ETC T2SBA40

T2SBA Series (SIP)
1.5-AMPERE SILICON BRIDGE RECTIFIER
Mechanical Data
FEATURES
•
•
•
•
•
•
Low Reverse Leakage Current
Surge Overload Rating to 60A Peak
Ideal for Printed Circuit Board Applications
Epoxy Material – UL Recognition
Flammability Classification 94V-0
•
Case:
Molded Epoxy Resin
Terminals: Plated Leads, Solderable
per MIL-STD-202, Method 208
Polarity: Molded on Body
2542 Highlander Way ! Carrollton, TX 75006
UNIT: mm
Peak Repetitive Reverse Voltage
Average Rectified Output Current @ Ta = 25ºC
T2SBA40
T2SBA60
T2SBA80
UNIT
VRRM
400
600
800
V
VR(RMS)
280
420
560
V
Io
1.5
A
Non-Repetitive Peak Forward Surge Current
10 mS single half sine-wave superimposed on rated load
IFSM
60
A
Maximum Forward Voltage per Element, IF = 0.75 A
VF
1.05
V
Peak Reverse Current per element at VR = VRRM
IR
10
µA
TJ ,Tstg
-40 to +150
°C
Operating and Storage Temperature Range
Manufactured by Tianjin Zhong – Huan Semiconductor Co., Ltd.
Rev 0, Sep 2002
www.collmer.com
RMS Reverse Voltage
SYMBOL
972-248-2888
Maximum Ratings & Characteristics
Single Phase, 60 Hz, Resistive or Inductive Load
Ta = 25ºC Unless Otherwise Specified
CHARACTERISTIC
T2SBA Series (SIP)
P - Io Curve
Forward Voltage
3.5
3
8
7
6
5
4
3
2
1
0
TJ=150C
2.5
TJ=25C
P (W)
IF (A)
10
9
2
1.5
1
0.5
0
0.4
0.6
0.8
VF (V)
1
0 0.2 0.4 0.6 0.8
1.2
1 1.2 1.4 1.6 1.8
Io (A)
2
Current Derating
Surge Forward Current
1.6
1.4
50
1.2
1
0.8
0.6
40
Io (A)
IFSM (A)
Tc at PCB Pad (3 mm)
60
30
0.4
0.2
0
20
10
1
10
Cycles
100
0
25
50
75
100
Tc (C)
125
150
175
In order to avoid damaging devices, please observe the following precautions:
1. When using automated soldering equipment, use 60/40 (Sn/Pb) solder (melting point of 180ºC) with a neutral flux
similar to rosin. Preheat time should be limited to 1 – 2 minutes at 150ºC.
2. When using a soldering iron, use a tip temperature of less than 300ºC (or a soldering iron power of less than
60W). Keep the soldering time below 5 seconds.
3. After soldering, remove any flux residue to avoid corrosion.
4. Because over-voltage or over-current testing may cause permanent damage to the devices, be sure to check the
test equipment for proper voltage, current and ground connection prior to beginning the test.
5. If the devices are to be encapsulated, they should be cleaned and dried at 120º ± 5ºC for at least 24 hours prior to
encapsulation. Test for compatibility between the device package and the encapsulation material.