LEM LV100-100

Voltage Transducer LV 100-100
VPN = 100 V
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Electrical data
VPN
VP
IPN
RM
Primary nominal r.m.s. voltage
Primary voltage, measuring range
Primary nominal r.m.s. current
Measuring resistance
with ± 15 V
ISN
KN
VC
IC
Vd
100
V
0 .. ± 150
V
100
mA
RM min
RM max
@ ± 100 V max
@ ± 150 V max
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
0
0
170
90
Ω
Ω
50
mA
100 V / 50 mA
± 15
V
10 + IS
mA
6
kV
Accuracy - Dynamic performance data
XG
ε
L
Overall Accuracy @ VPN , TA = 25°C
Linearity
± 0.7
< 0.1
Typ
IO
IOT
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
tr
Response time @ 90 % of VPN
0°C .. + 70°C
± 0.2
%
%
Max
± 0.2
± 0.3
50
Ambient operating temperature
Ambient storage temperature
Turns ratio
Total primary power loss
Primary resistance @ TA = 25°C
Secondary coil resistance @ TA = 70°C
Mass
Standards
• Closed loop (compensated) voltage
transducer using the Hall effect
• Insulated plastic case recognized
according to UL 94-V0
• Primary resistor R 1 incorporated into
the housing.
Advantages
•
•
•
•
Excellent accuracy
Very good linearity
Low thermal drift
High immunity to external
interference.
Applications
mA
mA
• AC variable speed drives and servo
µs
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
General data
TA
TS
N
P
R1
RS
m
Features
motor drives
(UPS)
0 .. + 70
- 25 .. + 85
1000 : 2000
10
1
60
850
EN 50178
°C
°C
• Power supplies for welding
applications.
W
kΩ
Ω
g
030224/2
LEM Components
w w w .lem.com
Dimensions LV 100-100
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Connection
Top view
Mechanical characteristics
• General tolerance
• Transducer fastening
•
•
•
•
Fastening torque max
Connection of primary
Connection of secondary
Connection to the ground
Fastening torque max
Remarks
± 0.3 mm
2 holes ∅ 6.5 mm
M6 steel screws
5 Nm or 3.69 Lb - Ft.
M5 threaded studs
Faston 6.3 x 0.8 mm
M5 threaded stud
2.2 Nm or 1.62 Lb. -Ft.
• IS is positive when VP is applied on terminal +HT.
• The primary circuit of the transducer must be linked to the
connections where the voltage has to be measured.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.