MICREL SY100EPT22VKC

Micrel, Inc.
ECL Pro™
SY100EPT22V
3.3V/5V DUAL
LVTTL/LVCMOS-to-DIFFERENTIAL
LVPECL TRANSLATOR
ECL Pro™
SY100EPT22V
FEATURES
■
■
■
■
■
■
■
■
■
3.3V and 5V power supply option
300ps typical propagation delay
Differential LVPECL outputs
ICC Max 25mA
PNP LVTTL inputs for minimal loading
Flow-through pinouts
Q outputs will default HIGH with inputs open
Max. frequency range 800MHz
Available in 8-pin MSOP and SOIC package
ECL Pro™
DESCRIPTION
The SY100EPT22V is a dual TTL/CMOS to differential
PECL translator. Capable of running from a 3.3 or 5V
supply, the part can be used in either LVTTL/LVCMOS/
LVPECL or TTL/CMOS/PECL systems.
The device only requires a single positive supply of
3.3V or 5V - no negative supply is required.
The tiny 8-pin MSOP package and the low skew, dual
gate design of the EPT22V makes it ideal for those
applications where space, performance, and low power
are at a premium.
PIN NAMES
Pin
Function
Q0, /Q0, Q1, /Q1
Differential LVPECL Outputs
D0, D1
LVTTL Inputs
VCC
Positive Supply
GND
Ground
ECL Pro is a trademark of Micrel, Inc.
M9999-052108
[email protected] or (408) 955-1690
Rev.: F
1
Amendment: /0
Issue Date: May 2008
ECL Pro™
SY100EPT22V
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
Q0 1
8 VCC
/Q0 2
7 D0
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY100EPT22VZC
Z8-1
Commercial
XEP22V
Sn-Pb
Q1 3
6 D1
SY100EPT22VZCTR(2)
Z8-1
Commercial
XEP22V
Sn-Pb
/Q1 4
5 GND
SY100EPT22VKC
K8-1
Commercial
XP22
Sn-Pb
SY100EPT22VKCTR(2)
K8-1
Commercial
XP22
Sn-Pb
SY100EPT22VKI
K8-1
Industrial
XP22
Sn-Pb
SY100EPT22VKITR(2)
K8-1
Industrial
XP22
Sn-Pb
SY100EPT22VZI
Z8-1
Industrial
XEP22V
Sn-Pb
SY100EPT22VZITR(2)
Z8-1
Industrial
XEP22V
Sn-Pb
SY100EPT22VZG(3)
Z8-1
Industrial
XEP22V with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY100EPT22VZGTR(2, 3)
Z8-1
Industrial
XEP22V with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY100EPT22VKG(3)
K8-1
Industrial
XP22 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
SY100EPT22VKGTR(2, 3)
K8-1
Industrial
XP22 with
Pb-Free bar-line indicator
Pb-Free
NiPdAu
LVPECL
LVTTL
Available in 8-pin SOIC and
8-pin MSOP
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-052108
[email protected] or (408) 955-1690
2
ECL Pro™
SY100EPT22V
Micrel, Inc.
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Paramter
TRUTH TABLE
Value
Unit
D
Q
/Q
VCC
Power Supply Voltage
–0.5 to +7.0
V
H
H
L
VI
TTL Input Voltage
–0.5 to VCC
V
L
L
H
II
TTL Input Current
–30 to +5.0
mA
Open
H
L
IO
PECL Output Current
mA
— Continuous
50
— Surge
100
+260
°C
Storage Temperature
–65 to +150
°C
Operating Temperature
–40 to +85
°C
TLEAD
Lead Temperature
(Soldering, 20sec.)
Tstore
TA
Notes:
1. Permanent device damage may occur if absolute maximum ratings are
exceeded. This is a stress rating only and functional operation is not
implied at conditions other than those detailed in the operational
sections of this data sheet. Exposure to absolute maximum ratlng
conditions for extended periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS(1)
VCC = +3.3V ±5% or +5.0V ±5%
TA = –40°C
Symbol
ICC
Parameter
Power Supply Current
TA = 0°C
TA = +25°C TA = +85°C
Min. Max. Min. Max. Min. Max. Min. Max. Unit
—
25
—
25
—
25
—
25
Condition
mA
—
Notes:
1. Parametric values specified at:
3 volt Power Supply Range
100EPT22V Series:
+3.0V to +3.8V.
5 volt Power Supply Range
100EPT22V Series:
+4.2V to +5.5V.
TTL DC ELECTRICAL CHARACTERISTICS(1)
VCC = +3.3V ±5% or +5.0V ±5%
TA = –40°C
Symbol
Parameter
Min.
TA = 0°C
Max.
Min.
TA = +25°C
TA = +85°C
Max.
Min.
Max.
Min.
Max.
Unit
Condition
VIH
Input HIGH Voltage
2.0
—
2.0
—
2.0
—
2.0
—
V
—
VIL
Input LOW Voltage
—
0.8
—
0.8
—
0.8
—
0.8
V
—
IIH
Input HIGH Current
—
—
20
100
—
—
20
100
—
—
20
100
—
—
20
100
µA
VIN = 2.7V
VIN = VCC
IIL
Input LOW Current
—
–0.2
—
–0.2
—
–0.2
—
–0.2
mA
VIN = 0.5V
VIK
Input Clamp Voltage
—
–1.2
—
–1.2
—
–1.2
—
–1.2
V
IIN = –18mA
Notes:
1. Parametric values specified at:
M9999-052108
[email protected] or (408) 955-1690
3 volt Power Supply Range
100EPT22V Series:
+3.0V to +3.8V.
5 volt Power Supply Range
100EPT22V Series:
+4.2V to +5.5V.
3
ECL Pro™
SY100EPT22V
Micrel, Inc.
PECL DC ELECTRICAL CHARACTERISTICS(1)
VCC = +3.3V ±5% or +5.0V ±5%
TA = –40°C
Symbol
VOH
VOL
Parameter
TA = 0°C
Min.
Typ.
Max.
Min.
Typ.
100EPT
2220
—
2420
2275
—
Output LOW Voltage(2)
100EPT
1470
—
1750
1490
—
Output HIGH
TA = +25°C
Max.
Min.
TA = +85°C
Typ.
Max.
Min.
Typ.
Max.
2420 2275
—
2420
2275
—
2420
1680 1490
—
1680
1490
—
1680
Voltage(2)
Unit
mV
mV
Notes:
1. Parametric values specified at:
3 volt Power Supply Range
100EPT22V Series: +3.0V to +3.8V.
5 volt Power Supply Range
100EPT22V Series: +4.2V to +5.5V.
2. These values are for VCC = 3.3V. Level Specifications will vary 1:1 with VCC.
AC ELECTRICAL CHARACTERISTICS(1, 2)
VCC = +3.3V ±5% or +5.0V ±5%
TA = –40°C
Symbol
Parameter
tPD
Propagation Delay to Output D,
ENECL/ENTTL
tskpp
Part-to-Part Skew(2)
Skew(2, 3)
tskew
Within-Device
tr
tf
Output Rise/Fall Time
20% to 80%
fMAX
Maximum Toggle Frequency
TA = 0°C
TA = +25°C TA = +85°C
Min. Max. Min. Max. Min. Max.
Min. Max.
Unit
Condition
100
600
100
600
100
600
100
600
ps
50Ω to VCC – 2.0V
—
500
—
500
—
500
—
500
ps
50Ω to VCC – 2.0V
—
100
—
100
—
100
—
100
ps
50Ω to VCC – 2.0V
200
500
200
500
200
500
200
500
ps
50Ω to VCC – 2.0V
—
800
—
800
—
800
—
800
MHz
50Ω to VCC – 2.0V
Notes:
1. Parametric values specified at:
3 volt Power Supply Range
100EPT22V Series: +3.0V to +3.8V.
5 volt Power Supply Range
100EPT22V Series: +4.2V to +5.5V.
2. Guaranteed, but not tested.
3. Same transition @common VCC levels.
M9999-052108
[email protected] or (408) 955-1690
4
ECL Pro™
SY100EPT22V
Micrel, Inc.
8-PIN PLASTIC SOIC (Z8-1)
Rev. 03
M9999-052108
[email protected] or (408) 955-1690
5
ECL Pro™
SY100EPT22V
Micrel, Inc.
8-PIN MSOP (K8-1)
Rev. 01
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2005 Micrel, Incorporated.
M9999-052108
[email protected] or (408) 955-1690
6