Electronic components CZ MKP Metallized Polypropylene Film Capacitors MKP 380S - 386S 5 40 Lmax Construction of capacitors: Metallized polypropylen film capacitors noninductive construction, cylindric shape, self-healing ability, Leads: tinned cooper wire Surface coating by yellow polyester film tape wraped, epoxy resin sealed Flame retardand construction available upon request also UL 94 V-0 5 Reference standards: General specifications: IEC 60384-1, EN 130 000 Sectional specifications:IEC 60386-16, CECC 31 200 d 40 Syllabova 380/41, 703 00 OSTRAVA - Vítkovice Phone: +420/ 595 781 623, 596 623 385 Fax: +420/ 595 781 612, 596 623 386 E - mail: [email protected] Web Site:http://www.es-ostrava.cz D max L1 Nominal capacitanceCR: see table Other values on request. Nominal capacitance values are based on the E6 serie in accordance to IEC 63 publ. or arbitrary values in capacitance range on request. Tolerance of capacitance: ± 20% (M), ± 10% (K), ± 5%(J), arbitrary tolerances on request L max (mm) 11 14 19 26 31 36 d (mm) 0,6 0,6 0,6 0,8 0,8 0,8 L1 (mm) 16 20 25 32,5 37,5 41 Insulation resistance Ris: C Î 0,33µF Ris min. 100 000 MÂ C > 0,33µF tis min. 30 000 sec. Time constant tis: tis=Ris . C [sec;MÂ;µF] Rated voltage UR [DC/AC 50-60 Hz] - see table. Climatic category: 55/100/56 (IEC 60068-1) Maximum pulse rise time dU/dt [V/µsec] Working Temperature range: - 55°C ÷ +100°C Lmax (mm) UR 160 250 400 630 1000 1600 2000 Î 14 î 31 26 19 dU/dt [V/ µs] max. 45 75 60 100 100 150 120 200 160 250 200 300 450 650 100 120 200 250 300 500 750 30 45 60 100 140 175 250 CRÎ 0,1µF 0,0006 0,0010 0,0030 0,1µFÎ CRÎ1µF 0,0006 0,0020 CR>1µF 0,0006 Operating voltage dependence on ambient temperature Uop/UR [%] Type MKP 380S MKP 381S MKP 382S MKP 383S MKP 384S MKP 385S MKP 386S Nominal voltage 160 UR DC/AC 100 Dissipation factor tgç at +25°C max. 1 kHz 10 kHz 100 kHz Test voltage between terminations: UT=1,6 × UR for 2 sec. at anbient temperature +25°C±5°C 100 80 60 40 250 160 630 250 * 1000 400 * 1600 630 2000 700 5x19 5x19 5x19 6x19 5x26,5 5,5x26,5 6,5x26,5 7x26,5 8x26,5 9,5x26,5 10,5x26,5 13,5x26,5 12,5x31,5 15,5x31,5 16x31,5 22x31,5 5x26,5 5x26,5 5x26,5 7x26,5 5x31,5 6,5x31,5 7x31,5 7,5x31,5 8x31,5 9x31,5 10,5x31,5 12,5x31,5 15x31,5 18x31,5 22x31,5 Maximal dimensions D x L (mm) Nom. capac.CR 1000 pF 1500 2200 3300 4700 6800 0,010 µF 0,015 0,022 0,033 0,047 0,068 0,10 µF 0,15 0,22 0,33 0,47 0,68 1,0 µF 1,5 2,2 3,3 4,7 6,8 10 µF 400 220 * 7x11 7,5x14 8,5x14 10x14 8x19 9x19 10,5x19 10x26 12,5x26 14,5x26 16x31 19x31 21x36 5x11 5x14 6x14 8,5x14 5x19 6x19 7x19 7,5x26 8x26 9x26 9,5x31 11x31 13,5x31 16x31 17,5x36 5x11 5x14 5,5x14 6,5x14 5,5x19 6x19 6,5x19 7x19 7x26 8x26 9,5x26 10x31 11,5x31 14x31 16x31 18x36 21,5x36 5x11 5x11 5x11 5x11 5,5x11 5,5x14 5,5x14 6x14 5,5x19 6,5x19 7x19 8x19 7,5x26 8x26 8,5x26 9x31 10x31 12x31 15x31 17,5x36 20,5x36 5x11 5x14 5x14 5x14 5,5x19 5,5x19 5,5x19 5,5x19 7x26 8x26 9x26 8x31 9,5x31 11x31 13x31 14,5x31 17x31 19x36 21x36 * this capacitors are not suitable for across the line applications The manufacturer is not responsible for any damages, caused by the improper instalation and application. 20 -60 -40 -20 0 20 40 60 80 100 [°C] K150302-3 MKP Metallized Polypropylene Film Capacitors Maximum AC voltage dependence on frequency Electronic components CZ Syllabova 380/41, 703 00 OSTRAVA - Vítkovice Phone: +420/ 595 781 623, 596 623 385 Fax: +420/ 595 781 612, 596 623 386 E - mail: [email protected] Web Site:http://www.es-ostrava.cz Upper operating temperature: The max. temperature measured on the case surface at which the capacitor can work continualy. MKP capacitors have the upper operating temperature +100°C, at any rate +105°C and corresponds to the upper category temperature Category voltage UC: The maximum direct voltage, or the maximum r.m.s. voltage or the max. value of a voltage pulse, which may be continuously applied to the terminals of a capacitors till to the rated temperature. For the MKP up to +85°C UC=UR. For temperatures between +85°C and +100°C a decreasing factor of 1,25%/°C on the rated voltage UR has to be applied. Pulse loading: The capacitors charged which unsinusoidal voltage pulses with quick rise (high dU/dt) will be loaded with high current pulses. The current pulse must be limited in order to not overload or not destroy the internal contact and connections. The limit of alowed current loading is given with allowed voltage rise in time dU/dt [V/µsec] Minimum resistance in series with capacitor is Rs=UR/CR × dU/dt UR - rated voltage [V] CR - nominal capacitance [µF] Rs - [Ohm] If the max. pulse voltage is less than the rated voltage, higher dU/dt values can be permited dUOP/dt = dUR/dt × UR/UOP UR - rated votage UOP - working voltade amplitude Permisible AC Voltage: It is the pure sine wave voltagethat may be applied to the capacitor at the frequency up to 50/60 Hz. For the operation at higher frequencies refer to permisible AC voltage versus frequency graphs. Time constant tis: The time constant is used to express the quality of insulance for higher capacities and is expressed in second with the following formula: tis=Ris . C [sec;MÂ;µF] K150302-3