Lighting | Imaging | Telecom p Pyroelectric Infrared Detectors Single Element Detector LHi 807, 807TC Thermally compensated option Designed for Gas Analysis applications The LHi 807 pyroelectric infrared-detector series is specially designed for gas analysis and monitorring applications . It includes pyroelectric element with FET in source follower connection and is avaliable with a second element shut from radiation for thermal compensation. This detector is encapsulated into TO-5 housing with an infrared window which acts as specific filter. There are many filters available for the selected spectral bandwidths, refer to catalogue envelope for the details. Parameters min typical Element size R esponsivity Noise 100°C, 10 Hz 807TC 250 320 V /W 100°C, 10 Hz 807 600 1200 nV RMS 25°C , 10Hz 807TC 300 600 nVRMS 25°C , 10Hz 1,5 V RS =47kW , 25°C W Ö Hz 1Hz Bw, 100°C, 1 Hz 0,2 Right for modification reserved / WS /, 27.12.2000 9,4x10-10 24x10-10 6x10 16x10 2 Field of View, horizontal vertical cm Ö Hz/W 1Hz Bw, 100°C, 1 Hz 7 10 kW RS =47kW , 25°C 15 V RS =47kW , 25°C 135° unobstructed 120° unobstructed Operating Temp. -40 85 °C non permanent S torage Temperature -40 85 °C non permanent LHi 807TC 100 R [kV/W] 10 1 10 f [Hz] Dimensions in mm Frequency Response Europe: PerkinElmer Optoelectronics GmbH Wenzel Jaksch Str 31 Wiesbaden / Germany Phone +49(0)611 492 0 Fax +49(0)611 492 170 7 5 Operating Voltage 1 mm2 V /W Output Impedance 0,1 1,5 x 1,5 condition 640 D* 0,1 0,01 units 500 NEP LHi 807 ma x 807 Offset Voltage Field of View 807/ 8 0 7 TC LHi USA: PerkinElmer Optoelectronics 2175 Mission Colledge Blvd Santa Clara, CA 95054 Phone +408 565 0830 Fax +408 565 0703 Asia: PerkinElmer Optoelectronics 47, Ayer Rajah Crescent #06-12 Singapore 139947 Phone +65 775 2022 Fax +65 775 1008 www.perkinelmer.com/opto D A T A S H E E T Element size 1,5x1,5