ETC CX12LC

05017
CX12
thru
CX12LC
. . . engineered solutions for the transient environment™
COAXIAL PROTECTOR
APPLICATIONS
Surgebuster®
✔ High Speed Video Camera
✔ Coaxial Ethernet
✔ High Speed Data Lines
IEC COMPATIBILITY (EN61000-4)
✔ 61000-4-5 (Surge): 24A, 8/20µs - Level 2(Line-Gnd) & Level 3(Line-Line)
FEATURES
✔ Meets IEC 1000-4-5 Industry Requirements
✔ BNC Connection
✔ Low Capacitance
✔ Completely Enclosed Aluminum Housing
✔ Low Clamping Voltage
✔ Nanosecond Response Time
✔ Long Life and Maintenance Free
✔ Finger Safe Connectors
CX12 PACKAGE
FIGURE 1
TRANSIENT VOLTAGETHREAT
CONDITION
MECHANICAL CHARACTERISTICS
2K
Current - Amperes
✔ Metal Package
✔ Weight 161 Grams (Approximate)
✔ Device Marking: Part Number, Logo
DESCRIPTION
The CX12 series is a two stage, hybrid surge protector designed to protect interfacing equipment from
induced lightning or switching transients. The multistage technique has proven to be the most cost
effective and reliable method for protecting sensitive electronic equipment. Employing state-of-the-art
avalanche junction diode technology, these devices provide superior performance for video, Ethernet,
Token Ring or other LAN interface systems. They are in-line modules with easy interconnecting terminals. A
completely enclosed aluminum housing provides EMC shielding to meet industry standard requirements.
The enclosure has two female BNC type connections for easy installation. The case is ground for those
installations that require external ground connections.
FIGURE 3
LINEAR VS NON-LINEAR CAPACITANCE
100
ProTek’s
CX12LC
20
40
60
80
Time µs
100 120 140
160
FIGURE 2
CX 12LC CLAMPING VOLTAGE
120
10
0
1
2
3
4
5
V(OP) - Circuit Operating - Volts
tf
100
Peak Value IPP
80
e-t
Test
Waveform
Parameters
tf = 8µs
td = 20µs
60
40
td = t
20
0
IPP/2
30
20
10
0
0
0
5
10
15
20
25
30
20
40
60
80 100 120 140
Time µs
160
t - Time - µs
Figure 1 and 2 are photographs of digitized waveforms
showing a typical transient voltage and the clamping
action of the CX12LC module. The device was subjected to a 2000A, 8/20µs impulse waveform in accordance with ANSI C62.36. The CX12 has an operating
frequency range up to 10MHz and the CX12LC up to
100MHz.
Figure 3 shows a comparison of capacitance between a
industrial standard device (Top Line) and the ProTek Device
CX12LC (Bottom Line). Due to the drastic change in the
capacitance of the product (Top Line), signal distortion,
loss of data or even access into the computer may be a
problem.
05017.R2 7/02
0
Current - Amperes
Industry Standard
Low Capacitance
Solid State Protector
0
FIGURE 4
PULSE WAVE FORM
IPP - Peak Pulse Current - % of IPP
C - TVS Capacitance - pF
1000
1K
1
www.protekdevices.com
CX12
and
CX12LC
DEVICE CHARACTERISTICS
MAXIMUM RATINGS @ 25°C
Peak Operating Line Voltage (V OP )
Operating Line Current (I O )
Maximum Transient Voltage
Maximum Transient Current
Maximum Leakage Current
CX12 Frequency Responce -3 dB
CX12LC Frequency Responce -3 dB
Operating & Storage Temperature
Response Time
ELECTRICAL CHARACTERISTICS @ 25°C
±12 V
200mA
20kV
3000A (8/20µs)
5µA
@ 30MHz
@ 200MHz
-40° to +85°C
< 10 ns
PROTEK
PART
NUMBER
MAXIMUM
CLAMPING
VOLTAGE
*
Line-Ground
500A @ 8/20 ms
VC
MAXIMUM
LINE
THRUPUT
RESISTANCE
TYPICAL
CAPACITANCE
R
C
@ 0 V, 1 MHz
VOLTS
OHMS
pF
24
28
3
10
200
25
CX12
CX12LC
* Other Voltages Available Consult Factory
Frequency Responce CX12
1.21”
(30.73 mm)
1.10”
(27.94 mm)
1.40”
(35.56 mm)
1.10”
(27.54 mm)
0.15”
(3.81mm)
0.72”
(18.29 mm)
CX12 COAXIAL
LINE PROTECTOR
CX 12 - COAXIAL
LINE PROTECTOR
CAUTION:
Mounting
plate
must be
Mounting
plate
must
CAUTION:
connectedtoto
earth
ground
be connected
earth
ground
2.95”
(74.93 mm)
3.25”
(82.55 mm)
0.150” DIA. (3.81 mm) Mounting Holes
LINE
Frequency Responce CX12LC
2.25”
(57.15 mm)
EQUIPMENT
INSTALLATION
05017.R2 7/02
2
0.70”(17.78 mm)
The CX12 series is designed with a female BNC type connector on both ends for
easy installation. Disconnect the video or data line from the sensitive equipment.
Insert the CX12 in the line near the AC power outlet of the equipment to be
protected. Install a cable in between the CX12 and the equipment to be protected. Attach a ground wire between the case of the CX12 and the equipment AC
power ground, or to the coax shield as required.
0.72”
(18.29 mm)
www.protekdevices.com