NEC D16311GC

DATA SHEET
SHEET
DATA
MOS INTEGRATED CIRCUIT
PD16311
1/8- to 1/16-DUTY FIPTM (VFD) CONTROLLER/DRIVER
The PD16311 is a FIP (Fluorescent Indicator Panel or Vacuum Fluorescent Display) controller/driver that is
driven on a 1/8- to 1/16 duty factor. It consists of 12 segment output lines, 8 grid output lines, 8 segment/grid output
drive lines, a display memory, a control circuit, and a key scan circuit. Serial data is input to the PD16311 through a
three-line serial interface. This FIP controller/driver is ideal as a peripheral device of a single-chip microcomputer.
FEATURES
• Many display modes (12-segment & 16-digit to 20-segment & 8-digit)
• Key scanning (12 4 matrices)
• Dimming circuit (eight steps)
• High-voltage output (VDD 35 V max).
• LED ports (5 chs., 20 mA max).
• General-purpose input port (4 bits)
• No external resistor necessary for driver outputs (P-ch open-drain + pull-down resistor output)
• Serial interface (CLK, STB, DIN, DOUT)
ORDERING INFORMATION
Part Number
Package
PD16311GC-AB6
52-pin plastic QFP ( 14)
Document No. IC-3306 (1st edition)
Date Published March 1997 P
Printed in Japan
©
1993
PD16311
BLOCK DIAGRAM
Command decoder
Dimming
circuit
Display memory
20 bit × 16 Word
Serial I/F
CLK
20
Segment driver
DOUT
20-bit output latch
DIN
12
Seg1
Seg12
8
STB
4
4-bit latch
SW1
to
SW4
4
16
VDD
(+5 V)
LED5
Seg13/Grid16
Seg20/Grid9
8
8
5-bit latch
LED1
2
8
Grid driver
Key data memory (4 × 12)
16-bit shift register
Timing generator
key scan
OSC
Key1
to
Key4
Data selector
R
Segment/grid
driver
VDD
VSS
VEE
(0 V) (−30 V)
Grid1
Grid8
PD16311
40 Grid5
41 Grid4
42 Grid3
43 Grid2
44 Grid1
45 VDD
46 LED5
47 LED4
48 LED3
49 LED2
50 LED1
51 VSS
52 OSC
PIN CONFIGURATION (Top View)
5
35 Seg19/Grid10
DIN
6
34 VEE
IC
7
33 VDD
CLK
8
32 Seg18/Grid11
STB
9
31 Seg17/Grid12
KEY1 10
30 Seg16/Grid13
KEY2 11
29 Seg15/Grid14
KEY3 12
28 Seg14/Grid15
KEY4 13
27 Seg13/Grid16
Seg12/KS12 26
DOUT
Seg11/KS11 25
36 Seg20/Grid9
Seg10/KS10 24
4
Seg9/KS9 23
SW4
Seg8/KS8 22
37 Grid8
Seg7/KS7 21
3
Seg6/KS6 20
SW3
Seg5/KS5 19
38 Grid7
Seg4/KS4 18
2
Seg3/KS3 17
SW2
Seg2/KS2 16
39 Grid6
Seg1/KS1 15
1
VDD 14
SW1
Use all the power pins. Leave the IC pin open.
3
PD16311
Pin Function
Pin No.
Symbol
6
DIN
5
9
Pin Name
Description
Data input
Inputs serial data at rising edge of shift clock, starting from lower
bit.
DOUT
Data output
Outputs serial data at falling edge of shift clock, starting from
lower bit. This is N-ch open-drain output pin.
STB
Strobe
Initializes serial interface at rising or falling edge to make
PD16311 waiting for reception of command. Data input after
STB has fallen is processed as command. While command data
is processed, current processing is stopped, and serial interface
is initialized. While STB is high, CLK is ignored.
4
8
CLK
Clock input
Reads serial data at rising edge, and outputs data at falling edge.
52
OSC
Oscillator pin
Connect resistor for determining oscillation frequency to this pin.
15 to 26
Seg1/KS1 to
Seg12/KS12
High-voltage output
(segment)
Segment output pins (Dual function as key source)
44 to 37
Grid1 to Grid6
High-voltage output (grid)
Grid output pins
27 to 32
35 to 36
Seg13/Grid16 to
Seg20/Grid9
High-voltage output
(segment/grid)
These pins are selectable for segment or grid output.
50 to 46
LED1 to LED5
LED output
CMOS output. +20 mA max.
10 to 13
Key1 to Key4
Key data input
Data input to these pins is latched at end of display cycle.
1 to 4
SW1 to SW4
Switch input
These pins constitute 4-bit general-purpose input port.
14, 33, 45
VDD
Logic power
5 V 10 %
51
VSS
Logic ground
Connect this pin to GND of system.
34
VEE
Pull-down level
VDD 35 V max.
7
IC
Internally connected
Be sure to leave this pin open (this pin is at VDD level).
PD16311
Display RAM Address and Display Mode
The display RAM stores the data transmitted from an external device to the PD16311 through the serial interface,
and is assigned addresses as follows, in units of 8 bits:
Seg1
Seg4
Seg8
Seg12
Seg16
Seg20
00 HL
00 HU
01 HL
01 HU
02 HL
DIG1
03 HL
03 HU
04 HL
04 HU
05 HL
DIG2
06 HL
06 HU
07 HL
07 HU
08 HL
DIG3
09 HL
09 HU
0 AHL
0 AHU
0 BHL
DIG4
0 CHL
0 CHU
0 DHL
0 DHU
0 EHL
DIG5
0 FHL
0 FHU
10 HL
10 HU
11 HL
DIG6
12 HL
12 HU
13 HL
13 HU
14 HL
DIG7
15 HL
15 HU
16 HL
16 HU
17 HL
DIG8
18 HL
18 HU
19 HL
19 HU
1 AHL
DIG9
1 BHL
1 BHU
1 CHL
1 CHU
1 DHL
DIG10
1 EHL
1 EHU
1 FHL
1 FHU
20 HL
DIG11
21 HL
21 HU
22 HL
22 HU
23 HL
DIG12
24 HL
24 HU
25 HL
25 HU
26 HL
DIG13
27 HL
27 HU
28 HL
28 HU
29 HL
DIG14
2 AHL
2 AHU
2 BHL
2 BHU
2 CHL
DIG15
2 DHL
2 DHU
2 EHL
2 EHU
2 FHL
DIG16
b0
b3 b4
b7
XX HL
XX HU
Lower 4 bits
Higher 4 bits
Only the lower 4 bits of the addresses assigned to Seg17 through Seg20 are valid, and the higher 4 bits are
ignored.
5
PD16311
Key Matrix and Key-Input Data Storage RAM
The key matrix is of 12 4 configuration, as shown below.
KEY1
KEY2
KEY3
Seg12/KS12
Seg11/KS11
Seg10/KS10
Seg9/KS9
Seg8/KS8
Seg7/KS7
Seg6/KS6
Seg5/KS5
Seg4/KS4
Seg3/KS3
Seg2/KS2
Seg1/KS1
KEY4
The data of each key is stored as illustrated below, and is read by a read command, starting from the least
significant bit.
KEY1…KEY4
KEY1…KEY4
Seg1/KS1
Seg2/KS2
Seg3/KS3
Seg4/KS4
Seg5/KS5
Seg6/KS6
Seg7/KS7
Seg8/KS8
Seg9/KS9
Seg10/KS10
Seg11/KS11
Seg12/KS12
b0------------ b3
b4 ------------b7
Reading sequence
When the most significant bit of data (Seg12 b7) has been read, the least significant bit of the next data (Seg1 b0) is
read.
LED Port
Data is written to the LED port by a write command, starting from the least significant bit of the port. When a bit of
this port is 0, the corresponding LED lights; when the bit is 1, the LED goes off. The data of bits 6 through 8 is
ignored.
MSB
−
LSB
−
−
b4
b3
b2
b1
b0
LED1
Don't care
LED2
LED3
LED4
LED5
On power application, all the LEDs remain dark.
6
PD16311
SW Data
The SW data is read by a read command, starting from the least significant bit. Bits 5 through 8 of the SW data
are 0.
MSB
0
LSB
0
0
0
b3
b2
b1
b0
SW1
SW2
SW3
SW4
Command
A command sets the display mode and status of the FIP driver.
The first 1 byte input to the PD16311 through the DIN pin after the STB pin has fallen is regarded as a command.
If STB is made high while a command/data is transmitted, serial communication is initialized, and the
command/data being transmitted is invalid (however, the command/data already transmitted remains valid).
(1) Display mode setting command
This command initializes the PD16311 and selects the number of segments and number of grids (1/8 to 1/16
duty, 12 segments to 20 segments).
When this command is executed, display is forcibly turned off, and key scanning is also stopped. To resume
display, a display ON command must be executed. If the same mode is selected, however, nothing is
performed.
MSB
0
LSB
0
−
−
Don't care
b3
b2
b1
b0
Selects display mode
0xxx : 8 digits, 20 segments
1000 : 9 digits, 19 segments
1001 : 10 digits, 18 segments
1010 : 11 digits, 17 segments
1011 : 12 digits, 16 segments
1100 : 13 digits, 15 segments
1101 : 14 digits, 14segments
1110 : 15 digits, 13 segments
1111 : 16 digits, 12 segments
On power application, the 16-digit, 12-segment mode is selected.
7
PD16311
(2) Data setting command
This command sets data write and data read modes.
MSB
0
LSB
1
−
−
b3
b2
b1
b0
Sets data write and read modes.
00 : Writes data to display memory.
01 : Writes data to LED port.
10 : Reads key data.
11 : Reads SW data.
Don't care
Sets address increment mode (display memory).
0 : Increments address after data has been written.
1 : Fixes address.
Sets test mode
0 : Normal operation
1 : Test mode
On power application, the normal operation mode and address increment mode are set.
(3) Address setting command
This command sets an address of the display memory.
MSB
1
LSB
1
b5
b4
b3
b2
b1
b0
Address (00H - 2FH)
If address 30H or higher is set, the data is ignored, until a correct address is set.
On power application, the address is set to 00H.
8
PD16311
(4) Display control command
MSB
1
LSB
0
−
−
b3
b2
b1
Don't care
b0
Sets dimming quantity.
000 : Sets pulse width to 1/16.
001 : Sets pulse width to 2/16.
010 : Sets pulse width to 4/16.
011 : Sets pulse width to 10/16.
100 : Sets pulse width to 11/16.
101 : Sets pulse width to 12/16.
110 : Sets pulse width to 13/16.
111 : Sets pulse width to 14/16.
Turns on/off display.
0 : Display off (key scan continues*)
1 : Display on
On power application, the 1/16-pulse width is set and the display is turned off.
*: On power application, key scanning is stopped.
9
PD16311
Key Scanning and Display Timing
TDISP = 500 µ s
SEG Output
DIG1
Key scan data
DIG2
DIG3
DIGn
G1
G2
1/16
TDISP
G3
Gn
1 frame = TDISP × (n + 1)
One cycle of key scanning consists of two frames, and data of 12 4 matrices is stored in RAM.
10
DIG1
PD16311
Serial Communication Format
Reception (command/data write)
If data is contiguous
STB
DIN
CLK
b0
b1
b2
1
2
3
b6
b7
7
8
Transmission (data read)
STB
DIN
CLK
b0
1
b1
2
b2
3
b3
4
b4
5
b5
6
b6
7
b7
8
DOUT
tWAIT*
1
2
b0
Data reading command is set.
3
b1
b2
4
b3
5
6
b4
b5
Data reading starts.
Because the DOUT pin is an N-ch, open-drain output pin, be sure to connect an external pull-up resistor to this pin
(1 k to 10 k).
*: When data is read, a wait time tWAIT of 1 s is necessary since the rising of the eighth clock that has set the
command, until the falling of the first clock that has read the data.
11
PD16311
ABSOLUTE MAXIMUM RATINGS (Ta = 25 C, VSS = 0 V)
PARAMETER
SYMBOL
RATINGS
UNIT
Logic Supply Voltage
VDD
0.5 to +7.0
V
Driver Supply Voltage
VEE
VDD +0.5 to VDD 40
V
Logic Input Voltage
VI1
0.5 to VDD +0.5
V
FIP Driver Output Voltage
VO2
VEE 0.5 to VDD +0.5
V
LED Driver Output Current
IO1
+25
mA
FIP Driver Output Current
IO2
40 (grid)
15 (segment)
mA
Power Dissipation
PD
1200*
mW
Operating Ambient Temperature
Topt
40 to +85
C
Storage Temperature
Tstg
65 to +150
C
*: Derate at 9.6 mW/C at Ta = 25 C or higher.
RECOMMENDED OPERATING CONDITIONS (Ta = 20 to +70 C, VSS = 0 V)
PARAMETER
SYMBOL
MIN.
TYP.
MAX.
UNIT
Logic Supply Voltage
VDD
4.5
5
5.5
V
High-Level Input Voltage
VIH
0.7 VDD
VDD
V
Low-Level Input Voltage
VIL
0
0.3 VDD
V
Driver Supply Votlage
VEE
0
VDD 35
V
TEST CONDITIONS
Maximum power consumption PMAX. = FIP driver dissipation + RL dissipation + LED driver dissipation + dynamic
power consumption
Where segment current = 3 mA, grid current = 15 mA, and LED current = 20 mA,
FIP driver dissipation = number of segments 6 + number of grids/(number of grids + 1) 30 (mW)
RL dissipation = (VDD VEE) /50 (segment + 1) (mW)
2
LED driver dissipation = number of LEDs 20 (mW)
Dynamic power consumption = VDD 5 (mW)
Example
Where VEE = 30 V, VDD = 5 V, and in 16-segment and 12-digit modes,
FIP driver dissipation = 16 6 +12/13 35 = 128
RL dissipation = 35 /50 17 = 417
2
LED driver dissipation = 5 20 = 100
Dynamic power consumption = 5 5 = 25
Total 670 mW
12
PD16311
ELECTRICAL SPECIFICATIONS (Ta = 20 to +70 C, VDD = 4.5 to 5.5 V, VSS = 0 V, VEE = VDD 35 V)
PARAMETER
SYMBOL
MIN.
High-Level Output Voltage
VOH1
0.9 VDD
Low-Level Output Voltage
VOL1
Low-Level Output Voltage
VOL2
High-Level Output Current
IOH21
3
mA
VO = VDD 2 V, Seg1 to Seg12
High-Level Output Current
IOH22
15
mA
VO = VDD 2 V, Grid1 to Grid8,
Seg13/ Grid16 to Seg12/ Grid9
Driver Leakage Current
IOLEAK
10
A
VO = VDD 35 V, driver off
150
K
Driver output
1
A
VI = VDD or VSS
Output Pull-Down Resistor
RL
Input Current
II
High-Level Input Voltage
VIH
Low-Level Input Voltage
VIL
Hysteresis Voltage
VH
Dynamic Current Consumption
50
TYP.
100
MAX.
UNIT
TEST CONDITIONS
V
LED1 LED5, IOH1 = 1 mA
1
V
LED1 LED5, IOL1 = 20 mA
0.4
V
DOUT, IOL2 = 4 mA
0.7 VDD
V
0.3 VDD
0.35
IDDdyn
V
V
5
mA
CLK, DIN, STB
Under no load, display off
SWITCHING CHARACTERISTICS (Ta = 20 to +70 C, VDD = 4.5 to 5.5 V, VEE = 30 V)
PARAMETER
SYMBOL
MIN.
TYP.
MAX.
UNIT
Oscillation Frequency
tOSC
350
500
650
kHz
Propagation Delay Time
tPLZ
300
ns
CLK DOUT
tPZL
100
ns
CL = 15 pF, RL = 10 k
tTZH1
2
s
CL = 300 pF
tTZH2
0.5
s
Fall time
tTHZ
120
s
Maximum Clock Frequency
fmax.
Rise Time
Input Capacitance
1
MHz
CI
15
TEST CONDITIONS
R = 56 k
Seg1 to Seg12
Grid1 to Grid8,
Seg13/Grid16 to
Seg20/Grid9
CL = 300 pF, Segn, Gridn
Duty = 50 %
pF
TIMING CONDITIONS (Ta = 20 to +70 C, VDD = 4.5 to 5.5 V)
PARAMETER
SYMBOL
MIN.
Clock Pulse Width
PWCLK
400
ns
Strobe Pulse Width
PWSTB
1
s
Data Setup Time
tSETUP
100
ns
Data Hold Time
tHOLD
100
ns
tCLK-STB
1
s
CLK STB tWAIT
1
s
CLK CLK *
Clock-Strobe Time
Wait Time
TYP.
MAX.
UNIT
TEST CONDITIONS
*: Refer to page 11.
13
PD16311
Switching Characteristic Waveform
fOSC
OSC
50 %
PWSTB
STB
PWCLK
PWCLK
tSETUP
tHOLD
tCLK-STB
CLK
DIN
tPZL
tPLZ
DOUT
tTHZ
90 %
Sn/Gn
10 %
14
tTZH
PD16311
Applications
Updating display memory by incrementing address
STB
CLK
DIN
Command 1
Command 2
Command 3
Data 1
Data n
Command 4
Command 1: sets display mode
Command 2: sets data
Command 3: sets address
Data 1 to n:
transfers display data (48 bytes max.)
Command 4: controls diplay
Updating specific address
STB
CLK
DIN
Command 1
Command 2
Data
Command 2
Data
Command 1: sets data
Command 2: sets address
Data:
display data
15
PD16311
RECOMMENDED SOLDERING CONDITIONS
The following conditions (see table below) must be met when soldering this product. Please consult with our sales
officers in case other soldering process is used or in case soldering is done under different conditions.
PD16311GC-AB6
Soldering process
Soldering conditions
Symbol
Infrared ray reflow
Peak package’s surface temperature: 235 C or below,
Reflow time: 30 seconds or below (210 C or higher),
Number of reflow process: 2, Exposure limit*: None
IR35-00-2
VPS
Peak package’s surface temperature: 215 C or below,
Reflow time: 40 seconds or below (200 C or higher),
Number of reflow process: 2, Exposure limit*: None
VP15-00-2
Wave soldering
Solder temperature: 260 C or below,
Flow time: 10 seconds or below,
Number of flow process: 1, Exposure limit*: None
WS60-00-1
Partial heating method
Terminal temperature: 300 C or below,
Flow time: 10 seconds or below,
Exposure limit*: None
* Exposure limit before soldering after dry-pack package is opened.
Storage conditions: 25 C and relative humidity at 65 % or less.
Note Do not apply more than a single process at once, except for “Partial heating method”.
16
PD16311
52 PIN PLASTIC QFP (14 × 14)
A
B
27
26
39
40
detail of lead end
C
D
S
R
Q
52
1
14
13
F
G
J
H
I
M
K
P
M
N
L
NOTE
Each lead centerline is located within 0.20 mm (0.008 inch) of
its true position (T.P.) at maximum material condition.
ITEM
MILLIMETERS
INCHES
A
17.6±0.4
0.693±0.016
B
14.0±0.2
0.551 +0.009
–0.008
C
14.0±0.2
0.551 +0.009
–0.008
D
17.6±0.4
0.693±0.016
F
1.0
0.039
G
1.0
0.039
H
0.40±0.10
0.016 +0.004
–0.005
I
0.20
0.008
J
1.0 (T.P.)
0.039 (T.P.)
K
1.8±0.2
0.071 +0.008
–0.009
L
0.8±0.2
0.031 +0.009
–0.008
M
0.15 +0.10
–0.05
0.006 +0.004
–0.003
N
0.10
0.004
P
2.6
0.102
Q
0.1±0.1
0.004±0.004
R
5°±5°
5°±5°
S
3.0 MAX.
0.119 MAX.
P52GC-100-AB6-4
17
PD16311
[MEMO]
18
PD16311
[MEMO]
19
PD16311
FIPTM is a trademark of NEC Corporation.
No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this
document.
NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual
property rights of third parties by or arising from use of a device described herein or any other liability arising
from use of such device. No license, either express, implied or otherwise, is granted under any patents,
copyrights or other intellectual property rights of NEC Corporation or others.
While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices,
the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or
property arising from a defect in an NEC semiconductor device, customers must incorporate sufficient safety
measures in its design, such as redundancy, fire-containment, and anti-failure features.
NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on
a customer designated "quality assurance program" for a specific application. The recommended applications
of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each
device before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment,
audio and visual equipment, home electronic appliances, machine tools, personal electronic
equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed
for life support)
Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.
Anti-radioactive design is not implemented in this product.