ETC LBT-131

Photointerrupter
Model No: LBT-131
Features
˙Compact package based on the double-mold method.
˙High resolution (slit width = 0.5mm).
˙Gap between emitter and detector is 5.25mm.
Applications
˙Floppy disk drives
˙Printers
˙Cameras
Outline Dimensions (Unit: mm)
--1--
Letex Technology Corp.
Photointerrupter
Model No: LBT-131
Absolute Maximum Ratings (Ambient Temperature: 25℃)
Item
Symbol
Rating
Forward current
IF
50
Reverse voltage
VR
5
Input
Peak forward current
IFP
1
Power dissipation
Collector current
Collector-Emitter voltage
Output
Emitter-Collector voltage
Collector power dissipation
Storage Temperature
Operating Temperature
Soldering Temperature
Pd
Ic
Vceo
Veco
Pc
Tstg
Top
Tsol
Units
mA
V
A
75
50
30
5
100
-40 to +85
-25 to +85
260
Electrical Specifications (Ambient Temperature: 25℃)
Item
Symbol
MIN.
Forward voltage
VF
Reverse current
IR
Input
Peak wavelength
λp
View angle
2θ1/2
Dark current
Iceo
Output
C-E saturation voltage
Vce(sat)
Light current
Ic(on)
0.5
Leakage current
ILeak
Rise Time
tr
Speed
Fall Time
tf
--2--
TYP.
1.2
mW
mA
V
V
mW
℃
℃
℃
MAX.
1.4
10
940
35
100
0.4
1
5
5
Note
Tw=10μs,
t=10ms
5 seconds max.
Units
V
µA
nm
Deg.
nA
µA
mA
µA
µs
Conditions
IF=20mA
VR=5V
IF=20mA
Vce=20V
Ic=2mA, IB=0.1mA
Vce=5V
IF=20mA
Vce=5V
Ic=1mA
RL=1KΩ
Letex Technology Corp.
Photointerrupter
Reference Data
Power dissipation Vs.
Ambient temperature
Forward current Vs.
Ambient temperature
Peak forward current Vs.
Duty ratio
60
2000
40
30
20
Peak forward current ( mA )
100
Power dissipation (mW)
Forward current (mA)
50
80
60
40
10
20
0
0
Pulse width 100us
Ta = 25℃
1000
500
200
100
50
20
-30
0
25
50
75
100
125
10
-25
0
75
100
-3
125
5 10
50℃
Ta = 25℃
20
10
5
0
2
5 10
50mA
10
Collector current (mA)
Collector current (mA)
25℃
50
5 10
12
0℃
100
-1
2
Collector current Vs.
Collector-Emitter voltage
10
25℃
5 10
Collector current Vs.
Forward current
Vce = 5V
Ta = 25℃
Ta = 75℃
200
-2
2
Duty ratio
12
500
Forward current (mA)
50
Ambient temperature (℃)
Ambient temperature (℃)
Forward current Vs.
Forward voltage
25
8
6
4
2
40mA
8
30mA
6
20mA
4
IF=10mA
2
2
1
0
0.5
1.0
1.5
2.0
2.5
3.0
0
0
10
20
Forward voltage (V)
0
1
200
100
6
5
4
3
3
4
5
6
7
8
9
10
Collector dark current Vs.
Ambient temperature
10 -5
Vce = 2V
Ic = 2mA
Ta = 25℃
Vce = 20V
50
20
tf
10
5
tr
td
2
1
2
2
Collector-Emitter voltage (V)
500
Response time ( μ s)
Collector current (uA)
50
Response time Vs.
Load resistance
IF = 20mA
Vce = 5V
7
40
Forward current (mA)
Collector current Vs.
Ambient temperature
8
30
Collector dark current (A)
0
ts
0.5
1
10 -6
10 -7
10 -8
10 -9
10 -10
0.2
0
-25
0
25
50
75
0.1
0.03 0.05 0.1 0.2 0.5 1
100
10 -11
2
5
100
0.30
Relative collector current (%)
0.20
0.15
0.10
0.05
25
50
75
100
Test circuit for resopnse time
Vcc
IF = 20mA
Vce = 5V
Ta=25°
IF = 40mA
Ic=1mA
0.25
0
Ambient temperature (℃)
Relative collector current Vs.
Shield distance
C-E Saturation voltage Vs.
Ambient temperature
C-E Saturation voltage (V)
-25
Load resistance (k Ω )
Ambient temperature (℃)
0
-25
10
80
Input
RL
Input RD
Output
Output
10%
60
90%
40
20
0
0
25
50
75
100
-2 -1
0
1
2
-2 -1
0
1
--3--
2
Letex Technology Corp.