FEATURES
DESCRIPTION
•
•
•
The X9241 integrates four nonvolatile E2POT digitally
controlled potentiometers on a monolithic CMOS microcircuit.
•
•
•
•
•
•
•
E2POTs
Four
in One Package
Two-Wire Serial Interface
Register Oriented Format
—Directly Write Wiper Position
—Read Wiper Position
—Store as Many as Four Positions per Pot
Instruction Format
—Quick Transfer of Register Contents to
Resistor Array
—Cascade Resistor Arrays
Low Power CMOS
Direct Write Cell
—Endurance - 100,000 Data Changes per Register
—Register Data Retention - 100 years
16 Bytes of E2PROM memory
3 Resistor Array Values
—2KΩ to 50KΩ Mask Programmable
—Cascadable For Values of 500Ω to 200KΩ
Resolution: 64 Taps each Pot
20-Lead Plastic DIP, 20-Lead TSSOP and
20-Lead SOIC Packages
The X9241 contains four resistor arrays, each composed of 63 resistive elements. Between each element
and at either end are tap points accessible to the wiper
elements. The position of the wiper element on the array
is controlled by the user through the two-wire serial bus
interface.
Each resistor array has associated with it a wiper counter
register and four 8-bit data registers that can be directly
written and read by the user. The contents of the wiper
counter register control the position of the wiper on the
resistor array.
The data register may be read or written by the user. The
contents of the data registers can be transferred to the
wiper counter register to position the wiper. The current
wiper position can be transferred to any one of its
associated data registers.
The arrays may be cascaded to form resistive elements
with 127, 190 or 253 taps.
FUNCTIONAL DIAGRAM
R0 R1
WIPER
COUNTER
REGISTER
(WCR)
R2 R3
SCL
SDA
A0
A1
A2
A3
INTERFACE
AND
CONTROL
CIRCUITRY
VH0
R0 R1
VL0
VW0
R2 R3
VH2
WIPER RESISTOR
COUNTER ARRAY
REGISTER
POT 2
(WCR)
VL2
VW2
8
DATA
R0 R1
R2 R3
VH1
WIPER
COUNTER RESISTOR
ARRAY
REGISTER
POT 1
(WCR)
VL1
VW1
R0 R1
R2 R3
VH3
WIPER
RESISTOR
COUNTER
ARRAY
REGISTER
POT 3
(WCR)
VL3
VW3
3864 ILL F07.1
© Xicor, Inc. 1994, 1995, 1996 Patents Pending
3864-2.7 7/1/96 T0/C3/D3 NS
1
Characteristics subject to change without notice
X9241
PIN DESCRIPTIONS
PIN NAMES
Symbol
SCL
SDA
A0–A3
VH0–VH3, VL0–VL3
Host Interface Pins
Serial Clock (SCL)
The SCL input is used to clock data into and out of the
X9241.
Serial Data (SDA)
VW0–VW3
SDA is a bidirectional pin used to transfer data into and
out of the device. It is an open drain output and may be
wire-ORed with any number of open drain or open
collector outputs. An open drain output requires the use
of a pull-up resistor. For selecting typical values, refer
to the guidelines for calculating typical values on the
bus pull-up resistors graph.
3864 PGM T01
PRINCIPLES OF OPERATION
The X9241 is a highly integrated microcircuit incorporating four resistor arrays, their associated registers and
counters and the serial interface logic providing direct
communication between the host and the E2POT potentiometers.
Address
The Address inputs are used to set the least significant
4 bits of the 8-bit slave address. A match in the slave
address serial data stream must be made with the
Address input in order to initiate communication with the
X9241.
Serial Interface
The X9241 supports a bidirectional bus oriented protocol. The protocol defines any device that sends data
onto the bus as a transmitter and the receiving device as
the receiver. The device controlling the transfer is a
master and the device being controlled is the slave. The
master will always initiate data transfers and provide the
clock for both transmit and receive operations. Therefore, the X9241 will be considered a slave device in all
applications.
Potentiometer Pins
VH (VH0 – VH3), VL (VL0 – VL3)
The VH and VL inputs are equivalent to the terminal
connections on either end of a mechanical potentiometer.
VW (VW0 – VW3)
Clock and Data Conventions
The wiper outputs are equivalent to the wiper output of
a mechanical potentiometer.
Data states on the SDA line can change only during
SCL LOW periods (tLOW). SDA state changes during
SCL HIGH are reserved for indicating start and stop
conditions.
PIN CONFIGURATION
Start Condition
DIP/SOIC/TSSOP
VW0
1
20
VCC
VL0
2
19
VW3
VH0
3
18
VL3
A0
4
17
VH3
A2
5
16
A1
VW1
6
15
A3
VL1
7
14
SCL
VH1
8
13
VW2
SDA
9
12
VL2
VSS
10
11
VH2
X9241
Description
Serial Clock
Serial Data
Address
Potentiometers
(terminal equivalent)
Potentiometers
(wiper equivalent)
All commands to the X9241 are preceded by the start
condition, which is a HIGH to LOW transition of SDA
while SCL is HIGH (tHIGH). The X9241 continuously
monitors the SDA and SCL lines for the start condition
and will not respond to any command until this condition
is met.
Stop Condition
All communications must be terminated by a stop condition, which is a LOW to HIGH transition of SDA while
SCL is HIGH.
3864 ILL F01A.2
2
X9241
Acknowledge
The next four bits of the slave address are the device
address. The physical device address is defined by the
state of the A0-A3 inputs. The X9241 compares the
serial data stream with the address input state; a successful compare of all four address bits is required for
the X9241 to respond with an acknowledge.
Acknowledge is a software convention used to provide
a positive handshake between the master and slave
devices on the bus to indicate the successful receipt of
data. The transmitting device, either the master or the
slave, will release the SDA bus after transmitting eight
bits. The master generates a ninth clock cycle and
during this period the receiver pulls the SDA line LOW to
acknowledge that it successfully received the eight bits
of data. See Figure 7.
Acknowledge Polling
The disabling of the inputs, during the internal nonvolatile write operation, can be used to take advantage
of the typical 5ms E2PROM write cycle time. Once the
stop condition is issued to indicate the end of the
nonvolatile write command the X9241 initiates the internal write cycle. ACK polling can be initiated immediately.
This involves issuing the start condition followed by the
device slave address. If the X9241 is still busy with the
write operation no ACK will be returned. If the X9241 has
completed the write operation an ACK will be returned
and the master can then proceed with the next
operation.
The X9241 will respond with an acknowledge after
recognition of a start condition and its slave address and
once again after successful receipt of the command
byte. If the command is followed by a data byte the
X9241 will respond with a final acknowledge.
Array Description
The X9241 is comprised of four resistor arrays. Each
array contains 63 discrete resistive segments that are
connected in series. The physical ends of each array are
equivalent to the fixed terminals of a mechanical potentiometer (VH and VL inputs).
Flow 1. ACK Polling Sequence
NONVOLATILE WRITE
COMMAND COMPLETED
ENTER ACK POLLING
At both ends of each array and between each resistor
segment is a FET switch connected to the wiper (VW)
output. Within each individual array only one switch may
be turned on at a time. These switches are controlled by
the Wiper Counter Register (WCR). The six least significant bits of the WCR are decoded to select, and enable,
one of sixty-four switches.
ISSUE
START
The WCR may be written directly, or it can be changed
by transferring the contents of one of four associated
data registers into the WCR. These data registers and
the WCR can be read and written by the host system.
ISSUE SLAVE
ADDRESS
ACK
RETURNED?
Device Addressing
Following a start condition the master must output the
address of the slave it is accessing. The most significant
four bits of the slave address are the device type
identifier (refer to Figure 1 below). For the X9241 this is
fixed as 0101[B].
FURTHER
OPERATION?
0
1
NO
YES
DEVICE TYPE
IDENTIFIER
1
NO
YES
Figure 1. Slave Address
0
ISSUE STOP
A3
A2
A1
ISSUE
INSTRUCTION
ISSUE STOP
PROCEED
PROCEED
A0
DEVICE ADDRESS
3864 ILL F01
3864 FHD F08
3
X9241
Instruction Structure
action will be delayed tSTPWV. A transfer from WCR
current wiper position, to a data register is a write to
nonvolatile memory and takes a minimum of tWR to
complete. The transfer can occur between one of the
four potentiometers and one of its associated registers;
or it may occur globally, wherein the transfer occurs
between all four of the potentiometers and one of their
associated registers.
The next byte sent to the X9241 contains the instruction
and register pointer information. The four most significant bits are the instruction. The next four bits point to
one of four pots and when applicable they point to one
of four associated registers. The format is shown below
in Figure 2.
Figure 2. Instruction Byte Format
Four instructions require a three-byte sequence to
complete. These instructions transfer data between the
host and the X9241; either between the host and one of
the data registers or directly between the host and the
WCR. These instructions are: Read WCR, read the
current wiper position of the selected pot; Write WCR,
change current wiper position of the selected pot; Read
Data Register, read the contents of the selected nonvolatile register; Write Data Register, write a new value
to the selected data register. The sequence of operations is shown in Figure 4.
POTENTIOMETER
SELECT
I3
I2
I1
I0
P1
P0
INSTRUCTIONS
R1
R0
REGISTER
SELECT
3864 ILL F09.1
The Increment/Decrement command is different from
the other commands. Once the command is issued and
the X9241 has responded with an acknowledge, the
master can clock the selected wiper up and/or down in
one segment steps; thereby, providing a fine tuning
capability to the host. For each SCL clock pulse (tHIGH)
while SDA is HIGH, the selected wiper will move one
resistor segment towards the VH terminal. Similarly, for
each SCL clock pulse while SDA is LOW, the selected
wiper will move one resistor segment towards the VL
terminal. A detailed illustration of the sequence and
timing for this operation are shown in Figures 5 and 6
respectively.
The four high order bits define the instruction. The next
two bits (P1 and P0) select which one of the four
potentiometers is to be affected by the instruction. The
last two bits (R1 and R0) select one of the four registers
that is to be acted upon when a register oriented instruction is issued.
Four of the nine instructions end with the transmission of
the instruction byte. The basic sequence is illustrated in
Figure 3. These two-byte instructions exchange data
between the WCR and one of the data registers. A
transfer from a data register to a WCR is essentially a
write to a static RAM. The response of the wiper to this
Figure 3. Two-Byte Command Sequence
SCL
SDA
S
T
A
R
T
0
1
0
1
A3
A2
A1
A0
A
C
K
I3
I2
I1
I0
P1 P0
R1 R0
A
C
K
S
T
O
P
3864 ILL F10
4
X9241
Figure 4. Three-Byte Command Sequence
SCL
SDA
S
T
A
R
T
0
1
0
1
A3
A2
A1
A0
A
C
K
I3
I2
I1
I0
P1 P0
R1 R0
CM DW D5 D4 D3
A
C
K
D2
S
T
O
P
A
C
K
D1 D0
3864 ILL F11
Figure 5. Increment/Decrement Command Sequence
SCL
SDA
X
S
T
A
R
T
0
1
0
1
A3
A2
A1
A0
A
C
K
I3
I2
I1
I0
P1 P0
X
R1 R0
A
C
K
I
N
C
1
I
N
C
2
I
N
C
n
D
E
C
1
D
E
C
n
S
T
O
P
3864 FHD F12
Figure 6. Increment/Decrement Timing Limits
INC/DEC
CMD
ISSUED
tCLWV
SCL
SDA
VW
VOLTAGE OUT
3864 ILL F13
5
X9241
Table 1. Instruction Set
Instruction
Read WCR
I3
1
I2
0
Instruction Format
I1
I0
P1
P0
R1
Ro
(7)
(8)
0
1 1/0
1/0 N/A
N/A
Write WCR
1
0
1
0
1/0
1/0
N/A
N/A
Read Data
Register
Write Data
Register
XFR Data Register to WCR
1
0
1
1
1/0
1/0
1/0
1/0
1
1
0
0
1/0
1/0
1/0
1/0
1
1
0
1
1/0
1/0
1/0
1/0
XFR WCR to
Data Register
1
1
1
0
1/0
1/0
1/0
1/0
Global XFR Data
Register to WCR
0
0
0
1
N/A
N/A
1/0
1/0
Global XFR WCR
to Data Register
1
0
0
0
N/A
N/A
1/0
1/0
Increment/Decrement Wiper
0
0
1
0
1/0
1/0
N/A
N/A
Operation
Read the contents of the Wiper Counter
Register pointed to by P1–P0
Write new value to the Wiper Counter
Register pointed to by P1–P0
Read the contents of the Register
pointed to by P1–P0 and R1–R0
Write new value to the Register
pointed to by P1–P0 and R1–R0
Transfer the contents of the Register
pointed to by P1–P0 and R1–R0
to its associated WCR
Transfer the contents of the WCR
pointed to by P1–P0 to the Register
pointed to by R1–R0
Transfer the contents of all four Data
Registers pointed to by R1–R0 to their
respective WCR
Transfer the contents of all WCRs
to their respective data Registers
pointed to by R1–R0
Enable Increment/decrement of the
WCR pointed to by P1–P0
3864 PGM T02.1
Notes: (7) 1/0 = data is one or zero
(8) N/A = Not applicable or don't care; that is, a data register is not involved in the operation and need not be addressed (typical)
Figure 7. Acknowledge Response from Receiver
SCL FROM
MASTER
1
8
9
DATA
OUTPUT
FROM
TRANSMITTER
DATA
OUTPUT
FROM
RECEIVER
START
ACKNOWLEDGE
3864 ILL F14
6
X9241
DETAILED OPERATION
The WCR is a volatile register; that is, its contents are
lost when the X9241 is powered-down. Although the
register is automatically loaded with the value in R0
upon power-up, it should be noted this may be different
from the value present at power-down.
All four E2POT potentiometers share the serial interface
and share a common architecture. Each potentiometer
is comprised of a resistor array, a wiper counter register
and four data registers. A detailed discussion of the
register organization and array operation follows.
Data Registers
Each potentiometer has four nonvolatile data registers.
These can be read or written directly by the host and
data can be transferred between any of the four data
registers and the WCR. It should be noted all operations
changing data in one of these registers is a nonvolatile
operation and will take a maximum of 10ms.
Wiper Counter Register
The X9241 contains four wiper counter registers (WCR),
one for each E2POT potentiometer. The WCR can be
envisioned as a 6-bit parallel and serial load counter with
its outputs decoded to select one of sixty-four switches
along its resistor array. The contents of the WCR can be
altered in four ways: it may be written directly by the host
via the Write WCR instruction (serial load); it may be
written indirectly by transferring the contents of one of
four associated data registers via the XFR Data Register
instruction (parallel load); it can be modified one step at
a time by the Increment/ Decrement instruction; finally,
it is loaded with the contents of its data register zero (R0)
upon power-up.
If the application does not require storage of multiple
settings for the potentiometer, these registers can be
used as regular memory locations that could possibly
store system parameters or user preference data.
Figure 8. Detailed Potentiometer Block Diagram
SERIAL DATA PATH
VH
SERIAL
BUS
INPUT
FROM INTERFACE
CIRCUITRY
REGISTER 0
REGISTER 1
8
6
REGISTER 2
REGISTER 3
PARALLEL
BUS
INPUT
WIPER
COUNTER
REGISTER
2
INC/DEC
LOGIC
IF WCR = 00[H] THEN VW = VL
UP/DN
IF WCR = 3F[H] THEN VW = VH
MODIFIED SCL
UP/DN
CLK
C
O
U
N
T
E
R
D
E
C
O
D
E
VL
DW
CASCADE
CONTROL
LOGIC
VW
CM
3864 ILL F15
7
X9241
Cascade Mode
DW bit of the WCR is set to “0” the wiper is enabled;
when set to “1” the wiper is disabled. If the wiper is
disabled, the wiper terminal will be electrically isolated
and float.
The X9241 provides a mechanism for cascading the
arrays. That is, the sixty-three resistor elements of one
array may be cascaded (linked) with the resistor elements of an adjacent array.
When operating in cascade mode VH, VL and the wiper
terminals of the cascaded arrays must be electrically
connected externally. All but one of the wipers must be
disabled. The user can alter the wiper position by writing
directly to the WCR or indirectly by transferring the
contents of the data registers to the WCR or by using the
Increment/Decrement command.
Cascade Control Bits
The data byte, for the three-byte commands, contains 6
bits (LSBs) for defining the wiper position plus two high
order bits, CM (Cascade Mode) and DW (Disable Wiper).
The state of CM enables or disables (normal operation)
cascade mode. When the CM bit of the WCR is set to “0”
the potentiometer is in the normal operation mode.
When the CM bit of the WCR is set to “1” the potentiometer
is cascaded with its adjacent higher order potentiometer.
For example; if bit 7 of WCR2 is set to “1”, pot 2 will be
cascaded to pot 3.
When using the Increment/Decrement command the
wiper position will automatically transition between
arrays. The current position of the wiper can be determined by reading the WCR registers; if the DW bit is “0”,
the wiper in that array is active. If the current wiper
position is to be maintained, a global XFR WCR to Data
Register command must be issued before power-down.
The state of DW enables or disables the wiper. When the
Figure 9. Cascading Arrays
VL0
POT 0
VH0
WCR0
VW0
VL1
POT 1
VH1
WCR1
VW1
VL2
POT 2
VH2
WCR2
VW2
VL3
POT 3
VH3
WCR3
= EXTERNAL
CONNECTION
VW3
3864 ILL F16.1
8
X9241
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on SCK, SCL or any Address Input
with Respect to VSS ................................... –1V to +7V
Voltage on any VH or VL Referenced to VSS ......... ±8V
∆V = |VH–VL| ......................................................... 16V
Lead Temperature (Soldering, 10 seconds)...... 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Military
Min.
Max.
Supply Voltage
Limits
0°C
–40°C
–55°C
+70°C
+85°C
+125°C
X9241
5V ±10%
3864 PGM T04.1
3864 PGM T03
ANALOG CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
Parameter
RTOTAL End to End Resistance
Power Rating
IW
Wiper Current
RW
Wiper Resistance
VTERM Voltage on any VH or
or VL Pin
Noise
Resolution (4)
Absolute Linearity (1)
Relative Linearity (2)
Temperature Coefficient
Min.
–20
–1
–5
Limits
Typ.
Max.
+20
50
+1
40
100
+5
≤120
1.6
0.4
+1
+0.2
–1
–0.2
±300
Units
%
mW
mA
Ω
V
dB/
%
MI(3)
MI(3)
ppm/°C
Test Conditions
25°C, each pot
Wiper Current = ± 1mA
Ref: 1V
Vw(n)(actual) – Vw(n)(expected)
Vw(n + 1) – [Vw(n) + MI]
3864 PGM T05.2
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
Parameter
lCC
Supply Current (Active)
ISB
ILI
ILO
VIH
VIL
VOL
VCC Current (Standby)
Input Leakage Current
Output Leakage Current
Input HIGH Voltage
Input LOW Voltage
Output LOW Voltage
Min.
Limits
Typ.
Max.
3
200
500
10
10
VCC + 1
0.8
0.4
2
–1
Units
mA
µA
µA
µA
V
V
V
Test Conditions
fSCL = 100KHz, SDA = Open,
Other Inputs = VSS
SCL=SDA=VCC, Addr. = VSS
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
3864 PGM T06.3
Notes: (1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper
position when used as a potentiometer.
(2) Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (VH – VL)/63, single pot
(4) Max. = all four arrays cascaded together, Typical = individual array resolutions.
9
X9241
ENDURANCE AND DATA RETENTION
Parameter
Min.
Units
Minimum Endurance
Data Retention
100,000
100
Data Changes per Register
Years
3864 PGM T07.2
CAPACITANCE
Symbol
(5)
CI/O
CIN(5)
Parameter
Max.
Units
Test Conditions
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, A3 and SCL)
8
6
pF
pF
VI/O = 0V
VIN = 0V
3864 PGM T08
POWER-UP TIMING
Symbol
Parameter
Max.
Units
tPUR(6)
tPUW(6)
Power-up to Initiation of Read Operation
Power-up to Initiation of Write Operation
1
5
ms
ms
3864 PGM T09
A.C. CONDITIONS OF TEST
Input Pulse Levels
EQUIVALENT A.C. TEST CIRCUIT
VCC x 0.1 to VCC x 0.9
Input Rise and
Fall Times
Input and Output
Timing Levels
5V
10ns
1533Ω
SDA OUTPUT
VCC x 0.5
3864 PGM T10
100pF
Notes: (5) This parameter is periodically sampled and not 100%
tested.
(6) tPUR and tPUW are the delays required from the time
VCC is stable until the specified operation can be
initiated. These parameters are periodically sampled
and not 100% tested.
3864 ILL F02.1
Guidelines for Calculating
Typical Values of Bus Pull-Up Resistors
SYMBOL TABLE
OUTPUTS
120
Must be
steady
Will be
steady
100
May change
from LOW
to HIGH
Will change
from LOW
to HIGH
May change
from HIGH
to LOW
Will change
from HIGH
to LOW
INPUTS
Don’t Care:
Changes
Allowed
N/A
RESISTANCE (KΩ)
WAVEFORM
RMIN =
80
VCC MAX
RMAX =
IOL MIN
=1.8KΩ
tR
CBUS
MAX.
RESISTANCE
60
40
20
MIN.
RESISTANCE
0
Changing:
State Not
Known
Center Line
is High
Impedance
0
20
40
60
80 100 120
BUS CAPACITANCE (pF)
3864 ILL F17
10
X9241
A.C. CHARACTERISTICS (Over recommended operating conditions unless otherwise stated)
Limits
Symbol
Parameter
Min.
Max.
Units
fSCL
SCL Clock Frequency
0
100
KHz
tLOW
Clock LOW Period
4700
ns
tHIGH
Clock HIGH Period
4000
ns
tR
SCL and SDA Rise Time
1000
ns
tF
SCL and SDA Fall Time
300
ns
Ti
Noise Suppression Time Constant
100
ns
(Glitch Filter)
tSU:STA
Start Condition Setup Time (for a Repeated
4700
ns
Start Condition)
tHD:STA
Start Condition Hold Time
4000
ns
tSU:DAT
Data in Setup Time
250
ns
tHD:DAT
Data in Hold Time
0
ns
tAA
SCL LOW to SDA Data Out Valid
300
3500
ns
tDH
Data Out Hold Time
300
ns
tSU:STO
Stop Condition Setup Time
4700
ns
tBUF
Bus Free Time Prior to New Transmission
4700
ns
tWR
Write Cycle Time (Nonvolatile Write Operation)
10
ms
tSTPWV
Wiper Response Time From Stop Generation
500
µs
tCLWV
Wiper Response From SCL LOW
1000
µs
tR VCC
VCC Power-up Rate
0.2
50
mV/µs
Reference
Figure
10
10
10
10
10
10
10 & 12
10 & 12
10
10
11
11
10 & 12
10
13
13
6
3864 PGM T11.3
Figure 10. Input Bus Timing
tHIGH
tLOW
tF
tR
SCL
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
SDA
(DATA IN)
tBUF
3864 ILL F03
11
X9241
Figure 11. Output Bus Timing
SCL
tAA
tDH
SDA OUT (ACK)
SDA
SDA OUT
SDA OUT
3864 ILL F04
Figure 12. Start Stop Timing
START CONDITION
STOP CONDITION
SCL
tSU:STA
tHD:STA
tSU:STO
SDA
DATA IN
3864 ILL F05
Figure 13. Write Cycle and Wiper Response Timing
SCL
CLOCK 8
CLOCK 9
START
STOP
tWR
SDA
SDAIN
ACK
tSTPWV
WIPER
OUTPUT
3864 ILL F06
12
X9241
PACKAGING INFORMATION
20-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P
1.060 (26.92)
0.980 (24.89)
0.280 (7.11)
0.240 (6.096)
PIN 1 INDEX
PIN 1
—
0.005 (0.127)
0.900 (23.66)
REF.
0.195 (4.95)
0.115 (2.92)
SEATING
PLANE
––
0.015 (0.38)
(3.81) 0.150
(2.92) 0.1150
0.10 (BSC)
(2.54)
0.022 (0.559)
0.014 (0.356)
0.070 (1.778)
0.045 (1.143)
0.300
(7.62) (BSC)
0°
15°
0.014 (0.356)
0.008 (0.2032)
NOTE:
1. ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
2. PACKAGE DIMENSIONS EXCLUDE MOLDING FLASH
3926 FHD F18.1
13
X9241
PACKAGING INFORMATION
20-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.290 (7.37)
0.299 (7.60)
0.393 (10.00)
0.420 (10.65)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.020 (0.50)
0.496 (12.60)
0.508 (12.90)
(4X) 7°
0.092 (2.35)
0.105 (2.65)
0.003 (0.10)
0.012 (0.30)
0.050 (1.27)
0.050" Typical
0.010 (0.25)
X 45°
0.020 (0.50)
0.050"
Typical
0° – 8°
0.420"
0.007 (0.18)
0.011 (0.28)
0.015 (0.40)
0.050 (1.27)
FOOTPRINT
0.030" Typical
20 Places
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F23
14
X9241
PACKAGING INFORMATION
20-LEAD PLASTIC, TSSOP PACKAGE TYPE V
.025 (.65) BSC
.169 (4.3)
.252 (6.4) BSC
.177 (4.5)
.252 (6.4)
.300 (6.6)
.047 (1.20)
.0075 (.19)
.0118 (.30)
.002 (.05)
.006 (.15)
.010 (.25)
Gage Plane
0° – 8°
Seating Plane
.019 (.50)
.029 (.75)
Detail A (20X)
.031 (.80)
.041 (1.05)
See Detail “A”
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
3926 FHD F45
15
X9241
ORDERING INFORMATION
X9241
Y
P
T
V
VCC Limits
Blank = 5V ±10%
Device
Temperature Range
Blank = Commercial = 0°C to +70°C
I = Industrial = –40°C to +85°C
M = Military = –55°C to +125°C
Package
P = 20-Lead Plastic DIP
S = 20-Lead SOIC
V = 20-Lead TSSOP
Potentiometer Organization
Pot 0 Pot 1 Pot 2 Pot 3
Y = 2K
2K
2K
2K
W = 10K 10K 10K 10K
U = 50K 50K 50K 50K
M = 2K 10K 10K 50K
LIMITED WARRANTY
Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty,
express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement.
Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and
prices at any time and without notice.
Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, licenses are
implied.
U.S. PATENTS
Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481; 4,404,475;
4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967; 4,883, 976. Foreign patents and
additional patents pending.
LIFE RELATED POLICY
In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error
detection and correction, redundancy and back-up features to prevent such an occurrence.
Xicor's products are not authorized for use in critical components in life support devices or systems.
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant
injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or effectiveness.
16