
λ
1275
1310
1350
nm
C-13-1250AC-T(3)-SSC2
Output Spectrum Width
∆λ
-
-
4
nm
RMS(σ), C-13-1250AC-T(3)-SSC
Output Spectrum Width
∆λ
-
-
2.5
nm
RMS(σ), C-13-1250AC-T(3)-SSC2
Extinction Ratio
ER
9
-
-
dB
0.26
ns
20% to 80% Values
20% to 80% Values
Output Eye
Notes
Compliant with IEEE 802.3
Optical Rise Time
Optical Fall Time
Relative Intensity Noise
Total Jitter
tr
-
-
tf
-
-
0.26
ns
RIN
-
-
-120
dB/Hz
TJ
-
-
0.27
ns
Symbol
Min
Typical
Max
Unit
ICC
-
-
180
mA
VIH-VIL
650
-
2000
mV
Measured with 27-1 PRBS
Transmitter Specifications
Parameter
Power Supply Current
Differential Data Input Voltage
Notes
Maximum current is specified at
Vcc= Maximum @ maximum temperature
AC-coupled
Receiver Specifications
Parameter
Sensitivity2
Maximum Input Power
Symbol
Min
Typical
Max
Unit
-
-
-
-24
dBm
Pin
-3
-
-
dBm
Notes
Signal Detect-Asserted
Pa
-
-
-24
dBm
Measured on transition: low to high
Signal Detect-Deasserted
Pd
-38
-
-
dBm
Measured on transition: high to low
Signal Detect-Hysteresis
Wavelength of Operation
1
-
-
dB
1100
-
1600
nm
Min
Typical
Max
Unit
Note
The current excludes the output load current
Note 2: Measured with 27-1 PRBS, BER= 10-12
Receiver Specifications
Parameter
Symbol
ICC
-
-
100
mA
VOH -VOL
600
-
1600
V
Signal Detect Output Voltage-Low
VSDL
-
-
0.5
V
Signal Detect Output Voltage-High
VSDH
2.0
-
-
V
Power Supply Current
Differential Data Output Voltage
LUMINENTOIC.COM
AC-coupled
LVTTL Output
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
LUMNDS827-Jan0408
Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Connection Diagram
1. (Rx GND)
2. (Rx +)
3. (Rx-)
4. (SD)
5. (Rx Vcc)
6. (Tx Vcc)
7. (TX-)
8. (TX+)
9. (Tx GND)
NC
Top View
NC
Receiver Signal Ground
Receiver Data Out
Receiver Data Out Bar
Signal Detect
Receiver Power Supply
Transmitter Power Supply
Transmitter Data In Bar
Transmitter Data In
Transmitter Signal Ground
PIN
Symbol
1
RxGND
2
RD+
See recommended circuit schematic
3
RD-
See recommended circuit schematic
4
SD
5
RxVcc
6
TxVcc
DC power for the transmitter section
7
TD-
See recommended circuit schematic
8
Warnings
TD+
See recommended circuit schematic
9
LUMINENTOIC.COM
Notes
Directly connect this pin to the receiver ground plane
Active high on this indicates a received optical signal
DC power for the receiver section
TxGND
Directly connect this pin to the transmitter ground plane
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS827-Jan0408
Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Recommended Circuit Schematic
7 6 5
9 8
TD +
Z=50
TD -
Z=50
4 3 2
1
Z=50
RD +
Z=50
RD SD
Tx Vcc
Rx Vcc
No internal
connection
Notes:
C1=C2=0.1F
C3=C4=10F
L1=L2=1H
Transceiver
Top view
No internal
connection
L1
Vcc
C3
C1
L2
C4
C2
Rx Vcc
Tx Vcc
The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals.
The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc.
A GND plane under the module is required for good EMI and sensitivity performance.
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
LUMNDS827-Jan0408
Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Package Diagram (10.4 mm SC transceiver assembly)
Top View
Front View
Side View
Rear View
Units: mm
Package Option:
Blank, A = black case
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS827-Jan0408
Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Package Diagram (9.8 mm SC transceiver assembly)
Front View
Top View
Units: mm
x8
Rear View
Side View
Package Option :
B, E = Blue case
C, D = Black case
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS827-Jan0408
Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Ordering Information
Available Options: C-13-1250AC-T(3)-SSC
C-13-1250AC-T(3)-SSCA
C-13-1250AC-T(3)-SSCB
C-13-1250AC-T(3)-SSCC
C-13-1250AC-T(3)-SSCD
C-13-1250AC-T(3)-SSCE
C-13-1250AC-T(3)-SSC2
C-13-1250AC-T(3)-SSC2A
C-13-1250AC-T(3)-SSC2B
C-13-1250AC-T(3)-SSC2C
C-13-1250AC-T(3)-SSC2D
C-13-1250AC-T(3)-SSC2E
C-13-1250AC-T(3)-SSC-G5
C-13-1250AC-T(3)-SSCA-G5
C-13-1250AC-T(3)-SSCB-G5
C-13-1250AC-T(3)-SSCC-G5
C-13-1250AC-T(3)-SSCD-G5
C-13-1250AC-T(3)-SSCE-G5
C-13-1250AC-T(3)-SSC2-G5
C-13-1250AC-T(3)-SSC2A-G5
C-13-1250AC-T(3)-SSC2B-G5
C-13-1250AC-T(3)-SSC2C-G5
C-13-1250AC-T(3)-SSC2D-G5
C-13-1250AC-T(3)-SSC2E-G5
Part numbering Definition:
C - 13 - 1250AC - T(3) -
S SC TxPower Temperature and Package -RoHS
• 13 = Wavelength 1310nm
• Communication protocol (1250 Mbps)
AC = AC coupling for data input/output
TTL Signal Detection output
• T(3)= +3.3V Transceiver, FP
• Single mode fiber
• Connector options
• Tx Power range
Blank = -10 to -3 dBm
2 = -5 to 0 dBm
• Temperature range and package
Blank = commercial temperature(0 to 70 ºC), 10.4 mm, Black case
A = industrial temperature(-40 to 85 ºC), 10.4 mm, Black case
B = industrial temperature(-40 to 85 ºC), 9.8 mm, Blue case
C = industrial temperature(-40 to 85 ºC), 9.8 mm, Black case
D = commercial temperature(0 to 70 ºC), 9.8 mm, Black case
E = commercial temperature(0 to 70 ºC), 9.8 mm, Blue case
• RoHs
Blank = RoHS non-compliant product
G5 = RoHS 5/6-compliant product (lead exemption)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS827-Jan0408
Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
8
LUMNDS827-Jan0408
Rev A.1