05113 30KPA30A thru 30KPA280A . . . engineered solutions for the transient environment™ POWER TVS COMPONENT APPLICATIONS ✔ Relay Drives ✔ Motor (Start/Stop) Back EMF Protection ✔ Module Lightning Protection IEC COMPATIBILITY (EN61000-4) ✔ 61000-4-5 (Surge): 8/20µs - 95A, L4 (Line-Gnd), 167A, L3 (Power) & 48A, L4 (Line-Line) FEATURES AXIAL LEAD ✔ 30,000 Watts Peak Pulse Power per Line (10/1000µs) ✔ Unidirectional & Bidirectional Configurations ✔ Easy Mounting to Printed Circuit Boards ✔ Available in Voltage Types Ranging From: 30V to 280V MECHANICAL CHARACTERISTICS ✔ Molded Case ✔ Weight 2.5 grams (Approximate) ✔ Flammability Rating UL 94V-0 ✔ Positive Terminal Marked with Band - Unidirectional Devices ✔ Marking: Logo & Part Number APPLICATION TYPICAL RELAY DRIVE PROTECTION VCC 05113.R7 9/02 1 www.protekdevices.com 30KPA30A thru 30KPA280A DEVICE CHARACTERISTICS MAXIMUM RATINGS @ 25°C Unless Otherwise Specified PARAMETER SYMBOL VALUE UNITS PPP 30,000 Watts Forward Surge Rating (1/20 seconds) - See Note 2 IF 200 Amps Steady State Power Dissipation PD 1.0 Watts TSTG -55 to +150 Peak Pulse Power Dissipation (tp =10/1000µs) - See Fig. 1 Storage Temperature Operating Temperature TJ -55 to +150 0 C 0 C ELECTRICAL CHARACTERISTICS PART NUMBER (Notes 1 & 2) 30KPA30A 30KPA36A 30KPA43A 30KPA48A 30KPA64A 30KPA70A 30KPA75A 30KPA90A 30KPA160A 30KPA180A 30KPA260A 30KPA280A RATED STAND-OFF VOLTAGE BREAKDOWN VOLTAGE MAXIMUM LEAKAGE CURRENT MAXIMUM CLAMPING VOLTAGE (See Fig. 2) TEMPERATURE COEFFICIENT OF V(BR) VWM VOLTS MIN V(BR) VOLTS @IT mA @VWM ID µA @ 10/1000µs VC @ IPP θV(BR) mV/°C 30.0 36.0 43.0 48.0 64.0 70.0 75.0 90.0 160.0 180.0 260.0 280.0 33.3 40.0 47.8 53.3 71.1 77.8 83.3 100.0 178.0 200.0 289.0 311.0 50 50 50 5 5 5 5 5 5 5 5 5 5000 2000 1000 250 10 10 10 10 10 10 10 10 55.2V @ 543.0A 61.8V @ 485.0A 73.0V @ 410.0A 77.4V @ 388.0A 104.0V @ 294.0A 109.0V @ 274.0A 119.4V @ 251.0A 147.0V @ 206.0A 252.6V @ 119.0A 291 @ 104A 416.0V @ 72.0A 464.0V @ 65.0A 34 41 50 56 76 83 89 109 195 230 317 342 Note 1: Part numbers shown are unidirectional devices. Add a “CA” suffix to specify bidirectional devices, such as 30KPA30CA. Devices shown are preferred voltages. Contact factory for additional voltages. Note 2: VF = 15 Volts @ 200A, 8.3ms (1/2 Sine Wave) - unidirectional devices only. 05113.R7 9/02 2 www.protekdevices.com 30KPA30A thru 30KPA280A GRAPHS FIGURE 1 PEAK PULSE POWER VS PULSE TIME PPP - Peak Pulse Power - kilowatts 1,000 30kW 10/1000µs Waveform 100 10 0 0.1 10 100 1,000 td - Pulse Duration - µs 10,000 FIGURE 2 PULSE WAVE FORM 100 100,000 FIGURE 3 POWER DERATING CURVE 100 tf Peak Value IPP TEST WAVEFORM PARAMETERS tf = 10µs td = 1,000µs Peak Pulse Power 10/1000µs 80 % Of Rated Power IPP - Peak Pulse Current - % of IPP 1 td = t I /2 PP 50 60 40 20 Average Power e-t 0 0 0 0 1 2 3 25 50 75 100 125 TL - Lead Temperature - °C 150 t - Time - ms 05113.R7 9/02 3 www.protekdevices.com 30KPA30A thru 30KPA280A PACKAGE OUTLINE & DIMENSIONS PACKAGE OUTLINE 30KPA A E PACKAGE DIMENSIONS B DIM D A B C D E C MILLIMETERS MIN MAX 24.5 8.60 24.5 1.20 DIA 8.60 INCHES MIN MAX 1.00 0.34 9.10 0.36 1.00 1.30 DIA 0.048 DIA 0.052 DIA 0.34 9.10 0.36 NOTES: 1. Dimensions are exclusive of mold flash and metal burrs. 06028 Rev 0 - 12/01 Protek Devices 2929 South Fair Lane, Tempe, AZ 85282 Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: [email protected] Web Site: www.protekdevices.com COPYRIGHT © ProTek Devices 2002 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products. 05113.R7 9/02 4 www.protekdevices.com