DIODE MODULE DD60KB UL;E76102 (M) Power Diode Module DD60KB Seriess are designed for various rectifier circuits. DD60KB has two diode chips connected in series and the mounting base is electrically isolated from elements for simple heatsink construction. Wide voltage rating up to, 1600V is available for various input voltages. ● Isolated mounting base ● Two elements in a package for simple (single and three phase) bridge connections ● Highly reliable glass passivated chips ● High surge current capability 93.5max 16.5 1 23 23 3-M5 21 30max (Applications) ● Various rectifiers, Battery chargers, DC motor drives 2-φ6.5 2 13 26max 80 3 Unit:㎜ ■Maximum Ratings Symbol (Tj=25℃ unless otherwise specified) Ratings Item DD60KB80 DD60KB160 Unit VRRM Repetitive Peak Reverse Voltage 800 1600 V VRSM Non-Repetitive Peak Reverse Voltage 960 1700 V Symbol Item IF(AV) Conditions Average Forward Current Single phase, half wave, 180℃ conduction, Tc=110℃ IF(RMS) R.M.S. Forward Current Single phase, half wave, 180℃ conduction, Tc=110℃ IFSM Surge Forward Current 1 /2cycle, It It Value for one cycle of surge current Tj Operating Junction Temperature 2 2 Tstg Storage Temperature VISO Isolation Breakdown Voltage(R.M.S.) Mounting Torque 50/60HZ, peak value, non-repetitive A.C. 1minute Ratings Unit 60 A 95 A A 1100/1200 6000 A2S −40 to +150 ℃ −40 to +125 ℃ 2500 V Mounting(M6) Recommended Value 2.5-3.9(25-40) 4.7(48) Terminal(M5) Recommended Value 1.5-2.5(15-25) 2.7(28) N・m (㎏f・B) 170 g Ratings Unit Mass Typical Value ■Electrical Characteristics Symbol Item IRRM Repetitive Peak Reverse Current, max. at VRRM Single phase, half wave, Tj=150℃ 20 mA VFM Forward Voltage Drop, max. Forward current 180A, Inst measurement 1.35 V Junction to case 0.52 ℃/W Rth(j-c) Thermal Impedance, max. SanRex Conditions ® 50 Seaview Blvd. Port Washington, NY 11050-4618 PH.(516)625-1313 FAX(516)625-8845 E-mail: [email protected] DD60KB 3 10 Maximum Forward Characteristics 100 Power Dissipation Pav(W) Forward Current(A) 5 2 102 5 2 101 5 2 100 0. 6 0. 8 1. 0 1. 2 1. 4 1. 6 1. 8 Average Forward Current vs. Power Dissipation D.C. 80 Single Phase Three Phase 60 40 Per one element 20 0 0 2. 0 20 150 Average Forward Current vs. Allowable Case Temperature 140 130 120 110 Three Phase 100 D.C. Single Phase 90 0 0 10 20 30 40 50 60 70 80 90 100 Average Forward Current(A) Transient Thermal Impedance θj-c(℃/W) 80 100 1200 Cycle Surge Forward Current Rating (Non-Repetitive) 1000 Per one element 0. 6 60 40 Average Forward Current(A) Surge Forward Current(A) Allowable Case Temperature Tc(℃) Forward Voltage Drop(V) Per one element Tj=25℃ start 800 60Hz 50Hz 600 400 200 0 1 2 5 10 20 50 100 Time(Cycles) Transient Thermal Impedance Junction to Case 0. 5 0. 4 Per one element 0. 3 0. 2 0. 1 0 10−3 2 SanRex 5 5 10−2 100 2 2 5 5 Time t(sec) 10−1 101 2 5 ® 50 Seaview Blvd. Port Washington, NY 11050-4618 PH.(516)625-1313 FAX(516)625-8845 E-mail: [email protected]