TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 • • • • • • • • CLK/I I I I I I I I I I I GND Choice of Operating Speeds: TIBPAL22VP10-20C . . . 20 ns Max TIBPAL22VP10-25M . . . 25 ns Max Variable Product Term Distribution Allows More Complex Functions to Be Implemented Each Output Is User Programmable for Registered or Combinational Operation, Polarity, and Output Enable Control 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 VCC I/O/Q I/O/Q I/O/Q I/O/Q I/O/Q I/O/Q I/O/Q I/O/Q I/O/Q I/O/Q I TTL-Level Preload for Improved Testability Extra Terms Provide Logical Synchronous Set and Asynchronous Reset Capability C SUFFIX . . . FN PACKAGE M SUFFIX . . . FK PACKAGE (TOP VIEW) Fast Programming, High Programming Yield, and Unsurpassed Reliability Ensured Using Ti-W Fuses AC and DC Testing Done at the Factory Utilizing Special Designed-In Test Features Dependable Texas Instruments Quality and Reliability Package Options Include Plastic Dual-In-Line and Chip Carrier Packages description The TIBPAL22VP10’ is equivalent to the TIBPAL22V10A but offers additional flexibility in the output structure. The improved output macrocell uses the registered outputs as inputs when in a high-impedance condition. This provides two additional output configurations for a total of six possible macrocell configurations all of which are shown in Figure 1. I I CLK/I NC VCC I/O/Q I/O/Q • C SUFFIX . . . NT PACKAGE M SUFFIX . . . JT PACKAGE (TOP VIEW) Functionally Equivalent to the TIBPAL22V10/10A, with Additional Feedback Paths in the Output Logic Macrocell I I I NC I I I 4 5 3 2 1 28 27 26 25 6 24 7 23 8 22 9 21 10 20 11 19 12 13 14 15 16 17 18 I/O/Q I/O/Q I/O/Q NC I/O/Q I/O/Q I/O/Q I I GND NC I I/O/Q I/O/Q • NC – No internal connection Pin assignments in operating mode These devices contain up to 22 inputs and 10 outputs. They incorporate the unique capability of defining and programming the architecture of each output on an individual basis. Outputs may be registered or nonregistered and inverting or noninverting. In addition, the data may be fed back into the array from either the register or the I/O port. The ten potential outputs are enabled through the use of individual product terms. Further advantages can be seen in the introduction of variable product term distribution. This technique allocates from 8 to 16 logical product terms to each output for an average of 12 product terms per output. This variable allocation of terms allows far more complex functions to be implemented than in previously available devices. These devices are covered by U.S. Patent 4,410,987. IMPACT-X is a trademark of Texas Instruments Incorporated. Copyright 1991, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 description (continued) Circuit design is enhanced by the addition of a synchronous set and an asynchronous reset product term. These functions are common to all registers. When the synchronous set product term is a logic 1, the output registers are loaded with a logic 1 on the next low-to-high clock transition. When the asynchronous reset product term is a logic 1, the output registers are loaded with a logic 0. The output logic level after set or reset depends on the polarity selected during programming. Output registers can be preloaded to any desired state during testing. Preloading permits full logical verification during product testing. With features such as programmable output logic macrocells and variable product term distribution, the TIBPAL22VP10’ offers quick design and development of custom LSI functions with complexities of 500 to 800 equivalent gates. Since each of the ten output pins may be individually configured as inputs on either a temporary or permanent basis, functions requiring up to 21 inputs and a single output or down to 12 inputs and 10 outputs are possible. A power-up clear function is supplied that forces all registered outputs to a predetermined state after power is applied to the device. Registered outputs selected as active-low power-up with their outputs high. Registered outputs selected as active-high power-up with their outputs low. A single security fuse is provided on each device to discourage unauthorized copying of fuse patterns. Once blown, the verification circuitry is disabled and all other fuses will appear to be open. The TIBPAL22V10-20C is characterized for operation from 0°C to 75°C. The TIBPAL22V10-25M is characterized for operation over the full military temperature range of –55°C to 125°C. 2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 functional block diagram (positive logic) C1 Set & 1S Reset 44 x 132 8 R 1 Output Logic Macrocell I/O/Q EN 10 I/O/Q 22 CLK/I EN 12 I/O/Q EN 14 I/O/Q EN 16 I/O/Q EN 16 I/O/Q I 11 22 10 EN 14 I/O/Q EN 12 I/O/Q EN 10 I/O/Q EN 8 I/O/Q EN 10 10 10 denotes fused inputs POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 I I I I 5 4 3 2 1 First Fuse Numbers CLK/I 2860 2156 2112 1496 1452 924 880 440 396 0 0 4 8 logic symbol (positive logic) 12 16 20 24 Increments 28 32 36 40 P = 5816 R = 5817 Macrocell P = 5814 R = 5815 Macrocell P = 5812 R = 5813 Macrocell P = 5810 R = 5811 Macrocell P = 5808 R = 5809 Macrocell 19 20 21 22 23 I/O/Q I/O/Q I/O/Q I/O/Q I/O/Q Asynchronous Reset (to all registers) TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 11 10 9 8 7 5764 5720 5368 5324 4884 4840 4312 4268 3652 3608 Fuse number = First fuse number + Increment Inside each MACROCELL the ”P” fuse is the polarity fuse and the ”R” fuse is the register fuse. I I I I I I 6 2904 P = 5826 R = 5827 Macrocell P = 5824 R = 5825 Macrocell P = 5822 R = 5823 Macrocell P = 5820 R = 5821 Macrocell P = 5818 R = 5819 Macrocell 13 14 15 16 17 18 I Synchronous Set (to all registers) I/O/Q I/O/Q I/O/Q I/O/Q I/O/Q TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 5 TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 output logic macrocell diagram Output Logic Macrocell MUX 2 AR 3 I=0 R 1D 0 C1 SS 1 1S 0 1 0 From Clock Buffer G 3 S0 MUX 1/2/3 0 1 0 G 3 S2† S1 AR = asynchronous reset SS = synchronous set † This fuse is unique to the Texas Instruments TIBPAL22VP10’. It allows feedback from the I/O port using registered outputs as shown in the macrocell fusing logic function table. 6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 R R 1D 1D C1 1S C1 1S S2 = 0 S1 = 0 S0 = 0 REGISTER FEEDBACK, REGISTERED, ACTIVE-LOW OUTPUT S2 = 0 S1 = 0 S0 = 1 REGISTER FEEDBACK, REGISTERED, ACTIVE-HIGH OUTPUT R R 1D 1D C1 C1 S2 = 1 S1 = 0 S0 = 0 1S I/O FEEDBACK, REGISTERED, ACTIVE-LOW OUTPUT† 1S I/O FEEDBACK, REGISTERED, ACTIVE-HIGH OUTPUT† S2 = X S1 = 1 S0 = 0 I/O FEEDBACK, COMBINATIONAL, ACTIVE-LOW OUTPUT S2 = 1 S1 = 0 S0 = 1 S2 = X S1 = 1 S0 = 1 I/O FEEDBACK, COMBINATIONAL, ACTIVE-HIGH OUTPUT † These configurations are unique to the TIBPAL22VP10’ and provide added flexibility when comparing it to the TIBPAL22V10 or TIBPAL22V10A. Figure 1. Resultant Macrocell Feedback and Output Logic After Programming POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7 TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 MACROCELL FEEDBACK AND OUTPUT FUNCTION TABLE S2 FUSE SELECT S1 S0 FEEDBACK AND OUTPUT CONFIGURATION 0 0 0 Register feedback Registered Active low 0 0 1 Register feedback Registered Active high 1 0 0 I/O feedback Registered Active low 1 0 1 I/O feedback Registered Active high X 1 0 I/O feedback Combinational Active low X 1 1 I/O feedback Combinational Active high 0 = unblown fuse, 1 = blown fuse, X = unblown or blown fuse S2, S1 and S0 are select-function fuses as shown in the output logic macrocell diagram. absolute maximum ratings over operating free-air temperature range (unless otherwise noted) Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V Voltage applied to disabled output (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V Operating free-air temperature range: TIBPAL22VP10-20C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 75°C TIBPAL22VP10-25M . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C NOTE 1: These ratings apply except for programming pins during a programming cycle or during a preload cycle. recommended operating conditions TIBPAL22VP10-20C VCC VIH Supply voltage VIL IOH Low-level input voltage IOL fclock tw †f f 8 High-level input voltage TIBPAL22VP10-25M NOM MAX MIN NOM MAX 4.75 5 5.25 4.5 5 5.5 V 5.5 2 5.5 V 2 0.8 0.8 V High-level output current – 3.2 –2 mA Low-level output current Clock frequency† 16 12 mA 25 MHz 37 Pulse duration Clock high or low 10 20 Asynchronous Reset high or low 20 30 Input 15 20 Feedback 15 20 Synchronous Preset (active) 15 20 Asynchronous Reset (inactive) tsu Setup time before clock↑ 20 25 th TA Hold time, input, preset, or feedback after clock↑ 0 0 Operating free-air temperature 0 clock clock UNIT MIN (with feedback) + (without feedback) t su + ) t pd 1 ,f without feedback can be calculated as (CLK to Q) clock ) 1 t w high . t w low POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 75 – 55 ns ns ns 125 °C TIBPAL22VP10-20C HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 electrical characteristics over recommended operating free-air temperature range PARAMETER TEST CONDITIONS VIK VOH VCC = 4.75 V, VCC = 4.75 V, II = – 18 mA IOH = – 3.2 mA VOL IOZH VCC = 4.75 V, VCC = 5.25 V, IOL = 16 mA VO = 2.7 V VCC = 5.25 V, VO = 0.4 V II IIH VCC = 5.25 V, VCC = 5.25 V, VI = 5.5 V VI = 2.7 V IIL IOS‡ VCC = 5.25 V, VCC = 5.25 V, VI = 0.4 V VO = 0.5 V ICC VCC = 5.25 V, VI = GND, Any output IOZL Any I/O MIN 2.4 TYP† MAX UNIT – 1.2 V 3.5 0.35 V 0.5 V 0.1 mA – 100 – 250 1 – 30 Outputs open 140 µA mA 25 µA – 0.25 mA – 90 mA 180 mA switching characteristics over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) FROM (INPUT) TO (OUTPUT) I, I/O I/O CL = 50 pF, 12 20 ns tpd tpd I, I/O (reset) Q R1 = 300 Ω, 12 20 ns CLK Q R2 = 390 Ω, 8 12 ns ten tdis I, I/O I/O, Q See Figure 4 12 20 ns I, I/O I/O, Q 12 20 ns PARAMETER fmax§ tpd TEST CONDITION MIN TYP† 37 50 MAX UNIT MHz † All typical values are at VCC = 5 V, TA = 25°C. ‡ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. VO is set at 0.5 V to avoid test problems caused by test equipment ground degradation. 1 § f max (with feedback) ,f without feedback can be calculated as t su t (CLK to Q) max pd + f max (without feedback) + ) ) 1 t w high . t w low POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 9 TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 electrical characteristics over recommended operating free-air temperature range PARAMETER TEST CONDITIONS VIK VOH VCC = 4.5 V, VCC = 4.5 V, II = – 18 mA IOH = –2 mA VOL IOZH VCC = 4.5 V, VCC = 5.5 V, IOL = 12 mA VO = 2.7 V IOZL II VCC = 5.5 V, VCC = 5.5 V, VO = 0.4 V VI = 5.5 V IIH IIL VCC = 5.5 V, VCC = 5.5 V, VI = 2.7 V VI = 0.4 V IOS‡ ICC VCC = 5.5 V, VCC = 5.5 V, VO = 0.5 V VI = GND, MIN 2.4 TYP† UNIT – 1.2 V 3.5 0.25 – 30 Outputs open MAX 140 V 0.5 V 0.1 mA – 0.1 mA 1 mA 25 µA – 0.25 mA – 90 mA 200 mA switching characteristics over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) FROM (INPUT) TO (OUTPUT) I, I/O I/O CL = 50 pF, 12 25 ns tpd tpd I, I/O (reset) Q R1 = 390 Ω, 12 25 ns CLK Q R2 = 750 Ω, 8 15 ns ten tdis I, I/O I/O, Q See Figure 4 12 25 ns I, I/O I/O, Q 12 25 ns PARAMETER fmax§ tpd TEST CONDITION MIN TYP† 25 50 MAX UNIT MHz † All typical values are at VCC = 5 V, TA = 25°C. ‡ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. VO is set at 0.5 V to avoid test problems caused by test equipment ground degradation. 1 § f max (with feedback) ,f without feedback can be calculated as t su t (CLK to Q) max pd + f max (without feedback) 10 + ) ) 1 t w high . t w low POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 preload procedure for registered outputs (see Notes 2 and 3) The output registers can be preloaded to any desired state during device testing. This permits any state to be tested without having to step through the entire state-machine sequence. Each register is preloaded individually by following the steps given below: Step 1. Step 2. Step 3. Step 4. With VCC at 5 V and pin 1 at VIL, raise pin 13 to VIHH. Apply either VIL or VIH to the output corresponding to the register to be preloaded. Pulse pin 1, clocking in preload data. Remove output voltage, then lower pin 13 to VIL. Preload can be verified by observing the voltage level at the output pin. VIHH Pin 13 tsu VIL td td tw VIH Pin 1 VIL VIH Registered I/O Input VOH Output VIL VOL Figure 2. Preload Waveforms NOTES: 2. Pin numbers shown are for JT and NT packages only. If chip-carrier socket adapter is not used, pin numbers must be changed accordingly. 3. td = tsu = tw = 100 ns to 1000 ns. VIHH = 10.25 V to 10.75 V. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 11 TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 power-up reset Following power up, all registers are reset to zero. The output level depends on the polarity selected during programming. This feature provides extra flexibility to the system designer and is especially valuable in simplifying state-machine initialization. To ensure a valid power-up reset, it is important that the rise of VCC be monotonic. Following power-up reset, a low-to-high clock transition must not occur until all applicable input and feedback setup times are met. VCC 5V 4V tpd † (600 ns typ, 1000 ns MAX) VOH Active High Registered Output State Unknown 1.5 V VOL VOH Active Low Registered Output State Unknown 1.5 V VOL tsu ‡ VIH CLK 1.5 V 1.5 V VIL tw † This is the power-up reset time and applies to registered outputs only. The values shown are from characterization data. ‡ This is the setup time for input or feedback. Figure 3. Power-Up Reset Waveforms programming information Texas Instruments programmable logic devices can be programmed using widely available software and inexpensive device programmers. When the additional fuses are not being used, the TIBPAL22VP10 can be programmed using the TIBPAL22V10/10A programming algorithm. The fuse configuration data can either be from a JEDEC file (format per JEDEC Standard No. 3-A) or a TIBPAL22V10/10A master. Complete programming specifications, algorithms, and the latest information on hardware, software, and firmware are available upon request. Information on programmers capable of programming Texas Instruments programmable logic is also available, upon request, from the nearest TI field sales office, local authorized TI distributor, or by calling Texas Instruments at (214) 997-5666. 12 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TIBPAL22VP10-20C, TIBPAL22VP10-25M HIGH-PERFORMANCE IMPACT-X PROGRAMMABLE ARRAY LOGIC CIRCUITS SRPS013 – D2943, FEBRUARY 1987 – REVISED JUNE 1991 PARAMETER MEASUREMENT INFORMATION 5V S1 R1 From Output Under Test Test Point CL (see Note A) R2 LOAD CIRCUIT FOR 3-STATE OUTPUTS 1.5 V 1.5 V tw th (3.5 V) [3 V] Data Input 1.5 V VOLTAGE WAVEFORMS SETUP AND HOLD TIMES (0.3 V) [0] In-Phase Output VOH 1.5 V VOL tpd tpd 1.5 V VOH 1.5 V VOL (3.5 V) [3 V] 1.5 V Waveform 1 S1 Closed (see Note B) tdis 1.5 V ≈ 3.3 V VOL +0.5 V VOL tdis ten Waveform 2 S1 Open (see Note B) VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES 1.5 V (0.3 V) [0] ten tpd 1.5 V 1.5 V (0.3 V) [0] Output Control (low–level enabling) 1.5 V tpd 1.5 V VOLTAGE WAVEFORMS PULSE DURATIONS (3.5 V) [3 V] 1.5 V (3.5 V) [3 V] Low-Level Pulse 1.5 V (0.3 V) [0] Input 1.5 V (0.3 V) [0] (0.3 V) [0] tsu Out-of-Phase Output (see Note D) (3.5 V) [3 V] High-Level Pulse (3.5 V) [3 V] Timing Input VOH 1.5 V VOH –0.5 V ≈0V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS NOTES: A. CL includes probe and jig capacitance and is 50 pF for tpd and ten, 5 pF for tdis. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses have the following characteristics: For C suffix, use the voltage levels indicated in parentheses ( ). PRR ≤ 1 MHz, tr = tf ≤ 2 ns, duty cycle = 50%. For M suffix, use the voltage levels indicated in brackets [ ]. PRR ≤ 10 MHz, tr and tf ≤ 2 ns, duty cycle = 50%. D. When measuring propagation delay times of 3-state outputs, switch S1 is closed. E. Equivalent loads may be used for testing. Figure 4. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 13 TI Worldwide Sales Offices ALABAMA: Huntsville: 4960 Corporate Drive, Suite 150, Huntsville, AL 35805, (205) 837-7530. ARIZONA: Phoenix: 8825 N. 23rd Avenue, Suite 100, Phoenix, AZ 85021, (602) 995-1007. CALIFORNIA: Irvine: 1920 Main Street, Suite 900, Irvine, CA 92714, (714) 660-1200; San Diego: 5625 Ruffin Road, Suite 100, San Diego, CA 92123, (619) 278-9600; Santa Clara: 5353 Betsy Ross Drive, Santa Clara, CA 95054, (408) 980-9000; Woodland Hills: 21550 Oxnard Street, Suite 700, Woodland Hills, CA 91367, (818) 704-8100. COLORADO: Aurora: 1400 S. Potomac Street, Suite 101, Aurora, CO 80012, (303) 368-8000. CONNECTICUT: Wallingford: 9 Barnes Industrial Park So., Wallingford, CT 06492, (203) 269-0074. FLORIDA: Altamonte Springs: 370 S. North Lake Boulevard, Suite 1008, Altamonte Springs, FL 32701, (407) 260-2116; Fort Lauderdale: 2950 N.W. 62nd Street, Suite 100, Fort Lauderdale, FL 33309, (305) 973-8502; Tampa: 4803 George Road, Suite 390, Tampa, FL 33634-6234, (813) 885-7588. GEORGIA: Norcross: 5515 Spalding Drive, Norcross, GA 30092-2560, (404) 662-7967. ILLINOIS: Arlington Heights: 515 West Algonquin, Arlington Heights, IL 60005, (708) 640-6925. INDIANA: Carmel: 550 Congressional Drive, Suite 100, Carmel, IN 46032, (317) 573-6400; Fort Wayne: 103 Airport North Office Park, Fort Wayne, IN 46825, (219) 489-4697. KANSAS: Overland Park: 7300 College Boulevard, Lighton Plaza, Suite 150, Overland Park, KS 66210, (913) 451-4511. MARYLAND: Columbia: 8815 Centre Park Drive, Suite 100, Columbia, MD 21045, (410) 964-2003. MASSACHUSETTS: Waltham: Bay Colony Corporate Center 950 Winter Street, Suite 2800, Waltham, MA 02154, (617) 895-9100. MICHIGAN: Farmington Hills: 33737 W. 12 Mile Road, Farmington Hills, MI 48018, (313) 553-1581. MINNESOTA: Eden Prairie: 11000 W. 78th Street, Suite 100, Eden Prairie, MN 55344, (612) 828-9300. MISSOURI: St. Louis: 12412 Powerscourt Drive, Suite 125, St. Louis, MO 63131, (314) 821-8400. NEW JERSEY: Iselin: Metropolitan Corporate Plaza, 485 Bldg E. U.S. 1 South, Iselin, NJ 08830, (908) 750-1050. NEW MEXICO: Albuquerque: 2709 J. Pan American Freeway, N.E., Albuquerque, NM 87101, (505) 345-2555. NEW YORK: East Syracuse: 6365 Collamer Drive, East Syracuse, NY 13057, (315) 463-9291; Fishkill: 300 Westage Business Center, Suite 140, Fishkill, NY 12524, (914) 897-2900; Melville: 48 South Service Road, Suite 100, Melville, NY 11747, (516) 454-6601; Pittsford: 2851 Clover Street, Pittsford, NY 14534, (716) 385-6770. NORTH CAROLINA: Charlotte: 8 Woodlawn Green, Suite 100, Charlotte, NC 28217, (704) 527-0930; Raleigh: 2809 Highwoods Boulevard, Suite 100, Raleigh, NC 27625, (919) 876-2725. OHIO: Beachwood: 23775 Commerce Park Road, Beachwood, OH 44122-5875, (216) 765-7258; Beavercreek: 4200 Colonel Glenn Highway, Suite 600, Beavercreek, OH 45431, (513) 427-6200. OREGON: Beaverton: 6700 S.W. 105th Street, Suite 110, Beaverton, OR 97005, (503) 643-6758. PENNSYLVANIA: Blue Bell: 670 Sentry Parkway, Suite 200, Blue Bell, PA 19422, (215) 825-9500. PUERTO RICO: Hato Rey: 615 Mercantile Plaza Building, Suite 505, Hato Rey, PR 00919, (809) 753-8700. TEXAS: Austin: 12501 Research Boulevard, Austin, TX 78759, (512) 250-6769; Dallas: 7839 Churchill Way, Dallas, TX 75251, (214) 917-1264; Houston: 9301 Southwest Freeway, Commerce Park, Suite 360, Houston, TX 77074, (713) 778-6592; Midland: FM 1788 & I-20, Midland, TX 79711-0448, (915) 561-7137. UTAH: Salt Lake City: 2180 South 1300 East, Sute 335, Salt Lake City, UT 54106, (801) 466-8972. WISCONSIN: Waukesha: 20825 Swenson Drive, Suite 900, Waukesha WI 53186, (414) 798-1001. CANADA: Nepean: 301 Moodie Drive, Suite 102, Mallom Center, Nepean, Ontario, Canada K2H 9C4, (613) 726-1970; Richmond Hill: 280 Centre Street East, Richmond Hill, Ontario, Canada L4C 1B1, (416) 884-9181; St. Laurent: 9460 Trans Canada Highway, St. Laurent, Quebec, Canada H4S 1R7, (514) 335-8392. AUSTRALIA (& NEW ZEALAND): Texas Instruments Australia Ltd., 6-10 Talavera Road, North Ryde (Sydney), New South Wales, Australia 2113, 2-878-9000; 14th Floor, 380 Street, Kilda Road, Melbourne, Victoria, Australia 3004, 3-696-1211; 171 Philip Highway, Elizabeth, South Australia 5112, 8 255-2066. BELGIUM: Texas Instruments Belgium S.A./N.V., Avenue Jules Bordetlaan 11, 1140 Brussels, Belgium, (02) 242 30 80. BRAZIL: Texas Instruments Electronicos do Brasil Ltda., Av. Eng. Luiz Carlos Berrini 1461-11o andar, 04571, Sao Paulo, SP, Brazil, 11-535–5133. DENMARK: Texas Instruments A/S, Borupvang 2D, 2750 Ballerup, Denmark, (44) 68 74 00. FINLAND: Texas Instruments OY, Ahertajantle 3, P.O. Box 86, 02321 Espoo, Finland, (0) 802 6517. FRANCE: Texas Instruments France, 8-10 Avenue Morane-Saulnier, B.P. 67, 78141 Velizy Villacoublay Cedex, France, (1) 30 70 1003. GERMANY: Texas Instruments Deutschland GmbH., Haggertystrasse 1, 8050 Freising, (08161) 80-0; Kurfurstendamm 195-196, 1000 Berlin 15, (030) 8 82 73 65; Dusseldorfer Strasse 40, 6236 Eschborn 1, (06196) 80 70; Kirchhorster Strasse 2, 3000 Hannover 51, (0511) 64 68-0; Maybachstrasse II, 7302 Ostfildern 2 (Nellingen), (0711) 3403257; Gildehofcenter, Hollestrasses 3, 4300 Essen 1, (0201) 24 25-0. HOLLAND: Texas Instruments Holland B.V., Hogehilweg 19, Postbus 12995, 1100 AZ Amsterdam-Zuidoost, Holland, (020) 5602911. HONG KONG: Texas Instruments Hong Kong Ltd., 8th Floor, World Shipping Center, 7 Canton Road, Kowloon, Hong Kong, 737-0338. HUNGARY: Texas Instruments Representation, Budaorsi ut.42, 1112 Budapest, Hungary, (1) 1 66 66 17. IRELAND: Texas Instruments Ireland Ltd., 7/8 Harcourt Street, Dublin 2, Ireland, (01) 755233. ITALY: Texas Instruments Italia S.p.A., Centro Direzionale Colleoni, Palazzo Perseo-Via Paracelso 12, 20041 Agrate Brianza (Mi), Italy, (039) 63221; Via Castello della Magliana, 38, 00148 Roma, Italy (06) 6572651; Via Amendola, 17, 40100 Bologna, Italy (051) 554004. JAPAN: Texas Instruments Japan Ltd., Aoyama Fuji Building 3-6-12 Kita-Aoyama Minato-ku, Tokyo, Japan 107, 03-498-2111; MS Shibaura Building 9F, 4-13-23 Shibaura, Minato-ku, Tokyo, Japan 108, 03-769-8700; Nissho-iwai Building 5F, 2-5-8 Imabashi, Chuou-ku, Osaka, Japan 541, 06-204-1881; Dai-ni Toyota Building Nishi-kan 7F, 4-10-27 Meieki, Nakamura-ku, Nagoya, Japan 450, 052-583-8691; Kanazawa Oyama-cho Daiichi Seimei Building 6F, 3-10 Oyama-cho, Kanazawa, Ishikawa, Japan 920, 0762-23-5471; Matsumoto Showa Building 6F, 1-2-11 Fukashi, Matsumoto, Nagano, Japan 390, 0263-33-1060; Daiichi Olympic Tachikawa Building 6F, 1-25-12, Akebono-cho, Tachikawa, Tokyo, Japan 190, 0425-27-6760; Yokohama Business Park East Tower 10F, 134 Goudo-cho Hodogaya-ku, Yokohama-shi, Kanagawa, Japan 240, 045-338-1220; Nihon Seimei Kyoto Yasaka Building 5F, 843-2, Higashi Shiokohji-cho, Higashi-iru, Nishinotoh-in, Shiokohji-dori, Shimogyo-ku, Kyoto, Japan 600, 075-341-7713; Sumitomo Seimei Kumagaya Building 8F, 2-44 Yayoi, Kumagaya, Saitama, Japan 360, 0485-22-2440; 2597-1, Aza Harudai, Oaza Yasaka, Kitsuki, Oita, Japan 873, 09786-3-3211. KOREA: Texas Instruments Korea Ltd., 28th Floor, Trade Tower, 159, Samsung-Dong, Kangnam-ku Seoul, Korea, 2 551-2800. MALAYSIA: Texas Instruments Malaysia, Sdn. Bhd., Asia Pacific, Lot 36.1 #Box 93, Menara Maybank, 100 Jalan Tun Perak, 50050 Kuala Llumpur, Malaysia, 2306001. MEXICO: Texas Instruments de Mexico S.A., de C.V., Alfonso Reyes 115, Col. Hipodromo Condesa, Mexico, D.F., Mexico 06170, 5-515-6081. NORWAY: Texas Instruments Norge A/S, P.B. 106, Refstad (Sinsenveien 53), 0513 Oslo 5, Norway, (02) 155 090. PEOPLE’S REPUBLIC OF CHINA: Texas Instruments China Inc., Beijing Representative Office, 7-05 CITIC Building, 19 Jianguomenwai Dajie, Beijing, China, 500-2255, Ext. 3750. PHILIPPINES: Texas Instruments Asia Ltd., Philippines Branch, 14th Floor, Ba-Lepanto Building, Paseo de Roxas, Makati, Metro Manila, Philippines, 2-8176031. PORTUGAL: Texas Instruments Equipamento Electronico (Portugal) Ltda., Ing. Frederico Ulricho, 2650 Moreira Da Maia, 4470 Maia, Portugal (2) 948 1003. SINGAPORE (& INDIA, INDONESIA, MALAYSIA, THAILAND): Texas Instruments Singapore (PTE) Ltd., Asia Pacific, 101 Thomson Road, #23-01, United Square, Singapore 1130, 3508100. SPAIN: Texas Instruments Espana S.A., c/Gobelas 43, Urbanizasion, La Florida, 28023, Madrid, Spain, (1) 372 8051; c/Diputacion, 279-3-5, 08007 Barcelona, Spain, (3) 317 91 80. SWEDEN: Texas Instruments International Trade Corporation (Sverigefilialen), Isafjordsgaton, Box 30, S-164 93 Kista, Sweden, (08) 752 58 00. SWITZERLAND: Texas Instruments Switzerland AG, Riedstrasse 6, C8953 Dietikon, Switzerland, (01) 744 2811. TAIWAN: Texas Instruments Taiwan Limited, Taipei Branch, 10th Floor Bank Tower, 205 Tung Hwa N. Road, Taipei, Taiwan, 10592 Republic of China, 2-7139311. TURKEY: Texas Instruments, DSEG MidEast Regional Marketing Office, Karum Center, Suite 442, Iran Caddesi 21, 06680 Kavaklldere, Ankara, Turkey, 4-468-0155. UNITED KINGDOM: Texas Instruments Ltd., Manton Lane, Bedford, England, MK41 7PA, (0234) 270 111. TI Authorized North American Distributors Alliance Electronics, Inc. (military product only) Almac/Arrow Anthem Electronics Arrow/Schweber Future Electronics (Canada) GRS Electronics Co., Inc. * Hall-Mark Electronics Marshall Industries Newark Electronics * Wyle Laboratories Zeus Components Rochester Electronics, Inc. (obsolete product only) *Not authorized for TI military products B0892 1992 Texas Instruments Incorporated TI Authorized TI North American Sales North American Offices Distributors ALABAMA: Huntsville: (205) 837-7530 ARIZONA: Phoenix: (602) 995-1007 CALIFORNIA: Irvine: (714) 660-1200 San Diego: (619) 278-9600 Santa Clara: (408) 980-9000 Woodland Hills: (818) 704-8100 COLORADO: Aurora: (303) 368-8000 CONNECTICUT: Wallingford: (203) 269-0074 FLORIDA: Altamonte Springs: (407) 260-2116 Fort Lauderdale: (305) 973-8502 Tampa: (813) 885-7588 GEORGIA: Norcross: (404) 662-7967 ILLINOIS: Arlington Heights: (708) 640-3000 INDIANA: Carmel: (317) 573-6400 Fort Wayne: (219) 489-4697 KANSAS: Overland Park: (913) 451-4511 MARYLAND: Columbia: (410) 964-2003 MASSACHUSETTS: Waltham: (617) 895-9100 MICHIGAN: Farmington Hills: (313) 553-1581 MINNESOTA: Eden Prairie: (612) 828-9300 MISSOURI: St. Louis: (314) 821-8400 NEW JERSEY: Iselin: (908) 750-1050 NEW MEXICO: Albuquerque: (505) 345-2555 NEW YORK: East Syracuse: (315) 463-9291 Fishkill: (914) 897-2900 Melville: (516) 454-6600 Pittsford: (716) 385-6770 NORTH CAROLINA: Charlotte: (704) 527-0930 Raleigh: (919) 876-2725 OHIO: Beachwood: (216) 765-7258 Beavercreek: (513) 427-6200 OREGON: Beaverton: (503) 643-6758 PENNSYLVANIA: Blue Bell: (215) 825-9500 PUERTO RICO: Hato Rey: (809) 753-8700 TEXAS: Austin: (512) 250-6769 Dallas: (214) 917-1264 Houston: (713) 778-6592 Midland: (915) 561-7137 UTAH: Salt Lake CIty: (801) 466-8972 WISCONSIN: Waukesha: (414) 798-1001 CANADA: Nepean: (613) 726-1970 Richmond Hill: (416) 884-9181 St. Laurent: (514) 335-8392 TI Regional Technology Centers CALIFORNIA: Irvine: (714) 660-8140 Santa Clara: (408) 748-2222 GEORGIA: Norcross: (404) 662-7945 ILLINOIS: Arlington Heights: (708) 640-2909 INDIANA: Indianapolis: (317) 573-6400 MASSACHUSETTS: Waltham: (617) 895-9196 MEXICO: Mexico City: 491-70834 MINNESOTA: Minneapolis: (612) 828-9300 TEXAS: Dallas: (214) 917-3881 CANADA: Nepean: (613) 726-1970 Alliance Electronics, Inc. (military product only) Almac/Arrow Anthem Electronics Arrow/Schweber Future Electronics (Canada) GRS Electronics Co., Inc. Hall-Mark Electronics Marshall Industries Newark Electronics Rochester Electronics, Inc. (obsolete product only (508) 462-9332) Wyle Laboratories Zeus Components TI Distributors ALABAMA: Arrow/Schweber (205) 837-6955; Hall-Mark (205) 837-8700; Marshall (205) 881-9235. ARIZONA: Anthem (602) 966-6600; Arrow/Schweber (602) 437-0750; Hall-Mark (602) 431-0030; Marshall (602) 496-0290; Wyle (602) 437-2088. CALIFORNIA: Los Angeles/Orange County: Anthem (818) 775-1333, (714) 768-4444; Arrow/Schweber (818) 380-9686, (714) 838-5422; Hall-Mark (818) 773-4500, (714) 727-6000; Marshall (818) 878-7000, (714) 458-5301; Wyle (818) 880-9000, (714) 863-9953; Zeus (714) 921-9000, (818) 889-3838; Sacramento: Anthem (916) 624-9744; Hall-Mark (916) 624-9781; Marshall (916) 635-9700; Wyle (916) 638-5282; San Diego: Anthem (619) 453-9005; Arrow/Schweber (619) 565-4800; Hall-Mark (619) 268-1201; Marshall (619) 578-9600; Wyle (619) 565-9171; Zeus (619) 277-9681. San Francisco Bay Area: Anthem (408) 453-1200; Arrow/Schweber (408) 441-9700, (510) 490-9477; Hall-Mark (408) 432-4000; Marshall (408) 942-4600; Wyle (408) 727-2500; Zeus (408) 629-4789. COLORADO: Anthem (303) 790-4500; Arrow/Schweber (303) 799-0258; Hall-Mark (303) 790-1662; Marshall (303) 451-8383; Wyle (303) 457-9953. CONNECTICUT: Anthem (203) 575-1575; Arrow/Schweber (203) 265-7741; Hall-Mark (203) 271-2844; Marshall (203) 265-3822. FLORIDA: Fort Lauderdale: Arrow/Schweber (305) 429-8200; Halll-Mark (305) 971-9280; Marshall (305) 977-4880. Orlando: Arrow/Schweber (407) 333-9300; Hall-Mark (407) 830-5855; Marshall (407) 767-8585; Zeus (407) 788-9100. Tampa: Hall-Mark (813) 541-7440; Marshall (813) 573-1399. GEORGIA: Arrow/Schweber (404) 497-1300; Hall-Mark (404) 623-4400; Marshall (404) 923-5750. ILLINOIS: Anthem (708) 884-0200; Arrow/Schweber (708) 250-0500; Hall-Mark (312) 860-3800; Marshall (708) 490-0155; Newark (312)784-5100. INDIANA: Arrow/Schweber (317) 299-2071; Hall-Mark (317) 872-8875; Marshall (317) 297-0483. IOWA: Arrow/Schweber (319) 395-7230. KANSAS: Arrow/Schweber (913) 541-9542; Hall-Mark (913) 888-4747; Marshall (913) 492-3121. MARYLAND: Anthem (301) 995-6640; Arrow/Schweber (301) 596-7800; Hall-Mark (301) 988-9800; Marshall (301) 622-1118; Zeus (301) 997-1118. MASSACHUSETTS: Anthem (508) 657-5170; Arrow/Schweber (508) 658-0900; Hall-Mark (508) 667-0902; Marshall (508) 658-0810; Wyle (617) 272-7300; Zeus (617) 246-8200. MICHIGAN: Detroit: Arrow/Schweber (313) 462-2290; Hall-Mark (313) 416-5800; Marshall (313) 525-5850; Newark (313) 967-0600. MINNESOTA: Anthem (612) 944-5454; Arrow/Schweber (612) 941-5280; Hall-Mark (612) 881-2600; Marshall (612) 559-2211. MISSOURI: Arrow/Schweber (314) 567-6888; Hall-Mark (314) 291-5350; Marshall (314) 291-4650. NEW JERSEY: Anthem (201) 227-7960; Arrow/Schweber (201) 227-7880, (609) 596-8000; Hall-Mark (201) 515-3000, (609) 235-1900; Marshall (201) 882-0320, (609) 234-9100. NEW MEXICO: Alliance (505) 292-3360. NEW YORK: Long Island: Anthem (516) 864-6600; Arrow/Schweber (516) 231-1000; Hall-Mark (516) 737-0600; Marshall (516) 273-2424; Zeus (914) 937-7400. Rochester: Arrow/Schweber (716) 427-0300; Hall-Mark (716) 425-3300; Marshall (716) 235-7620. Syracuse: Marshall (607) 785-2345. NORTH CAROLINA: Arrow/Schweber (919) 876-3132; Hall-Mark (919) 872-0712; Marshall (919) 878-9882. OHIO: Cleveland: Arrow/Schweber (216) 248-3990; Hall-Mark (216) 349-4632; Marshall (216) 248-1788. Columbus: Hall-Mark (614) 888-3313. Dayton: Arrow/Schweber (513) 435-5563; Marshall (513) 898-4480; Zeus (513) 293-6162. OKLAHOMA: Arrow/Schweber (918) 252-7537; Hall-Mark (918) 254-6110. OREGON: Almac/Arrow (503) 629-8090; Anthem (503) 643-1114; Marshall (503) 644-5050; Wyle (503) 643-7900. PENNSYLVANIA: Anthem (215) 443-5150; Arrow/Schweber (215) 928-1800; GRS (215) 922-7037; (609) 964-8560; Marshall (412) 788-0441. TEXAS: Austin: Arrow/Schweber (512) 835-4180; Hall-Mark (512) 258-8848; Marshall (512) 837-1991; Wyle (512) 345-8853; Dallas: Anthem (214) 238-7100; Arrow/Schweber (214) 380-6464; Hall-Mark (214) 553-4300; Marshall (214) 233-5200; Wyle (214) 235-9953; Zeus (214) 783-7010; Houston: Arrow/Schweber (713) 530-4700; Hall-Mark (713) 781-6100; Marshall (713) 467-1666; Wyle (713) 879-9953. UTAH: Anthem (801) 973-8555; Arrow/Schweber (801) 973-6913; Marshall (801) 973-2288; Wyle (801) 974-9953. WASHINGTON: Almac/Arrow (206) 643-9992, Anthem (206) 483-1700; Marshall (206) 486-5747; Wyle (206) 881-1150. WISCONSIN: Arrow/Schweber (414) 792-0150; Hall-Mark (414) 797-7844; Marshall (414) 797-8400. CANADA: Calgary: Future (403) 235-5325; Edmonton: Future (403) 438-2858; Montreal: Arrow/Schweber (514) 421-7411; Future (514) 694-7710; Marshall (514) 694-8142 Ottawa: Arrow/Schweber (613) 226-6903; Future (613) 820-8313. Quebec: Future (418) 897-6666. Toronto: Arrow/Schweber (416) 670-7769; Future (416) 612-9200; Marshall (416) 458-8046. Vancouver: Arrow/Schweber (604) 421-2333; Future (604) 294-1166. TI Die Processors Chip Supply Elmo Semiconductor Minco Technology Labs (407) 298-7100 (818) 768-7400 (512) 834-2022 Customer Response Center TOLL FREE: OUTSIDE USA: (800) 336-5236 (214) 995-6611 (8:00 a.m. – 5:00 p.m. CST) D0892 1992 Texas Instruments Incorporated SRPS013 IMPORTANT NOTICE Texas Instruments (TI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied on is current. TI warrants performance of its semiconductor products and related software to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. Certain applications using semiconductor products may involve potential risks of death, personal injury, or severe property or environmental damage (“Critical Applications”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, INTENDED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT APPLICATIONS, DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. Inclusion of TI products in such applications is understood to be fully at the risk of the customer. Use of TI products in such applications requires the written approval of an appropriate TI officer. Questions concerning potential risk applications should be directed to TI through a local SC sales office. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards should be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein. Nor does TI warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. Copyright 1996, Texas Instruments Incorporated