ETC 30KPA64A

05113
30KPA30A
thru
30KPA280A
. . . engineered solutions for the transient environment™
POWER TVS COMPONENT
APPLICATIONS
✔ Relay Drives
✔ Motor (Start/Stop) Back EMF Protection
✔ Module Lightning Protection
IEC COMPATIBILITY (EN61000-4)
✔ 61000-4-5 (Surge): 8/20µs - 95A, L4 (Line-Gnd), 167A, L3 (Power) & 48A, L4 (Line-Line)
FEATURES
AXIAL LEAD
✔ 30,000 Watts Peak Pulse Power per Line (10/1000µs)
✔ Unidirectional & Bidirectional Configurations
✔ Easy Mounting to Printed Circuit Boards
✔ Available in Voltage Types Ranging From: 30V to 280V
MECHANICAL CHARACTERISTICS
✔ Molded Case
✔ Weight 2.5 grams (Approximate)
✔ Flammability Rating UL 94V-0
✔ Positive Terminal Marked with Band - Unidirectional Devices
✔ Marking: Logo & Part Number
APPLICATION
TYPICAL RELAY DRIVE PROTECTION
VCC
05113.R7 9/02
1
www.protekdevices.com
30KPA30A
thru
30KPA280A
DEVICE CHARACTERISTICS
MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PARAMETER
SYMBOL
VALUE
UNITS
PPP
30,000
Watts
Forward Surge Rating (1/20 seconds) - See Note 2
IF
200
Amps
Steady State Power Dissipation
PD
1.0
Watts
TSTG
-55 to +150
Peak Pulse Power Dissipation (tp =10/1000µs) - See Fig. 1
Storage Temperature
Operating Temperature
TJ
-55 to +150
0
C
0
C
ELECTRICAL CHARACTERISTICS
PART
NUMBER
(Notes 1 & 2)
30KPA30A
30KPA36A
30KPA43A
30KPA48A
30KPA64A
30KPA70A
30KPA75A
30KPA90A
30KPA160A
30KPA180A
30KPA260A
30KPA280A
RATED
STAND-OFF
VOLTAGE
BREAKDOWN
VOLTAGE
MAXIMUM
LEAKAGE
CURRENT
MAXIMUM
CLAMPING
VOLTAGE
(See Fig. 2)
TEMPERATURE
COEFFICIENT
OF V(BR)
VWM
VOLTS
MIN
V(BR)
VOLTS
@IT
mA
@VWM
ID
µA
@ 10/1000µs
VC @ IPP
θV(BR)
mV/°C
30.0
36.0
43.0
48.0
64.0
70.0
75.0
90.0
160.0
180.0
260.0
280.0
33.3
40.0
47.8
53.3
71.1
77.8
83.3
100.0
178.0
200.0
289.0
311.0
50
50
50
5
5
5
5
5
5
5
5
5
5000
2000
1000
250
10
10
10
10
10
10
10
10
55.2V @ 543.0A
61.8V @ 485.0A
73.0V @ 410.0A
77.4V @ 388.0A
104.0V @ 294.0A
109.0V @ 274.0A
119.4V @ 251.0A
147.0V @ 206.0A
252.6V @ 119.0A
291 @ 104A
416.0V @ 72.0A
464.0V @ 65.0A
34
41
50
56
76
83
89
109
195
230
317
342
Note 1: Part numbers shown are unidirectional devices. Add a “CA” suffix to specify bidirectional devices, such as 30KPA30CA. Devices shown
are preferred voltages. Contact factory for additional voltages.
Note 2: VF = 15 Volts @ 200A, 8.3ms (1/2 Sine Wave) - unidirectional devices only.
05113.R7 9/02
2
www.protekdevices.com
30KPA30A
thru
30KPA280A
GRAPHS
FIGURE 1
PEAK PULSE POWER VS PULSE TIME
PPP - Peak Pulse Power - kilowatts
1,000
30kW 10/1000µs
Waveform
100
10
0
0.1
10
100
1,000
td - Pulse Duration - µs
10,000
FIGURE 2
PULSE WAVE FORM
100
100,000
FIGURE 3
POWER DERATING CURVE
100
tf
Peak Value IPP
TEST
WAVEFORM
PARAMETERS
tf = 10µs
td = 1,000µs
Peak Pulse Power
10/1000µs
80
% Of Rated Power
IPP - Peak Pulse Current - % of IPP
1
td = t I /2
PP
50
60
40
20
Average Power
e-t
0
0
0
0
1
2
3
25
50
75
100
125
TL - Lead Temperature - °C
150
t - Time - ms
05113.R7 9/02
3
www.protekdevices.com
30KPA30A
thru
30KPA280A
PACKAGE OUTLINE & DIMENSIONS
PACKAGE OUTLINE
30KPA
A
E
PACKAGE DIMENSIONS
B
DIM
D
A
B
C
D
E
C
MILLIMETERS
MIN
MAX
24.5
8.60
24.5
1.20 DIA
8.60
INCHES
MIN
MAX
1.00
0.34
9.10
0.36
1.00
1.30 DIA 0.048 DIA 0.052 DIA
0.34
9.10
0.36
NOTES:
1. Dimensions are exclusive of mold flash and metal
burrs.
06028 Rev 0 - 12/01
Protek Devices
2929 South Fair Lane, Tempe, AZ 85282
Tel: 602-431-8101 Fax: 602-431-2288
E-Mail: [email protected]
Web Site: www.protekdevices.com
COPYRIGHT © ProTek Devices 2002
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC).
DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and
technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.
05113.R7 9/02
4
www.protekdevices.com