EN29LV800C Purpose Eon Silicon Solution Inc. (hereinafter called “Eon”) is going to provide its products’ top marking on ICs with < cFeon > from January 1st, 2009, and without any change of the part number and the compositions of the ICs. Eon is still keeping the promise of quality for all the products with the same as that of Eon delivered before. Please be advised with the change and appreciate your kindly cooperation and fully support Eon’s product family. Eon products’ New Top Marking cFeon Top Marking Example: cFeon Part Number: XXXX-XXX Lot Number: XXXXX Date Code: XXXXX Continuity of Specifications There is no change to this data sheet as a result of offering the device as an Eon product. Any changes that have been made are the result of normal data sheet improvement and are noted in the document revision summary, where supported. Future routine revisions will occur when appropriate, and changes will be noted in a revision summary. Continuity of Ordering Part Numbers Eon continues to support existing part numbers beginning with “Eon” and “cFeon” top marking. To order these products, during the transition please specify “Eon top marking” or “cFeon top marking” on your purchasing orders. For More Information Please contact your local sales office for additional information about Eon memory solutions. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 1 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C EN29LV800C 8 Megabit (1024K x 8-bit / 512K x 16-bit) Flash Memory Boot Sector Flash Memory, CMOS 3.0 Volt-only FEATURES • Sector protection: - Hardware locking of sectors to prevent program or erase operations within individual sectors - Additionally, temporary Sector Unprotect allows code changes in previously locked sectors. • Single power supply operation - Full voltage range: 2.7-3.6 volt read and write operations for battery-powered applications. - Regulated voltage range: 3.0-3.6 volt read and write operations and for compatibility with high performance 3.3 volt microprocessors. • High performance - Access times as fast as 70 ns • JEDEC Standard Embedded Erase and Program Algorithms • Low power consumption (typical values at 5 MHz) - 9 mA typical active read current - 20 mA typical program/erase current - 1 μA typical standby current (standard access time to active mode) • JEDEC standard DATA# polling and toggle bits feature • Single Sector and Chip Erase • Sector Unprotect Mode • Erase Suspend / Resume modes: Read or program another Sector during Erase Suspend Mode • Flexible Sector Architecture: - One 16-Kbyte, two 8-Kbyte, one 32-Kbyte, and fifteen 64-Kbyte sectors (byte mode) - One 8-Kword, two 4-Kword, one 16-Kword and fifteen 32-Kword sectors (word mode) • Low Vcc write inhibit < 2.5V • Minimum 100K endurance cycle • High performance program/erase speed - Byte/Word program time: 8µs typical - Sector erase time: 100ms typical • Package Options - 48-pin TSOP (Type 1) - 48-ball 6mm x 8mm TFBGA • Industrial and Automotive temperature Range GENERAL DESCRIPTION The EN29LV800C is an 8-Megabit, electrically erasable, read/write non-volatile flash memory, organized as 1,048,576 bytes or 524,288 words. Any byte can be programmed typically in 8µs. The EN29LV800C features 3.0V voltage read and write operation, with access time as fast as 70ns to eliminate the need for WAIT statements in high-performance microprocessor systems. The EN29LV800C has separate Output Enable (OE#), Chip Enable (CE#), and Write Enable (WE#) controls, which eliminate bus contention issues. This device is designed to allow either single Sector or full chip erase operation, where each sector can be individually protected against program/erase operations or temporarily unprotected to erase or program. The device can sustain a minimum of 100K program/erase cycles on each sector. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 2 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C CONNECTION DIAGRAMS A15 A14 A13 A12 A11 A10 A9 A8 NC NC WE# RESET# NC NC RY/BY# A18 A17 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 A16 BYTE# Vss DQ15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 Vcc DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE# Vss CE# A0 © 2004 Eon Silicon Solution, Inc., www.eonssi.com Standard TSOP 48-Ball TFBGA Top View, Balls Facing Down This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 3 Rev. H, Issue Date: 2011/10/26 EN29LV800C TABLE 1. PIN DESCRIPTION Pin Name FIGURE 1. LOGIC DIAGRAM Function EN29LV800C A0-A18 Addresses DQ0-DQ14 15 Data Inputs/Outputs DQ15 / A-1 DQ15 (data input/output, word mode), A-1 (LSB address input, byte mode) CE# Chip Enable OE# Output Enable OE# RESET# Hardware Reset Pin WE# RY/BY# Ready/Busy Output WE# Write Enable Vcc Supply Voltage (2.7-3.6V) Vss Ground NC Not Connected to anything BYTE# Byte/Word Mode DQ0 – DQ15 (A-1) A0 - A18 Reset# CE# RY/BY# Byte# This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 4 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C TABLE 2A. TOP BOOT BLOCK SECTOR ARCHITECTURE ADDRESS RANGE Sector SECTOR SIZE (Kbytes / Kwords) A18 A17 A16 A15 A14 A13 A12 (X16) (X8) 18 7E000h-7FFFFh FC000h-FFFFFh 16/8 1 1 1 1 1 1 X 17 7D000h-7DFFFh FA000h-FBFFFh 8/4 1 1 1 1 1 0 1 16 7C000h-7CFFFh F8000h-F9FFFh 8/4 1 1 1 1 1 0 0 15 78000h-7BFFFh F0000h – F7FFFh 32/16 1 1 1 1 0 X X 14 70000h-77FFFh E0000h - EFFFFh 64/32 1 1 1 0 X X X 13 68000h-6FFFFh D0000h - DFFFFh 64/32 1 1 0 1 X X X 12 60000h-6FFFFh C0000h - CFFFFh 64/32 1 1 0 0 X X X 11 58000h-5FFFFh B0000h - BFFFFh 64/32 1 0 1 1 X X X 10 50000h-57FFFh A0000h - AFFFFh 64/32 1 0 1 0 X X X 9 48000h-4FFFFh 90000h - 9FFFFh 64/32 1 0 0 1 X X X 8 40000h-47FFFh 80000h - 8FFFFh 64/32 1 0 0 0 X X X 7 38000h-3FFFFh 70000h - 7FFFFh 64/32 0 1 1 1 X X X 6 30000h-37FFFh 60000h - 6FFFFh 64/32 0 1 1 0 X X X 5 28000h-2FFFFh 50000h – 5FFFFh 64/32 0 1 0 1 X X X 4 20000h-27FFFh 40000h – 4FFFFh 64/32 0 1 0 0 X X X 3 18000h-1FFFFh 30000h – 3FFFFh 64/32 0 0 1 1 X X X 2 10000h-17FFFh 20000h - 2FFFFh 64/32 0 0 1 0 X X X 1 08000h-0FFFFh 10000h - 1FFFFh 64/32 0 0 0 1 X X X 0 00000h-07FFFh 00000h - 0FFFFh 64/32 0 0 0 0 X X X This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 5 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C TABLE 2B. BOTTOM BOOT BLOCK SECTOR ARCHITECTURE ADDRESS RANGE Sector SECTOR SIZE (Kbytes/ Kwords) A18 A17 A16 A15 A14 A13 A12 (X16) (X8) 18 78000h-7FFFFh F0000h – FFFFFh 64/32 1 1 1 1 X X X 17 70000h-77FFFh E0000h – EFFFFh 64/32 1 1 1 0 X X X 16 68000h-6FFFFh D0000h – DFFFFh 64/32 1 1 0 1 X X X 15 60000h-67FFFh C0000h – CFFFFh 64/32 1 1 0 0 X X X 14 58000h-5FFFFh B0000h - BFFFFh 64/32 1 0 1 1 X X X 13 50000h-57FFFh A0000h - AFFFFh 64/32 1 0 1 0 X X X 12 48000h-4FFFFh 90000h – 9FFFFh 64/32 1 0 0 1 X X X 11 40000h-47FFFh 80000h – 8FFFFh 64/32 1 0 0 0 X X X 10 38000h-3FFFFh 70000h –7FFFFh 64/32 0 1 1 1 X X X 9 30000h-37FFFh 60000h – 6FFFFh 64/32 0 1 1 0 X X X 8 28000h-2FFFFh 50000h – 5FFFFh 64/32 0 1 0 1 X X X 7 20000h-27FFFh 40000h – 4FFFFh 64/32 0 1 0 0 X X X 6 18000h-1FFFFh 30000h – 3FFFFh 64/32 0 0 1 1 X X X 5 10000h-17FFFh 20000h – 2FFFFh 64/32 0 0 1 0 X X X 4 08000h-0FFFFh 10000h – 1FFFFh 64/32 0 0 0 1 X X X 3 04000h-07FFFh 08000h – 0FFFFh 32/16 0 0 0 0 1 X X 2 03000h-03FFFh 06000h – 07FFFh 8/4 0 0 0 0 0 1 1 1 02000h-02FFFh 04000h – 05FFFh 8/4 0 0 0 0 0 1 0 0 00000h-01FFFh 00000h – 03FFFh 16/8 0 0 0 0 0 0 X This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 6 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C PRODUCT SELECTOR GUIDE EN29LV800C Product Number Full Voltage Range: Vcc=2.7 – 3.6 V -70 Max Access Time, ns (tacc) 70 Max CE# Access, ns (tce) 70 Max OE# Access, ns (toe) 30 BLOCK DIAGRAM RY/BY# Vcc Vss DQ0-DQ15 (A-1) Block Protect Switches Erase Voltage Generator Input/Output Buffers State Control WE# Command Register Program Voltage Generator Chip Enable Output Enable Logic CE# OE# Vcc Detector Timer Address Latch STB STB Data Latch Y-Decoder Y-Gating X-Decoder Cell Matrix A0-A18 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 7 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C TABLE 3. OPERATING MODES 8M FLASH USER MODE TABLE OE# WE# L L Vcc ± 0.3V L X L H X H X H L X H X H H Vcc ± 0.3V H L AIN AIN X X X DOUT DIN High-Z High-Z High-Z DQ8-DQ15 Byte# Byte# = VIH = VIL DOUT High-Z DIN High-Z High-Z High-Z High-Z High-Z High-Z High-Z X X X VID AIN DIN DIN Operation CE# Read Write CMOS Standby Output Disable Hardware Reset Temporary Sector Unprotect Reset# A0A18 DQ0-DQ7 X Notes: L=logic low= VIL, H=Logic High= VIH, VID =11 ± 0.5V, X=Don’t Care (either L or H, but not floating!), DIN=Data In, DOUT=Data Out, AIN=Address In TABLE 4. DEVICE IDENTIFICTION (Autoselect Codes) 8M FLASH MANUFACTURER/DEVICE ID TABLE Description Mode CE # OE # W E# L Device ID Word L L H Byte L L H Word L L H Byte L L H L L H Device ID (bottom boot block) Sector Protection Verification A11 to A10 2 A9 A8 A7 A6 A5 to A2 A1 A0 DQ8 to DQ15 X L X L L X DQ7 to DQ0 1 Manufacturer ID: Eon (top boot block) A18 to A12 L H X X VID H 1Ch L 7Fh X X VID X X L X L H X X VID X X L X L H SA X VID X X L X H L 22h DAh X DAh 22h 5Bh X 5Bh X X 01h (Protected) 00h (Unprotected) L=logic low= VIL, H=Logic High= VIH, VID =11 ± 0.5V, X=Don’t Care (either L or H, but not floating!), SA=Sector Addresses Note: 1. A8=H is recommended for Manufacturing ID check. If a manufacturing ID is read with A8=L, the chip will output a configuration code 7Fh. 2. A9 = VID is for HV A9 Autoselect mode only. A9 must be ≤ Vcc (CMOS logic level) for Command Autoselect Mode. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 8 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C USER MODE DEFINITIONS Word / Byte Configuration The signal set on the BYTE# Pin controls whether the device data I/O pins DQ15-DQ0 operate in the byte or word configuration. When the Byte# Pin is set at logic ‘1’, then the device is in word configuration, DQ15-DQ0 are active and are controlled by CE# and OE#. On the other hand, if the Byte# Pin is set at logic ‘0’, then the device is in byte configuration, and only data I/O pins DQ0-DQ7 are active and controlled by CE# and OE#. The data I/O pins DQ8-DQ14 are tri-stated, and the DQ15 pin is used as an input for the LSB (A-1) address function. Standby Mode The EN29LV800C has a CMOS-compatible standby mode, which reduces the current to < 1µA (typical). It is placed in CMOS-compatible standby when the CE# pin is at VCC ± 0.5. RESET# and BYTE# pin must also be at CMOS input levels. When in standby modes, the outputs are in a high-impedance state independent of the OE# input. Read Mode The device is automatically set to reading array data after device power-up. No commands are required to retrieve data. The device is also ready to read array data after completing an Embedded Program or Embedded Erase algorithm. After the device accepts an Erase Suspend command, the device enters the Erase Suspend mode. The system can read array data using the standard read timings, except that if it reads at an address within erase-suspended sectors, the device outputs status data. After completing a programming operation in the Erase Suspend mode, the system may once again read array data with the same exception. See “Erase Suspend/Erase Resume Commands” for more additional information. The system must issue the reset command to re-enable the device for reading array data if DQ5 goes high, or while in the autoselect mode. See the “Reset Command” additional details. Output Disable Mode When the OE# pin is at a logic high level (VIH), the output from the EN29LV800C is disabled. The output pins are placed in a high impedance state. Auto Select Identification Mode The autoselect mode provides manufacturer and device identification, and sector protection verification, through identifier codes output on DQ15–DQ0. This mode is primarily intended for programming equipment to automatically match a device to be programmed with its corresponding programming algorithm. However, the autoselect codes can also be accessed in-system through the command register. When using programming equipment, the autoselect mode requires VID (10.5 V to 11.5 V) on address pin A9. Address pins A8, A6, A1, and A0 must be as shown in Autoselect Codes table. In addition, when verifying sector protection, the sector address must appear on the appropriate highest order address bits. Refer to the corresponding Sector Address Tables. The Command Definitions table shows the remaining address bits that are don’t-care. When all necessary bits have been set as required, the programming equipment may then read the corresponding identifier code on DQ15–DQ0. To access the autoselect codes in-system; the host system can issue the autoselect command via the command register, as shown in the Command Definitions table. This method does not require VID. See “Command Definitions” for details on using the autoselect mode. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 9 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Write Mode Write operations, including programming data and erasing sectors of memory, require the host system to write a command or command sequence to the device. Write cycles are initiated by placing the byte or word address on the device’s address inputs while the data to be written is input on DQ[7:0] in Byte Mode (BYTE# = L) or on DQ[15:0] in Word Mode (BYTE# = H). The host system must drive the CE# and WE# pins Low and the OE# pin High for a valid write operation to take place. All addresses are latched on the falling edge of WE# and CE#, whichever happens later. All data is latched on the rising edge of WE# or CE#, whichever happens first. The system is not required to provide further controls or timings. The device automatically provides internally generated program / erase pulses and verifies the programmed /erased cells’ margin. The host system can detect completion of a program or erase operation by observing the RY/BY# pin, or by reading the DQ[7] (Data# Polling) and DQ[6] (Toggle) status bits. The ‘Command Definitions’ section of this document provides details on the specific device commands implemented in the EN29LV800C. Sector Protection/Unprotection The hardware sector protection features disables both program and erase operations in any sector. The hardware sector unprotection features re-enables both program and erase operations in previously protected sectors. There are two methods to enabling this hardware protection circuitry. The first one requires only that the RESET# pin be at VID and then standard microprocessor timings can be used to enable or disable this feature. See Flowchart 7a and 7b for the algorithm and Figure 12 for the timings. When doing Sector Unprotect, all the other sectors should be protected first. The second method is meant for programming equipment. This method requires VID be applied to both OE# and A9 pin and non-standard microprocessor timings are used. This method is described in a separate document called EN29LV800C Supplement, which can be obtained by contacting a representative of Eon Silicon Solution, Inc. Temporary Sector Unprotect Start This feature allows temporary unprotection of previously protected sector groups to change data while in-system. The Sector Unprotect mode is activated by setting the RESET# pin to VID. During this mode, formerly protected sectors can be programmed or erased by simply selecting the sector addresses. Once is removed from the RESET# pin, all the previously protected sectors are protected again. See accompanying figure and timing diagrams for more details. Notes: 1. All protected sectors unprotected. 2. Previously protected sectors protected again. Reset#=VID (note 1) Perform Erase or Program Operations Reset#=VIH Temporary Sector Unprotect Completed (note 2) Automatic Sleep Mode The automatic sleep mode minimizes Flash device energy consumption. The device automatically enables this mode when addresses remain stable for tacc + 30ns. The automatic sleep mode is independent of the CE#, WE# and OE# control signals. Standard address access timings provide new data when addresses are changed. While in sleep mode, output is latched and always available to the system. ICC4 in the DC Characteristics table represents the automatic sleep more current specification. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 10 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Hardware Data Protection The command sequence requirement of unlock cycles for programming or erasing provides data protection against inadvertent writes as seen in the Command Definitions table. Additionally, the following hardware data protection measures prevent accidental erasure or programming, which might otherwise be caused by false system level signals during Vcc power up and power down transitions, or from system noise. Low VCC Write Inhibit When Vcc is less than VLKO, the device does not accept any write cycles. This protects data during Vcc power up and power down. The command register and all internal program/erase circuits are disabled, and the device resets. Subsequent writes are ignored until Vcc is greater than VLKO. The system must provide the proper signals to the control pins to prevent unintentional writes when Vcc is greater than VLKO. Write Pulse “Glitch” protection Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle. Logical Inhibit Write cycles are inhibited by holding any one of OE# = VIL, CE# = VIH, or WE# = VIH. To initiate a write cycle, CE# and WE# must be a logical zero while OE# is a logical one. If CE#, WE#, and OE# are all logical zero (not recommended usage), it will be considered a read. Power-up Write Inhibit During power-up, the device automatically resets to READ mode and locks out write cycles. Even with CE# = VIL, WE# = VIL and OE# = VIH, the device will not accept commands on the rising edge of WE#. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 11 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C COMMAND DEFINITIONS The operations of EN29LV800C are selected by one or more commands written into the command register to perform Read/Reset Memory, Read ID, Read Sector Protection, Program, Sector Erase, Chip Erase, Erase Suspend and Erase Resume. Commands are made up of data sequences written at specific addresses via the command register. The sequences for the specified operation are defined in the Command Definitions table (Table 5). Incorrect addresses, incorrect data values or improper sequences will reset the device to Read Mode. Table 5. EN29LV800C Command Definitions Cycles Bus Cycles Command Sequence Read Reset Autoselect Manufacturer ID Device ID Top Boot Device ID Bottom Boot Sector Protect Verify Program Chip Erase Sector Erase 1 1 Word st 1 RA xxx 4 Word 555 AAA 555 AAA Byte Word Byte Word Byte Word Byte Erase Suspend Erase Resume AA AA 6 6 1 1 6 Cycle Addr Data Cycle Addr Data Cycle Addr Data Cycle Addr Data Cycle Addr Data 2AA 555 2AA 555 2AA 555 55 555 AAA 10 55 SA 30 55 2AA 555 2AA 555 2AA AA AAA 4 555 AAA 555 AAA 555 AAA xxx xxx th 5 555 555 4 th 4 AA AAA 4 th 3 RD F0 555 Byte rd 2 Cycle Addr Data 4 Word Byte Word Byte nd AAA 55 55 AA AA 555 AAA 555 AAA 2AA 555 2AA 555 2AA 555 90 90 555 55 555 AA 90 90 AAA 55 55 55 555 AAA 555 AAA 555 AAA A0 80 80 000/ 100 000/ 200 X01 X02 X01 X02 (SA) X02 (SA) X04 7F/ 1C 7F/ 1C 22DA DA 225B 5B XX00 XX01 00 01 PA PD 555 AAA 555 AAA AA AA B0 30 Address and Data values indicated in hex RA = Read Address: address of the memory location to be read. This is a read cycle. RD = Read Data: data read from location RA during Read operation. This is a read cycle. PA = Program Address: address of the memory location to be programmed. X = Don’t-Care PD = Program Data: data to be programmed at location PA SA = Sector Address: address of the Sector to be erased or verified. Address bits A18-A12 uniquely select any Sector. Reading Array Data The device is automatically set to reading array data after power up. No commands are required to retrieve data. The device is also ready to read array data after completing an Embedded Program or Embedded Erase algorithm. Following an Erase Suspend command, Erase Suspend mode is entered. The system can read array data using the standard read timings, with the only difference in that if it reads at an address within erase suspended sectors, the device outputs status data. After completing a programming operation in the Erase Suspend mode, the system may once again read array data with the same exception. The Reset command must be issued to re-enable the device for reading array data if DQ5 goes high, or while in the autoselect mode. See next section for details on Reset. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 12 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Reset Command Writing the reset command to the device resets the device to reading array data. Address bits are don’tcare for this command. The reset command may be written between the sequence cycles in an erase command sequence before erasing begins. This resets the device to reading array data. Once erasure begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the device to reading array data (also applies to programming in Erase Suspend mode). Once programming begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to reading array data (also applies to autoselect during Erase Suspend). If DQ5 goes high during a program or erase operation, writing the reset command returns the device to reading array data (also applies during Erase Suspend). Autoselect Command Sequence The autoselect command sequence allows the host system to access the manufacturer and devices codes, and determine whether or not a sector is protected. The Command Definitions table shows the address and data requirements. This is an alternative to the method that requires VID on address bit A9 and is intended for PROM programmers. Two unlock cycles followed by the autoselect command initiate the autoselect command sequence. Autoselect mode is then entered and the system may read at addresses shown in Table 4 any number of times, without needing another command sequence. The system must write the reset command to exit the autoselect mode and return to reading array data. Word / Byte Programming Command The device may be programmed by byte or by word, depending on the state of the Byte# Pin. Programming the EN29LV800C is performed by using a four bus-cycle operation (two unlock write cycles followed by the Program Setup command and Program Data Write cycle). When the program command is executed, no additional CPU controls or timings are necessary. An internal timer terminates the program operation automatically. Address is latched on the falling edge of CE# or WE#, whichever is last; data is latched on the rising edge of CE# or WE#, whichever is first. Programming status may be checked by sampling data on DQ7 (DATA# polling) or on DQ6 (toggle bit). When the program operation is successfully completed, the device returns to read mode and the user can read the data programmed to the device at that address. Note that data can not be programmed from a 0 to a 1. Only an erase operation can change a data from 0 to 1. When programming time limit is exceeded, DQ5 will produce a logical “1” and a Reset command can return the device to Read mode. Chip Erase Command Chip erase is a six-bus-cycle operation. The chip erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the chip erase command, which in turn invokes the Embedded Erase algorithm. The device does not require the system to preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and verifies the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. The Command Definitions table shows the address and data requirements for the chip erase command sequence. Any commands written to the chip during the Embedded Chip Erase algorithm are ignored. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 13 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. See “Write Operation Status” for information on these status bits. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. Flowchart 4 illustrates the algorithm for the erase operation. See the Erase/Program Operations tables in “AC Characteristics” for parameters, and to the Chip/Sector Erase Operation Timings for timing waveforms. Sector Erase Command Sequence Sector erase is a six bus cycle operation. The sector erase command sequence is initiated by writing two un-lock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the address of the sector to be erased, and the sector erase command. The Command Definitions table shows the address and data requirements for the sector erase command sequence. Once the sector erase operation has begun, only the Erase Suspend command is valid. All other commands are ignored. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. Refer to “Write Operation Status” for information on these status bits. Flowchart 4 illustrates the algorithm for the erase operation. Refer to the Erase/Program Operations tables in the “AC Characteristics” section for parameters, and to the Sector Erase Operations Timing diagram for timing waveforms. Erase Suspend / Resume Command The Erase Suspend command allows the system to interrupt a sector erase operation and then read data from, or program data to, any sector not selected for erasure. This command is valid only during the sector erase operation. The Erase Suspend command is ignored if written during the chip erase operation or Embedded Program algorithm. Addresses are don’t-cares when writing the Erase Suspend command. When the Erase Suspend command is written during a sector erase operation, the device requires a maximum of 20 µs to suspend the erase operation. After the erase operation has been suspended, the system can read array data from or program data to any sector not selected for erasure. (The device “erase suspends” all sectors selected for erasure.) Normal read and write timings and command definitions apply. Reading at any address within erasesuspended sectors produces status data on DQ7–DQ0. The system can use DQ7, or DQ6 and DQ2 together, to determine if a sector is actively erasing or is erase-suspended. See “Write Operation Status” for information on these status bits. After an erase-suspended program operation is complete, the system can once again read array data within non-suspended sectors. The system can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in the standard program operation. See “Write Operation Status” for more information. The Autoselect command is not supported during Erase Suspend Mode. The system must write the Erase Resume command (address bits are don’t-care) to exit the erase suspend mode and continue the sector erase operation. Further writes of the Resume command are ignored. Another Erase Suspend command can be written after the device has resumed erasing. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 14 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C WRITE OPERATION STATUS DQ7: DATA# Polling The EN29LV800C provides DATA# polling on DQ7 to indicate the status of the embedded operations. The DATA# Polling feature is active during the embedded Programming, Sector Erase, Chip Erase, and Erase Suspend. (See Table 6) When the embedded Programming is in progress, an attempt to read the device will produce the complement of the data last written to DQ7. Upon the completion of the embedded Programming, an attempt to read the device will produce the true data written to DQ7. For the embedded Programming, DATA# polling is valid after the rising edge of the fourth WE# or CE# pulse in the four-cycle sequence. When the embedded Erase is in progress, an attempt to read the device will produce a “0” at the DQ7 output. Upon the completion of the embedded Erase, the device will produce the “1” at the DQ7 output during the read cycles. For Chip Erase, the DATA# polling is valid after the rising edge of the sixth WE# or CE# pulse in the six-cycle sequence. DATA# polling is valid after the last rising edge of the WE# or CE# pulse for chip erase or sector erase. DATA# Polling must be performed at any address within a sector that is being programmed or erased and not a protected sector. Otherwise, DATA# polling may give an inaccurate result if the address used is in a protected sector. Just prior to the completion of the embedded operations, DQ7 may change asynchronously when the output enable (OE#) is low. This means that the device is driving status information on DQ7 at one instant of time and valid data at the next instant of time. Depending on when the system samples the DQ7 output, it may read the status of valid data. Even if the device has completed the embedded operations and DQ7 has a valid data, the data output on DQ0-DQ6 may be still invalid. The valid data on DQ0-DQ7 will be read on the subsequent read attempts. The flowchart for DATA# Polling (DQ7) is shown on Flowchart 5. The DATA# Polling (DQ7) timing diagram is shown in Figure 8. RY/BY#: Ready/Busy The RY/BY# is a dedicated, open-drain output pin that indicates whether an Embedded Algorithm is in progress or completed. The RY/BY# status is valid after the rising edge of the final WE# pulse in the command sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied together in parallel with a pull-up resistor to Vcc. In the output-low period, signifying Busy, the device is actively erasing or programming. This includes programming in the Erase Suspend mode. If the output is high, signifying the Ready, the device is ready to read array data (including during the Erase Suspend mode), or is in the standby mode. DQ6: Toggle Bit I The EN29LV800C provides a “Toggle Bit” on DQ6 to indicate to the host system the status of the embedded programming and erase operations. (See Table 6) During an embedded Program or Erase operation, successive attempts to read data from the device at any address (by active OE# or CE#) will result in DQ6 toggling between “zero” and “one”. Once the embedded Program or Erase operation is completed, DQ6 will stop toggling and valid data will be read on the next successive attempts. During embedded Programming, the Toggle Bit is valid after the rising edge of the fourth WE# pulse in the four-cycle sequence. During Erase operation, the Toggle Bit is valid after the rising edge of the sixth WE# pulses for sector erase or chip erase. In embedded Programming, if the sector being written to is protected, DQ6 will toggles for about 2 μs, then stop toggling without the data in the sector having changed. In Sector Erase or Chip Erase, if all This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 15 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C selected sectors are protected, DQ6 will toggle for about 100 μs. The chip will then return to the read mode without changing data in all protected sectors. The flowchart for the Toggle Bit (DQ6) is shown in Flowchart 6. The Toggle Bit timing diagram is shown in Figure 9. DQ5: Exceeded Timing Limits DQ5 indicates whether the program or erase time has exceeded a specified internal pulse count limit. Under these conditions DQ5 produces a “1.” This is a failure condition that indicates the program or erase cycle was not successfully completed. Since it is possible that DQ5 can become a 1 when the device has successfully completed its operation and has returned to read mode, the user must check again to see if the DQ6 is toggling after detecting a “1” on DQ5. The DQ5 failure condition may appear if the system tries to program a “1” to a location that is previously programmed to “0.” Only an erase operation can change a “0” back to a “1.” Under this condition, the device halts the operation, and when the operation has exceeded the timing limits, DQ5 produces a “1.” Under both these conditions, the system must issue the reset command to return the device to reading array data. DQ3: Sector Erase Timer After writing a sector erase command sequence, the output on DQ3 can be used to determine whether or not an erase operation has begun. (The sector erase timer does not apply to the chip erase command.) When sector erase starts, DQ3 switches from “0” to “1.” This device does not support multiple sector erase command sequences so it is not very meaningful since it immediately shows as a “1” after the first 30h command. Future devices may support this feature. DQ2: Erase Toggle Bit II The “Toggle Bit” on DQ2, when used with DQ6, indicates whether a particular sector is actively erasing (that is, the Embedded Erase algorithm is in progress), or whether that sector is erase-suspended. Toggle Bit II is valid after the rising edge of the final WE# pulse in the command sequence. DQ2 toggles when the system reads at addresses within those sectors that have been selected for erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2 cannot distinguish whether the sector is actively erasing or is erase-suspended. DQ6, by comparison, indicates whether the device is actively erasing, or is in Erase Suspend, but cannot distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and mode information. Refer to the following table to compare outputs for DQ2 and DQ6. Flowchart 6 shows the toggle bit algorithm, and the section “DQ2: Toggle Bit” explains the algorithm. See also the “DQ6: Toggle Bit I” subsection. Refer to the Toggle Bit Timings figure for the toggle bit timing diagram. The DQ2 vs. DQ6 figure shows the differences between DQ2 and DQ6 in graphical form. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 16 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Reading Toggle Bits DQ6/DQ2 Refer to Flowchart 6 for the following discussion. Whenever the system initially begins reading toggle bit status, it must read DQ7–DQ0 at least twice in a row to determine whether a toggle bit is toggling. Typically, a system would note and store the value of the toggle bit after the first read. After the second read, the system would compare the new value of the toggle bit with the first. If the toggle bit is not toggling, the device has completed the program or erase operation. The system can read array data on DQ7–DQ0 on the following read cycle. However, if after the initial two read cycles, the system determines that the toggle bit is still toggling, the system also should note whether the value of DQ5 is high (see the section on DQ5). If it is, the system should then determine again whether the toggle bit is toggling, since the toggle bit may have stopped toggling just as DQ5 went high. If the toggle bit is no longer toggling, the device has successfully completed the program or erase operation. If it is still toggling, the device did not complete the operation successfully, and the system must write the reset command to return to reading array data. The remaining scenario is that the system initially determines that the toggle bit is toggling and DQ5 has not gone high. The system may continue to monitor the toggle bit and DQ5 through successive read cycles, determining the status as described in the previous paragraph. Alternatively, it may choose to perform other system tasks. In this case, the system must start at the beginning of the algorithm when it returns to determine the status of the operation (top of Flowchart 6). Write Operation Status Operation Standard Mode Erase Suspend Mode DQ7 DQ6 DQ5 DQ3 DQ2 RY/BY# Embedded Program Algorithm DQ7# Toggle 0 N/A No toggle 0 Embedded Erase Algorithm 0 Toggle 0 1 Toggle 0 1 No Toggle 0 N/A Toggle 1 Data Data Data Data Data 1 DQ7# Toggle 0 N/A N/A 0 Reading within Erase Suspended Sector Reading within Non-Erase Suspended Sector Erase-Suspend Program This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 17 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Table 6. Status Register Bits DQ Name Logic Level ‘1’ 7 DATA# ‘0’ POLLING DQ7 DQ7# 6 TOGGLE BIT 5 TIME OUT BIT 3 ERASE TIME OUT BIT 2 TOGGLE BIT Definition Erase Complete or erase Sector in Erase suspend Erase On-Going Program Complete or data of non-erase Sector during Erase Suspend ‘-1-0-1-0-1-0-1-’ DQ6 Program On-Going Erase or Program On-going Read during Erase Suspend ‘-1-1-1-1-1-1-1-‘ Erase Complete ‘1’ ‘0’ ‘1’ ‘0’ ‘-1-0-1-0-1-0-1-’ DQ2 Program or Erase Error Program or Erase On-going Erase operation start Erase timeout period on-going Chip Erase, Sector Erase or Erase suspend on currently addressed Sector. (When DQ5=1, Erase Error due to currently addressed Sector. Program during Erase Suspend on-going at current address Erase Suspend read on non Erase Suspend Sector Notes: DQ7 DATA# Polling: indicates the P/E C status check during Program or Erase, and on completion before checking bits DQ5 for Program or Erase Success. DQ6 Toggle Bit: remains at constant level when P/E operations are complete or erase suspend is acknowledged. Successive reads output complementary data on DQ6 while programming or Erase operation are on-going. DQ5 TIME OUT BIT: set to “1” if failure in programming or erase DQ3 Sector Erase Command Timeout Bit: Operation has started. Only possible command is Erase suspend (ES). DQ2 Toggle Bit: indicates the Erase status and allows identification of the erased Sector. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 18 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C EMBEDDED ALGORITHMS Flowchart 1. Embedded Program START Write Program Command Sequence (shown below) Data# Polling Device Verify Data? No Yes Increment Address Last No Address? Yes Programming Done Flowchart 2. Embedded Program Command Sequence See the Command Definitions section for more information on WORD mode. 555H / AAH 2AAH / 55H 555H / A0H PROGRAM ADDRESS / PROGRAM DATA This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 19 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Flowchart 3. Embedded Erase START Write Erase Command Sequence Data Poll from System or Toggle Bit successfully completed Data =FFh? No Yes Erase Done Flowchart 4. Embedded Erase Command Sequence See the Command Definitions section for more information on WORD mode. Chip Erase Sector Erase 555H/AAH 555H/AAH 2AAH/55H 2AAH/55H 555H/80H 555H/80H 555H/AAH 555H/AAH 2AAH/55H 2AAH/55H 555H/10H Sector Address/30H This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 20 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Flowchart 5. DATA# Polling Algorithm Start Read Data DQ7 = Data? Yes No No DQ5 = 1? Yes Read Data (1) Notes: (1) This second read is necessary in case the first read was done at the exact instant when the status data was in transition. DQ7 = Data? Yes No Fail Pass Start Flowchart 6. Toggle Bit Algorithm Read Data twice DQ6 = Toggle? No Yes No DQ5 = 1? Yes Read Data twice (2) Notes: (2) This second set of reads is necessary in case the first set of reads was done at the exact instant when the status data was in transition. DQ6 = Toggle? Yes Fail This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. No 21 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 Pass www.eonssi.com EN29LV800C Flowchart 7a. In-System Sector Protect Flowchart START PLSCNT = 1 RESET# = VID Wait 1 μs No First Write Cycle = 60h? Temporary Sector Unprotect Mode Yes Set up sector address Sector Protect: Write 60h to sector addr with A6 = 0, A1 = 1, A0 = 0 Wait 150 μs Verify Sector Protect: Write 40h to sector address with A6 = 0, A1 = 1, A0 = 0 Increment PLSCNT Reset PLSCNT = 1 Wait 0.4 μs Read from sector address with A6 = 0, A1 = 1, A0 = 0 No PLSCNT = 25? No Data = 01h? Yes Yes Device failed Protect another sector? Yes No Remove VID from RESET# Write reset command Sector Protect Algorithm This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. Sector Protect complete 22 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Flowchart 7b. In-System Sector Unprotect Flowchart START PLSCNT = 1 Protect all sectors: The indicated portion of the sector protect algorithm must be performed for all unprotected sectors prior to issuing the first sector unprotect address (see Diagram 7a.) RESET# = VID Wait 1 μS No Temporary Sector Unprotect Mode First Write Cycle = 60h? Yes No All sectors protected? Yes Set up first sector address Sector Unprotect: Write 60H to sector address with A6 = 1, A1 = 1, A0 = 0 Wait 15 ms Increment PLSCNT Verify Sector Unprotect: Write 40h to sector address with A6 = 1, A1 = 1, A0 =0 Wait 0.4 μS No PLSCNT = 1000? Sector Unprotect Algorithm Read from sector address with A6 = 1, A1 = 1, A0 = 0 No Yes Yes Device failed Set up next sector address Data = 00h? No Last sector verified? Yes Remove VID from RESET# This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 23 Write reset command Sector Unprotect complete © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Table 7. DC Characteristics (Ta = - 40°C to 85°C or - 45°C to 125°C; VCC = 2.7-3.6V) Symbol Parameter Test Conditions ILI Input Leakage Current 0V≤ VIN ≤ Vcc ILO Output Leakage Current 0V≤ VOUT ≤ Vcc (read) CMOS Byte ICC1 CE# = VIL; OE# = VIH; f = 5MHz (read) CMOS Word Supply Current (Standby - CMOS) ICC2 Min Supply Current (Standby - CMOS) For Automotive (-45°C to +125°C) ICC3 Supply Current (Program or Erase) ICC4 Automatic Sleep Mode VIL Input Low Voltage VIH Input High Voltage VOL Output Low Voltage CE# = BYTE# = RESET# = Vcc ± 0.3V (Note 1) CE# = BYTE# = RESET# = Vcc ± 0.3V (Note 1) Byte program, Sector or Chip Erase in progress VIH = Vcc ± 0.3 V VIL = Vss ± 0.3 V Typ VID A9 Voltage (Electronic Signature) IID A9 Current (Electronic Signature) VLKO Supply voltage (Erase and Program lock-out) IOH = -100 μA, ±5 µA ±5 µA 18 mA 7 20 mA 1 5.0 µA 1 20 µA 15 30 mA 1 5.0 µA 0.8 Vcc + 0.3 0.45 V IOL = 4.0 mA Output High Voltage CMOS Unit 6 -0.5 0.7 x Vcc VOH Max Vcc 0.4V 10.5 A9 = VID 2.3 V V V 11.5 V 100 µA 2.5 V Notes 1. BYTE# pin can also be GND ± 0.3V. BYTE# and RESET# pin input buffers are always enabled so that they draw power if not at full CMOS supply voltages. 2. Maximum ICC specifications are tested with Vcc = Vcc max. B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 24 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Test Conditions Device Under Test CL Test Specifications Test Conditions -70 Unit Output Load Capacitance, CL 30 pF Input Rise and Fall times 5 ns Input Pulse Levels Input timing measurement reference levels Output timing measurement reference levels 0.0-3.0 V 1.5 V 1.5 V This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 25 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C AC CHARACTERISTICS Hardware Reset (Reset#) (Ta = - 40°C to 85°C or - 45°C to 125°C; VCC = 2.7-3.6V) Parameter Std tRP1 tRP2 tRH tRB1 tRB2 tREADY1 tREADY2 Description RESET# Pulse Width (During Embedded Algorithms) RESET# Pulse Width (NOT During Embedded Algorithms) Reset# High Time Before Read RY/BY# Recovery Time ( to CE#, OE# go low) RY/BY# Recovery Time ( to WE# go low) Reset# Pin Low (During Embedded Algorithms) to Read or Write Reset# Pin Low (NOT During Embedded Algorithms) to Read or Write Test Setup Min Min Min Min Min Speed -70 10 500 50 0 50 Unit Max 20 us Max 500 ns us ns ns ns ns Figure 1. AC Waveforms for RESET# Reset# Timings This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 26 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C AC CHARACTERISTICS Word / Byte Configuration (Byte#) (Ta = - 40°C to 85°C or - 45°C to 125°C; VCC = 2.7-3.6V) Std Parameter tBCS tCBH tRBH Speed Unit -70 Description Byte# to CE# switching setup time CE# to Byte# switching hold time RY/BY# to Byte# switching hold time Min Min Min 0 0 0 ns ns ns Figure 2. AC Waveforms for BYTE# CE# OE# Byte# tCBH tBCS Byte# timings for Read Operations CE# WE# Byte# tRBH tBCS RY/BY# Byte #timings for Write Operations This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 27 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Table 8. AC CHARACTERISTICS (Ta = - 40°C to 85°C or - 45°C to 125°C; VCC = 2.7-3.6V) Read-only Operations Characteristics Parameter Symbols JEDEC Standard Speed Test Setup Description tAVAV tRC Read Cycle Time tAVQV tACC Address to Output Delay tELQV tCE Chip Enable to Output Delay tGLQV tOE tEHQZ Unit -70 Min 70 ns CE# = VIL OE# = VIL Max 70 ns OE# = VIL Max 70 ns Output Enable to Output Delay Max 30 ns tDF Chip Enable to Output High Z Max 20 ns tGHQZ tDF Output Enable to Output High Z Max 20 ns tAXQX tOH Min 0 ns 0 ns 10 ns tOEH B B Output Hold Time from Addresses, CE# or OE#, whichever occurs first Read Output Enable Toggle and Hold Time Data# Polling Min Min Notes: 1. High Z is Not 100% tested. 2. For - 70 Vcc = 2.7V – 3.6V Output Load: 30 pF Input Rise and Fall Times: 5 ns Input Pulse Levels: 0.0 V to Vcc Timing Measurement Reference Level, Input and Output: 1.5 V tBRCB Addresses Addresses Stable tBACC CE# tBDF tBOEB OE# tBOEHB WE# tBCEB tBOH HIGH Z Outputs Output Valid HIGH Z RESET# RY/BY# 0V Figure 3. AC Waveforms for READ Operations This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 28 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Table 9. AC CHARACTERISTICS (Ta = - 40°C to 85°C or - 45°C to 125°C; VCC = 2.7-3.6V) Write (Erase/Program) Operations Parameter Symbols Speed Description JEDEC Standard -70 Unit tAVAV tWC Write Cycle Time (Note 1) Min 70 ns tAVWL tAS Address Setup Time Min 0 ns tWLAX tAH Address Hold Time Min 45 ns tDVWH tDS Data Setup Time Min 30 ns tWHDX tDH Data Hold Time Min 0 ns tOES Output Enable Setup Time Min 0 ns 0 ns tOEH Read Toggle and DATA# polling Read Recovery Time before Write (OE# High to WE# Low) MIn Output Enable Hold Time Min 10 ns Min 0 ns tGHWL tGHWL tELWL tCS CE# SetupTime Min 0 ns tWHEH tCH CE# Hold Time Min 0 ns tWLWH tWP Write Pulse Width Min 35 ns tWHDL tWPH Write Pulse Width High Min 20 ns tWHWH1 tWHWH1 Programming Operation (Word AND Byte Mode) (Note 2) Typ 8 µs Max 200 µs tWHWH2 tWHWH2 Erase Operation Sector Typ 0.1 s (Note 2) Chip Typ 2 s tVCS Vcc Setup Time Min 50 µs tVIDR Rise Time to VID Min 500 ns Recovery Time from RY/BY# min 0 ns Program/Erase valid to RY/BY# Delay Max 90 ns tRB tBusy Notes: 1. Not 100% tested. 2. See Erase and Programming Performance for more information. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 29 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Table 10. AC CHARACTERISTICS (Ta = - 40°C to 85°C or - 45°C to 125°C; VCC = 2.7-3.6V) Write (Erase/Program) Operations Alternate CE# Controlled Writes Parameter Symbols JEDEC Speed Description Standard -70 Unit tAVAV tWC Write Cycle Time (Note 1) Min 70 ns tAVEL tAS Address Setup Time Min 0 ns tELAX tAH Address Hold Time Min 45 ns tDVEH tDS Data Setup Time Min 30 ns tEHDX tDH Data Hold Time Min 0 ns tOES Output Enable Setup Time Min 0 ns Min 0 ns Min 10 ns Min 0 ns tGHEL tGHEL Output Read Enable Toggle and Hold Time Data# Polling Read Recovery Time before Write (OE# High to CE# Low) tWLEL tWS WE# Setup Time Min 0 ns tEHWH tWH WE# Hold Time Min 0 ns tELEH tCP Write Pulse Width Min 35 ns tEHEL tCPH Write Pulse Width High Min 20 ns tWHWH1 tWHWH1 Programming Operation (byte AND word mode) (Note 2) Typ 8 µs Max 200 µs tWHWH2 tWHWH2 Erase Operation Sector Typ 0.1 s (Note 2) Chip Typ 2 s tOEH tVCS Vcc Setup Time Min 50 µs tVIDR Rise Time to VID Min 500 ns tRB Recovery Time from RY/BY# min 0 ns tBusy Program/Erase valid to RY/BY# Delay Max 90 ns Notes: 3. Not 100% tested. 4. See Erase and Programming Performance for more information. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 30 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Table 11. ERASE AND PROGRAMMING PERFORMANCE Typ Limits Max Unit Sector Erase Time 0.1 2 sec Chip Erase Time 2 20 sec Byte Programming Time 8 200 µs Word Programming Time 8 200 µs Byte 8.4 25.2 Word 4.2 12.6 Parameter Chip Programming Time Erase/Program Endurance Comments Excludes 00H programming prior to erasure Excludes system level overhead sec 100K Minimum 100K cycles cycles Table 12. 48-PIN TSOP AND BGA PACKAGE CAPACITANCE Parameter Symbol Parameter Description Test Setup CIN Input Capacitance VIN = 0 Output Capacitance VOUT = 0 Control Pin Capacitance VIN = 0 B B COUT B CIN2 B B B B Package Typ Max TSOP 6 7.5 BGA 1.2 1.2 TSOP 8.5 12 BGA 1.1 1.2 TSOP 7.5 9 BGA 1.0 1.3 B B B B B Unit pF pF pF Note: Test conditions are Temperature = 25°C and f = 1.0 MHz. Table 13. DATA RETENTION Parameter Description Test Conditions Min Unit 150°C 10 Years 125°C 20 Years Data Retention Time This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 31 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C AC CHARACTERISTICS Figure 4. AC Waveforms for Chip/Sector Erase Operations Timings Erase Command Sequence (last 2 cycles) tAS tWC Addresses 0x2AA Read Status Data (last two cycles) tAH SA VA VA 0x555 for chip erase CE# tGHWL tCH OE# tWP WE# tWPH tCS 0x55 Data tDS tWHWH2 0x30 tDH tBUSY Status 10 for chip erase DOUT tRB RY/BY# VCC tVCS Notes: 1. SA=Sector Address (for sector erase), VA=Valid Address for reading status, Dout=true data at read address. 2. Vcc shown only to illustrate tvcs measurement references. It cannot occur as shown during a valid command sequence. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 32 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Figure 5. Program Operation Timings Program Command Sequence (last 2 cycles) tAS tWC Addresses 0x555 Program Command Sequence (last 2 cycles) tAH PA PA PA CE# tGHWL OE# tCH tWP WE# tWPH tCS Data OxA0 tDS RY/BY# tWHWH1 Status PD tDH DOUT tRB tBUSY tVCS VCC Notes: 1. PA=Program Address, PD=Program Data, DOUT is the true data at the program address. 2. VCC shown in order to illustrate tVCS measurement references. It cannot occur as shown during a valid command sequence. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 33 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Figure 6. AC Waveforms for /DATA Polling During Embedded Algorithm Operations tRC Addresses VA VA VA tACC tCH tCE CE# tOE OE# tOEH tDF WE# tOH DQ[7] Complement DQ[6:0] Status Data Comple -ment Status Data Valid Data True True Valid Data tBUSY RY/BY# Notes: 1. VA=Valid Address for reading Data# Polling status data 2. This diagram shows the first status cycle after the command sequence, the last status read cycle and the array data read cycle. Figure 7. AC Waveforms for Toggle Bit During Embedded Algorithm Operations tRC Addresses VA VA tCH VA VA tACC tCE CE# tOE OE# tOEH WE# tDF tOH Valid Status DQ6, DQ2 tBUSY (first read) Valid Status (second read) Valid Status Valid Data (stops toggling) RY/BY# This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 34 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Figure 8. Alternate CE# Controlled Write Operation Timings 0x555 for Program 0x2AA for Erase PA for Program SA for Sector Erase 0x555 for Chip Erase Addresses VA tWC tAS tAH WE# tWH tGHEL OE# tCP tWS CE# tDS tCPH tWHWH1 / tWHWH2 tBUSY tDH Data Status 0xA0 for Program 0x55 for Erase DOUT PD for Program 0x30 for Sector Erase 0x10 for Chip Erase RY/BY tRH Reset# Notes: PA = address of the memory location to be programmed. PD = data to be programmed at byte address. VA = Valid Address for reading program or erase status Dout = array data read at VA Shown above are the last two cycles of the program or erase command sequence and the last status read cycle Reset# shown to illustrate tRH measurement references. It cannot occur as shown during a valid command sequence. Figure 9. DQ2 vs. DQ6 Enter Embedded Erase WE# Enter Erase Suspend Program Erase Suspend Erase Erase Resume Enter Suspend Program Enter Suspend Read Erase Suspend Read Erase Erase Complete DQ6 DQ2 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 35 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Figure 10. Sector Protect/Unprotect Timing Diagram VID Vcc RESET# 0V 0V tVIDR tVIDR SA, A6,A1,A0 Data 60h Valid Valid Valid 60h 40h Status Sector Protect/Unprotect Verify CE# >0.4μS WE# >1μS Sector Protect: 150 uS Sector Unprotect: 15 mS OE# Notes: Use standard microprocessor timings for this device for read and write cycles. For Sector Protect, use A6=0, A1=1, A0=0. For Sector Unprotect, use A6=1, A1=1, A0=0. Temporary Sector Unprotect Parameter Std Speed -70 Unit Min 500 Ns Min 4 µs Description tVIDR VID Rise and Fall Time RESET# Setup Time for Temporary tRSP Sector Unprotect Notes: tRSP is Not 100% tested. Figure 11. Temporary Sector Unprotect Timing Diagram VID RESET# 0 or 3 V 0 or 3 V tVIDR tVIDR CE# WE# tRSP RY/BY# This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 36 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C FIGURE 12. 48L TSOP 12mm x 20mm package outline This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 37 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C FIGURE 13. 48L TFBGA 6mm x 8mm package outline SYMBOL This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 38 DIMENSION IN MM MIN. NOR MAX A --- --- 1.30 A1 0.23 0.29 --- A2 0.84 0.91 --- D 7.90 8.00 8.10 E 5.90 6.00 6.10 D1 --- 5.60 --- E1 --- 4.00 --- e --- 0.80 --- b 0.35 0.40 Note : 1. Coplanarity: 0.1 mm 0.45 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C ABSOLUTE MAXIMUM RATINGS Parameter Value Unit Storage Temperature -65 to +150 °C Plastic Packages -65 to +125 °C -55 to +125 °C 200 mA A9, OE#, Reset# 2 -0.5 to +11.5 V All other pins 3 -0.5 to Vcc+0.5 V Vcc -0.5 to +4.0 V Ambient Temperature With Power Applied Output Short Circuit Current1 Voltage with Respect to Ground Notes: 1. No more than one output shorted at a time. Duration of the short circuit should not be greater than one second. 2. Minimum DC input voltage on A9, OE#, RESET# pins is –0.5V. During voltage transitions, A9, OE#, RESET# pins may undershoot Vss to –1.0V for periods of up to 50ns and to –2.0V for periods of up to 20ns. See figure below. Maximum DC input voltage on A9, OE#, and RESET# is 11.5V which may overshoot to 12.5V for periods up to 20ns. 3. Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, inputs may undershoot Vss to –1.0V for periods of up to 50ns and to –2.0 V for periods of up to 20ns. See figure below. Maximum DC voltage on output and I/O pins is Vcc + 0.5 V. During voltage transitions, outputs may overshoot to Vcc + 1.5 V for periods up to 20ns. See figure below. 4. Stresses above the values so mentioned above may cause permanent damage to the device. These values are for a stress rating only and do not imply that the device should be operated at conditions up to or above these values. Exposure of the device to the maximum rating values for extended periods of time may adversely affect the device reliability. RECOMMENDED OPERATING RANGES1 Parameter Value Unit Ambient Operating Temperature Industrial Devices Automotive Devices -40 to 85 -45 to 125 °C Operating Supply Voltage Vcc 1. Full Voltage Range: 2.7 to 3.6 V Recommended Operating Ranges define those limits between which the functionality of the device is guaranteed. Vcc +1.5V Maximum Negative Overshoot Waveform Maximum Positive Overshoot Waveform This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 39 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C ORDERING INFORMATION EN29LV800C T - 70 T I P PACKAGING CONTENT P = RoHS compliant TEMPERATURE RANGE I = Industrial (-40°C to +85°C) A = Automotive (-45°C to +125°C) PACKAGE T = 48-pin TSOP B = 48-Ball Thin Fine Pitch Ball Grid Array (TFBGA) 0.80mm pitch, 6mm x 8mm package SPEED 70 = 70ns BOOT CODE SECTOR ARCHITECTURE T = Top Sector B = Bottom Sector BASE PART NUMBER EN = EON Silicon Solution Inc. 29LV = FLASH, 3V Read Program Erase 800 = 8 Megabit (1024K x 8 / 512K x 16) C = version identifier This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 40 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 www.eonssi.com EN29LV800C Revisions List Revision No Description Date A B C D 2008/06/06 2008/07/07 2008/7/17 2008/9/19 E F G H Preliminary draft Update 48 pin TSOP-I package outline on page 36 Modify Figure 5. AC Waveforms for READ Operations on page 27 Delete speed option -55R on datasheet 1. Add Eon products’ New top marking “cFeon“ information on page 1. 2. Add Automotive temperature information on page 2、39 and 40. 1. Update Erase and Program performance on page 2 and 31. 2. Modify Table 6 Status Register Bits DQ5 from ERROE BIT to TIME OUT BIT on page 18. 3. Modify IOH from -100mA to -100μA on page 24 4. Modify Test Conditions illustration on page 25. 5. Modify Storage Temperature from "-65 to + 125" to "-65 to +150" on page 39 6. Modify P = Pb free to P = RoHS compliant on page 40. Add standby current for Automotive (-45°C to +125°C) on page 24. 1. Correct the typo of VIH (max.) = Vcc + 0.3V on page 24. 2. Add BGA PACKAGE CAPACITANCE on page 31 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 41 © 2004 Eon Silicon Solution, Inc., Rev. H, Issue Date: 2011/10/26 2008/12/30 2009/03/13 2010/03/01 2011/10/26 www.eonssi.com