ETC T10XB40

T10XB Series (SIP)
10-AMPERE SILICON BRIDGE RECTIFIER
Mechanical Data
FEATURES
•
•
•
•
•
•
Low Reverse Leakage Current
Surge Overload Rating to 120A Peak
Ideal for Printed Circuit Board Applications
Epoxy Material – UL Recognition
Flammability Classification 94V-0
•
Case:
Molded Epoxy Resin
Terminals: Plated Leads, Solderable
per MIL-STD-202, Method 208
Polarity: Molded on Body
2542 Highlander Way ! Carrollton, TX 75006
UNIT: mm
Maximum Ratings & Characteristics
SYMBOL
T10XB40
T10XB60
T10XB80
UNIT
VRRM
400
600
800
V
VR(RMS)
280
420
560
V
Peak Repetitive Reverse Voltage
RMS Reverse Voltage
Io
10.0
A
Average Rectified Output Current @ Ta = 25ºC w/o cooling fin
Io
2.7
A
Non-Repetitive Peak Forward Surge Current
10 mS single half sine-wave superimposed on rated load
IFSM
120
A
Maximum Forward Voltage per Element, IF = 5.0 A
VF
1.05
V
Peak Reverse Current per element at VR = VRRM
IR
10
µA
TJ ,Tstg
-40 to +150
°C
Operating and Storage Temperature Range
Reference Table for Heat-Sink Size
Average Rectified Output Current in Amps
2
Cooling Fin Single-face Area S1 (cm )
2
Cooling Fin Single-face Area S2 (cm )
3.0
4
8
5.0
75
65
7.5
180
100
9
500
310
11
900
490
Note: Vertical Mounting at Ta = 40ºC. HS Material: S1 = 1.5mm-Thick Aluminum, S2 = 3.0mm-Thick Copper
Manufactured by Tianjin Zhong – Huan Semiconductor Co., Ltd.
Rev 0, Sep 2002
www.collmer.com
Average Rectified Output Current @ TC = 108ºC w/ cooling fin
972-248-2888
Single Phase, 60 Hz, Resistive or Inductive Load
Ta = 25ºC Unless Otherwise Specified
CHARACTERISTIC
T10XB Series (SIP)
P - Io Curve
Forward Voltage
12
14
10
12
P (W)
IF (A)
10
TJ=150C
TJ=25C
8
6
8
6
4
4
2
2
0
0
0.4
0.5
0.6
0.7 0.8
VF (V)
0.9
1
0
1.1
1
3
Io (A)
4
5
6
Current Derating
Surge Forward Current
130
120
10
110
Without HS: Tc at PCB Pad (5 mm)
With HS: Tc Next to HS Mounting
8
100
90
80
70
W/O HS
W/ HS
Io (A)
IFSM (A)
2
6
4
2
60
50
0
1
10
Cycles
100
0
25
50
75
100
Tc (C)
125
150
175
In order to avoid damaging devices, please observe the following precautions:
1. When using automated soldering equipment, use 60/40 (Sn/Pb) solder (melting point of 180ºC) with a neutral flux
similar to rosin. Preheat time should be limited to 1 – 2 minutes at 150ºC.
2. When using a soldering iron, use a tip temperature of less than 300ºC (or a soldering iron power of less than
60W). Keep the soldering time below 5 seconds.
3. After soldering, remove any flux residue to avoid corrosion.
4. Because over-voltage or over-current testing may cause permanent damage to the devices, be sure to check the
test equipment for proper voltage, current and ground connection prior to beginning the test.
5. If the devices are to be encapsulated, they should be cleaned and dried at 120º ± 5ºC for at least 24 hours prior to
encapsulation. Test for compatibility between the device package and the encapsulation material.