LITTELFUSE SL0902A090

High Performance Beta Range
RoHS
Greentube™ SL0902 Series Gas Plasma Arresters
Pb
®
The Broadband Optimized™ SL0902 series has been especially
developed to offer high surge ratings in a miniature package. Unique
design features offer high levels of performance on fast rising transients in the domain of 100V/µs to 1kV/µss, which are those most
likely from induced lightning disturbances.
The device offers low insertion loss, so is well suited to braodband
equipment. The capacitance does not vary with voltage, so will not
cause operational problems with ADSL2+ where capacitance variation across Tip and Ring is undesirable. These devices are extremely robust and are able to divert a 2500A pulse without destruction.
For AC Power Cross of long duration, overcurrent protection is recommended.
FEATURES
• RoHS compliant
• GHz working frequency
5.0 ±0.2
• Excellent stability on multiple pulse duty cycle
• Excellent response to fast rising transients.
• Ultra Low Insertion Loss
• Surface mountable
• 2.5KA surge capability tested with 8/20mS pulse
5.0 ±0.2
as defined by IEC 61000-4-5
Applications:
• Broadband equipment.
SL0902AxxxSM
• ADSL equipment, including ADSL2+.
• XDSL equipment.
• Satellite and CATV equipment.
5.0 ±0.2
• General telecom equipment.
GDT SHOWING SEATING PLANE
FOR SL0902AxxxSM
2 ELECTRODE GDT
All dimensions in mm
GRAPHICAL SYMBOL
ORDERING INFORMATION
SL 0902 A XXX
SM
Mechanical Specifications:
SM=Surface mount
Voltage
Type
2 Pole Mini Arrester
323
Weight:
Materials:
Device Marking:
Packaging:
w w w. l i t t e l f u s e . c o m
0.33g (0.011 oz.)
Electrode Base: Copper Alloy
Electrode Plating: Bright Tin
Body: Ceramic
‘LF’ logo, Voltage and date code
Tape and Reel to EIA RS-296-D, 1500 pieces
Bulk in vacuum sealed bags, 1000 pieces
High Performance Beta Range
RoHS
Pb
Greentube™ SL0902 Series Gas Plasma Arresters
®
LITTELFUSE 2 TERMINAL MINI ARRESTER SERIES
TOTALLY NON-RADIOACTIVE, UL RECOGNIZED
DC
Max Dynamic
Breakover
breakover
Voltage @
Voltage @
Part Number 2KV/sec(1,2) 100V/µs (Vbr)
SL0902A090
300
72-108
SL0902A230
SL0902A350
SL0902A420
(7)
AC
Max Dynamic
Breakover Discharge
Voltage @ 1 Current(4)
kV/µs (Vbr)
(A)
2.5
550
Insulation
Max
Resistance(6) Capacitance
Impulse
Discharge
Current(5)
Holdover
(KA)
(Ohms)
(pF)
(V)
Nominal
On-State
Voltage
@ 1A (V)
2.5
1x109
1.5
50
20
Voltage(3)
184-276
400
500
2.5
2.5
1x109
1.5
50
20
280-420
550
650
2.5
2.5
1x109
1.5
50
20
2.5
1x109
1.5
50
20
675
350-504
2.5
800
Notes:
Voltage vs Time Characteristic
(1) At delivery AQL 0.65 level II, DIN ISO 2869
Max dynamic breakover
voltage
(2) In ionized mode
8
GAS DISCHARGE
TUBES
(3) Tested according to ITU-T Rec.K12
Voltage
(V)
(4) 10 shots, A.C. 60Hz, 1sec. duration
(5) 10 shots, 8/20µs wave form per IEC 61000-4-5
(6) Measured @ 100V
(7) Pending UL approval
Hold-over voltage
On-State voltage
0
200
400
600
800
1000
1200
Time (ns)
Capacitance vs. Temperature @ Various Bias Voltages
0.66
0.65
Capacitance (pF)
0.64
0.63
0.62
Bias Voltage
5 volts
0 volts
0.61
15 volts
35 volts
25 volts
0.6
0.59
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
70
Temperature (˚C ) @ bias voltage
w w w. l i t t e l f u s e . c o m