MOSEL VITELIC V437316S04V 3.3 VOLT 16M x 72 HIGH PERFORMANCE UNBUFFERED ECC SDRAM MODULE PRELIMINARY Features Description ■ 168 Pin Unbuffered 16,777,216 x 72 bit Oganization SDRAM ECC DIMMs ■ Utilizes High Performance 128 Mbit, 16M x 8 SDRAM in TSOPII-54 Packages ■ Fully PC Board Layout Compatible to INTEL’S Rev 1.0 Module Specification ■ Single +3.3V (± 0.3V) Power Supply ■ Programmable CAS Latency, Burst Length, and Wrap Sequence (Sequential & Interleave) ■ Auto Refresh (CBR) and Self Refresh ■ All Inputs, Outputs are LVTTL Compatible ■ 4096 Refresh Cycles every 64 ms ■ Serial Present Detect (SPD) ■ SDRAM Performance The V437316S04V memory module is organized 16,777,216 x 72 bits in a 168 pin dual in line memory module (DIMM). The 16M x 72 memory module uses 9 Mosel-Vitelic 16M x 8 SDRAM. The x72 modules are ideal for use in high performance computer systems where increased memory density and fast access times are required. Part Number Speed Grade Configuration V437316S04VXTG-75PC -75PC, CL=2,3 (133 MHz) 16M x 72 V437316S04VXTG-75 -75, CL=3 (133 MHz) 16M x 72 V437316S04VXTG-10PC -10PC, CL=2,3 (100 MHz) 16M x 72 V437316S04VTG-75-01 V437316S04V Rev. 1.0 December 2001 1 MOSEL VITELIC V437316S04V Pin Configurations (Front Side/Back Side) Pin Front Pin Front Pin Front Pin Back Pin Back Pin Back 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 VSS I/O1 I/O2 I/O3 I/O4 VCC I/O5 I/O6 I/O7 I/O8 I/O9 VSS I/O10 I/O11 I/O12 I/O13 I/O14 VCC I/O15 I/O16 CB0 CB1 VSS NC NC VCC WE DQM0 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 DQM1 CS0 DU VSS A0 A2 A4 A6 A8 A10(AP) BA1 VCC VCC CLK0 VSS DU CS2 DQM2 DQM3 DU VCC NC NC CB2 CB3 VSS I/O17 I/O18 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 I/O19 I/O20 VCC I/O21 NC DU CKE1 VSS I/O22 I/O23 I/O24 VSS I/O25 I/O26 I/O27 I/O28 VCC I/O29 I/O30 I/O31 I/O32 VSS CLK2 NC WP SDA SCL VCC 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 VSS I/O33 I/O34 I/O35 I/O36 VCC I/O37 I/O38 I/O39 I/O40 I/O41 VSS I/O42 I/O43 I/O44 I/O45 I/O46 VCC I/O47 I/O48 CB4 CB5 VSS NC NC VCC CAS DQM4 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 DQM5 CS1 RAS VSS A1 A3 A5 A7 A9 BA0 A11 VCC CLK1 NC VSS CKE0 CS3 DQM6 DQM7 DU VCC NC NC CB6 CB7 VSS I/O49 I/O50 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 I/O51 I/O52 VCC I/O53 NC DU NC VSS I/O54 I/O55 I/O56 VSS I/O57 I/O58 I/O59 I/O60 VCC I/O61 I/O62 I/O63 I/O64 VSS CLK3 NC SA0 SA1 SA2 VCC Pin Names A0–A11 Address Inputs I/O1–I/O64 Data Inputs/Outputs RAS Row Address Strobe CAS Column Address Strobe WE Read/Write Input BA0, BA1 Bank Selects CKE0, CKE1 Clock Enable CS0–CS3 Chip Select CLK0–CLK3 Clock Input DQM0–DQM7 Data Mask VCC Power (+3.3 Volts) VSS Ground SCL Clock for Presence Detect V437316S04V Rev. 1.0 December 2001 2 SDA Serial Data OUT for Presence Detect SA0–A2 Serial Data IN for Presence Detect CB0–CB7 Check Bits (x72 Organization) NC No Connection DU Don’t Use MOSEL VITELIC V437316S04V Part Number Information V 4 3 73 16 S 0 4 V X T G - XX SPEED 75PC = PC133 CL3,2 75 = PC133 CL3 10PC = PC133 CL3,2 LEAD FINISH G = GOLD MOSEL VITELIC MANUFACTURED SDRAM 3.3V COMPONENT PACKAGE, T = TSOP WIDTH DEPTH COMPONENT A=0.17u B=0.14u REV LEVEL 168 PIN Unbuffered DIMM X8 COMPONENT LVTTL REFRESH RATE 4K 4 BANKS Block Diagram WE CS0 CS DQM WE I/O1–I/O8 DQM0 I/O1–I/O8 D0 DQM4 I/O40–I/O33 10 CS D1 DQM5 I/O48–I/O41 10 CB0–7 CS DQM WE I/O1–I/O8 CS WE DQM I/O1–I/O8 CS WE DQM I/O1–I/O8 CS D4 10 DQM WE I/O1–I/O8 DQM1 I/O9–I/O16 DQM WE I/O1–I/O8 D5 10 DQM WE I/O1–I/O8 CS WE DQM I/O1–I/O8 CS D8 10 CS2 DQM2 I/O17–I/O24 D2 DQM6 I/O49–I/O56 10 CS WE DQM I/O1–I/O8 DQM3 I/O25–I/O32 D3 DQM7 I/O57–I/O64 10 D7 10 E2PROM SPD (256 WORD X 8 BITS) SCL0 SA2 SA1 SA0 CKE0 CKE: SDRAM D0-D8 RAS RAS: SDRAM D0-D8 CAS CAS: SDRAM D0-D8 WE WE: SDRAM D0-D8 SDA WP 47K A(11:0) BA0, BA1 CLOCK WIRING CLOCK INPUT LOAD CLK0 CLK1 CLK2 CLK3 5 SDRAMS Termination 4 SDRAMS +3.3pF Cap Termination V437316S04V Rev. 1.0 December 2001 D6 10 VCC VSS A(11:0): SDRAM D0-D8 BA0, BA1: SDRAM D0-D8 D0-D8 C0-C15 D0-D8 V437316S04VTG-75-03 3 MOSEL VITELIC V437316S04V Serial Presence Detect Information written into the E2PROM device during module production using a serial presence detect protocol (I2C synchronous 2-wire bus) A serial presence detect storage device - is assembled onto the module. Information about the module configuration, speed, etc. is E2PROM SPD-Table Byte Number Function Described Hex Value SPD Entry Value -75PC -75 -10PC 0 Number of SPD bytes 128 80 80 80 1 Total bytes in Serial PD 256 08 08 08 2 Memory Type SDRAM 04 04 04 3 Number of Row Addresses (without BS bits) 12 0C 0C 0C 4 Number of Column Addresses (for x8 SDRAM) 10 0A 0A 0A 5 Number of DIMM Banks 1 01 01 01 6 Module Data Width 72 48 48 48 7 Module Data Width (continued) 0 00 00 00 8 Module Interface Levels LVTTL 01 01 01 9 SDRAM Cycle Time at CL=3 7.5 ns 75 75 A0 10 SDRAM Access Time from Clock at CL=3 5.4 ns 54 54 60 11 Dimm Config (Error Det/Corr.) ECC 02 02 02 12 Refresh Rate/Type Self-Refresh, 15.6µs 80 80 80 13 SDRAM width, Primary x8 08 08 08 14 Error Checking SDRAM Data Width n/a / x8 08 08 08 15 Minimum Clock Delay from Back to Back Random Column Address tccd = 1 CLK 01 01 01 16 Burst Length Supported 1, 2, 4, 8 0F 0F 0F 17 Number of SDRAM Banks 4 04 04 04 18 Supported CAS Latencies CL = 3 06 06 06 19 CS Latencies CS Latency = 0 01 01 01 20 WE Latencies WL = 0 01 01 01 21 SDRAM DIMM Module Attributes Non Buffered/Non Reg. 00 00 00 22 SDRAM Device Attributes: General Vcc tol ± 10% 0E 0E 0E 23 Minimum Clock Cycle Time at CAS Latency =2 Not Supported 75 A0 A0 24 Maximum Data Access Time from Clock for CL = 2 Not Supported 54 60 60 25 Minimum Clock Cycle Time at CL = 1 Not Supported 00 00 00 26 Maximum Data Access Time from Clock at CL = 1 Not Supported 00 00 00 27 Minimum Row Precharge Time 20 ns 0F 14 14 V437316S04V Rev. 1.0 December 2001 4 MOSEL VITELIC V437316S04V SPD-Table Byte Number Function Described Hex Value SPD Entry Value -75PC -75 -10PC 28 Minimum Row Active to Row Active Delay tRRD 15 ns 0E 0F 10 29 Minimum RAS to CAS Delay tRCD 20 ns 0F 14 14 30 Minimum RAS Pulse Width tRAS 45 ns 2A 2D 2D 31 Module Bank Density (Per Bank) 128 MByte 20 20 20 32 SDRAM Input Setup Time 1.5 ns 15 15 20 33 SDRAM Input Hold Time 0.8 ns 08 08 10 34 SDRAM Data Input Setup Time 1.5 ns 15 15 20 35 SDRAM Data Input Hold Time 0.8 ns 08 08 10 00 00 00 02 02 02 EC 31 8F 40 40 40 00 00 00 36-61 Superset Information (May be used in Future) 62 SPD Revision 63 Checksum for Bytes 0 - 62 64 Manufacturer’s JEDEC ID Code 65-71 72 Revision 2 Mosel Vitelic Manufacturer’s JEDEC ID Code (cont.) Manufacturing Location 73-90 Module Part Number (ASCII) 91-92 PCB Identification Code 93 Assembly Manufacturing Date (Year) 94 Assembly Manufacturing Date (Week) V437316S04V 95-98 Assembly Serial Number 99-125 Reserved 00 00 00 126 Intel Specification for Frequency 64 64 64 127 Reserved 00 00 00 Unused Storage Location 00 00 00 128+ DC Characteristics TA = 0°C to 70°C; VSS = 0 V; VDD, VDDQ = 3.3V ± 0.3V Limit Values Symbol Parameter Min. Max. Unit VIH Input High Voltage 2.0 VCC +0.3 V V IL Input Low Voltage –0.5 0.8 V V OH Output High Voltage (IOUT = –2.0 mA) 2.4 — V VOL Output Low Voltage (IOUT = 2.0 mA) — 0.4 V V437316S04V Rev. 1.0 December 2001 5 MOSEL VITELIC V437316S04V Limit Values Symbol Parameter Min. Max. Unit II(L) Input Leakage Current, any input (0 V < VIN < 3.6 V, all other inputs = 0V) –40 40 µA IO(L) Output leakage current (DQ is disabled, 0V < VOUT < VCC) –40 40 µA Capacitance TA = 0°C to 70°C; VDD = 3.3V ± 0.3V, f = 1 MHz Limit Values Symbol Parameter Max. 16M x 72 Unit CI1 Input Capacitance (A0 to A11, RAS, CAS, WE) 65 pF CI2 Input Capacitance (CS0-CS3) 40 pF CICL Input Capacitance (CLK0-CLK3) 40 pF CI3 Input Capacitance (CKE0, CKE1) 55 pF CI4 Input Capacitance (DQM0-DQM7) 20 pF CIO Input/Output Capacitance (I/O1-I/064) 20 pF CSC Input Capacitance (SCL, SA0-2) 8 pF CSD Input/Output Capacitance (SA0-SA2) 10 pF Absolute Maximum Ratings Parameter Max. Units Voltage on VDD Supply Relative to VSS -1 to 4.6 V Voltage on Input Relative to VSS -1 to 4.6 V Operating Temperature 0 to +70 °C -55 to 125 °C 7.5 W Storage Temperature Power Dissipation Operating Currents TA = 0°C to 70°C, VCC = 3.3V ± 0.3V (Recommended operating conditions otherwise noted) Max. Symbol ICC1 -75PC/75 -10PC Parameter & Test Condition 1 bank operation Operating Current tRC = tRCMIN., tRC = tCKMIN. Active-precharge command cycling, without Burst Operation V437316S04V Rev. 1.0 December 2001 6 1800 1350 Unit Note mA 7 MOSEL VITELIC V437316S04V Operating Currents TA = 0°C to 70°C, VCC = 3.3V ± 0.3V (Recommended operating conditions otherwise noted) (Continued) Max. Symbol ICC2P -75PC/75 -10PC Parameter & Test Condition Precharge Standby Current in Power Down Mode CS =VIH , CKE≤ VIL(max) ICC2PS ICC2N ICC3 ICC3P No Operating Current tCK = min, CS = VIH(min) bank ; active state ( 4 banks) Note tCK = min. 14 14 mA 7 tCK = Infinity 9 9 mA 7 400 315 mA tCK = Infinity 45 45 mA CKE ≥ VIH(MIN.) 495 405 mA CKE ≥ VIL(MAX.) (Power down mode) 90 90 mA 990 810 mA 7,8 7 Precharge Standby Current in Non-Power Down Mode tCK = min. CS =VIH , CKE≥ VIL(max) ICC2NS Unit ICC4 Burst Operating Current tCK = min Read/Write command cycling ICC5 Auto Refresh Current tCK = min Auto Refresh command cycling 2250 1890 mA ICC6 Self Refresh Current Self Refresh Mode, CKE=0.2V 14 14 mA 7.2 7.2 mA L-version Notes: 1. These parameters depend on the cycle rate and these values are measured by the cycle rate under the minimum value of tCK and tRC. Input signals are changed one time during tCK. 2. These parameter depend on output loading. Specified values are obtained with output open. AC Characteristics TA = 0° to 70°C; VSS = 0V; VCC = 3.3V ± 0.3V, tT = 1 ns Limit Values -75PC # Symbol Parameter -75 -10PC Min. Max. Min. Max. Min. Max. Unit Clock Cycle Time CAS Latency = 3 CAS Latency = 2 7.5 7.5 – – 7.5 10 – – 10 10 – – s ns ns Clock Frequency CAS Latency = 3 CAS Latency = 2 – – 133 133 – – 133 100 – – 100 100 MHz MHz Access Time from Clock CAS Latency = 3 CAS Latency = 2 – _ 5.4 6 – _ 5.4 6 – _ 6 6 ns ns Clock High Pulse Width 2.5 – 2.5 – 2.5 – ns Note Clock and Clock Enable 1 2 3 4 tCK tCK tAC tCH V437316S04V Rev. 1.0 December 2001 2, 4 7 MOSEL VITELIC V437316S04V AC Characteristics TA = 0° to 70°C; VSS = 0V; VCC = 3.3V ± 0.3V, tT = 1 ns (Continued) Limit Values -75PC # Symbol Parameter 5 tCL Clock Low Pulse Width 6 tT Transition Tim -75 -10PC Min. Max. Min. Max. Min. Max. Unit 2.5 – 2.5 – 2.5 – ns 1 – 1 – 1 – ns Note Setup and Hold Times 7 tIS Input Setup Time 1.5 – 1.5 – 1.5 – ns 5 8 tIH Input Hold Time 0.8 – 0.8 – 0.8 – ns 5 9 tCKS Input Setup Time 1.5 – 1.5 – 1.5 – ns 5 10 tCKH CKE Hold Time 0.8 – 0.8 – 0.8 – ns 5 11 tRSC Mode Register Set-up Time 15 – 15 – 15 – ns 12 tSB Power Down Mode Entry Time 0 7.5 0 7.5 0 7.5 ns Row to Column Delay Time 15 – 20 – 20 – ns 6 Common Parameters 13 tRCD 14 tRP Row Precharge Time 20 – 20 – 20 – ns 6 15 tRAS Row Active Time 42 100K 45 100K 45 100K ns 6 16 tRC Row Cycle Time 60 – 70 – 70 – ns 6 17 tRRD Activate(a) to Activate(b) Command Period 14 – 15 – 20 – ns 6 18 tCCD CAS(a) to CAS(b) Command Period 1 – 1 – 1 – CLK Refresh Cycle 19 tREF Refresh Period (4096 cycles) — 64 — 64 — 64 ms 20 tSREX Self Refresh Exit Time 10 — 10 — 10 — ns Read Cycle 21 tOH Data Out Hold Time 3 – 3 – 3 – ns 22 tLZ Data Out to Low Impedance Time 0 – 0 – 0 – ns 23 tHZ Data Out to High Impedance Time 3 7.5 3 7.5 3 8 ns 24 tDQZ DQM Data Out Disable Latency 2 – 2 – 2 – CLK Write Recovery Time 2 – 2 – 1 – CLK DQM Write Mask Latency 0 – 0 – 0 – CLK Write Cycle 25 tWR 26 tDQW V437316S04V Rev. 1.0 December 2001 8 2 7 MOSEL VITELIC V437316S04V Notes: 1. The specified values are valid when addresses are changed no more than once during tCK(min.) and when No Operation commands are registered on every rising clock edge during tRC(min). Values are shown per module bank. 2. The specified values are valid when data inputs (DQ’s) are stable during tRC(min.). 3. All AC characteristics are shown for device level. An initial pause of 100 µs is required after power-up, then a Precharge All Banks command must be given followed by 8 Auto Refresh (CBR) cycles before the Mode Register Set Operation can begin. 4. AC timing tests have VIL = 0.4V and V IH = 2.4V with the timing referenced to the 1.4V crossover point. The transition time is measured between VIH and VIL. All AC measurements assume tT = 1 ns with the AC output load circuit shown. Specific tac and toh parameters are measured with a 50 pF only, without any resistive termination and with a input signal of 1V / ns edge rate between 0.8V and 2.0V. + 1.4 V tCH 2.4V CLOCK 50 Ohm 0.4V tCL tSETUP Z=50 Ohm tT I/O tHOLD 50 pF 1.4V INPUT tAC tAC tLZ I/O tOH 50 pF 1.4V OUTPUT Measurement conditions for tac and toh tHZ 5. If clock rising time is longer than 1 ns, a time (tT/2 -0.5) ns has to be added to this parameter. 6. Rated at 1.5V 7. If tT is longer than 1 ns, a time (tT -1) ns has to be added to this parameter. 8. Any time that the refresh Period has been exceeded, a minimum of two Auto (CBR) Refresh commands must be given to “wake-up” the device. 9. Self Refresh Exit is a synchronous operation and begins on the 2nd positive clock edge after CKE returns high. Self Refresh Exit is not complete until a time period equal to tRC is satisfied once the Self Refresh Exit command is registered. 10. Referenced to the time which the output achieves the open circuit condition, not to output voltage levels. 11. tDAL is equivalent to tDPL + tRP. V437316S04V Rev. 1.0 December 2001 9 MOSEL VITELIC V437316S04V Package Diagram SDRAM DIMM Module Package All measurements in mm 133.35 (2.54 max) 10 11 40 41 84 3.0 1 17.78 35.00 127.35 42.18 1.27 ± 0.100 66.68 A 85 B 94 95 124 C 125 168 6.35 3.125 3.125 6.35 2.0 4.45 8.25 1.0 + 0.5 0.2 ± 0.15 2.0 Detail B Detail A 1.27 2.4 min. D 2.26 Detail C V437316S04VTG-75-04 RADIUS 1.27 + 0.10 Tolerances: ± (0.13) unless otherwise specified. V437316S04V Rev. 1.0 December 2001 10 MOSEL VITELIC V437316S04V Label Information Module Density MOSEL VITELIC Part Number Criteria of PC100 or PC133 (refer to MVI datasheet) DIMM manufacture date code V437316S04VXXX-XX 128MB CLX PC133U-XXX-542-A XXXX-XXXXXXX Assembly in Taiwan PC133 U -XXX UNBUFFERED DIMM A Gerber file Intel PC100 x8Based CL= 3 or 2 (CLK) tRCD= 3 or 2 (CLK) tRP= 3 or 2 (CLK) V437316S04V Rev. 1.0 December 2001 54 2 CAS Latency 2=CL2 3=CL3 JEDEC SPD Revision 2 tAC = 5.4 ns 11 MOSEL VITELIC WORLDWIDE OFFICES V437316S04V U.S.A. TAIWAN SINGAPORE UK & IRELAND 3910 NORTH FIRST STREET SAN JOSE, CA 95134 PHONE: 408-433-6000 FAX: 408-433-0952 7F, NO. 102 MIN-CHUAN E. ROAD, SEC. 3 TAIPEI PHONE: 886-2-2545-1213 FAX: 886-2-2545-1209 10 ANSON ROAD #23-13 INTERNATIONAL PLAZA SINGAPORE 079903 PHONE: 65-3231801 FAX: 65-3237013 NO 19 LI HSIN ROAD SCIENCE BASED IND. PARK HSIN CHU, TAIWAN, R.O.C. PHONE: 886-3-579-5888 FAX: 886-3-566-5888 JAPAN SUITE 50, GROVEWOOD BUSINESS CENTRE STRATHCLYDE BUSINESS PARK BELLSHILL, LANARKSHIRE, SCOTLAND, ML4 3NQ PHONE: 44-1698-748515 FAX: 44-1698-748516 ONZE 1852 BUILDING 6F 2-14-6 SHINTOMI, CHUO-KU TOKYO 104-0041 PHONE: 03-3537-1400 FAX: 03-3537-1402 GERMANY (CONTINENTAL EUROPE & ISRAEL) BENZSTRASSE 32 71083 HERRENBERG GERMANY PHONE: +49 7032 2796-0 FAX: +49 7032 2796 22 U.S. SALES OFFICES NORTHWESTERN SOUTHWESTERN 3910 NORTH FIRST STREET SAN JOSE, CA 95134 PHONE: 408-433-6000 FAX: 408-433-0952 302 N. EL CAMINO REAL #200 SAN CLEMENTE, CA 92672 PHONE: 949-361-7873 FAX: 949-361-7807 © Copyright , MOSEL VITELIC Inc. The information in this document is subject to change without notice. MOSEL VITELIC makes no commitment to update or keep current the information contained in this document. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of MOSEL-VITELIC. MOSEL VITELIC CENTRAL, NORTHEASTERN & SOUTHEASTERN 604 FIELDWOOD CIRCLE RICHARDSON, TX 75081 PHONE: 214-352-3775 FAX: 214-904-9029 Printed in U.S.A. MOSEL VITELIC subjects its products to normal quality control sampling techniques which are intended to provide an assurance of high quality products suitable for usual commercial applications. MOSEL VITELIC does not do testing appropriate to provide 100% product quality assurance and does not assume any liability for consequential or incidental arising from any use of its products. If such products are to be used in applications in which personal injury might occur from failure, purchaser must do its own quality assurance testing appropriate to such applications. 3910 N. First Street, San Jose, CA 95134-1501 Ph: (408) 433-6000 Fax: (408) 433-0952 Tlx: 371-9461