SANYO LA6518

Ordering number: EN 5162
Monolithic Linear IC
LA6518M
2-Channel Power Operational Amplifier
Package Dimensions
Applications
The LA6518M is a 2-output power operational amplifier
developed for use in consumer and industrial equipment.
unit : mm
3097-MFP16FS
[LA6518M]
Features and Functions
. High output current (I max = 0.5 A)
. High gain
. Includes current limiter
. Wide operating voltage range (±2 to ±18 V)
. Single power supply operation possible (4 to 36 V)
. Thermal shutdown function built in
O
Allowable power dissipation, Pd max — W
SANYO : MFP16FS
Pd max — Ta
Independent IC
Ambient temperature, Ta — °C
Specifications
Maximum Ratings at Ta = 25 °C
Parameter
Symbol
Conditions
Ratings
Unit
Maximum supply voltage
VCC/VEE
±18
V
Differential input voltage
VID
30
V
Common-mode input voltage
VIN
±15
V
Allowable power dissipation
Pd max
0.7
W
Operating temperature
Topr
–20 to +75
°C
Storage temperature
Tstg
–55 to +150
°C
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
92995HA(II) No.5162-1/4
LA6518M
Operating Conditions at Ta = 25 °C
Parameter
Recommended supply voltage
Symbol
Conditions
VCC/VEE
Ratings
Unit
±2 to ±16
V
Electrical Characteristics at Ta = 25 °C, VCC/VEE = ±15 V
Parameter
No-load current drain
Input offset voltage
Input offset current
Input bias current
Common-mode input voltage range
Common-mode signal rejection ratio
Maximum output voltage
Voltage gain
Slew rate
Supply voltage rejection ratio
Limit current (built-in type)
. Thermal shutdown function built in.
Symbol
ICC
VIO
IIO
IB
VICM
CMR
VO
VGO
SR
SVR
ISC
Conditions
min
RS % 10 kΩ
RL = 33 Ω
GV = 0, RL = 33 Ω, R = 10 Ω, L = 0.1 µF
−14
65
±11
typ
8
2
10
100
80
±12
85
0.15
30
0.5
max
20
7
100
300
+13
300
Unit
mA
mV
nA
nA
V
dB
V
dB
V/µs
µV/V
A
Block Diagram and Pin Assignment
Thermal shutdown
and
current limiter
Do not use the NC pin.
Top view
No.5162-2/4
LA6518M
Test Circuit
No.5162-3/4
LA6518M
Oscilloscope
short wave
Pulse generator
No products described or contained herein are intended for use in surgical implants, life-support systems, aerospace equipment,
nuclear power control systems, vehicles, disaster/crime-prevention equipment and the like, the failure of which may directly or
indirectly cause injury, death or property loss.
Anyone purchasing any products described or contained herein for an above-mentioned use shall:
1 Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors
and all their officers and employees, jointly and severally, against any and all claims and litigation and all damages, cost and
expenses associated with such use:
2 Not impose any responsibility for any fault or negligence which may be cited in any such claim or litigation on SANYO
ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of their officers and employees jointly or severally.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume
production. SANYO believes information herein is accurate and reliable, but no guarantees are made or implied regarding its use
or any infringements of intellectual property rights or other rights of third parties.
This catalog provides information as of September, 1995. Specifications and information herein are subject to change without notice.
No.5162-4/4