TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 D D D D D D D D, N OR PW PACKAGE (TOP VIEW) Two Complete PWM Control Circuits Outputs Drive MOSFETs Directly Oscillator Frequency . . . 50 kHz to 2 MHz 3.6-V to 20-V Supply-Voltage Range Low Supply Current . . . 3.5 mA Typ Adjustable Dead-Time Control, 0% to 100% 1.26-V Reference CT RT DTC1 IN1 + IN1 – COMP1 GND OUT1 description 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 REF SCP DTC2 IN2 + IN2 – COMP2 VCC OUT2 The TL1454A is a dual-channel pulse-width-modulation (PWM) control circuit, primarily intended for low-power, dc/dc converters. Applications include LCD displays, backlight inverters, notebook computers, and other products requiring small, high-frequency, dc/dc converters. Each PWM channel has its own error amplifier, PWM comparator, dead-time control comparator, and MOSFET driver. The voltage reference, oscillator, undervoltage lockout, and short-circuit protection are common to both channels. Channel 1 is configured to drive n-channel MOSFETs in step-up or flyback converters, and channel 2 is configured to drive p-channel MOSFETs in step-down or inverting converters. The operating frequency is set with an external resistor and an external capacitor, and dead time is continuously adjustable from 0 to 100% duty cycle with a resistive divider network. Soft start can be implemented by adding a capacitor to the dead-time control (DTC) network. The error-amplifier common-mode input range includes ground, which allows the TL1454A to be used in ground-sensing battery chargers as well as voltage converters. AVAILABLE OPTIONS PACKAGED DEVICES† TA SMALL OUTLINE (D) PLASTIC DIP (N) TSSOP (PW) SSOP (DB) SOP-EIAJ (NS) CHIP FORM (Y) – 20°C to 85°C TL1454ACD TL1454ACN TL1454ACPWR TL1454ACDB TL1454ACNS TL1454AY † The D, DB and NS packages are available taped and reeled. Add the suffix R to the device name (e.g., TL1454ACDR). The PW package is available only left-end taped and reeled (indicated by the R suffix on the device type; e.g., TL1454ACPWR). Copyright 2002, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 functional block diagram VCC 10 Voltage REF GND COMP1 IN1 + IN1 – RT CT 2 1 1.26 V 2.5 V 7 16 1.2 V OSC 5 VCC PWM Comparator 1 6 4 REF 1.8 V To Internal Circuitry + _ 8 OUT1 Error Amplifier 1 PWM Comparator 2 COMP2 11 13 + IN2 + 12 _ IN2 – Error Amplifier 2 VCC UVLO and SCP Latch 9 SCP Comparator 2 1V 1V SCP Comparator 1 0.65 V 0.65 V 1.27 V 15 SCP 2 POST OFFICE BOX 655303 3 14 DTC1 DTC2 • DALLAS, TEXAS 75265 OUT2 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 TL1454AY chip information This device, when properly assembled, displays characteristics similar to the TL1454AC. Thermal compression or ultrasonic bonding may be used on the doped aluminum bonding pads. The chips may be mounted with conductive epoxy or a gold-silicon preform. BONDING PAD ASSIGNMENTS (15) (14) (13) (12) (11) (10) (9) (16) 86 (8) (1) (2) (4) (3) (5) (6) (7) 108 CT RT DTC1 IN1 + IN1– COMP1 GND OUT1 (1) (16) (2) (15) (3) (14) (4) (13) (5) TL1454AY (12) (6) (11) (7) (10) (8) (9) REF SCP CHIP THICKNESS: 15 TYPICAL DTC2 BONDING PADS: 4 × 4 MINIMUM IN2+ TJmax = 150°C IN2 – TOLERANCES ARE ± 10%. COMP2 ALL DIMENSIONS ARE IN MILS. VCC OUT2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 theory of operation reference voltage A linear regulator operating from VCC generates a 2.5-V supply for the internal circuits and the 1.26-V reference, which can source a maximum of 1 mA for external loads. A small ceramic capacitor (0.047 µF to 0.1 µF) between REF and ground is recommended to minimize noise pickup. error amplifier The error amplifier generates the error signal used by the PWM to adjust the power-switch duty cycle for the desired converter output voltage. The signal is generated by comparing a sample of the output voltage to the voltage reference and amplifying the difference. An external resistive divider connected between the converter output and ground, as shown in Figure 1, is generally required to obtain the output voltage sample. The amplifier output is brought out on COMP to allow the frequency response of the amplifier to be shaped with an external RC network to stabilize the feedback loop of the converter. DC loading on the COMP output is limited to 45 µA (the maximum amplifier source current capability). Figure 1 illustrates the sense-divider network and error-amplifier connections for converters with positive output voltages. The divider network is connected to the noninverting amplifier input because the PWM has a phase inversion; the duty cycle decreases as the error-amplifier output increases. TL1454A REF COMP Compensation Network R3 Converter Output IN – IN + VO R1 _ To PWM + R2 Figure 1. Sense Divider/Error Amplifier Configuration for Converters with Positive Outputs The output voltage is given by: V O +V ref ǒ1 ) R1 Ǔ R2 where Vref = 1.26 V. The dc source resistance of the error-amplifier inputs should be 10 kΩ or less and approximately matched to minimize output voltage errors caused by the input-bias current. A simple procedure for determining appropriate values for the resistors is to choose a convenient value for R3 (10 kΩ or less) and calculate R1 and R2 using: R1 + R2 + 4 R 3V O V –V O ref R 3V V O ref POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 error amplifier R1 and R2 should be tight-tolerance (±1% or better) devices with low and/or matched temperature coefficients to minimize output voltage errors. A device with a ±5% tolerance is suitable for R3. REF COMP R2 Compensation Network IN – IN + R1 _ To PWM + R3 Converter V Output O Figure 2. Sense Divider/Error Amplifier Configuration for Converters with Negative Outputs Figure 2 shows the divider network and error-amplifier configuration for negative output voltages. In general, the comments for positive output voltages also apply for negative outputs. The output voltage is given by: V R V + * 1 ref O R2 The design procedure for choosing the resistor value is to select a convenient value for R2 (instead of R3 in the procedure for positive outputs) and calculate R1 and R3 using: R V R1 + * 2 O V ref R3 + R 1R 2 R1 ) R2 Values in the 10-kΩ to 20-kΩ range work well for R2. R3 can be omitted and the noninverting amplifier connected to ground in applications where the output voltage tolerance is not critical. oscillator The oscillator frequency can be set between 50 kHz and 2 MHz with a resistor connected between RT and GND and a capacitor between CT and GND (see Figure 3). Figure 6 is used to determine RT and CT for the desired operating frequency. Both components should be tight-tolerance, temperature-stable devices to minimize frequency deviation. A 1% metal-film resistor is recommended for RT, and a 10%, or better, NPO ceramic capacitor is recommended for CT. TL1454A RT CT 2 1 RT CT Figure 3. Oscillator Timing POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 dead-time control (DTC) and soft start The two PWM channels have independent dead-time control inputs so that the maximum power-switch duty cycles can be limited to less then 100%. The dead-time is set with a voltage applied to DTC; the voltage is typically obtained from a resistive divider connected between the reference and ground as shown in Figure 4. Soft start is implemented by adding a capacitor between REF and DTC. The voltage, VDT, required to limit the duty cycle to a maximum value is given by: V DT +V O(max) ǒ *D V O(max) *V O(min) Ǔ * 0.65 where VO(max) and VO(min) are obtained from Figure 9, and D is the maximum duty cycle. Predicting the regulator startup or rise time is complicated because it depends on many variables, including: input voltage, output voltage, filter values, converter topology, and operating frequency. In general, the output will be in regulation within two time constants of the soft-start circuit. A five-to-ten millisecond time constant usually works well for low-power converters. The DTC input can be grounded in applications where achieving a 100% duty cycle is desirable, such as a buck converter with a very low input-to-output differential voltage. However, grounding DTC prevents the implementation of soft start, and the output voltage overshoot at power-on is likely to be very large. A better arrangement is to omit RDT1 (see Figure 4) and choose RDT2 = 47 kΩ. This configuration ensures that the duty cycle can reach 100% and still allows the designer to implement soft start using CSS. 16 REF TL1454A RDT1 CSS DTC RDT2 Figure 4. Dead-Time Control and Soft Start PWM comparator Each of the PWM comparators has dual inverting inputs. One inverting input is connected to the output of the error amplifier; the other inverting input is connected to the DTC terminal. Under normal operating conditions, when either the error-amplifier output or the dead-time control voltage is higher than that for the PWM triangle wave, the output stage is set inactive (OUT1 low and OUT2 high), turning the external power stage off. undervoltage-lockout (UVLO) protection The undervoltage-lockout circuit turns the output circuit off and resets the SCP latch whenever the supply voltage drops too low (to approximately 2.9 V) for proper operation. A hysteresis voltage of 200 mV eliminates false triggering on noise and chattering. short-circuit protection (SCP) The TL1454A SCP function prevents damage to the power switches when the converter output is shorted to ground. In normal operation, SCP comparator 1 clamps SCP to approximately 185 mV. When one of the converter outputs is shorted, the error amplifier output (COMP) will be driven below 1 V to maximize duty cycle and force the converter output back up. When the error amplifier output drops below 1 V, SCP comparator 1 releases SCP, and capacitor, CSCP, which is connected between SCP and GND, begins charging. If the error-amplifier output rises above 1 V before CSCP is charged to 1 V, SCP comparator 1 discharges CSCP and normal operation resumes. If CSCP reaches 1 V, SCP comparator 2 turns on and sets the SCP latch, which turns off the output drives and resets the soft-start circuit. The latch remains set until the supply voltage is lowered to 2 V or less, or CSCP is discharged externally. 6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 short-circuit protection (SCP) (continued) The SCP time-out period must be greater than the converter start-up time or the converter will not start. Because high-value capacitor tolerances tend to be ± 20% or more and IC resistor tolerances are loose as well, it is best to choose an SCP time-out period 10-to-15 times greater than the converter startup time. The value of CSCP may be determined using Figure 6, or it can be calculated using: T C SCP + SCP 80.3 where CSCP is in µF and TSCP is the time-out period in ms. output stage The output stage of the TL1454A is a totem-pole output with a maximum source/sink current rating of 40 mA and a voltage rating of 20 V. The output is controlled by a complementary output AND gate and is turned on (sourcing current for OUT1, sinking current for OUT2) when all the following conditions are met: 1) the oscillator triangle wave voltage is higher than both the DTC voltage and the error-amplifier output voltage, 2) the undervoltage-lockout circuit is inactive, and 3) the short-circuit protection circuit is inactive. absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 V Error amplifier input voltage: IN1+, IN1 –, IN2 +, IN2 – . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 V Output voltage: OUT1, OUT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V Continuous output current: OUT1, OUT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 200 mA Peak output current: OUT1, OUT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A Continuous total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table Operating free-air temperature range, TA: C suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 20°C to 85°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: All voltage values are with respect to network GND. DISSIPATION RATING TABLE PACKAGE TA ≤ 25°C POWER RATING DERATING FACTOR ABOVE TA = 25°C TA = 70°C POWER RATING TA = 85°C POWER RATING D 950 mW 7.6 mW/°C 608 mW 494 mW DB 1000 mW 8.0 mW/°C 640 mW 520 mW N 1250 mW 10.0 mW/°C 800 mW 650 mW NS 1953 mW 15.6 mW/°C 1250 mW 1015 mW PW 500 mW 4.0 mW/°C 320 mW 260 mW POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 recommended operating conditions Supply voltage, VCC Error amplifier common-mode input voltage MIN MAX 3.6 20 UNIT V – 0.2 1.45 V Output voltage, VO 20 V Output current, IO ± 40 mA COMP source current – 45 µA COMP sink current 100 µA 1 mA Reference output current COMP dc load resistance 100 kΩ Timing capacitor, CT 10 Timing resistor, RT 5.1 100 kΩ Oscillator frequency 50 2000 kHz – 20 85 °C Operating free-air temperature, TA TL1454AC 4000 pF electrical characteristics over recommended operating free-air temperature range, VCC = 6 V, fosc = 500 kHz (unless otherwise noted) reference TL1454A PARAMETER Vref TEST CONDITIONS Output voltage voltage, REF Input regulation Output regulation Output voltage change with temperature IOS Short-circuit output current IO = 1 mA, IO = 1 mA TA = 25°C VOC = 3.6 V to 20 V, IO = 0.1 mA to 1 mA IO = 1 mA TA = TA(min) to 25°C, IO = 1 mA TA = 25°C to 85°C, Vref = 0 V IO = 1 mA MIN TYP MAX 1.22 1.26 1.32 1.20 1.34 UNIT V 2 6 mV 1 7.5 mV –12.5 – 1.25 12.5 –12.5 –2.5 12.5 30 mV mA undervoltage lockout (UVLO) TL1454A PARAMETER VIT + VIT – Positive-going threshold voltage Vhys Hysteresis, VIT + – VIT – TEST CONDITIONS MIN TYP MAX 2.9 Negative-going threshold voltage TA = 25 25°C C 100 UNIT V 2.7 V 200 mV short-circuit protection (SCP) TL1454A PARAMETER VIT Vstby† Input threshold voltage VI(latched) Latched-mode input voltage VIT(COMP) Comparator threshold voltage TEST CONDITIONS TA = 25°C Standby voltage MAX 0.93 1 1.07 V 140 185 230 mV 60 120 mV COMP1, COMP2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 UNIT TYP No pullup Input source current TA = 25°C, VO(SCP) = 0 † This symbol is not presently listed within EIA / JEDEC standards for semiconductor symbology. 8 MIN 1 –5 – 15 V – 20 µA TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 electrical characteristics over recommended operating free-air temperature range, VCC = 6 V, fosc = 500 kHz (unless otherwise noted) (continued) oscillator TL1454A PARAMETER fosc TEST CONDITIONS Frequency CT = 120 pF, MIN RT = 10 kΩ Standard deviation of frequency Frequency change with voltage Frequency change with temperature VCC = 3.6 V to 20 V, TA = TA(min) to 25°C TA = 25°C TYP MAX 500 kHz 50 kHz 10 TA = 25°C to 85°C UNIT kHz –2 ± 30 – 10 ± 30 kHz Maximum ramp voltage 1.8 V Minimum ramp voltage 1.1 V dead-time control (DTC) TL1454A PARAMETER VIT Input threshold voltage VI(latched) IIB Latched-mode input voltage TEST CONDITIONS MIN TYP MAX Duty cycle = 0% 0.98 1.1 1.22 Duty cycle = 100% 0.38 0.5 0.62 1.2 Common-mode input bias current DTC1, IN1+ ≈ 1.2 V Latched-mode (source) current TA = 25°C UNIT V V 4 µA µA – 100 error-amplifier TL1454A PARAMETER VIO IIO Input offset voltage IIB VICR Input bias current AV Open-loop voltage gain Input offset current Input voltage range TEST CONDITIONS VO = 1.25 V, MIN TYP VIC = 1.25 V – 160 VCC = 3.6 V to 20 V RFB = 200 kΩ 70 nA nA dB 3 MHz dB Common-mode rejection ratio 60 80 Positive output voltage swing 2.3 2.43 IO + IO – Output sink current 0.63 VO = 1.20 V VO = 1.80 V 100 – 500 80 VOM(max) VOM(min) VID = – 0.1 V, VID = 0.1 V, mV V CMRR Negative output voltage swing UNIT 6 – 0.2 to 1.40 Unity-gain bandwidth Output source current MAX 0.8 V 0.1 0.5 mA – 45 – 70 µA output TL1454A PARAMETER VOH High level output voltage High-level VOL Low level output voltage Low-level trv tfv Output voltage rise time Output voltage fall time TEST CONDITIONS IO = – 8 mA IO = –8 mA @ VCC = >10 V IO = – 40 mA IO = 40 mA @ VCC = >10 V IO = 8 mA IO = 40 mA CL = 2000 pF pF, POST OFFICE BOX 655303 TA = 25°C • DALLAS, TEXAS 75265 MIN TYP VCC–2 VCC–2.3 V VCC–2 4.5 MAX UNIT V 4.4 VCC–2.3 V 0.1 0.4 1.8 2.5 220 220 V ns 9 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 electrical characteristics over recommended operating free-air temperature range, VCC = 6 V, fosc = 500 kHz (unless otherwise noted) (continued) supply current TL1454A PARAMETER ICC(stby) Standby supply current ICC(average) Average supply current TEST CONDITIONS MIN RT open, CT = 1.5 V, No load, VO (COMP1, COMP2) = 1.25 V, RT = 10 kΩ, CT = 120 pF, 50% duty cycle, Outputs open UNIT TYP MAX 3.1 6 mA 3.5 7 mA electrical characteristics, VCC = 6 V, fosc = 500 kHz, TA = 25°C (unless otherwise noted) reference TL1454AY PARAMETER Vref TEST CONDITIONS Output voltage, REF IO = 1 mA VOC = 3.6 V to 20 V, Input regulation Output regulation Output voltage change with temperature IOS Short-circuit output current MIN TYP MAX 1.26 IO = 1 mA IO = 0.1 mA to 1 mA IO = 1 mA V 2 mV 1 mV – 1.25 IO = 1 mA Vref = 0 V UNIT mV –2.5 30 mA undervoltage lockout (UVLO) TL1454AY PARAMETER TEST CONDITIONS MIN TYP MAX 2.9 UNIT VIT + VIT – Positive-going threshold voltage V Negative-going threshold voltage 2.7 V Vhys Hysteresis, VIT + – VIT – 200 mV short-circuit protection (SCP) TL1454AY PARAMETER VIT Vstby† Input threshold voltage VI(latched) VIT(COMP) Latched-mode input voltage TEST CONDITIONS MIN TYP MAX 1 Standby voltage No pullup Comparator threshold voltage COMP1, COMP2 Input source current VO(SCP) = 0 † This symbol is not presently listed within EIA / JEDEC standards for semiconductor symbology. UNIT V 185 mV 60 mV 1 V – 15 µA oscillator TL1454AY PARAMETER fosc TEST CONDITIONS Frequency CT = 120 pF, RT = 10 kΩ Standard deviation of frequency Frequency change with voltage Frequency change with temperature 10 VCC = 3.6 V to 20 V TA = TA(min) to 25°C TA = 25°C to 85°C MIN TYP MAX UNIT 500 kHz 50 kHz 10 kHz –2 – 10 kHz Maximum ramp voltage 1.8 V Minimum ramp voltage 1.1 V POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 electrical characteristics, VCC = 6 V, fosc = 500 kHz, TA = 25°C (unless otherwise noted) (continued) dead-time control (DTC) TL1454AY PARAMETER VIT Input threshold voltage VI(latched) Latched-mode input voltage TEST CONDITIONS MIN TYP Duty cycle = 0% 1.1 Duty cycle = 100% 0.5 Latched-mode (source) current MAX UNIT V 1.2 V – 100 µA error-amplifier TL1454AY PARAMETER IIB AV Input bias current Open-loop voltage gain TEST CONDITIONS VO = 1.25 V, RFB = 200 kΩ MIN VIC = 1.25 V Unity-gain bandwidth TYP MAX UNIT – 160 nA 80 dB 3 MHz CMRR Common-mode rejection ratio 80 dB VOM(max) VOM(min) Positive output voltage swing 2.43 Negative output voltage swing 0.63 IO + IO – Output sink current Output source current VID = – 0.1 V, VID = 0.1 V, VO = 1.20 V VO = 1.80 V V 0.5 mA – 70 µA output TL1454AY PARAMETER TEST CONDITIONS MIN TYP High level output voltage High-level IO = – 8 mA IO = – 40 mA 4.5 VOH Low level output voltage Low-level IO = 8 mA IO = 40 mA 0.1 VOL trv tfv Output voltage rise time Output voltage fall time MAX V 4.4 V 1.8 220 CL = 2000 pF UNIT ns 220 supply current TL1454AY PARAMETER TEST CONDITIONS MIN TYP MAX UNIT ICC(stby) Standby supply current RT open, CT = 1.5 V, No load, VO (COMP1, COMP2) = 1.25 V, 3.1 mA ICC(average) Average supply current RT = 10 kΩ, 50% duty cycle, 3.5 mA POST OFFICE BOX 655303 CT = 120 pF, Outputs open • DALLAS, TEXAS 75265 11 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 PARAMETER MEASUREMENT INFORMATION Oscillator COMP DTC 1.8 V 1.2 V 1V SCP Reference OUT1 H Dead-Time 100% L OUT2 H Dead-Time 100% L H SCP Comparator Output L 2.5 V 1V 0V SCP (tpe) VCC 2.9-V Typical Lockout threshold 0V Figure 5. Timing Diagram 12 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 TYPICAL CHARACTERISTICS OSCILLATOR FREQUENCY vs TIMING RESISTANCE 10 2 10 M VCC = 6 V RT = 5.1 kΩ TA = 25°C CT = 10 pF 1M t – Oscillation Period – µ s f – Oscillator Frequency – Hz VCC = 6 V TA = 25°C CT = 120 pF CT = 300 pF 100 k CT = 1000 pF CT = 3900 pF 10 k OSCILLATOR PERIOD vs TIMING CAPACITANCE 10 1 10 0 10 – 1 1k 1k 10 k 10 0 100 k RT – Timing Resistance – Ω 10 1 PWM TRIANGLE WAVEFORM AMPLITUDE vs TIMING CAPACITANCE 2 1.9 VCC = 6 V RT = 10 kΩ CT = 120 pF PWM Triangle Waveform Amplitude – V f osc – Oscillator Frequency – kHz 530 510 500 490 0 10 5 10 4 Figure 7 OSCILLATOR FREQUENCY vs FREE-AIR TEMPERATURE 480 – 50 10 3 CT – Timing Capacitance – pF Figure 6 520 10 2 50 100 VO(max) 1.8 1.7 1.6 1.5 1.4 1.3 VO(min) 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 10 0 VCC = 6 V RT = 5.1 kΩ TA = 25°C TA – Free-Air Temperature – °C 10 1 10 2 10 3 10 4 Timing Capacitance – pF Figure 8 Figure 9 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 13 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 TYPICAL CHARACTERISTICS DTC INPUT THRESHOLD VOLTAGE vs FREE-AIR TEMPERATURE 2 VCC = 6 V RT = 5.1 kΩ CT = 1000 pF VCC = 6 V TA = 25°C 1.2 t SCP – SCP Time-Out Period – s DTC Input Threshold Voltage – V 1.4 SCP TIME-OUT PERIOD vs SCP CAPACITANCE VIT (0% Duty Cycle) 1 0.8 0.6 VIT (100% Duty Cycle) 1.5 1 0.5 0 0.4 – 50 0 50 0 100 5 10 TA – Free-Air Temperature – °C Figure 11 SCP THRESHOLD VOLTAGE vs FREE-AIR TEMPERATURE SCP LATCH RESET VOLTAGE vs FREE-AIR TEMPERATURE 3.5 VCC = 6 V VCC = 6 V VI(reset) – SCP Latch Reset Voltage – V VIT – SCP Threshold Voltage – V 1.04 1.02 1 0.98 0.96 0 50 100 3 2.5 2 1.5 1 – 50 – 25 TA – Free-Air Temperature – °C 0 25 Figure 13 POST OFFICE BOX 655303 50 75 TA – Free-Air Temperature – °C Figure 12 14 25 SCP Capacitance – µF Figure 10 0.94 – 50 20 15 • DALLAS, TEXAS 75265 100 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 TYPICAL CHARACTERISTICS UVLO THRESHOLD VOLTAGE vs FREE-AIR TEMPERATURE DUTY CYCLE vs DTC INPUT VOLTAGE 120 VCC = 6 V CT = 120 pF RT = 10 kΩ TA = 25°C VIT(H) 100 3 VIL(L) 80 2.5 Duty Cycle – % VIT(H) VIT(L) – UVLO Threshold Voltage – V 3.5 2 60 40 1.5 20 1 – 50 – 25 0 25 50 75 0 100 0.25 0 TA – Free-Air Temperature – °C 0.5 1 1.25 1.5 Figure 15 Figure 14 ERROR-AMPLIFIER MAXIMUM OUTPUT VOLTAGE vs SOURCE CURRENT ERROR-AMPLIFIER MINIMUM OUTPUT VOLTAGE vs SINK CURRENT 2.5 2.5 VCC = 6 V VID = 0.1 V TA = 25°C 2 1.5 1 0.5 0 0 40 120 80 VOM – – Error-Amplifier Minimum Output Voltage – V VOM + – Error-Amplifier Maximum Output Voltage – V 0.75 VI(DTC) – DTC Input Voltage – V VCC = 6 V VID = 0.1 V 2 1.5 1 0.5 0 0 Source Current – µA Figure 16 0.5 1 Sink Current – mA 1.5 Figure 17 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 15 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 TYPICAL CHARACTERISTICS VO(PP) – Error Amplifier Maximum Peak-to-Peak Output Voltage Swing – V 2.5 VCC = 6 V TA = 25°C 2 1.5 1 0.5 0 1k 10 k 100 k 1M 10 M 100 M f – Frequency – Hz ERROR-AMPLIFIER MINIMUM OUTPUT VOLTAGE SWING vs FREE-AIR TEMPERATURE VOM+ – Error-Ampplifier Minimum Output Voltage Swing – V ERROR AMPLIFIER MAXIMUM PEAK-TO-PEAK OUTPUT VOLTAGE SWING vs FREQUENCY 0.8 VCC = 6 V No Load Amplifier 1 0.7 0.6 0.5 0.4 ÁÁ ÁÁ 0.3 – 50 – 25 0 25 50 75 TA – Free-Air Temperature – °C Figure 19 Figure 18 ERROR AMPLIFIER OPEN-LOOP GAIN AND PHASE SHIFT vs FREQUENCY – 0° VCC = 6 V TA = 25°C – 36° 60 Gain – 72° 40 Phase Shift 20 – 108° 0 – 144° – 20 100 1k 10 k 100 k 1M f – Frequency – Hz Figure 20 16 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 – 180° 10 M Phase Shift Error Amplifier Open-Loop Gain – dB 80 100 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 VOM+ – Error-Ampplifier Positive Output Voltage Swing – V TYPICAL CHARACTERISTICS ERROR-AMPLIFIER POSITIVE OUTPUT VOLTAGE SWING vs FREE-AIR TEMPERATURE 2.5 VCC = 6 V No Load Amplifier 1 2.45 2.4 ÁÁ ÁÁ ÁÁ 2.35 – 50 – 25 0 25 50 75 TA – Free-Air Temperature – °C 100 Figure 21 HIGH-LEVEL OUTPUT VOLTAGE vs OUTPUT CURRENT HIGH-LEVEL OUTPUT VOLTAGE vs FREE-AIR TEMPERATURE 6 5.5 VCC = 6 V VOH – High-Level Output Voltage – V VOH – High-Level Output Voltage – V VCC = 6 V TA = 25°C 5 4 3 2 1 0 20 40 60 IO – Output Current – mA 80 5 IO = 8 mA 4.5 IO = 40 mA 4 3.5 3 – 50 – 25 0 25 50 75 TA – Free-Air Temperature – °C 100 Figure 23 Figure 22 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 17 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 TYPICAL CHARACTERISTICS LOW-LEVEL OUTPUT VOLTAGE vs LOW-LEVEL OUTPUT CURRENT LOW-LEVEL OUTPUT VOLTAGE vs FREE-AIR TEMPERATURE 6 250 VOL – Low-Level Output Voltage – mV VOL – Low-Level Output Voltage – V VCC = 6 V TA = 25°C 5 4 3 2 1 0 20 40 60 IOL – Low-Level Output Current – mA VCC = 6 V IO = 8 mA 200 150 100 50 0 – 50 80 – 25 0 25 50 75 TA – Free-Air Temperature – °C Figure 25 Figure 24 LOW-LEVEL OUTPUT VOLTAGE vs FREE-AIR TEMPERATURE AVERAGE SUPPLY CURRENT vs FREE-AIR TEMPERATURE 6 3 I CC(a) – Average Supply Current – mA VOL – Low-Level Output Voltage – V VCC = 6 V IO = 40 mA 2.5 2 1.5 1 0.5 – 50 – 25 0 25 50 75 TA – Free-Air Temperature – °C 100 5 VCC = 6 V RT = 10 kΩ CT = 1.5 V COMP1, COMP2 = 1.25 V No Load 4 3 2 1 – 50 – 25 0 25 Figure 27 POST OFFICE BOX 655303 50 75 TA – Free-Air Temperature – °C Figure 26 18 100 • DALLAS, TEXAS 75265 100 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 TYPICAL CHARACTERISTICS STANDBY SUPPLY CURRENT vs SUPPLY VOLTAGE STANDBY SUPPLY CURRENT vs FREE-AIR TEMPERATURE 6 VCC = 6 V RT = Open CT = 1.5 V COMP1, COMP2 = 1.25 V No Load TA = 25°C 5 I CC(stby) – Standby Supply Current – mA I CC(stby) – Standby Supply Current – mA 6 4 3 2 5 10 15 20 4 3 2 1 – 50 1 0 5 VCC = 6 V CT = 1.5 V RT = Open COMP1, COMP2 = 1.25 V No Load 25 0 100 50 TA – Free-Air Temperature – °C VCC – Supply Voltage – V Figure 28 Figure 29 REFERENCE VOLTAGE vs SUPPLY VOLTAGE REFERENCE VOLTAGE vs SUPPLY VOLTAGE 1.5 1.27 Vref – Reference Voltage – V Vref – Reference Voltage – V TA = 25°C 1 0.5 1.26 1.25 1.24 IO = 1 mA TA = 25°C 0 0 5 10 15 20 VCC – Supply Voltage – V 25 1.23 0 5 10 15 20 25 VCC – Supply Voltage – V Figure 31 Figure 30 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 19 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 TYPICAL CHARACTERISTICS REFERENCE VOLTAGE vs FREE-AIR TEMPERATURE 1.27 Vref – Reference Voltage – V VCC = 6 V IO = – 1 mA 1.26 1.25 1.24 1.23 – 50 – 25 0 25 50 75 TA – Free-Air Temperature – °C Figure 32 20 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 100 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 MECHANICAL DATA D (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PIN SHOWN PINS ** 0.050 (1,27) 8 14 16 A MAX 0.197 (5,00) 0.344 (8,75) 0.394 (10,00) A MIN 0.189 (4,80) 0.337 (8,55) 0.386 (9,80) DIM 0.020 (0,51) 0.014 (0,35) 14 0.010 (0,25) M 8 0.244 (6,20) 0.228 (5,80) 0.008 (0,20) NOM 0.157 (4,00) 0.150 (3,81) 1 Gage Plane 7 A 0.010 (0,25) 0°–ā8° 0.044 (1,12) 0.016 (0,40) Seating Plane 0.069 (1,75) MAX 0.010 (0,25) 0.004 (0,10) 0.004 (0,10) 4040047 / B 10/94 NOTES: A. B. C. D. E. All linear dimensions are in inches (millimeters). This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0.006 (0,15). Four center pins are connected to die mount pad Falls within JEDEC MS-012 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 21 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 MECHANICAL DATA DB (R-PDSO-G**) PLASTIC SMALL-OUTLINE 28 PINS SHOWN 0,38 0,22 0,65 28 0,15 M 15 0,25 0,09 8,20 7,40 5,60 5,00 Gage Plane 1 14 0,25 A 0°–ā8° 0,95 0,55 Seating Plane 2,00 MAX 0,10 0,05 MIN PINS ** 14 16 20 24 28 30 38 A MAX 6,50 6,50 7,50 8,50 10,50 10,50 12,90 A MIN 5,90 5,90 6,90 7,90 9,90 9,90 12,30 DIM 4040065 /E 12/01 NOTES: A. B. C. D. 22 All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0,15. Falls within JEDEC MO-150 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 MECHANICAL DATA N (R-PDIP-T**) PLASTIC DUAL-IN-LINE PACKAGE 16 PIN SHOWN A 16 PINS ** 9 0.260 (6,60) 0.240 (6,10) 1 14 16 18 20 A MAX 0.775 (19,69) 0.775 (19,69) 0.920 (23.37) 0.975 (24,77) A MIN 0.745 (18,92) 0.745 (18,92) 0.850 (21.59) 0.940 (23,88) DIM 8 0.070 (1,78) MAX 0.035 (0,89) MAX 0.310 (7,87) 0.290 (7,37) 0.020 (0,51) MIN 0.200 (5,08) MAX Seating Plane 0.125 (3,18) MIN 0.100 (2,54) 0.021 (0,53) 0.015 (0,38) 0°–ā15° 0.010 (0,25) M 0.010 (0,25) NOM 14 Pin Only 4040049 / C 7/95 NOTES: A. All linear dimensions are in inches (millimeters). B. This drawing is subject to change without notice. C. Falls within JEDEC MS-001 (20-pin package is shorter than MS-001) POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 23 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 MECHANICAL DATA NS (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PINS SHOWN 0,51 0,35 1,27 14 0,25 M 8 0,15 NOM 8,20 7,40 5,60 5,00 Gage Plane 1 7 0,25 0°–ā10° A 1,05 0,55 Seating Plane 2,00 MAX 0,10 0,05 MIN PINS ** 14 16 20 24 A MAX 10,50 10,50 12,90 15,30 A MIN 9,90 9,90 12,30 14,70 DIM 4040062 / B 02/95 NOTES: A. All linear dimensions are in millimeters. B. This drawing is subject to change without notice. C. Body dimensions do not include mold flash or protrusion, not to exceed 0,15. 24 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TL1454A, TL1454AY DUAL-CHANNEL PULSE-WIDTH-MODULATION (PWM) CONTROL CIRCUIT SLVS423 A– MAY 2002 – REVISED SEPTEMBER 2002 MECHANICAL DATA PW (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PIN SHOWN 0,32 0,17 0,65 14 0,13 M 8 0,15 NOM 4,70 4,30 6,70 6,10 Gage Plane 0,25 1 7 0°–ā8° 0,70 0,40 A Seating Plane 1,20 MAX 0,10 0,10 MIN PINS ** 8 14 16 20 24 28 A MAX 3,30 5,30 5,30 6,80 8,10 10,00 A MIN 2,90 4,90 4,90 6,40 7,70 9,60 DIM 4040064 / B 10/94 NOTES: A. All linear dimensions are in millimeters. B. This drawing is subject to change without notice. C. Body dimensions do not include mold flash or protrusion not to exceed 0,15. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 25 PACKAGE OPTION ADDENDUM www.ti.com 22-Feb-2005 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty TL1454ACD ACTIVE SOIC D 16 40 Pb-Free (RoHS) CU NIPDAU Level-2-260C-1YEAR/ Level-1-220C-UNLIM TL1454ACDB ACTIVE SSOP DB 16 80 Pb-Free (RoHS) CU NIPDAU Level-2-260C-1YEAR/ Level-1-220C-UNLIM TL1454ACDBR ACTIVE SSOP DB 16 2000 Pb-Free (RoHS) CU NIPDAU Level-2-260C-1YEAR/ Level-1-220C-UNLIM TL1454ACDR ACTIVE SOIC D 16 2500 Pb-Free (RoHS) CU NIPDAU Level-2-260C-1YEAR/ Level-1-220C-UNLIM TL1454ACN ACTIVE PDIP N 16 25 Pb-Free (RoHS) CU NIPDAU Level-NC-NC-NC TL1454ACNSR ACTIVE SO NS 16 2000 Pb-Free (RoHS) CU NIPDAU Level-2-260C-1YEAR/ Level-1-220C-UNLIM TL1454ACPW ACTIVE TSSOP PW 16 90 None CU NIPDAU Level-1-220C-UNLIM TL1454ACPWR ACTIVE TSSOP PW 16 2000 None CU NIPDAU Level-1-220C-UNLIM Lead/Ball Finish MSL Peak Temp (3) (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - May not be currently available - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. None: Not yet available Lead (Pb-Free). Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Green (RoHS & no Sb/Br): TI defines "Green" to mean "Pb-Free" and in addition, uses package materials that do not contain halogens, including bromine (Br) or antimony (Sb) above 0.1% of total product weight. (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDECindustry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security Telephony www.ti.com/telephony Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2005, Texas Instruments Incorporated