EVERLIGHT ALS-PDIC15

ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Features
‧Close responsively to the human eye spectrum
‧Light to Current, analog output
‧Good output linearity across wide illumination range
‧Low sensitivity variation across various light sources
‧Operating temperature performance, -40oC to 85oC
‧Wide supply voltage range, 2.5V to 5.5V
‧Size : 3.2mm(L)*1.5mm(W)*1.05mm(H)
‧RoHS compliant and Pb Free package
Description
ALS-PDIC15-21C/L230/TR8 Ambient Light Sensor Device, which incorporates a photodiode and a
current amplifier IC in a single chip, is a good effective solution to the power saving of display
backlighting of mobile appliances, such as the mobile phones and PDAs.
Due to the high rejection ratio of infrared radiation, the spectral response of the
ambient light sensor is close to human eyes.
Applications
‧Detection of ambient light to control display backlighting
Mobile devices – mobile phones, PDAs
Computing device – TFT LCD monitor for Notebook computer
Consumer device – TFT LCD TV, plasma TV, video camera, digital camera, toys
‧Automatic residential and commercial management
‧Automatic contrast enhancement for electronic signboard
‧Ambient light monitoring device for daylight and artificial light
– Street light, CCD/CCTV
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
1
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Package Dimensions
Unit: mm
Tolerances: ± 0.1mm
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
2
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Absolute Maximum Ratings (Ta=25℃)
Parameter
Symbol
Rating
Unit
Supply Voltage
Vcc
-0.5~6.0
V
Output Voltage
Vo
0 ~ Vcc-0.8
V
Output Photo Current
IPH
0~5
mA
Operating Temperature Range
Topr
-40 ~ +85
℃
Storage Temperature Range
Tstg
-40 ~ +100
℃
Tsol
260
℃
Human Body Model ESD
HBM
3000
V
Machine Model ESD
MM
300
V
Soldering Temperature Range [Note1]
Note1: For detail reflow time and the recommended temperature profile, please refer to page 8.
Recommended Operating Conditions (Ta=25℃)
Parameter
Symbol
Min.
Max.
Unit
Operating Temperature
Topr
-40
+85
℃
Supply Voltage
Vcc
2.5
5.5
V
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
3
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Electrical and Optical Characteristics (Ta=25℃)
Parameter
Symbol Min.
Typ.
Max.
Unit
Supply Current
Icc
-
1.2*IPH
-
μA
Dark Current
ID
-
-
100
nA
IPH1
3.6
-
9.5
μA
IPH2
36
-
95
μA
IPH3
-
78
-
μA
IPH4
360
-
950
μA
IPH3 / IPH2
-
1.2
-
-
Vo
2.20
2.35
-
V
λp
-
590
-
nm
Rise Time
tr
-
0.356
-
ms
Fall Time
tf
-
1.11
-
ms
Delay Time
td
-
2.2
-
ms
Storage Time
ts
-
0.692
-
ms
Light Current
Photocurrent Ratio
Saturation Output
Voltage
Peak Sensitivity
Wavelength
Switching
Time
Test Condition
Vcc=3V ;
Ev= 0Lux
Vcc=3V; Ev=10Lux
[Note1] [Fig.2]
Vcc=3V; Ev= 100Lux
[Note1] [Fig.2]
Vcc=3V; Ev= 100Lux
[Note2] [Fig.2]
Vcc=3V; Ev=1000Lux [Note1]
[Fig.2]
Vcc=3V; Ev= 100Lx,
RL=75KΩ Vcc=3V,RL=27KΩ
[Fig.3]
[Fig.4]
Note:
1. White Fluorescent light (Color Temperature = 6500K) is used as light source. However, White LED is
substituted in mass production.
2. Illuminance by CIE standard illuminant-A / 2856K, incandescent lamp.
Rankings
Rank
1
2
3
Test
Condition
VCC=3V;
Ev= 100Lx
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
Min
Max
36
60
50
80
65
95
4
Unit
uA
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Fig.1
Block Diagram
PDIC15-21C
2.Vcc
Vcc
2.
Current
Amp
1.Vout
Vout
1.
3.GND
GND
3.
4.
4.GND
GND
Fig.2
Measurement Method of
Light Current
Fig.3
ICC
Light
Source
Vcc
Vcc
APDIC15-21C
LS-001
Vout
Light
Source
ALS-001
AS-3021
PDIC15-21C
Vout
RL
IL
GND
Fig.4
Measurement Method of Saturation
Output Voltage
GND
Switching Time Measurement Method
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
5
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Typical Electrical and Optical Characteristics Curves
Fig.5
Light Current vs. Illuminance
Fig.6
Dark Current vs. Temperature
100000
Average dark current vs. Temperature
Average dark current (nA)
10000 Vcc = 3V , Ev= 0 Lux
1000
100
10
1
0.1
0.01
1E-3
-60
-40
-20
0
20
40
60
80
100
Temperature (℃ )
Fig.7
Light current vs. Temperature
1.10
Fig.8
1.30
Relative light current vs. Temperature
Vcc = 3V , Ev = 100 Lux
1.08
1.06
1.25
Relative light current vs. Supply voltage
Ev = 100Lux
1.20
1.02
Relative light current
Relative light current
1.04
Light current vs. Supply Voltage
1.00
0.98
0.96
0.94
0.92
0.90
0.88
0.86
1.15
1.10
1.05
1.00
0.95
0.84
-60
-40
-20
0
20
40
60
80
100
0.90
2.0
Temperature (℃ )
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
Supply voltage (V)
Fig.9
Spectral Response
Fig.10
1.2
8
T a = 25 ℃
7
6
0.8
Output voltage (V)
Relative sensitivity
1.0
Output voltage vs. Temperature
0.6
0.4
0.2
VCC = 3V
EV = 100 Lux
RL = 75KΩ
5
4
3
2
1
0.0
200
300
400
500
600
700
800
900
1000
1100
Wavelength (nm)
0
-60
-40
-20
0
20
40
60
80
100
Temperature (℃ )
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
6
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Fig.11
Output Voltage vs. Illuminance
10
Ta = 25 ℃
Vcc = 3V
Output voltage (V)
1
0.1
0.01
Fluorence light RL = 1 KΩ
Fluorence light RL = 7.5 KΩ
Fluorence light RL = 27 KΩ
Fluorence light RL = 75 KΩ
1E-3
1E-4
1
10
100
1000
10000
Illuminance (Lux)
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
7
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Converting Photocurrent to Voltage
Vcc
Current
Amp
Iph
Vout
RL
CL
GND
Note:
1. The output voltage (Vout) is the product of photocurrent (IPH) and loading resistor (RL)
2. A right loading resistor shall be chosen to meet the requirement of maximum ambient light,
and output saturation voltage:
Vout(max.) = Iout(max.) × RL ≦ Vout(saturation)=Vcc-0.8V
3. To avoid 60Hz ripple from fluorescent lamps, we suggest that the time constant must be
greater than 0.5 second:
RL × CL ≧ 0.5
(empirical data)
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
8
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Recommended method of storage
Reflow Terms:
JEDEC Level 2 Specification
Dry box storage is recommended as soon as the aluminum bag has been opened prevent
moisture absorption. The following conditions should be observed, if dry boxes are not available:
z
Storage temperature 10℃ to 30℃
z
Storage humidity ≦60%RH max
After more than one year under these conditions moisture content will be too high for Reflow soldering.
In case of moisture absorption, the devices will recover to former condition by drying under the following
condition:
192 hours at 40℃+5℃/-0℃ and 5%RH (dry air / nitrogen), or
96 hours at 60℃+5℃ and < 5%RH for all device containers, or
24 hours at 125℃+5℃ not suitable for reel or tubes
ESD Precaution:
Proper storage and handing procedures should be followed to prevent ESD damage to
the devices especially when they are removed from the Anti-static bag. Electro-Static Sensitive Devices
warning labels are on the packing.
Recommended Solder Profile
Notice:
(1) Reflow soldering should not be done more than two times.
(2) When soldering, do not put stress on the devices during heating.
(3) After soldering, do not warp the circuit board.
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
9
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Soldering Iron
Each terminal is to go to the tip of soldering iron temperature less than 350℃ for 3 seconds within once
in less than the soldering iron capacity 25W. Leave two seconds and more intervals, and do soldering
of each terminal. Be careful because the damage of the product is often started at the time of the hand
solder.
Repairing
Repair should not be done after the device have been soldered. When repairing is unavoidable, a
double-head soldering iron should be used (as below figure). It should be confirmed beforehand
whether the characteristics of the device will or will not be
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
10
damaged by repairing.
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Packing Quantity Specification
2000 PCS/ 1 Reel
Label Format
Pb
CPN: Customer’s Production Number
P/N : Production Number
QTY: Packing Quantity
CAT: Ranks
HUE: Peak Wavelength
REF: Reference
LOT No: Lot Number
EVERLIGHT
CPN :
P N : XXXXXXXXXXXXX
RoHS
XXXXXXXXXXXXX
QTY : XXX
CAT : XXX
HUE : XXX
REF : XXX
LOT NO : XXXXXXXXXX
MADE IN TAIWAN: Production Place
Reference : XXXXXXXX
Reel Dimensions
Unit: mm
Tolerance: ±0.1mm
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
11
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Tape Dimensions
Unit: mm
Tolerance: ±0.1mm
Moisture Resistant Packaging
Label
Label
Aluminum
moistue-proofbag
bag
Aluminum
moisture-proof
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
12
Desiccant
Desiccant
Label
Label
http://www.everlight.com
December 7, 2010
ALS-PDIC15-21C/L230/TR8
Surface-Mount
Ambient Light Sensor
Note:
1. Above specification may be changed without notice. EVERLIGHT will reserve authority on material
change for above specification.
2. When using this product, please observe the absolute maximum ratings and the instructions for
using outlined in these specification sheets. EVERLIGHT assumes no responsibility for any damage
resulting from use of the product which does not comply with the absolute maximum ratings and the
instructions included in these specification sheets.
3. These specification sheets include materials protected under copyright of EVERLIGHT Corporation.
Please don’t reproduce or cause anyone to reproduce them without EVERLIGHT’s consent.
Everlight Electronics Co., Ltd.
Document No: DLS-0000009 Rev 4
13
http://www.everlight.com
December 7, 2010