1.25 Gbps Bi-directional Single Fiber Transceiver B-13/15-1250(C)-TPM3-SXX-60 Features • Coaxial single mode single fiber package with optional SC/FC/ST/MU connector • Wavelength Tx 1310 nm/ Rx 1550nm • Compliant with IEEE 802.3z Gigabit Ethernet • Single +3.3V Power Supply • LVPECL Differential Inputs and Outputs • LVPECL SD Output (B-13/15-1250-TPM3-SXX-60) • LVTTL SD Output (B-13/15-1250C-TPM3-SXX-60) • Wave Solderable and Aqueous washable • Class 1 Laser Int. Safety Standad IEC 825 Compliant • Uncooled laser diode with MQW structure • Complies with Telcordia (Bellcore) GR-468-CORE • Temperature Range: 0 to 70ºC • Optical Isolation >30 dB • Cross Talk < -33 dB • Optical Return Loss > 14dB Absolute Maximum Rating Parameter Symbol Min. Max. Unit Power Supply Voltage Vcc 0 3.6 V Output Current Iout 0 30 mA Soldering Temperature - - 260 ºC Operating Temperature Topr 0 70 ºC Storage Temperature Tstg -40 85 ºC Note 10 seconds on leads only Recommended Operating Condition Parameter Symbol Min. Typ. Max. Unit Power Supply Voltage Vcc 3.1 3.3 3.5 V Operating Temperature (Case) Topr 0 - 70 ºC - - 1250 - Mbps Data Rate Transmitter Specifications Parameter Optical Optical Transmit Power Symbol Min Typical Max Unit Notes Po -10 - -4 dBm Output power is coupled into a 9/125 µm single mode fiber λ 1260 1310 1360 nm Output Spectrum Width ∆λ - - 3 nm Extinction Ratio ER 9 - - dB ns 20% to 80% Values Output center Wavelength Output Eye Compliant with IEEE 802.3z Optical Rise Time tr Optical Fall Time Optical Isolation Optical Return Loss Relative Intensity Noise Total Jitter LUMINENTOIC.COM RMS (σ) - - 0.26 tf - - 0.26 ns 20% to 80% Values - 30 - - dB Tx:1310 nm/ Rx:1550 nm - 14 - - dB RIN - - -120 dB/Hz TJ - - 0.27 ns Measured with 27-1 PRBS 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS589-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-13/15-1250(C)-TPM3-SXX-60 Transmitter Specifications Parameter Electrical Symbol Min Typical Max Unit Power Supply Current ICC - - 150 mA Data Input Current-Low IIL -350 - - µA Data Input Current-High IIH - - 350 µA Differential Input Voltage VIH-VIL 300 - - mV Data Input Voltage-Low VIL-VCC -2.0 - -1.58 V Data Input Voltage-High VIH-VCC -1.1 - -0.74 V Symbol Min Typical Max Unit - - - -22 dBm Pin -3 - - dBm Notes Maximum current is specified at Vcc= Maximum @ maximum temperature These inputs are compatible with 10K, 10KH and 100K ECL and PECL inputs Receiver Specifications Parameter Optical Sensitivity Maximum Input Power Notes Measured with 27-1 PRBS, BER = 10-12 Signal Detect-Asserted Pa - - -22 dBm Measured on transition: low to high Signal Detect-Deasserted Pd -35 - - dBm Measured on transition: high to low - 3.0 - dB - - -33 dB 1500 - 1600 nm Min Typical Max Unit Note The current excludes the output load current Signal Detect-Hysteresis Cross Talk - Wavelength of Operation Receiver Specifications Parameter Electrical Symbol Power Supply Current Data Output Voltage-Low ICC - - 100 mA VOL -Vcc -1.9 - -1.6 V Data Output Voltage-High VOH- Vcc -1.1 - -0.8 V Signal Detect Output Voltage-Low VSDL-Vcc VSDH- Vcc VSDL -1.9 - -1.6 V -1.1 - -0.8 V 2 - 0.5 - V V Signal Detect Output Voltage-High Signal Detect Output Voltage-Low Signal Detect Output Voltage-High LUMINENTOIC.COM VSDH These outputs are compatible with 10K, 10KH and 100KECL and PECL outputs B-15/13-1250-TDPM3-SXX-60 B-15/13-1250C-TDPM3-SXX-60 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS589-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-13/15-1250(C)-TPM3-SXX-60 Connection Diagram 1. (Rx GND) 2. (Rx +) 3. (Rx-) 4. (SD) 5. (Rx Vcc) 6. (Tx Vcc) 7. (TX-) 8. (TX+) 9. (Tx GND) NC Top View NC Receiver Signal Ground Receiver Data Out Receiver Data Out Bar Signal Detect Receiver Power Supply Transmitter Power Supply Transmitter Data In Bar Transmitter Data in Transmitter Signal Ground PIN Symbol Notes 1 RxGND 2 RD+ See recommended circuit schematic 3 RD- See recommended circuit schematic 4 SD Active high on this indicates a received optical signal 5 RxVcc +3.3V dc power for the receiver section 6 TxVcc +3.3V dc power for the transmitter section Directly connect this pin to the receiver ground plane 7 TD- See recommended circuit schematic 8 Warnings TD+ See recommended circuit schematic 9 LUMINENTOIC.COM TxGND Directly connect this pin to the transmitter ground plane 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS589-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-13/15-1250(C)-TPM3-SXX-60 Recommended Circuit Schematic B-13/15-1250-TPM3-SXX-60 Tx Vcc C5 Rx Vcc 9 R1 8 7 6 5 4 3 2 1 R3 R9 R5 C6 R7 TD + RD + TD - RD - Tx Vcc SD Rx Vcc R2 R4 No internal connection No internal connection Transceiver Top view R10 R6 R8 L1 Vcc Notes +3.3V: R1=R3=R5=R7=R9=130! R2=R4=R6=R8=R10=82! C1=C2=C3=C5=C6=0.1"F C4=10"F L1=L2=1"H Rx Vcc C1 C3 L2 Tx Vcc C2 C4 B-13/15-1250C-TPM3-SXX-60 Tx Vcc C5 Rx Vcc 9 R1 8 7 6 5 4 3 2 1 R5 R3 C6 R7 TD + RD + TD - RD - Tx Vcc SD Rx Vcc R2 R6 R4 No internal connection No internal connection Transceiver Top view R8 L1 Vcc Notes +3.3V: R1=R3=R5=R7=130! R2=R4=R6=R8=82! C1=C2=C3=C5=C6=0.1"F C4=10"F L1=L2=1"H C3 Rx Vcc C1 L2 C4 Tx Vcc C2 The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance. LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS589-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-13/15-1250(C)-TPM3-SXX-60 Package Diagram B-13/15-1250(C)-TPM3-SXX -60 Diplexer Transceiver Assembly Top View Front View max Side View Rear View Units in mm (inch) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS589-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-13/15-1250(C)-TPM3-SXX-60 Ordering Information Available Options: B-13/15-1250(C)-TPM3-SSC-60 B-13/15-1250(C)-TPM3-SST-60 B-13/15-1250(C)-TPM3-SFC-60 B-13/15-1250(C)-TPM3-SMU-60 B - 13/15 - 1250(C) - TPM3 - S XX -60 • Wavelength Tx Wavelength=1310nm Rx Wavelength=1550nm • Communication protocol (1250 Mbps) 1250=LVPECL Signal Detection Output 1250C=LVTTL Signal Detection Output • +3.3 V Transceiver • Single mode fiber • Connector options (SC/ST/FC/MU) • Length of Pigtail Fiber = 660 ± 20 mm Warnings Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notice IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS589-AUG1804 rev. A.0