PhotoMOS RELAYS GU (General Use) Type [Multi-Channel (4-Channel) Type] FEATURES 5 max. .197 34 max. 1.339 18 max. .709 mm inch Q W E R T I Q Input Common: DC+ W Input 1: DC– E Input 2: DC– R Input 3: DC– T Input 4: DC– Y Output 1 (N.O.): O U Output 1 (N.O.): P I Output 2 (N.O.): { O Output 2 (N.O.): } P Output 3 (N.O.): q { Output 3 (N.O.): Y U DC or AC 7. PC board layout is simplified 8. Eliminates the need for a separate power supply to drive the power MOSFET 9. Low thermal electromotive force (Approx. 1 µV) 10. No restriction on mounting direction 11. No arc, no bounce, no noise 1. 4-circuit (4-Form A) of GU PhotoMOS Relay in a compact and slim 13 pin SIL 2. Applicable for 4 Form A use, as well as 4 independent 1 Form A 3. Controls low-level analog signals PhotoMOS relays feature extremely low closed-circuit offset voltage to enable control of low-level analog signals without distortion. 4. Low-level off state leakage current (Typical 100 pA at 100 V load voltage) 5. Optical coupling for extremely high isolation 6. Eliminates the need for a counter electromotive protection diode in the drive circuit on the input side TYPICAL APPLICATIONS • Telecommunication equipment • High speed inspection machine, Scanner, IC checker • Robots DC or AC DC or AC DC or AC DC or AC DC or AC } Output 4 (N.O.): DC or AC q Output 4 (N.O.): DC or AC TYPES AC/DC type Output rating* Load voltage Load current 400 V 80 mA Part No. AQX21444 Inner case 20 pcs. Packing quantity Outer carton 200 pcs. *Indicate the peak AC and DC values. RATINGS 1. AC/DC type 1. Absolute maximum ratings (Ambient temperature: 25°C 77°F) Item LED forward current LED reverse voltage Peak forward current Power dissipation Load voltage (peak AC) Symbol IF VR IFP Pin VL AQX21444 50 mA 3V 1A 75 mW 400 V Continuous load current IL 80 mA (100 mA) Peak load current Ipeak Power dissipation Total power dissipation I/O isolation voltage Operating Temperature limits Storage Pout PT Viso Topr Tstg 0.3 A 1,450 mW 1,500 mW 1,500 V AC –40°C to +85°C –40°F to +185°F –40°C to +100°C –40°F to +212°F Input Output 60 Remarks f = 100 Hz, Duty factor = 0.1% ( ): in case of using only 1 channel Peak AC, DC 100 ms (1 shot), VL = DC Non-condensing at low temperatures AQX21444 2. Electrical characteristics (Ambient temperature: 25°C 77°F) Item Symbol Typical Maximum Minimum Typical Typical Maximum LED operate current Input LED turn off current LED dropout voltage AQX21444 1.1 mA 3 mA 0.4 mA 1.0 mA 1.14 V (1.25 V at IF = 50 mA) 1.5 V IFon IFoff VF Ron Off state leakage current Maximum Shock resistance IF = 5 mA IL = 80 mA Within 1 s on time IF = 0 mA VL = 400 V 0.52 ms 2 ms 0.29 ms 1 ms 0.19 ms 0.5 ms 4.0 pF 8.0 pF IF = 5 mA IL = 80 mA Riso 1,000 MΩ 500 V DC — 10 to 55 Hz at double amplitude of 3 mm — 4,900 m/s2 {500 G} 1 ms Ton Toff Ciso Minimum IF = 5 mA 1 µA ILeak Typical Maximum Turn on time* Typical Switching speed Maximum Transfer Typical Turn off time* characteristics Maximum Typical I/O capacitance Maximum Initial I/O isolation Minimum resistance Vibration resistance Minimum IL = 80 mA 50 Ω Maximum Output IL = 80 mA 30 Ω Typical On resistance Condition IF = 10 mA IL = 80 mA IF = 5 mA or 10 mA IL = 80 mA f = 1 MHz VB = 0 2 hours for 3 axes 3 times for 3 axes Note: Recommendable LED forward current IF = 5 mA. For type of connection, see page 34. *Turn on/Turn off time Input 90% Output 10% Ton Toff ■ For Dimensions, see Page 29. ■ For Schematic and Wiring Diagrams, see Page 34. ■ For Cautions for Use, see Page 36. REFERENCE DATA 1. Load current vs. ambient temperature characteristics 2. Load current in adjacent mounting vs. ambient temperature 3. On resistance vs. ambient temperature characteristics Allowable ambient temperature: –40°C to +85°C –40°F to +185°F Condition: 4 circuits ON status Measured portion: between terminals 6 and 7, 8 and 9, 10 and 11, 12 and 13; LED current: 5 mA; Continuous load current: 80 mA (DC) 120 1 circuit ON status 80 2 circuit ON status 60 3 circuit ON status 40 100 Load current, mA Load current, mA 100 120 =20mm =10mm 80 =5mm 60 40 100 On resistance, Ω 120 80 60 40 4 circuit ON status 20 20 20 =Adjacent mounting pitch 0 –40 –20 0 20 40 60 8085 100 Ambient temperature, °C 0 –40 –20 0 20 40 60 8085 100 Ambient temperature, °C 0 –40 –20 0 20 40 60 80 85 Ambient temperature, °C 61 AQX21444 4. Turn on time vs. ambient temperature characteristics 5. Turn off time vs. ambient temperature characteristics 6. LED operate current vs. ambient temperature characteristics Load voltage: 400 V (DC); Continuous load current: 80 mA (DC) Load voltage: 400 V (DC); Continuous load current: 80 mA (DC) Load voltage: 400 V (DC); Continuous load current: 80 mA (DC) 0.5 IF=5mA 1.0 5 LED operate currnt, mA 1.5 Turn off time, ms Turn on time, ms 2.0 0.4 0.3 0.2 IF=10mA 0.5 IF=10mA 0.1 4 3 2 1 IF=5mA 0 –40 –20 0 20 40 60 8085 0 Ambient temperature, °C –40 –20 0 0 20 40 60 80 85 Ambient temperature, °C –40 –20 0 20 40 60 80 85 Ambient temperature, °C 7. LED turn off current vs. ambient temperature characteristics 8. LED dropout voltage vs. ambient temperature characteristics 9. Voltage vs. current characteristics of output at MOS portion Load voltage: 400 V (DC); Continuous load current: 80 mA (DC) LED current: 5 to 50 mA Measured portion: between 6 and 7, 8 and 9, 10 and 11, 12 and 13; Ambient temperature: 25°C 77°F 1.5 4 3 2 1 100 Current, mA LED dropout voltage, V LED turn off current, mA 5 1.4 1.3 80 60 40 20 –5 –4 –3 –2 –1 1.2 1 –20 50mA 30mA 20mA 10mA 5mA 1.1 1.0 2 3 4 5 Voltage, V –40 –60 –80 0 –40 –20 0 20 40 60 0 –40 –20 80 85 Ambient temperature, °C 10. Off state leakage current Measured portion: between terminals 6 and 7, 8 and 9, 10 and 11, 12 and 13; Ambient temperature: 25°C 77°F –100 0 20 40 60 8085 100 Ambient temperature, °C 11. LED forward current vs. turn on time characteristics 12. LED forward current vs. turn off time characteristics Measured portion: between terminals 6 and 7, 8 and 9, 10 and 11, 12 and 13; Load voltage: 400 V (DC); Continuous load current: 80 mA (DC); Ambient temperature: 25°C 77°F Measured portion: between terminals 6 and 7, 8 and 9, 10 and 11, 12 and 13; Load voltage: 400 V (DC); Continuous load current: 80 mA (DC); Ambient temperature: 25°C 77°F 0.5 2.5 10-6 10-9 0.4 Turn off time, ms Turn on time, ms Off state leakage current, A 3.0 10-3 2.0 1.5 1.0 0.3 0.2 0.1 0.5 10 -12 50 Load voltage, V 0 100 0 0 10 20 30 40 50 Load forward current, mA 0 0 10 20 30 40 50 LED forward current, mA 13. Applied voltage vs. output capacitance characteristics (AC/DC type) Output capacitance,pF Measured portion: between terminals 6 and 7, 8 and 9, 10 and 11, 12 and 13; Load voltage: 400 V (DC); Frequency: 1 MHz; Ambient temperature: 25°C 77°F 50 40 30 20 10 0 5/7/2001 62 0 10 20 30 40 50 Applied voltage, V All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog