MDS105 Unmanaged 5-Port 10/100 Mbps Ethernet Switch Data Sheet Features November 2003 • 4 10/100 Mbps auto-negotiating RMII ports • 1 10/100 Mbps auto-negotiating MII/serial port (Port 4) that can be used as a WAN uplink or as a 5th port • Ordering Information External I2C EEPROM for power-up configuration - Up to 4 port-based VLANs • Full wire-speed layer 2 switching on all ports (up to 1.448 M packets per second) • Internal 1 k MAC address table - Auto address learning - Auto address aging • - Packet scheduling based on Weighted RoundRobin (WRR) and Weighted Random Early Detection/Drop (WRED) - Input ports are defined to be high or low priority - Allows explicit identification of IP Phone ports Ports 0 & 1 can be trunked to provide a 200 Mbps link to another switch or server • Utilizes a single low-cost external Pipelined, SyncBurst SRAM (SBRAM) for buffer memory - • 2 queues per output port Provides port-based prioritization of packets on up to 2 ports (0-1) • Leading edge QoS capabilities provided based on 802.1p and IP TOS/DS field - 208 Pin PQFP -40°C to +85°C Default mode allows operation without external EEPROM • • MDS105AL 256 k bytes or 512 k bytes (1 chip) Flow Control capabilities - Provides back pressure for half duplex - 802.3x flow control for full duplex • Special power-saving mode for inactive ports - Without flow control can drop packets during congestion using WRED • Ability to support WinSock2.0 and Windows2000 smart applications - 2 levels of packet drop provided • Transmit delay control capabilities • Supports both Full/Half duplex ports - Provides maximum delay guarantee (<1 ms) • Supports external parallel port for configuration updates - Supports mixed voice-data networks • Port 3 can be used to mirror traffic from the other 3 ports (0-2) • MDS105 5-Port Switch Chip S S R A M Optimized pin-out for easy board layout MII 10/100 Phy RMII Quad 10/100 Phy Figure 1 - System Block Diagram 1 Zarlink Semiconductor Inc. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright 2003, Zarlink Semiconductor Inc. All Rights Reserved. MDS105 Data Sheet Description The MDS105 is a fully integrated 5 port Ethernet switch designed to support the low-cost requirements of unmanaged switch applications. The MDS105 provides features that are normally not associated with plug-andplay technology, while not requiring an external processor to facilitate their utilization. The MDS105 begins operating immediately at power-up, learning addresses automatically and forwarding packets at full wire-speed to any of its four output ports or the uplink expansion port. The default configuration allows operation without using an external EEPROM. With an EEPROM to configure the device at power-up, however, the MDS105 provides flexible features: port trunking, port mirroring, port-based VLANs, and Quality of Service (QoS) capabilities that are usually associated only with managed switches. The built-in intelligence of the MDS105 allows it to recognize and offer packet prioritization using Zarlink’s QoS scheme. Packets are prioritized based upon their layer 2 VLAN priority tag or the layer 3 Type-OfService/Differentiated Services (TOS/DS) field. This priority can be defined as transmit and/or drop priority. The MDS105 can be used to create a 4 port unmanaged switch with one WAN router port by connecting a CPU (ARM or MPC 850) to the additional MII port (Port 4). The only external components needed are the physical layer transceivers and a single SBRAM, resulting in a low total system cost. Designed to support the requirements of converging networks, the MDS105 utilizes a power conserving architecture. To further enhance this power management, the chip automatically detects when a switch port is not being utilized, and turns off the logic associated with that port, thereby saving power and reducing the current load on the switch power supply. Operating at 66 MHz internally, and with a 66 MHz interface to the external SBRAM, the MDS105 sustains full wirespeed switching on all 5 ports. The chip is packaged in a small 208 pin Plastic Quad Flat-Pak (PQFP) package. 2 Zarlink Semiconductor Inc. MDS105 Data Sheet LA_[6] VSS L_A[5] L_A[4] L_A[3] L_A[18] VDD L_D[31] L_D[30] L_D[29] VSS (CORE) L_D[28] L_D[27] L_D[26] VDD L_D[25] L_D[24] L_D[23] L_D[22] VSS L_D[21] L_D[20] L_D[19] L_D[18] VDD (CORE) L_D[17] L_D[16] L_D[15] VSS L_D[14] L_D[13] L_D[12] L_D[11] VDD L_D[10] L_D[9] L_D[8] VSS (CORE) L_D[7] L_D[6] L_D[5] L_D[4] VDD L_D[3] L_D[2] L_D[1] VSS L_D[0] L_A[15] VDD(CORE) L_A[16] L_ADSC# MDS105 Physical Pinout 208 206 204 202 200 198 196 194 192 190 188 186 184 182 180 178 176 174 172 170 168 166 164 162 160 158 2 4 + 154 Buffer Mem Interface 152 Pin 1 I.D. Config Interfaces 6 8 10 12 14 20 22 24 26 28 30 RMII Port Interfaces 16 18 156 150 148 146 144 142 140 138 136 134 132 130 128 126 32 124 34 122 36 120 38 118 40 116 42 114 44 112 46 110 48 108 50 RMII Port Interfaces 106 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 NC NC NC NC NC NC VDD NC NC NC NC NC NC VSS NC NC NC NC NC NC VDD (CORE) M2_TXEN M2_TXD[0] M2_TXD[1] M2_CRS_DV M2_RXD[0] M2_RXD[1] VSS (CORE) M3_TXEN M3_TXD[0] M3_TXD[1] M3_CRS_DV M3_RXD[0] M3_RXD[1] VDD NC NC NC NC NC NC VSS M_CLK VDD (CORE) M4_RXDV M4_COL VSS M4_RXCLK VDD M4_RXD[0] M4_RXD[1] M4_RXD[2] L_A[7] L_A[8] VDD_CORE L_A[9] L_A[10] L_A[11] VSS L_A[12] L_A[13] L_A[14] VDD NC NC NC NC NC NC VSS (CORE) M0_TXEN M0_TXD[0] M0_TXD[1] M0_CRS_DV M0_RXD[0] M0_RXD[1] VDD M1_TXEN M1_TXD[0] M1_TXD[1] M1_CRS_DV M1_RXD[0] M1_RXD[1] VSS NC NC NC NC NC NC VSS (CORE) NC NC NC NC NC NC VSS(CORE) NC NC NC NC NC NC 3 Zarlink Semiconductor Inc. L_OE# L_WE# VSS L_CLK VDD L_A[17] L_A[2] VSS SCLK VDD MIR_CTL[3] MIR_CTL[2] MIR_CTL[1] MIR_CTL[0] RSTIN# RSTOUT# VSS(CORE) T_MODE TSTOUT[7] TSTOUT[6] TSTOUT[5] TSTOUT[4] TSTOUT[3] TSTOUT[2] TSTOUT[1] TSTOUT[0] VDD (CORE) ACK DATA0 STROBE TRUNK_EN TEST# SDA SCL M_MDIO VSS M_MDC VDD M4_REFCLK VSS M4_SPEED M4_DUPLEX M4_LINK M4_TXD[3] M4_TXD[2] M4_TXD[1] M4_TXD[0] M4_TXEN VDD M4_TXCLK VSS (CORE) M4_RXD[3] MDS105 PIN Reference Table Pin # Pin Name 1 L_A[7] 2 L_A[8] 3 VDD (CORE) 4 L_A[9] 5 L_A[10] 6 L_A[11] 7 VSS 8 L_A[12] 9 L_A[13] 10 L_A[14] 11 VDD 12 NC 13 NC 14 NC 15 NC 16 NC 17 NC 18 VSS (CORE) 19 M0_TXEN 20 M0_TXD[0] 21 M0_TXD[1] 22 M0_CRS_DV 23 M0_RXD[0] 24 M0_RXD[1] 25 VDD 26 M1_TXEN 27 M1_TXD[0] 28 M1_TXD[1] 29 M1_CRS_DV 30 M1_RXD[0] 31 M1_RXD[1] 32 VSS 33 NC 34 NC Data Sheet 35 NC 71 M5_RXD[0] 36 NC 72 M5_RXD[1] 37 NC 73 VDD (CORE) 38 NC 74 M6_TXEN 39 VDD (CORE) 75 M6_TXD[0] 40 NC 76 M6_TXD[1] 41 NC 77 M6_CRS_DV 42 NC 78 M6_RXD[0]] 43 NC 79 M6_RXD[1] 44 NC 80 VSS (CORE) 45 NC 81 M7_TXEN 46 VSS (CORE) 82 M7_TXD[0] 47 NC 83 M7_TXD[1] 48 NC 84 M7_CRS_DV 49 NC 85 M7_RXD[0] 50 NC 86 M7_RXD[1] 51 NC 87 VDD 52 NC 88 NC 53 NC 89 NC 54 NC 90 NC 55 NC 91 NC 56 NC 92 NC 57 NC 93 NC 58 NC 94 VSS 59 VDD 95 M_CLK 60 NC 96 VDD (CORE) 61 NC 97 M8_RXDV/S8_CRS_DV 62 NC 98 M8_COL/S8_COL 63 NC 99 VSS 64 NC 100 M8_RXCLK/S8_RXCLK 65 NC 101 VDD 66 VSS 102 M8_RXD[0]/S8_RXD 67 NC 103 M8_RXD[1] 68 NC 104 M8_RXD[2] 69 NC 105 M4_RXD[3] 70 NC 106 VSS (CORE) 4 Zarlink Semiconductor Inc. MDS105 Data Sheet 107 M8_TXCLK/S8_TXCLK 142 RSTIN# 178 L_D[13] 108 VDD 143 MIRROR_CONTROL[0] 179 L_D[14] 109 M8_TXEN[0]/S8_TXEN 144 MIRROR_CONTROL[1] 180 VSS 110 M8_TXD[0]/S8_TXD 145 MIRROR_CONTROL[2] 181 L_D[15] 111 M8_TXD[1] 146 MIRROR_CONTROL[3] 182 L_D[16] 112 M8_TXD[2] 147 VDD 183 L_D[17] 113 M8_TXD[3] 148 SCLK 184 VDD (CORE) 114 M8_LINK/S8_LINK 149 VSS 185 L_D[18] 115 M8_DUPLEX/S8_DUPL EX 150 L_A[2] 186 L_D[19] 151 L_A[17] 187 L_D[20] 116 M8_SPEED 152 VDD 188 L_D[21] 117 VSS 153 L_CLK 189 VSS 118 M8_REFCLK 154 VSS 190 L_D[22] 119 VDD 155 L_WE# 191 L_D[23] 120 M_MDC 156 L_OE# 192 L_D[24] 121 VSS 157 L_ADSC# 193 L_D[25] 122 M_MDIO 158 L_A[16] 194 VDD 123 SCL 159 VDD (CORE) 195 L_D[26] 124 SDA 160 L_A[15] 196 L_D[27] 125 TEST# 161 L_D[0] 197 L_D[28] 126 TRUNK_ENABLE 162 VSS 198 VSS (CORE) 127 STROBE 163 L_D[1] 199 L_D[29] 128 DATA0 164 L_D[2] 200 L_D[30] 129 ACK 165 L_D[3] 201 L_D[31] 130 VDD (CORE) 166 VDD 202 VDD 131 TSTOUT[0] 167 L_D[4] 203 L_A[18] 132 TSTOUT[1] 168 L_D[5] 204 L_A[3] 133 TSTOUT[2] 169 L_D[6] 205 L_A[4] 134 TSTOUT[3] 170 L_D[7] 206 L_A[5] 135 TSTOUT[4] 171 VSS (CORE) 207 VSS 136 TSTOUT[5] 172 L_D[8] 208 L_A[6] 137 TSTOUT[6] 173 L_D[9] 138 TSTOUT[7] 174 L_D[10] 139 T_MODE 175 VDD 140 VSS (CORE) 176 L_D[11] 141 RSTOUT# 177 L_D[12] 5 Zarlink Semiconductor Inc. MDS105 MDS105 Block Diagram Figure 2 - MDS105 Block Diagram 6 Zarlink Semiconductor Inc. Data Sheet MDS105 1.0 Data Sheet Functional Operation The MDS105 is designed to provide a cost effective layer 2 switching solution, using technology from the Zarlink family to offer a highly integrated product for the unmanaged, Differentiated Services (DS) ready, Ethernet switch market. Five 10/100 Media Access Controllers (MAC) provide the protocol interface. These MACs perform the required packet checks to ensure that each packet that is provided to the Frame Engine has met all the IEEE 802.1 standards. Each MAC supports half duplex “back pressure,” and full duplex 802.3x “PAUSE” Flow Control. The PHY addresses for the 4 RMII MACs are from 08h to 0Bh. These four ports are denoted as ports 0 to 3. The PHY address for the uplink MAC is 10 h. This port is denoted as Port 4. Data packets longer than 1518 (1522 with VLAN tag) bytes and shorter than 64 bytes are dropped, and the MDS105 is designed to support minimum interframe gaps between incoming packets. The Frame Engine (FE) is the primary packet buffering and forwarding engine within the MDS105. As such, the FE controls the storage of packets into and out of the external frame buffer memory, keeps track of frame buffer availability, and schedules packet transmissions. While packet data is being buffered, the FE extracts the necessary information from each packet header and sends it to the Search Engine for processing. Search results returned to the FE initiate the scheduling of packet transmission. When a packet is chosen for transmission, the FE reads the packet from external buffer memory and places it in the output FIFO of the output port. 2.0 Address Learning and Aging The MDS105 is able to begin address learning and packet forwarding shortly after power up is completed. The Search Engine examines the contents of its internal Switch Database Memory for each valid packet that is received on a MDS105 input port. Unknown source and destination MAC addresses are detected when the Search Engine does not find a match within its database. These unknown source MAC addresses are learned by creating a new entry in the switch database memory, and storing the necessary resulting information in that location. Subsequent searches to a learned destination MAC address will return the new contents of that MAC Control Table (MCT) entry. After each source address search the MCT entry aging flag is updated. MCT entries that have not been accessed during a user configurable time period (1 to 67,108 seconds) will be removed. This aging time period can be configured using the 16 bit value stored in the registers MAC Address Aging Timer Low and High (AGETIME_LOW, AGETIME_HIGH). The aging period is defined as the bit concatenation of AGETIME_HIGH with AGETIME_LOW, multiplied by 1024 ms. For example, if AGETIME_LOW = 25, and AGETIME_HIGH = 01 (in hexadecimal), then the concatenated value 125 is equal to decimal 293. Multiplying 293 by 1024 ms, we determine that the corresponding aging time is 300 ms. In fact, 300 ms is the default aging time for the MDS105. The aging of all MCT entries is checked once during each time period. If the MCT entry has not been exercised before the end of the next time period, it will be deleted. 3.0 Quality of Service The MDS105 applies Zarlink’s architecture to provide new Quality of Service (QoS) capabilities for unmanaged switch applications. Similar to the QoS capabilities of other Zarlink chipset members, the MDS105 offers two transmit queues per output port. The Frame Engine (FE) manages the output transmission queues for all MDS105 ports. Once the destination address search is complete, and the switch decision is sent back to the FE, the packet is inserted into the appropriate output queue. Whether the packet is inserted into a high or low priority queue is determined by either the VLAN tag information or the Type of Service/Differentiated Services (TOS/DS) field in the IP header. Either of these priority fields can be used to select the transmission priority (as per the USE_TOS bit in the FCR register). 7 Zarlink Semiconductor Inc. MDS105 Data Sheet The mapping of the priority field values into either the high or low priority queue can be configured using the MDS105 configuration registers AVPM and TOSPM. If the system uses the TOS/DS field to prioritize packets, there are two choices regarding which bits of the TOS/DS field are used. Bits [0:2] of the TOS byte (known as the IP precedence field) or bits [3:5] of the TOS byte (known as the Delay/Throughput Reliability (DTR) field) can be used to resolve the transmission queue priority. Either bit group, [0:2] or [3:5], can also be used to resolve packet drop precedence, as per bits 6 and 7 of the register FCBST. The MDS105 utilizes Weighted Round Robin (WRR) to schedule packets for transmission. To enable MDS105’s intelligent QoS scheduling capabilities, the use of an external EEPROM to change the default register configurations is required. Weighted Round Robin is an efficient method to ensure that each of the transmission queues receives at least a minimum service level. With two output transmission queues, the MDS105 will transmit X packets from the high priority queue before transmitting a single packet from the low priority queue. The MDS105 allows the designer to set the high priority weight X to a value between 1 and 15. If both queues contain packets, and the high priority weight is set to the value 4, then the MDS105 will transmit 4 high priority packets before transmitting each low priority packet. The MDS105 also employs a proprietary mechanism to ensure the timely delivery of high priority packets. When the latency of high priority packets reaches a threshold, the MDS105 will override the WRR weights and transmit only high priority packets until the high priority packet delays are below the threshold. This threshold limit is 1 ms (last-infirst-out). The MDS105’s proprietary scheduling algorithm is also designed to push low priority traffic through the device faster, if necessary, to unclog congested queues. Loading the appropriate values into the configuration registers enables the QoS scheduling capabilities of the MDS105. QoS for packet transmission is enabled by performing the following four steps: 1. Select the TOS/DS or VLAN Priority Tag field as the decision-maker for IP packet scheduling. The selection is made using bit 7 of the Flooding Control Register (FCR). - FCR[7] = 0: Use VLAN Priority Tag field to determine the transmission priority, if this Tag field exists. - FCR[7] = 1: Use TOS/DS field for IP packet priority resolution. 2. Select which TOS/DS subfield to use as the decision-maker for packet transmission priority if the TOS/DS field was selected in step 1. The selection is made using bit 6 of the FCB Buffer Low Threshold Register (FCBST). - FCBST[6] = 0: Use DTR subfield to resolve the transmission priority. - FCBST[6] = 1: Use IP precedence subfield1 to resolve the transmission priority. 3. Enable QoS using bit 5 of the Transmission Scheduling Control Register (AXSC). Set the transmission queue weight for the high priority queue using bits 0 to 3. 4. Create the mapping from the value in the TOS/DS or VLAN Priority Tag field to the corresponding high or low priority output queue. The mapping is created using the VLAN Priority Map (AVPM) and TOS Priority Map (TOSPM) registers. Note that for half duplex operation, the priority queues2 must be enabled using bit 7 in the Transmission Scheduling Control (AXSC) register to use QoS scheduling. When QoS and flow control are enabled, the MDS105 will utilize enhanced WRR to schedule packet transmission, and will use either back pressure or 802.3X flow control to handle buffer congestion. When QoS is enabled and flow control is disabled, the MDS105 will utilize enhanced WRR to schedule packet transmission, and will use Weighted Random Early Detection/Drop (WRED) to drop random packets in order to handle buffer congestion. Because of WRED, only a few packet flows are slowed down while the remaining see no impact from the network traffic congestion. 1. IP precedence and DTR subfields are referred to as TOS/DS[0:2] and TOS/DS[3:5] in the IP TOS/DS byte. 2. In Half Duplex mode, QoS scheduling functions are disabled by default. 8 Zarlink Semiconductor Inc. MDS105 Data Sheet WRED is a method of handling traffic congestion in the absence of flow control mechanisms1. When flow control is enabled, all devices that are connected to a switch node that is exercising flow control are effectively unable to transmit, including nodes that are not directly responsible for the congestion problem. This inability to transmit during flow control periods would wreak havoc with voice packets, or other high priority packet flows, and therefore flow control is not recommended for networks that mix voice and data traffic. WRED allows traffic to continue flowing into ports on a switch, and randomly drops packets with different probabilities based upon each packet’s priority markings. As the switch congestion increases, the probability of dropping an incoming packet increases, and as congestion decreases, the probability of dropping an incoming packet decreases. Not surprisingly, packets designated high-drop are sacrificed with higher odds during congestion than packets designated low-drop. The following table summarizes the WRED operation of the MDS105. It lists the buffer thresholds at which each drop probability takes effect. WRED Threshold Condition for High Priority Queue Level 0 Level 1 Level 2 Drop Percentage Condition for Low Priority Queue Drop Percentage for High-Drop Packet Drop Percentage for Low-Drop Packet 50% 0% 72 buffers occupied 75% 25% 84 buffers occupied 100% 50% Total buffer space available in device is ≤LPBT 24 buffers occupied Table 1 - WRED Operation of the MDS105 The WRED packet drop capabilities of the MDS105 are enabled by performing the following four steps: 1. Select the TOS/DS or VLAN Tag field as the decision-maker for dropping packets. The selection is made using bit 7 of the Flooding Control Register (FCR). - FCR[7] = 0: Use VLAN Priority Tag field to resolve the drop level, if this field exists. - FCR[7] = 1: Use TOS/DS field for IP packet drop level resolution. 2. Select which TOS/DS Tag subfield to use for dropping packets provided that the TOS/DS field was selected in step 1. The selection is made using bit 7 of the FCB Buffer Low Threshold Register (FCBST). - FCBST[7] = 0: Use DTR subfield to resolve the drop precedence. - FCBST[7] = 1: Use IP precedence subfield to resolve the drop precedence. 3. Create the mapping from the values in the TOS DS or VLAN Tag field to the packet flags representing high or low drop precedence. The mapping is created using the VLAN Discard Map (AVDM) and TOS Discard Map (TOSDM) registers. 4. Make sure that the desired ports are flow control disabled, using the ECR1Px registers. Note that to apply the WRED QoS function of the MDS105, flow control must be disabled. 1. Flow control, of course, provides the advantage of not dropping packets. However, its primary disadvantage is that a flow controlled port may experience head-of-line blocking. This means that if even 1 packet is destined to a congested output port, then all other packets originating from the same source may, in the worst case, be delayed – even if these other packets have uncongested destinations. On the other hand, WRED may cause some packet loss, but with no such head-of-line blocking problem. Which method of handling traffic congestion should be chosen will depend on the application. 9 Zarlink Semiconductor Inc. MDS105 3.1 Data Sheet A Few Examples • No QoS Scheduling Desired At All. The default setting for the MDS105 is no QoS scheduling at all. Packets are transmitted using a simple first-in-first-out (FIFO) approach, without the reordering that would result from prioritization. All destinations use 1 queue only. QoS scheduling can be disabled for the entire chip using AXSC[5]. • No QoS Scheduling Desired for Half Duplex Ports. It is possible to disable QoS for half duplex ports in the MDS105. Indeed, this is the default setting, because it is difficult to assure quality of service for half duplex ports, which tend to experience unpredictable delay. All destinations configured as half duplex use 1 transmission queue only in this setting. QoS scheduling can be disabled for all half duplex ports using AXSC[7]. • QoS Scheduling for Some Destinations, But Not Others. The MDS105 does not support this feature. The three options offered are: (a) all ports are QoS-enabled, (b) no ports are QoS-enabled, and (c) only full duplex ports are QoS-enabled. Of course, the MDS105 will still exhibit single-queue scheduling at a port if all packets destined for it are marked with a single transmission priority. • No Flow Control Desired. It is possible to disable flow control for the entire chip, regardless of the individual port settings. During congestion, some packets will be lost. This capability is located in AXSC[6]. • Flow Control Desired for Some Sources, But Not Others. By configuring each port separately using bit 0 in the ECR1Px registers, one may enable flow control for some ports, but not others. Flow control cannot be globally disabled in AXSC[6] if this function is to be achieved. At a congested destination, an incoming packet from a flow control enabled source will trigger a flow control message sent back to that source. On the other hand, an incoming packet from a flow control disabled source may or may not be dropped, as per WRED, but will never trigger flow control. • Scheduling vs. Dropping. Using the configuration registers in the MDS105, as in earlier examples, a port may or may not have flow control enabled, and a port may or may not have QoS scheduling enabled. All four combinations are permissible parameter settings, and which one is chosen depends on application. In one common application, suppose voice, critical data and web traffic packets originate from the same set of input ports, and are destined for the same set of output ports. The MDS105’s enhanced WRR scheduling can be used to ensure a delay bound for the voice packets. Furthermore, because we want to guarantee that web traffic congestion does not block critical data or voice, we must disable flow control and use WRED to intelligently drop packets. On the other hand, if the goal were file transfer without any packet dropping, one would enable the MDS105’s flow control function, which halts incoming traffic when the system is congested. QoS scheduling can be disabled, both because flow control may make quality of service unpredictable, and because, in any case, delay is not critical in this application. 3.2 Port-Based Prioritization Some applications may require an explicit prioritization of packets based upon the port the packet originates from. Defining specific ports of a switch to be IP Phone ports is a specific example that makes use of MDS105’s ability to assign default priorities to ports. The MDS105 can be configured to provide specific priority definitions on up to two ports (ports 0 – 1). These user defined port priorities override the packet priority markings (VLAN tag or TOS/DS), and the new priority is applied to all packets that enter the switch from that port. These port priority definitions are configured in the Port Priority (PTPRI) register. There are two bits for each of the two ports that can support port-based priorities. The EN bit allows the designer to turn on port priorities for each port, and the P bit allows the designer to select either high (1) or low (0) transmission priority for all packets that enter the switch through that port. When port priorities are enabled, the remaining ports will provide QoS based upon the VLAN Tag or TOS DS field mappings in the configuration registers. Only those ports that have port priorities enabled will override the priority mappings. 10 Zarlink Semiconductor Inc. MDS105 4.0 Data Sheet Buffer Management The MDS105 stores each input packet into the external frame buffer memory while determining the destination the packet is to be forwarded to. The total number of packets that can be stored in the frame buffer memory depends upon the size of the external SBRAM that is utilized. For a 256 KB SBRAM the MDS105 can buffer 170 packets. For a 512 KB SBRAM the MDS105 can buffer 340 packets. In order to provide good quality of service characteristics, the MDS105 must carefully allocate the available buffer space. Such careful allocation can be accomplished using the external EEPROM to load the appropriate values into the MDS105 configuration registers. The Low-Drop Precedence Buffer Threshold (LPBT) register assures that traffic designated as low-drop actually receives reserved buffer space. The designer can set the minimum number of buffers reserved for low-drop unicast traffic, by setting this register with a value between 0 and 255. Unreserved buffers are treated as shared, and are accessible to all types of incoming traffic. To set the maximum number of buffers permitted for all multicast packets, use the Multicast Buffer Control Register (MBCR). Unlike the LPBT register, the MBCR register does not define a reserved area of buffer memory, but instead provides a bound on the number of multicast packets that can be buffered at any one time. During operation the MDS105 will continuously monitor the amount of frame buffer memory that is available, and when the unused buffer space falls below a designer configurable threshold, the MDS105 will initiate flow control if enabled or WRED if not. This threshold is set using the FCB Buffer Low Threshold (FCBST) register. 5.0 Virtual LANs The MDS105 provides the designer the ability to define a single port-based Virtual LAN (VLAN) for each of the five ports. This VLAN is individually defined for each port using the Port Control Registers (ECR1Px[6:4]). Bits [6:4] allow the designer to define a VLAN ID (value between 0 – 3) for each port. When packets arrive at an input of the MDS105, the search engine will determine the VLAN ID for that port, and then determine which of the other ports are also members of that VLAN by matching their assigned VLAN ID values. The packet will then be transmitted to each port with the same VLAN ID as the source port. 6.0 Port Trunking Port trunking allows the designer to configure the MDS105, such that ports 0 and 1 are defined as a single logical port. This provides a 200 Mbps link to a switch or server utilizing two 100 Mbps ports in parallel. Ports 0 and 1 can be trunked by pulling the TRUNK_EN pin to the high state. In this mode, the source MAC addresses of all packets received from the trunk are checked against the MCT database to ensure that they have a port ID of 0 or 1. Packets that have a port ID other than 0 and 1 will cause the MDS105 to learn the new MAC address for this port change. On transmission, the trunk port is determined by hashing the source and destination MAC addresses. This provides a mapping between each MAC address and an associated trunk port. Subsequent packets with the same MAC address will always utilize the same trunk port. The MDS105 also provides a safe fail-over mode for port trunking. If one of the two ports goes down, as identified by the port’s link status signal, then the MDS105 will switch all traffic over to the remaining port in the trunk. Thus, the trunk link is maintained, albeit at a lower effective bandwidth. 11 Zarlink Semiconductor Inc. MDS105 7.0 Data Sheet Port Mirroring Utilizing the 4 port mirroring control pins provides the ability to enable or disable port mirroring, select which of the remaining 3 ports is to be mirrored, and choose whether the receive or transmit data is being mirrored. The control for this function is shown in the following table. Mirrored Port Mirror_Control [3] Mirror_Control [2] Mirror_Control [1] Mirror_Control [0] Port 0 RX 1 0 0 0 Port 0 TX 0 0 0 0 Port 1 RX 1 0 0 1 Port 1 TX 0 0 0 1 Port 2 RX 1 1 1 0 Port 2 TX 0 1 1 0 Disabled 0/1 1 1 1 Table 2 - Port Mirroring Configuration When enabled, port mirroring will allow the user to monitor traffic going through the switch on output Port 3. If the port mirroring control pins MIR_CTL[3:0] are left floating, the MDS105 will operate with the port mirroring function disabled. When port mirroring is enabled, the user must configure Port 3 to operate in the same mode as the port it is mirroring (autonegotiation, duplex, speed, flow control). 8.0 Power Saving Mode in MAC The MDS105 was designed to be power efficient. When the internal MAC sections detect that the external port is not receiving or transmitting packets, it will shut off and conserve power. When new packet data is loaded into the output transmit FIFO of a MAC in power saving mode, the MAC will return to life and begin operating immediately. When the MAC is in power saving mode and new packet data is received on the RMII, the MAC will return to life and receive data normally into the receive FIFO. This wakeup occurs when the MAC sees the Carrier Sense Data Valid (CRS_DV) signal asserted. Using this method, the switch will turn off all MAC sections during periods when there is no network activity (at night, for example), and save power. For large networks this power savings could be large. To achieve the maximum power efficiency, the designer should use a physical layer transceiver that utilizes “Wake-On-LAN” technology. 9.0 EEPROM I2C Interface A simple 2 wire serial interface is provided to allow the configuration of the MDS105 from an external EEPROM. The MDS105 utilizes a 1 K bit EEPROM with an I2C interface. 12 Zarlink Semiconductor Inc. MDS105 10.0 Data Sheet Management Interface The MDS105 uses a standard parallel port interface to provide external CPU access to the internal registers. This parallel interface is composed of 3 pins: DATA0, STROBE, and ACK. The DATA0 pin provides the address and data content input to the MDS105, while the ACK pin provides the corresponding output to the external CPU. The STROBE pin is provided as the clock for both serial data streams. Any of the MDS105 internal registers can be modified through this parallel port interface1. Figure 3 - Write Command Figure 4 - Read Command Each management interface transfer consists of four parts: 1. A START pulse – occurs when DATA is sampled high when STROBE is rising followed by DATA being sampled low when STROBE falls. 2. Register address strobed into DATA0 pin, using the high level of the STROBE pin. 3. Either a read or write command (see waveforms above). 4. Data to be written provided on DATA0, or data to be read provided on ACK. Any command can be aborted in the middle by sending an ABORT pulse to the MDS105. An ABORT pulse occurs when DATA is sampled low and STROBE is rising, followed by DATA being sampled high when STROBE falls. 1. The 3-bit parallel interface is not “parallel” in the usual sense of the word; it is actually a synchronous serial architecture. However, the MDS105 management interface adheres to IEEE 1284 parallel port standards. 13 Zarlink Semiconductor Inc. MDS105 11.0 Data Sheet Configuration Register Definitions The MDS105 registers can be accessed via the parallel interface and/or the I2C interface. Some registers are only accessible through the parallel interface. The access method for each register is listed in the individual register definitions. Each register is 8 bits wide. 11.1 GCR - Global Control Register • Access: parallel interface, Write Only • Address: h30 11.2 Bit 0 Save configuration into EEPROM Write '1' followed by a '0' (Default = 0) Bit 1 Save configuration into EEPROM and reset system Write '1' (self-clearing due to reset) (Default = 0) Bit 2 Start Built-In Self-Test (BIST) Write '1' followed by a '0' (Default = 0) Bit 3 Reset system Write '1' (self-clearing due to reset) (Default = 0) Bit [7:4] Reserved DCR - Device Status and Signature Register • Access: parallel interface, Read Only • Address: h31 Bit 0 Busy writing configuration from I2C 1: Activity 0: No Activity Bit 1 Busy reading configuration from I2C 1: Activity 0: No Activity Bit 2 Built-In Self-Test (BIST) in progress 1: BIST In-Progress 0: Normal Mode Bit 3 RAM error during BIST 1: RAM Error 0: No Error Bits [5:4] Reserved Bits [7:6] Revision number 00: Initial Silicon 01: Second Silicon 14 Zarlink Semiconductor Inc. MDS105 11.3 Data Sheet DA – DA Register • Access: parallel interface, Read Only • Address: h36 Returns 8 bit value DA (hexadecimal) if the parallel port connection is good. Otherwise, returns some other value indicating failure. 11.4 MBCR – Multicast Buffer Control Register • Access: parallel interface and I2C, Read/Write • Address: h00 Bit [7:0] 11.5 MAX_CNT_LMT Maximum number of multicast frames allowed to be buffered inside the device at any one time (Default = 80) FCBST – FCB Buffer Low Threshold • Access: parallel interface and I2C, Read/Write • Address: h01 Bits [5:0] BUF_LOW_TH Buffer Low Threshold – the number of free buffers below which flow control or WRED is triggered (Default = 3F) Bit 6 Use IP precedence subfield (TOS[0:2]) for Transmission Priority (Default = 0) Bit 7 Use IP precedence subfield (TOS[0:2]) for Drop Level (Default = 0) Note that, for Bits 6 and 7, Default = 0 means to use TOS[3:5]. 11.6 LPBT – Low Drop Precedence Buffer Threshold • Access: parallel interface and I2C, Read/Write • Address: h02 Bits [7:0] LOW_DROP_CNT Number of frame buffers reserved for low-drop traffic 15 Zarlink Semiconductor Inc. (Default 3F) MDS105 11.7 FCR – Flooding Control Register • Access: parallel interface and I2C, Read/Write • Address: h03 11.8 Bits [3:0] U2MR Maximum number of flooded frames allowed within any time interval indicated by TimeBase bits (violations are discarded) (Default = 8) Bits [6:4] TimeBase 000 = 100 µs 001 = 200 µs 010 = 400 µs 011 = 800 µs 100 = 1.6 µs 101 = 3.2 µs 110 = 6.4 µs 111 = 100 µs (Default = 000) Bit 7 USE_TOS Use TOS instead of VLAN priority for IP packet (Default = 0) AVTCL – VLAN TYPE CODE REGISTER LOW • Access: parallel interface and I2C, Read/Write • Address: h04 Bit [7:0] 11.9 VLANType_LOW Lower 8 bits of VLAN type code (Default = 00) AVTCH – VLAN Type Code Register High • Access: parallel interface and I2C, Read/Write • Address: h05 Bit [7:0] 11.10 Data Sheet VLANType_HIGH Upper 8 bits of VLAN type code (Default 81) AVPM – VLAN Priority Map • Access: parallel interface and I2 C, Read/Write • Address: h06 Map VLAN tag into 2 transmit queues (0 = low priority, 1 = high priority) Bit 0 Mapped priority of tag value 0 (Default 0) Bit 1 Mapped priority of tag value 1 (Default 0) Bit 2 Mapped priority of tag value 2 (Default 0) Bit 3 Mapped priority of tag value 3 (Default 0) Bit 4 Mapped priority of tag value 4 (Default 0) Bit 5 Mapped priority of tag value 5 (Default 0) Bit 6 Mapped priority of tag value 6 (Default 0) Bit 7 Mapped priority of tag value 7 (Default 0) 16 Zarlink Semiconductor Inc. MDS105 11.11 Data Sheet AVDM – VLAN Discard Map • Access: parallel interface and I2C, Read/Write • Address: h07 Map VLAN tag into frame discard levels (0 = low drop, 1 = high drop). 11.12 Bit 0 Frame discard for tag value 0 (Default 0) Bit 1 Frame discard for tag value 1 (Default 0) Bit 2 Frame discard for tag value 2 (Default 0) Bit 3 Frame discard for tag value 3 (Default 0) Bit 4 Frame discard for tag value 4 (Default 0) Bit 5 Frame discard for tag value 5 (Default 0) Bit 6 Frame discard for tag value 6 (Default 0) Bit 7 Frame discard for tag value 7 (Default 0) TOSPM – TOS Priority Map • Access: parallel interface and I2C, Read/Write • Address: h08 Map TOS field in IP packet into 2 transmit queues (0 = low priority, 1 = high priority). Bit 0 Mapped priority when TOS is 0 (Default 0) 11 Bit 1 Mapped priority when TOS is Bit 2 Mapped priority when TOS is 2 (Default 0) Bit 3 Mapped priority when TOS is 3 (Default 0) Bit 4 Mapped priority when TOS is 4 (Default 0) Bit 5 Mapped priority when TOS is 5 (Default 0) Bit 6 Mapped priority when TOS is 6 (Default 0) Bit 7 Mapped priority when TOS is 7 (Default 0) (Default 0) 1. TOS = 1 means the appropriate 3 bit TOS subfield is “001. 11.13 PTPRI – Port Priority • Access: parallel interface and I2C, Read/Write • Address: h09 Enable and configure port-based priorities for Ports 0, and 1 Bit 0 EN0 Port 0: Enable; 1 = enabled (Default 0) Bit 1 P0 Port 0: Priority; 1 = high, 0 = low (Default 0) Bit 2 EN1 Port 1: Enable; 1 = enabled (Default 0) Bit 3 P0 Port 1: Priority; 1 = high, 0 = low (Default 0) Bit 7:4 Reserved 17 Zarlink Semiconductor Inc. MDS105 11.14 Data Sheet TOSDM – TOS Discard Map • Access: parallel interface and I2C, Read/Write • Address: h0A Map TOS into frame discard levels (0 = low-drop, 1 = high-drop). 11.15 Bit 0 Frame discard when TOS is 0 (Default 0) Bit 1 Frame discard when TOS is 1 (Default 0) Bit 2 Frame discard when TOS is 2 (Default 0) Bit 3 Frame discard when TOS is 3 (Default 0) Bit 4 Frame discard when TOS is 4 (Default 0) Bit 5 Frame discard when TOS is 5 (Default 0) Bit 6 Frame discard when TOS is 6 (Default 0) Bit 7 Frame discard when TOS is 7 (Default 0) AXSC – Transmission Scheduling Control Register • Access: parallel interface and I2C, Read/Write • Address: h0B 11.16 Bits [3:0] Transmission Queue Service Weight for high priority queue (Default F) Bit [5] Global Quality of Service Enable (Default 0) Bit [6] Global Flow Control Disable – if 1, flow control is disabled globally; if 0, each port’s flow control settings are separately configurable (Default 0) Bit [7] Half Duplex Priority Enable – if 0, priority is disabled for all half duplex ports; if 1, priority is enabled unless AXSC[5] = 0 (Default 0) MII_OP0 – MII Register Option 0 • Access by parallel interface and I2C, Read/Write • Address: h0C Permits a non-standard address for the Phy Status Register. When low and high Address bytes are 0, the MDS108 will use the standard address. Bit [7:0] Low order address byte (Default 00) 18 Zarlink Semiconductor Inc. MDS105 11.17 MII_OP1 – MII Register Option 1 • Access: parallel interface and I2C, Read/Write • Address: h0D Bit [7:0] 11.18 High order address byte Access: parallel interface and I2C, Read/Write • Address: h0E Bit [7:0] Low byte of the MAC address aging timer (Default 25) AGETIME_HIGH – MAC Address Aging Timer High • Access: parallel interface and I2C, Read/Write • Address: h0F Bit [7:0] 11.20 (Default 00) AGETIME_LOW – MAC Address Aging Timer Low • 11.19 Data Sheet High byte of the MAC address aging timer. (Default 01) The aging time is based on the following formula: {AGETIME_HIGH, AGETIME_LOW} x 1024 ms The default setting provides a 300 second aging time. ECR1P0 – Port 0 Control Register • Access: parallel interface and I2C, Read/Write • Address: h10 Bits [3:0] Port Mode (Default 0000) Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Autonegotiate and advertise based on Bits [2:0] Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [0] 1 – Flow Control Off 0 – Flow Control On Bits [6:4] PVID Bit [7] Reserved Port-based VLAN ID 19 Zarlink Semiconductor Inc. (Default 000) MDS105 11.21 ECR1P1 – Port 1 Control Register • Access: parallel interface and I2C, Read/Write • Address: h11 Bits [3:0] 11.22 Port Mode (Default 0000) Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Autonegotiate and advertise based on Bits [2:0] Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [0] 1 – Flow Control Off 0 – Flow Control On Bits [6:4] PVID Bit [7] Reserved Port-based VLAN ID (Default 000) ECR1P2 – Port 2 Control Register • Access: parallel interface and I2C, Read/Write • Address: h12 Bits [3:0] 11.23 Data Sheet Port Mode (Default 0000) Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Autonegotiate and advertise based on Bits [2:0] Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [0] 1 – Flow Control Off 0 – Flow Control On Bits [6:4] PVID Bit [7] Reserved Port-based VLAN ID (Default 000) ECR1P3 – Port 3 Control Register • Access: parallel interface and I2C, Read/Write • Address: h13 Bits [3:0] Port Mode (Default 0000) 20 Zarlink Semiconductor Inc. MDS105 11.24 Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Autonegotiate and advertise based on Bits [2:0] Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [0] 1 – Flow Control Off 0 – Flow Control On Bits [6:4] PVID Bit [7] Reserved Port-based VLAN ID (Default 000) ECR1P4 – Port 4 Control Register • Access: parallel interface and I2C, Read/Write • Address: h14 Bits [3:0] 11.25 Data Sheet Port Mode (Default 0000) Bit [3] 1 – Force configuration based on Bits [2:0] 0 – Autonegotiate and advertise based on Bits [2:0] Bit [2] 1 – 10 Mbps 0 – 100 Mbps Bit [1] 1 – Half Duplex 0 – Full Duplex Bit [0] 1 – Flow Control Off 0 – Flow Control On Bits [6:4] PVID Bit [7] Reserved Port-based VLAN ID (Default 000) FC_0 – Flow Control Byte 0 • Access: parallel interface and I2C, Read/Write • Address: h19 The flow control hold time parameter is the length of time a flow control message is effectual (i.e. halts incoming traffic) after being received. The hold time is measured in units of “slots,” the time it takes to transmit 64 bytes at wire-speed. The default setting is 32 slots, or for a 100 Mbps port, approximately 164 ms. Bits [7:0] Flow control hold time byte 0 (Default FF) 21 Zarlink Semiconductor Inc. MDS105 11.26 FC_1 – Flow Control Byte 1 • Access: parallel interface and I2C, Read/Write • Address: h1A Bits [7:0] 11.27 Flow control hold time byte 1 Access: parallel interface and I2C, Read/Write • Address: h1B Bits [7:0] Flow control frame CRC byte 0 Access: parallel interface and I2C, Read/Write • Address: h1C Bits [7:0] Flow control frame CRC byte 1 Access: parallel interface and I2C, Read/Write • Address: h1D Bits [7:0] Flow control frame CRC byte 2 (Default 99) FC_5 – Flow Control CRC Byte 3 • Access: parallel interface and I2C, Read/Write • Address: h1E Bits [7:0] 11.31 (Default 8E) FC_4 – Flow Control CRC Byte 2 • 11.30 (Default 96) FC_3 – Flow Control CRC Byte 1 • 11.29 (Default 00) FC_2 – Flow Control CRC Byte 0 • 11.28 Data Sheet Flow control frame CRC byte 3 (Default 9A) CHECKSUM - EEPROM Checksum • Access: parallel interface and I2C, Read/Write • Address: h24 The calculation is [0x100 - ((sum of registers 0x00~0x23) & 0xFF)]. For example, based on the default register settings, the CHECKSUM value would be 0xEE. Bits [7:0] Checksum (Default 00) 22 Zarlink Semiconductor Inc. MDS105 12.0 Data Sheet MDS105 Pin Descriptions Note: # I S O OD I/O SL D U 55V Active low signal Input signal Input signal with Schmitt-Trigger Output signal Open-Drain driver Input & Output signal Slew Rate Controlled Pulldown Pullup Tolerance Pin No(s). Symbol Type Name & Functions Frame Buffer Memory Interface 201, 200, 199, 197, 196, 195, 193, 192, 191, 190, 188, 187, 186, 185, 183, 182, 181, 179, 178, 177, 176, 174, 173, 172, 170, 169, 168, 167, 165, 164, 163, 161 L_D[31:0] I/O, U, SL Databus to Frame Buffer Memory 203, 151, 158, 160, 10, 9, 8, 6, 5, 4, 2, 1, 208, 206, 205, 204, 150 L_A[18:2] I/O, U, SL Address pins for buffer memory 153 L_CLK O Frame Buffer Memory Clock 155 L_WE# O, SL Frame Buffer Memory Write Enable 156 L_OE# O Frame Buffer Memory Output Enable 157 L_ADSC# O, SL Frame Buffer Memory Address Status Control 120 M_MDC O MII Management Data Clock 122 M_MDIO I/O, U MII Management Data I/O I2C Data Clock MII Management Interface I 2C Interface (Serial EEPROM Interface) 123 SCL O, U, 5 124 SDA I/O, U, OD, 5 I2C Data I/O Parallel Port Management Interface 127 STROBE I, U, S, 5 Strobe Pin 128 DATA0 I, U, 5 Data Pin 129 ACK O, U, OD, 5 Acknowledge Pin 24, 23 M0_RXD[1:0] I, U Port 0 Receive Data 22 M0_CRS_DV I, D Port 0 Carrier Sense and Data Valid 21, 20 M0_TXD[1:0] O Port 0 Transmit Data 19 M0_TXEN O Port 0 Transmit Enable M1_RXD[1:0] I, U Port 1 Receive Data Port 0 RMII Interface Port 1 RMII Interface 31, 30 23 Zarlink Semiconductor Inc. MDS105 Pin No(s). Symbol Type Data Sheet Name & Functions 29 M1_CRS_DV I, D Port 1 Carrier Sense and Data Valid 28, 27 M1_TXD[1:0] O Port 1 Transmit Data 26 M1_TXEN O Port 1 Transmit Enable 79, 78 M2_RXD[1:0] I, U Port 2 Receive Data 77 M2_CRS_DV I, D Port 2 Carrier Sense and Data Valid 76, 75 M2_TXD[1:0] O Port 2 Transmit Data 74 M2_TXEN O Port 2 Transmit Enable 86, 85 M3_RXD[1:0] I, U Port 3 Receive Data 84 M3_CRS_DV I, D Port 3 Carrier Sense and Data Valid 83, 82 M3_TXD[1:0] O Port 3 Transmit Data 81 M3_TXEN O Port 3 Transmit Enable 105, 104, 103, 102 M4_RXD[3:0] I, U Port 4 Receive Data 113, 112, 111, 110 M4_TXD[3;0] O Port 4 Transmit Data 109 M4_TXEN O Port 4 Transmit Enable 97 M4_RXDV I, D Port 4 Receive Data Valid 100 M4_RXCLK I, U Port 4 Receive Clock 107 M4_TXCLK I/O, U Port 4 Transmit Clock 114 M4_LINK I, U Port 4 Link Status 116 M4_SPEED I/O, U Port 4 Speed Select (100 Mb = 1) 115 M4_DUPLEX I, U Port 4 Full-Duplex Select (half-duplex = 0) 98 M4_COL I, U Port 4 Collision Detect 102 S4_RXD I, U Port 4 Serial Receive Data 100 S4_RXCLK I, U Port 4 Serial Receive Clock Port 2 RMII Interface Port 3 RMII Interface Port 4 MII Interface Port 4 Serial Interface 97 S4_CRS_DV I, D Port 4 Serial Carrier Sense and Data Valid 110 S4_TXD O Port 4 Serial Transmit Data 107 S4_TXCLK I Port 4 Serial Transmit Clock 109 S4_TXEN O Port 4 Serial Transmit Enable 98 S4_COL I, U Port 4 Serial Collision Detect 114 S4_LINK I, U Port 4 Link Status 115 S4_DUPLEX I, U Port 4 Full-Duplex Select (half-duplex = 0) Miscellaneous Control Pins 95 M_CLK I Reference RMII Clock 118 M4_REFCLK O, U Port 4 Reference Clock (M_CLK/2) 148 SCLK I System Clock (25 - 50 MHz) 125 TEST# I, U Manufacturing Pin Leave as No Connect (NC) 24 Zarlink Semiconductor Inc. MDS105 Pin No(s). Symbol Type Data Sheet Name & Functions 126 TRUNK_EN I, D Port Trunking Enable 146, 145, 144, 143 MIR_CTL[3:0] I/O, U Port Mirroring Control 142 RESIN# I, S Reset Pin 141 RESETOUT# O PHY Reset Pin 139 TMODE# I/O, U Manufacturing Pin. Puts device into test mode for ATE test. Leave as No Connect (NC). 138, 137, 136, 135 TSTOUT[7:4] O Test Outputs 134, 133, 132, 131 TSTOUT[3:0] I/O, U Test Outputs Test Pins NC Pins 12, 13, 14, 15, 16, 17, 33, 34, 35, 36, 37, 38, 40, 41, 42, 43, 44, 45, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 60, 61, 62, 63, 64, 65, 67, 68, 69, 70, 71, 72, 88, 89, 90, 91, 92, 93 N/C Reserved No Connect Power Pins 3, 39, 73, 96, 130, 159, 184 VDD (Core) Input +3.3 Volt DC Supply for Core Logic (7 pins) 11, 25, 59, 87, 101, 108, 119, 147, 152, 166, 175, 194, 202 VDD Input +3.3 Volt DC Supply for I/O Pads (13 pins) 18, 46, 80, 106, 140, 171, 198 VSS (Core) Input Ground for Core Logic (7 pins) 7, 32, 66, 94, 99, 117, 121, 149, 154, 162, 180, 189, 207 VSS Input Ground for I/O Pads (13 pins) 25 Zarlink Semiconductor Inc. MDS105 12.1 Data Sheet Strap Options The Strap options are relevant during the initial power-on period, when reset is asserted. During reset, the MDS105 will examine the boot strap address pin to determine its value and modify the internal configuration of the chip accordingly. “1” means Pull-up “0” means Pull-down with an external 1 K Ohm Default value is 1, (all boot strap pins have internal pull-up resistor). Pin No(s). Symbol Name & Functions Boot Strap Pins 206 (L_A[5]) Memory Size 1 - Memory size = 256 KB 0 - Memory size = 512 KB 208 (L_A [6]) EEPROM 1 - NO EEPROM Installed 0 - EEPROM Installed1 151 (L_A[17]) Port 4 MII/Serial 1 - MII Mode for port 4 0 - Serial mode for port 4 150 (L_A[2]) Link Polarity Link Polarity for serial interface 1 - Active Low 0 - Active High 204 (L_A[3]) FDX Polarity Full/Half Duplex Polarity for serial interface 1 - Active Low 0 - Active High 205 (L_A[4]) SPD100 Polarity Speed polarity for serial interface 1 - Active Low 0 - Active High 133 (TST[2]) SBRAM Self Test For Board/System Manufacturing Test2 1 - Disable 0 - Enable 1. If the MDS105 is configured from EEPROM preset (L_A[6] pulled down at reset), it will try to load its configuration from the EEPROM. If the EEPROM is blank or not preset, it will not boot up. The parallel port can be used to program the EEPROM at any time. 2. During normal power-up, the MDS105 will run through an external SBRAM memory test to ensure that there are no memory interface problems. If a problem is detected, the chip will stop functioning. To facilitate board debug in the event that a system stops functioning, the MSD105 can be put into a continuous SBRAM self test mode to allow an operator to determine if there are stuck pins in the memory interface (using network analyzer). 26 Zarlink Semiconductor Inc. MDS105 13.0 Characteristics and Timing 13.1 Absolute Maximum Rating Storage Temperature -65°C to +150°C Operating Temperature -40°C to +85°C Maximum Junction Temperature +125°C Supply Voltage VDD with Respect to VSS +3.0 V to +3.6 V Voltage on 5V Tolerant Input Pins -0.5 V to (VDD +3.3 V) Voltage on Other Pins -0.5 V to (VDD +0.3 V) Data Sheet Caution: Stresses above those listed may cause permanent device failure. Functionality at or above these limits is not implied. Exposure to the absolute Maximum Ratings for extended Ratings for extended periods may affect device reliability. 13.2 DC Electrical Characteristics VDD = 3.0 V to 3.6 V (3.3v +/- 10%) TAMBIENT = -40°C to +85°C 13.3 Recommended Operating Conditions Symbol Parameter Description fOSC Frequency of Operation IDD VOH VOL Supply Current - @ 50 MHz (VDD = 3.3 V) Output High Voltage (CMOS) Min. Typ. Max. Unit 25 50 80 MHz TBD mA 2.4 Output Low Voltage (CMOS) V 0.4 V VDD + 2.0 V Input Low Voltage (TTL 5 V tolerant) 0.8 V IIL Input Leakage Current (0.1 V < VIN < VDD) (all pins except those with internal pull-up/ pulldown resistors) 10 µA IOL Output Leakage Current (0.1 V < VOUT < VDD) 10 µA CIN Input Capacitance 5 pF Output Capacitance 5 pF I/O Capacitance 7 pF VIH-TTL Input High Voltage (TTL 5 V tolerant) VIL-TTL COUT CI/O 2.0 θja Thermal resistance with 0 air flow 29.7 C/W θja Thermal resistance with 1 m/s air flow 28.8 C/W θja Thermal resistance with 2 m/s air flow 26.8 C/W θjc Thermal resistance between junction and case 12.6 C/W 27 Zarlink Semiconductor Inc. MDS105 13.4 Data Sheet Clock Frequency Specifications Symbol Parameter (Hz) C1 SCLK - Core System Clock Input 50 M C2 M_CLK - RMII Port Clock 50 M C3 M4_REFCLK - MII Reference Clock 25 M C4 L_CLK - Frame Buffer Memory Clock 50 M C5 M_MDC - MII Management Data Clock L_CLK = SCLK 1.56 M M_MDC = SCLK/32 50 K SCL = M_CLK/1000 2 C6 Note: SCL - I C Data Clock Suggestion Clock rate for various configurations: Input Configuration Port 0-3 Port 4 Output SCLK M_CLK (RMII) L_CLK M_MDC SCL 10 M RMII 10/100 M MII 25 M 50 M =SCLK =SCLK/32 50 K 100 M RMII Not Used 50 M 50 M =SCLK =SCLK/32 50 K 100 M RMII 10/100 M MII 50 M 50 M =SCLK =SCLK/32 50 K 28 Zarlink Semiconductor Inc. MDS105 14.0 AC Timing Characteristics 14.1 Frame Buffer Memory Interface: Data Sheet L_D[31:0] Figure 5 - Frame Buffer Memory Interface Timing Symbol 50 MHz Parameter Min. (ns) Max. (ns) Note L1 L_D[31:0] input setup time 5 L2 L_D[31:0] input hold time 0 L3 L_D[31:0] output valid delay 1 8 CL = 30 pF L4 L_A[18:2] output valid delay 1 8 CL = 50 pF L6 L_ADSC# output valid delay 1 8 CL = 50 pF L8 L_WE# output valid delay 1 8 CL = 30 pF L9 L_OE# output valid delay 1 8 CL = 30 pF Table 3 - Frame Buffer Memory Interface Timin 29 Zarlink Semiconductor Inc. MDS105 14.2 Data Sheet RMII Timing Requirements Symbol 50 MHz Parameter Min. (ns) Note Max. (ns) M1 M_CLK Reference Input Clock M2 M[3:0]_RXD[1:0] input setup time 4 M3 M[3:0]_RXD[1:0] input hold time 1 M4 M[3:0]_CRS_DV input setup time 4 M5 M[3:0]_TXEN output delay time 1 11 CL = 30 pF M6 M[3:0]_TXD[1:0] output delay time 1 11 CL = 30 pF M7 M[3:0]_LINK input setup time 4 Table 4 - RMII Timing Requirements 14.3 MII Timing Requirements Figure 6 - Transmit Timing Symbol Time Parameter Min. Max. Unit 1 M4_TXCLK rise to M4_TXD[3:0] inactive delay 5 20 ns 2 M4_TXCLK rise to M4_TXD[3:0] active delay 5 20 ns 3 M4_TXCLK rise to M4_TXEN active delay 5 20 ns 4 M4_TXCLK rise of last M4_TXD bit to M4_TXEN inactive delay 5 20 ns 5 M4_TXCLK High wide 25 Inf. ns 6 M4_TXCLK Low wide 25 Inf. ns M4_TXCLK input rise time require 5 ns M4_TXCLK input fall time require 5 ns *Inf. - infinite Table 5 - Transmit Timing Requirements 30 Zarlink Semiconductor Inc. MDS105 Data Sheet M4_RXCLK M4_RXD[3:0] M4_RXDV Figure 7 - Receive Timing Symbol Time Parameter Min. 1 M4_RXD[3:0] Low input setup time 2 M4_RXD[3:0] Low input hold time 3 M4_RXD[3:0] High input setup time 4 M4_RXD[3:0] High input hold time 5 M4_RXDV Low input setup time 6 M4_RXDV Low input hold time 7 M4_RXDV High input setup time 8 M4_RXDV High input hold time 9 M4_RXCLK High wide 10 M4_RXCLK Low wide Max. 10 Unit ns 5 10 ns ns 5 10 ns ns 5 10 ns ns 5 ns 25 Inf. ns 25 Inf. ns M4_RXCLK input rise time require 5 ns M4_RXCLK input fall time require 5 ns *Inf. - infinite Table 6 - Receive Timing Requirements 31 Zarlink Semiconductor Inc. MDS105 14.4 Data Sheet Port 4 Serial Mode AC Timing Figure 8 - Transmit Timing Symbol Time Parameter Min. Max. Unit 1 S4_TXCLK rise to S4_TXD inactive delay 5 20 ns 2 S4_TXCLK rise to S4_TXD active delay 5 20 ns 3 S4_TXCLK rise to S4_TXEN active delay 5 20 ns 4 S4_TXCLK rise of Last S4_TXD bit to S4_TXEN inactive delay 5 20 ns 5 S4_TXCLK High wide 25 Inf. ns 6 S4_TXCLK Low wide 25 Inf. ns S4_TXCLK input rise time require 5 ns S4_TXCLK input fall time require 5 ns *Inf. - infinite Table 7 - Transmit Timing Requirements 32 Zarlink Semiconductor Inc. MDS105 Data Sheet Figure 9 - Receive Timing Symbol Time Parameter Min. 1 S4_RXD Low input setup time 2 S4_RXD Low input hold time 3 S4_RXD High input setup time 4 S4_RXD High input hold time 5 S4_CRS_DV Low input setup time 6 S4_CRS_DV Low input hold time 7 S4_CRS_DV High input setup time 8 S4_CRS_DV High input hold time 9 S4_RXCLK Hi wide 10 S4_RXCLK Low wide Max. 10 Unit ns 5 10 ns ns 5 10 ns ns 5 10 ns ns 5 ns 25 Inf. ns 25 Inf. ns S4_RXCLK input rise time require 5 ns S4_RXCLK input fall time require 5 ns *Inf. - infinite Table 8 - Receive Timing Requirements 33 Zarlink Semiconductor Inc. D D1 = 0°-7° A E1 A2 E A1 L INDEX CORNER PIN 1 Notes: 1. Pin 1 indicator may be a corner chamfer, dot or both. 2. Controlling dimensions are in millimeters. 3. The top package body size may be smaller than the bottom package body size by a max. of 0.15 mm. 4. Dimension D1 and E1 do not include mould protusion. Package Code c Zarlink Semiconductor 2003 All rights reserved. ISSUE ACN DATE APPRD. Previous package codes: For more information about all Zarlink products visit our Web Site at www.zarlink.com Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable. However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink. This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request. Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system conforms to the I2C Standard Specification as defined by Philips. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright Zarlink Semiconductor Inc. All Rights Reserved. TECHNICAL DOCUMENTATION - NOT FOR RESALE