LEM LF305-S

Current Transducer LF 305-S
IPN
=
300 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Preliminary
Electrical data
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
IPN
IP
RM
with ± 12 V
with ± 15 V
with ± 20 V
@ ± 300 A max
@ ± 500 A max
@ ± 300 A max
@ ± 500 A max
@ ± 300 A max
@ ± 500 A max
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
ISN
KN
VC
IC
Vd
300
0 .. ± 500
RM min
RM max
A
A
0
0
0
0
15
15
Ω
Ω
Ω
Ω
Ω
Ω
39
12
58
22
93
45
150
mA
1 : 2000
± 12 .. 20
V
16 (@ ± 20 V) + IS mA
3
kV
Accuracy - Dynamic performance data
Overall accuracy @ IPN , TA = 25°C
Linearity
XG
ε
L
± 0.4
< 0.1
IO
IOM
IOT
Offset current @ IP = 0, TA = 25°C
Residual current 1) @ IP = 0, after an overload of 3 x IPN
Thermal drift of IO
- 10°C .. + 70°C
Max
± 0.20
± 0.08
± 0.1 ± 0.30
tra
tr
di/dt
f
Reaction time @ 10 % of IPN
Response time 2) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
< 500
<1
> 100
DC .. 100
%
%
Features
• Closed loop (compensated) current
transducer using the Hall effect
• Insulated plastic case recognized
according to UL 94-V0.
Advantages
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
• Current overload capability.
Applications
Typ
mA
mA
mA
ns
µs
A/µs
kHz
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
General data
TA
TS
RS
m
Notes :
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ TA = 70°C
Mass
Standards 3)
1)
2)
3)
- 10 .. + 70
- 25 .. + 85
28
95
EN 50178
°C
°C
Ω
g
applications.
The result of the coercive field of the magnetic circuit
With a di/dt of 100 A/µs
A list of corresponding tests is available
991125/1
LEM Components
w w w .lem.com
Dimensions LF 305-S
(in mm. 1 mm = 0.0394 inch)
Bottom view
Secondary terminals
Pin + : supply voltage + 12 .. 20 V
Pin M : measure
Pin - : supply voltage - 12 .. 20 V
Right view
Back view
Connection
Top view
Mechanical characteristics
Remarks
•
•
•
•
• IS is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
General tolerance
Fastening
Primary through-hole
Connection of secondary
± 0.5 mm
see drawing
∅ 20 mm
Molex 5045-03/AG
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.