DATA SHEET TFT COLOR LCD MODULE NL8060BC26-17 26 cm (10.4 inches), 800 × 600 pixels, 262144 colors High luminance, Wide viewing angle DESCRIPTION NL8060BC26-17 is a TFT (thin film transistor) active matrix color liquid crystal display (LCD) module comprising amorphous silicon TFT attached to each signal electrode, a driving circuit, and a backlight. NL8060BC26-17 has a built-in backlight. The backlight includes long-life-lamps and the lamps are replaceable with a holder. The 26 cm diagonal display area contains 800 × 600 pixels and can display 262144 color simultaneously. NL8060BC26-17 is suitable for industrial application use, because the viewing angle is wide and the luminance is high. Also, the viewing direction is selectable either upper or lower side by changing scan direction. FEATURES • High luminance (280 cd/m2, typ.) • Wide viewing angle (with Retardation film) • Low reflection • Reversible scan direction • 6-bit digital RGB input signals • Data enable (DE) function • Edge type backlight with two long-life-time lamps (one lamp holder) • Lamp holder replaceable • Recommended inverter for a backlight: Part No. 104PWBR1 APPLICATIONS • Display terminals for control system • Monitors for process controller The information in this document is subject to change without notice. Please confirm with the delivery specification before statting to design the system. Document No. EN0493EJ1V0DS00 Date Published February 2000 P Printed in Japan 2000 NL8060BC26-17 STRUCTURE AND FUNCTIONS A color TFT (thin film transistor) LCD module is comprised of a TFT liquid crystal panel structure, LSIs for driving the TFT array, and a backlight assembly. The TFT panel structure is created by sandwiching liquid crystal material in the narrow gap between a TFT array glass substrate and a color filter glass substrate. After the driver LSIs are connected to the panel, the backlight assembly is attached to the backside of the panel. RGB (red, green, blue) data signals from a source system is modulated into a form suitable for active matrix addressing by the onboard signal processor and sent to the driver LSIs which in turn addresses the individual TFT cells. Acting as an electro-optical switch, each TFT cell regulates light transmission from the backlight assembly when activated by the data source. By regulating the amount of light passing through the array of red, green, and blue dots, color images are created with clarity. BASIC STRUCTURE 47 Ω H-driver R0 - R5 47 Ω · · · · · · Digital signal processor G0 - G5 47 Ω Level shift 2400 lines B0 - B5 V-driver 47 Ω CLK 47 Ω H sync 47 Ω LCD timing controller V sync 47 Ω DE 47 Ω MODE DPS 47 kΩ VCC VH VL Power supply circuit LSIs Drivers Back light GND (SG) Frame * Frame is not connected with GND (SG). 2 Data Sheet EN0493EJ1V0DS00 · · · · · TFT LCD panel 600 lines H: 800 × 3 (R, G, B) V: 600 NL8060BC26-17 <In case of connecting NEC recommended inverter> VDDB Inverter Back light BRTHL BRTC (Part No: 104PWBR1) BRTH BRTL GNDB OUTLINE OF CHARACTERISTICS (at room temperature) Display area Drive system Display colors Number of pixels Pixel arrangement Pixel pitch Module size Weight Contrast ratio Viewing angle (more than the Designed viewing direction Color gamut Response time Luminance Signal system Supply voltage Backlight Power consumption 211.2 (H) × 158.4 (V) mm a-Si TFT active matrix 262,144 colors 800 × 600 pixels RGB vertical stripe 0.264 (H) × 0.264 (V) mm 243.0 (H) × 185.1 (V) × 11.5 max. (D) mm 520 (typ.) 300:1 (typ.) contrast ratio of 10:1) Horizontal : 50° (typ. left side, right side) Vertical : 35° (typ. up side), 45° (typ. down side) • Wider viewing angle with contrast ratio : down side (6 o’clock, normal scan) up side (12 o’clock, reverse scan) • Wider viewing angle without image reversal : up side (12 o’clock, normal scan) down side (6 o’clock, reverse scan) • Optimum grayscale (γ = 2.2) : perpendicular 43 % (typ. center, to NTSC) 15 ms (max.), “white 100%” to “black 10%” 280 cd/m2 (typ.) (Lamp current: I L = 5 mArms per lamp) 6-bit digital signals for each of RGB primary colors, synchronous signals (Hsync, Vsync), dot clock (CLK) 3.3 V [5.0 V] (Logic, LCD driving) Edge light type, two cold cathode fluorescent lamp in a holder, attached inverter • Lamp holder set: Part No.104LHS31 • Recommended invertor: Part No. 104PWBR1 7.0 W (typ. at 3.3 V, with a recommended inverter) Data Sheet EN0493EJ1V0DS00 3 NL8060BC26-17 GENERAL SPECIFICATIONS Item Specification Unit Module size 243.0 ± 0.5 (H) × 185.1 ± 0.5 (V) × 11.5 max. (D) mm Display area 211.2 (H) × 158.4 (V) mm 800 (H) × 600 (V) pixel Dot pitch 0.088 (H) × 0.264 (V) mm Pixel pitch 0.264 (H) × 0.264 (V) mm Number of pixels Pixel arrangement RGB (Red, Green, Blue) vertical stripe Display colors Weight 262,144 color 550 (max.) g ABSOLUTE MAXIMUM RATINGS Parameter Symbol Rating Unit VCC –0.3 to 6.5 V Input voltage VI –0.3 to 6.5 V Lamp voltage VL 2000 Vrms Storage temp. TST –20 to 60 ˚C Operating temp. TOP 0 to 50 ˚C Supply voltage Remarks VI – VCC < 3.0 Ta = 25 ˚C Ta = 25 ˚C Module surface* Humidity < = 95 % relative humidity Ta < = 40 ˚C (No condensation) < = 85 % relative humidity 40 < Ta < = 50 ˚C Absolute humidity shall not exceed Ta = 50 ˚C, 85 % relative humidity level Ta > 50 ˚C * Measured at the panel surface (including self-heat) ELECTRICAL CHARACTERISTICS (1) Logic, LCD driving Ta = 25 ˚C Parameter Symbol Min. Typ. Max. Unit Supply voltage VCC 3.0 (4.75) 3.3 (5.0) 3.6 (5.25) V VCC = 3.3 V (VCC = 5.0 V) Logic input “L” voltage VIL 0 – VCC × 0.3 V CMOS level Logic input “H” voltage VIH VCC × 0.7 – VCC V Supply current ICC – – * 360 (270) 550 (500) mA * Checker flag pattern (in EIAJ ED-2522) 4 Data Sheet EN0493EJ1V0DS00 Remarks VCC = 3.3 V (VCC = 5.0 V) NL8060BC26-17 (2) Backlight Ta = 25 ˚C Parameter Symbol Min. Typ. Max. Unit Remarks Lamp current IL 2.0 5.0 5.5 mArm with one lamp Lamp voltage VL – 510 – Vrms – Lamp turn on voltage VS 840 – – Vrms 1265 – – 50 54 58 Oscillator frequency Ft Ta = 25 ˚C *2 Ta = 0 ˚C *2 kHz *1 *1: Recommended value of "Ft". • Ft is within the specification. and • Ft = 1/4Th × (2n-1) Th: Hsync period n: a natural number (1, 2, 3…) If Ft is out of the recommended value, interference between Ft frequency and Hsync frequency may cause beat on the display. *2: When Vs is less than Min. value, lamp might be not turned on it. *3: Recommended inverter: Part No. 104PWBR1 SUPPLY VOLTAGE SEQUENCE Notes 1. The supply voltage for input signals should be the same as VCC. 2. Turn on the backlight within the LCD operation period. When the backlight 3.0 (4.75 V) 0s<t<35 ms 0s<t<35 ms 3.0 (4.75 V) turns on before LCD operation or the LCD operation turns off before the VCC backlight turns off, the display may momentarily become white. Signals Time VCC - OFF VCC - ON Signals: CLK, Hsync, Vsync, DE, R0-R5, G0-G5, B0-B5 3. When the power is off, please keep whole signals (Hsync, Vsync, CLK, DE, R0-R5, G0-G5, B0-B5) low level or high impedance. 4. Wrong power sequence may damage to the module. 5. The signal should not be down during operation. Even if signal could recover, LCD module can not be operated correctly, the display may be un-uniformity. In case signal is down, VCC should be turned off, and then turn VCC and signal on as above sequence. Data Sheet EN0493EJ1V0DS00 5 NL8060BC26-17 INTERFACE AND CONNECTOR PIN ASSIGNMENT (1) Interface signals, power supply Module side connector CN1 ... DF9-41P-1V (No. 1 to 41) Mating connector DF9-41S-1V Supplier: HIROSE ELECTRIC CO,. LTD. Pin No. Symbol Pin No. Symbol 1 GND Ground Function 22 GND Ground Function 2 CLK Dot clock 23 G3 Green data 3 GND Ground 24 G4 Green data 4 Hsync Horizontal sync. 25 G5 Green data (MSB) 5 Vsync Vertical sync. 26 GND Ground 6 GND Ground 27 GND Ground 7 GND Ground 28 GND Ground 8 GND Ground 29 B0 Blue data (LSB) 9 R0 Red data (LSB) 30 B1 Blue data 10 R1 Red data 31 B2 Blue data 11 R2 Red data 32 GND Ground 12 GND Ground 33 B3 Blue data 13 R3 Red data 34 B4 Blue data 14 R4 Red data 35 B5 Blue data (MSB) 15 R5 Red data (MSB) 36 GND Ground 16 GND Ground 37 DE Data enable signal 17 GND Ground 38 DPS Scan direction select Note 3 18 GND Ground 39 VCC Power supply Note 1 40 VCC Power supply Note 1 MODE Mode select Note 2 19 G0 Green data (LSB) 20 G1 Green data 41 21 G2 Green data LSB : Least Significant Bit MSB : Most Significant Bit Notes 1. VCC: All VCC terminals should be connected to 3.3 V [5.0 V]. 2. MODE: H = Fixed mode L or open = DE mode 3. DPS can change scan direction (normal scan and reverse scan). DPS: Vcc GND or open = normal scan = reverse scan See DISPLAY POSITION about another way for reversible scan. 6 Data Sheet EN0493EJ1V0DS00 NL8060BC26-17 (2) Lamp connector lamp side connector Mating connector CN2 ··· BHR-03VS-1 SM02 (4.0) B-BHS-TB Supplier: J.S.T TRADING COMPANY, LTD. Pin No. Symbol Function 1 VL Low voltage terminal 2 VH High voltage terminal 3 VH High voltage terminal * VH and VL must be connected correctly. If you make a mistake to connect, you will get hurt and the module will break. <Connection of recommended Inverter: 104PWBR1> (NEC) Inverter side connector 1 Mating connector 1 CN1 ··· LZ-5P-SL-SMT LZ-5S-SC3 Supplier: Japan Aviation Electronics Industry Limited (JAE) Pin No. Symbol Function Pin No. Symbol Function 1 VDDB Power supply (12 V) 4 GNDB Backlight ground 2 VDDB Power supply (12 V) 5 BRTHLLuminance select * 3 GNDB Backlight ground * High luminance (100 %) ··· BRTHL = High (+5 V) or open Low luminance (60 %) ··· BRTHL = Low (GNDB level) Inverter side connector 2 Mating connector 2 CN3 ··· IL-Z-3PL-SMTY IL-Z-3S-S125C3 Supplier: Japan Aviation Electronics Industry Limited (JAE) Pin No. Symbol Function 1 BRTC Backlight ON/OFF signal Note 1 2 BRTH Luminance control input Note 2 3 BRTL Luminance control input Note 2 Notes 1. TTL level Backlight ON ··· BRTC = High (+5 V) or Open Backlight OFF ··· BRTC = Low (GNDB level) Data Sheet EN0493EJ1V0DS00 7 NL8060BC26-17 2. <1> A way of luminance control by a variable resistor. This way works when BRTHL (No.5 pin) of CN3 is opened. Mating variable resistor BRTH BRTL Minimum luminance (50 %) : R = 0 Ω Maximum luminance (100 %) : R = 10 KΩ R <2> : 10 KΩ ±5 % A way of luminance control by a voltage This way works when BRTL is opened. The range of input voltage between BRTH and GNDB is as follows. 8 Minimum luminance (50 %) : 2.5 V Maximum luminance (100 %) : <= 1.2 V Data Sheet EN0493EJ1V0DS00 NL8060BC26-17 (3) Connector location Upper side CN2 <Rear view> 1 2 3 4 • CN1 • • Lower side • • • • CN3 Recommended inverter (104PWBR1) • • • 41 40 <Module side Pin arrangement of CN1> 1 1 1 2 2 2 3 3 3 4 <Lamp side Pin arrangement of CN2> <Inverter side Pin arrangement of CN3> 5 <Inverter side Pin arrangement of CN1> Data Sheet EN0493EJ1V0DS00 9 NL8060BC26-17 DISPLAY COLORS vs. INPUT DATA SIGNALS Display colors Data signal (0: Low level, 1: High level) R5 R4 R3 R2 R1 R0 Basic colors Red grayscale Green grayscale B3 B2 B1 B0 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Dark ↑ ↓ Bright | | | | | | | | | 1 1 1 1 1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Dark ↑ ↓ Bright Dark ↑ ↓ Bright Blue | | | | | | | | | 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 1 1 1 0 1 1 1 0 1 | | | 0 0 0 0 0 0 0 0 0 | | | 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 | | | 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 Colors are developed in combination with 6-bit signals (64 steps in grayscale) of each primary red, green, and blue color. This process can result in up to 262144 (64 × 64 × 64) colors. 10 B4 0 0 1 1 0 0 1 1 Black Note B5 Black Blue Red Magenta Green Cyan Yellow White Green Blue grayscale G5 G4 G3 G2 G1 G0 Data Sheet EN0493EJ1V0DS00 NL8060BC26-17 INPUT SIGNAL TIMING (1) Input signal specifications Parameter CLK Symbol Min. Typ. Max. Unit 1/tC 34.0 38.362 40.0 MHz tch/tC 0.4 0.5 0.6 – – Rise, fall tcrf – – 10 ns – Period th 24.3 26.693 – µs 37.468 kHz (typ.) – 1024 – CLK Frequency Duty Hsync Display period thd Front-porch thf Pulse width Back-porch 800 thp thb 24 – CLK Fixed mode 4 24 – CLK DE mode 2 72 127 CLK Fixed mode 2 72 – CLK DE mode 2 128 198 CLK Fixed mode 2 128 – CLK DE mode CLK Fixed mode DE mode 200 15 200 – CLK 10 – – ns – Hsync-CLK timing thcs 8 – – ns – Hsync-Vsync timing thv 1 – – CLK – Vsync-Hsync timing tvs 15 – – ns – Rise, fall thrf – – 10 ns – tv 16.1 16.683 17.2 ms – 625 – H Display period tvd Front-porch tvf Back-porch 600 tvp tvb 59.94 Hz (typ.) H – 1 – H Fixed mode – 1 – H DE mode 1 2 23 H Fixed mode 1 2 – H DE mode 1 22 23 H Fixed mode 1 22 – H DE mode H Fixed mode DE mode tvp + tvb * – thch Pulse width DE CLK CLK-Hsync timing Period DATA R0 - R5 G0 - G5 B0 - B5 26.067 ns (TYP.) – thp + thb Vsync Remarks 24 2 24 254 H Rise, fall tvrf – – 10 ns – CLK-DATA timing tds 8 – – ns – DATA-CLK timing tdh 12 – – ns – Rise, fall tdrf – – 10 ns – DE-CLK timing tes 8 – – ns – CLK-DE timing teh 12 – – ns Rise, fall terf – – 10 ns All of parameters should be kept in the specified range. Data Sheet EN0493EJ1V0DS00 11 NL8060BC26-17 (2) Definition of input signal timing <Vertical> tv tvp Vsync tvf tvb Display period (note) tvd DE <Horizontal> th thp Hsync thf thb Display period (note) thd DE Note 12 These do not exist as signals. Data Sheet EN0493EJ1V0DS00 NL8060BC26-17 (3) Input signal timing chart tC tch CLK 0.7 VCC 0.5 VCC 0.3 VCC tcrf tcrf tds DATA tdh INVALID INVALID (R0-R5) 0.7 VCC (G0-G5) 0.5 VCC (B0-B5) 0.3 VCC tdrf teh DE tdrf tes terf 0.5 VCC thch Hsync tes 0.7 VCC 0.5 VCC 0.3 VCC terf CLK teh thcs 0.7 VCC 0.5 VCC 0.3 VCC thrf Hsync 0.5 VCC thv Vsync ths 0.7 VCC 0.5 VCC 0.3 VCC tvrf Data Sheet EN0493EJ1V0DS00 13 NL8060BC26-17 a) Fixed timing mode Vsync 1H (min.) 1H (min.) 1H 24H (fixed) 600H (fixed) 1H Hsync 23 1 2 3 0 623 624 24 Hsync 24 25 623 624 0 R0 - R5 G0 - G5 B0 - B5 D (X, 0) D (X, Y) D (X, 598) D (X, 599) INVALID INVALID (Note: X = 0 to 799) Hsync R0 - R5 G0 - G5 B0 - B5 D (0, Y) D (1, Y) INVALID D (X, Y) D (798, Y) D (799, Y) INVALID Hsync 1CLK 2CLK (min.) 2CLK (min.) 200CLK (fixed) 800CLK (fixed) 24CLK CLK 1 2 200 201 1000 1001 1023 R0 - R5 G0 - G5 B0 - B5 INVALID D (0, Y) D (1, Y) D (799, Y) INVALID (Note: Y = 0 to 599) 14 Data Sheet EN0493EJ1V0DS00 0 NL8060BC26-17 b) DE mode Vsync 1H tvp tvb tvf 600H (fixed) Hsync 0 1 0 1 2 DE R0 - R5 G0 - G5 B0 - B5 D (X, 0) D (X, Y) D (X, 599) INVALID INVALID (Note: X = 0 to 799) DE R0 - R5 G0 - G5 B0 - B5 D (0, Y) D (1, Y) INVALID D (X, Y) D (798, Y) D (799, Y) INVALID Hsync 1CLK thp thb 800CLK (fixed) thf CLK 0 1 2 0 1 DE R0 - R5 G0 - G5 B0 - B5 INVALID D (0, Y) D (1, Y) D (799, Y) INVALID (Note: Y = 0 to 599) Data Sheet EN0493EJ1V0DS00 15 NL8060BC26-17 DISPLAY POSITION D (799, 1) D (0, 1) D (1, 1) --------- D (X, 1) --------- D (798, 1) D (799, 1) --- --------- D (X, Y) ----------------- --- --- --------- D (798, Y) D (799, Y) --- --------- --- D (1, Y) --- D (0, Y) --- --------- --- D (798, 1) --- --------- --- D (X, 1) --- --------- --- D (1, 1) --- D (0, 1) --- Normal scan (DPS = "Vcc") D (0, 598) D (1, 598) --------- D (X, 598) --------- D (798, 598) D (799, 598) D (0, 599) D (1, 599) --------- D (X, 599) --------- D (798, 599) D (799, 599) Reverse scan (DPS = "GND" or "Open") D (0,599) D (799,598) D (798,598) --------- D (X, 598) --------- D (1,598) D (0,598) --------- D (1, Y) --------- --- --------- D (0, Y) --- D (X, Y) --- --- --------- --- --------- --- --D (798, Y) --- D (799, Y) --------- --- D (1,599) --- --------- --- D (X, 599) --- --------- --- D (798,599) --- D (799,599) D (799, 1) D (798, 1) --------- D (X, 1) --------- D (1, 1) D (0, 1) D (799, 0) D (798, 0) --------- D (X, 0) --------- D (1, 0) D (0, 0) * Below drawings show relations between the scan direction and the viewing direction. Normal scan D (0, 0) C N 1 D (0, 599) Reverse scan C N 2 D (799, 0) D (0, 0) D (799, 0) D (0, 599) D (799, 599) D (799, 599) C N 2 16 Data Sheet EN0493EJ1V0DS00 C N 1 NL8060BC26-17 OPTICAL CHARACTERISTICS Ta = 25°C Note 1 Item Contrast ratio Symbols CR Luminance Lu nax. Luminance uniformity – Conditions Note 2 Note 2 Min. Typ. Max. Unit Remarks 150 300 – – Note 3 Note 4 200 280 – cd/m2 – – 1.4 – Note 5 Min. Typ. Max. Unit Remarks Note 6 max./min. Reference data Item Response time Color gamut Viewing Horizontal angle range Vertical Symbols Conditions t on White to black 100% → 10% – 15 50 ms t off Black to white 0% → 90% – 65 80 ms C at center, to NTSC – 43 – % – θx+ CR > 10, θy = ±0° 45 50 – deg. Note 7 θx– CR > 10, θy = ±0° 45 50 – deg. θy+ CR > 10, θy = ±0° 30 35 – deg. θy– CR > 10, θy = ±0° 40 45 – deg. Notes 1. VCC = 3.3 V, IL = 5.0 mA rms, DPS = High at normal scan with recommended inverter. 2. Viewing angle: θx = ±0°, θy = ±0°, At center. 3. The contrast ratio is calculated by using the following formula. Contrast ratio (CR) = Luminance with all pixels in "white" Luminance with all pixels in "black" The luminance is measured in darkroom. 4. The luminance is measured after 20 minutes from the module works, with all pixels in "white". Typical value is measured after luminance saturation. The luminance is measured in darkroom. 1° Photodetector (TOPCON BM-5A) 50 cm LCD MODULE Data Sheet EN0493EJ1V0DS00 17 NL8060BC26-17 5. The luminance uniformity is calculated by using following formula. Luminance uniformity = Maximum luminance Minimum luminance The luminance is measured at near the five points shown below. Column (160) (320) (480) Line 1 4 (120) 3 (240) 2 5 (360) 6. Definition of response time is as follows. Photodetector output signal is measured when the Luminance changes "white" to "black" or "black" to "white". 100% Display color White Luminance range 90% Black 10% 0% ton toff Time 7. Definitions of viewing angle are as follows. Perpendicular 12 o’clock θ x– Left θ y+ θ x+ Upper θ y– Lower Right 18 Data Sheet EN0493EJ1V0DS00 NL8060BC26-17 RELIABILITY TEST SPECIFICATIONS Test items Test conditions High temperature/humidity 50 ± 2°C, 85% relative humidity operation 240 hours Judgement Note 1 Display data is black. Heat cycle (operation) <1> 0°C ± 3°C … 1 hour Note 1 55°C ± 3°C … 1 hour <2> 50 cycles, 4 hours/cycle <3> Display data is black. Thermal shock (non-operation) <1> –20°C ± 3°C … 30 minutes Note 1 60°C ± 3°C … 30 minutes <2> 100 cycles <3> Temperature transition time within 5 minutes Vibration (non-operation) <1> 5 - 100 Hz, 19.6 m/s2 (2G) Note 1 1 minute/cycle, Note 2 X, Y, Z direction <2> 120 times each direction Mechanical shock (nonoperation) <1> 539 m/s2 (55G), 11 ms Note 1 X, Y, Z direction Note 2 <2> 5 times each direction ESD (operation) 150 pF, 150 Ω, ±10 kV 9 places on a panel Note 1 Note 3 10 times each place at one-second intervals Dust (operation) 15 kinds of dust (JIS Z 8901) Note 1 Hourly 15 seconds stir, 8 times repeat Notes 1. Display function is checked by the same condition as LCD module out-going inspection. 2. Physical damage. 3. Discharge points are shown as follows. Data Sheet EN0493EJ1V0DS00 19 NL8060BC26-17 GENERAL CAUTIONS Next figures and sentence are very important, please understand these contents as follows. This figure is a mark that you will get hurt and/or the module will have damages when you make CAUTION a mistake to operate. This figure is a mark that you will get an electric shock when you make a mistake to operate. This figure is a mark that you will get hurt when you make a mistake to operate CAUTION Do not touch an inverter ···on which is stuck a caution label··· while the LCD module is under the operation, because of dangerous high voltage. (1) Caution when taking out the module <1> Pick the pouch only, when taking out the module from a carrier box. (2) Cautions for handling the module <1> As the electrostatic discharges may break the LCD module, handle the LCD module with care against electrostatic discharges. <2> As the LCD panel and backlight element are made from fragile glass material, impulse and pressure to the LCD module should be avoided. <3> As the surface of polarizer is very soft and easily scratched, use a soft dry cloth without chemicals for cleaning. <4> Do not pull the interface connectors in or out while the LCD module is operating. <5> Put the module display side down on a flat horizontal plane. <6> Handle connectors and cables with care. <7> When the module is operating, do not lose CLK, Hsync, or Vsync signal. If any one of these signals is lost, the LCD panel would be damaged. <8> <9> The torque for mounting screw should never exceed 0.294 N·m (3 kgf·cm). Don’t push or rub the surface of LCD module please. If you do, the scratches or the marks like rubbing marks may be left on the surface of the module. (3) Cautions for the atmosphere <1> Dew drop atmosphere must be avoided. <2> Do not store and/or operate the LCD module in high temperature and/or high humidity atmosphere. Storage in an electro-conductive polymer packing pouch and under relatively low temperature atmosphere is recommended. <3> This module uses cold cathod fluorescent lamps. Therefore, the life time of lamp becomes short conspicuously at low temperature. <4> 20 Do not operate the LCD module in high magnetic field. Data Sheet EN0493EJ1V0DS00 NL8060BC26-17 (4) Caution for the module characteristics <1> Do not apply any fixed patterns data signal to the LCD module at product aging. Applying fixed pattern for a long time may cause image sticking. <2> This module has the retardation film which may cause the variation of the color hue in the different viewing angles. The ununiformity may appear on the screen under the high temperature operation. <3> The light vertical stripe may be observed depending on the display pattern. This is not defects or malfunctions. <4> The noise from the inverter circuit may be observed in the luminance control mode. This is not defects or malfunctions. (5) Other cautions <1> Do not disassemble and/or reassemble LCD module. <2> Do not readjust variable resistors nor switches etc. <3> When returning the module for repair etc., Please pack the module properly to avoid any damages. We recommend the original shipping packages. <4> In case that the scan comverter is used to convert VGA signal to NTSC, it is recommended using the framememory type, not the line-memory. Liquid Crystal Display has the following specific characteristics. There are not defects nor malfunctions. The display condition of the LCD module may be affected by the ambient temperature. The LCD module uses cold cathode tube for backlighting. Optical characteristics, like luminance or uniformity, will be changed by the progress in time. Uneven brightness and/or small spots may be observed depending on different display patterns. Data Sheet EN0493EJ1V0DS00 21 11.5 MAX 22 OUTLINE DRAWING FRONT SIDE (Unit in mm) 243 ±0.5 235 ±0.3 (4.8) (215.4) (BEZEL OPENING) 7.2 ±0.3 11.5 MAX 5.25 ±0.3 (211.2) (ACTIVE AREA) 11.5 MAX (9.3) (2.9) (12.9) (4) (5.7) 2.75 ±0.2 (2.8) (3.9) (8.1) (5.1) (29.4) 146.6 ±0.3 (4.7) 17 ±0.3 (6.3) (3.15) 166.6 ±0.3 185.1 ±0.5 (ACTIVE AREA) 5.25 ±0.3 (88.3) (158.4) (ACTIVE AREA) 132.6 ±0.3 (MODULE CENTER) 2.75 ±0.2 (161.8) (BEZEL OPENING) (1.8) (88.3) Data Sheet EN0493EJ1V0DS00 2-R1.75 5.25 ±0.3 (3.7) (4.7) 4-CPIMS × M2 × L4 CN1 DF9C-41P-1 V 2- φ 3.5 2.75 ±0.2 (5.1) (8.1) (2.8) (4) * The torque to mounting screw should never exceed 0.294 N·m (3Kgf·cm). * The valuse in parentheses are reference. (2.9) (3.9) NL8060BC26-17 8.25 TYP 8.25 TYP 8.25 TYP 5.25 ±0.3 (5.7) 2.75 ±0.2 OUTLINE DRAWING REAR SIDE (Unit in mm) BHR-03VS-1 (JST) 1PIN: COLD, 2·3PIN: HOT (4.5) (3.4) 60 ±10 (2.4) (5) (5) (5.6) (5.3) NION VOLTEGE CAUTION RISK OF ELECTRIC SHOCK. DISCONNECT THE ELECTRIC POWER BEFORE SERVICE. (8) (5) (6.8) (16) ∗∗∗−∗ THE TFT COLOR LCD PANEL CONTAINS COLD CATHODE FLOURESCENT LAMPS. PLEASE FOLLOW LOCAL ORDINANCES OR REGULATIONS FOR ITS DISPOSAL (5) (5) Pal No. 4.0 ±0.5 (22) Name 104DLMS 88.9 ±0.5 Data Sheet EN0493EJ1V0DS00 2.3 ±0.5 (5) DF9C-41P-1 V (5) (5) (3.4) (4.5) MADE IN JAPAN (6.6) (2.4) (5.3) 23 (3.4) ES2228423 K2000A483324 NL8060BC26-17 (6.8) NL8060BC26-17 K2 0 0 0 A 4 8 3 3 2 4 NL8060BC26-17 No part of this document may be copied in any form or by any means without the prior written consent of NEC Corporation. NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or of others. While NEC Corporation has been making continuous effort to enhance the reliability of its Electronic Components, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property arising from a defect in an NEC Electronic Components, customers must incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and anti-failure features. NEC devices are classified into the following three quanlity grades: "Standard", "Special", and "Specific". The Specific quanlity grade applies only to devices developed based on a customer designated "quality assurance program" for a specific application. The recommended applications of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device before using it in a particular application. Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots. Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support) Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support system or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those speci fied for Standard quality grade, they should contact an NEC sales representative in advance. Anti-radioactive design is not implemented in this product.