ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Features ‧Close responsively to the human eye spectrum ‧Light to Current, analog output ‧Good output linearity across wide illumination range ‧Low sensitivity variation across various light sources ‧Operating temperature performance, -40oC to 85oC ‧Wide supply voltage range, 2.5V to 5.5V ‧Size : 3.2mm(L)*1.5mm(W)*1.05mm(H) ‧RoHS compliant and Pb Free package Description ALS-PDIC15-21C/L230/TR8 Ambient Light Sensor Device, which incorporates a photodiode and a current amplifier IC in a single chip, is a good effective solution to the power saving of display backlighting of mobile appliances, such as the mobile phones and PDAs. Due to the high rejection ratio of infrared radiation, the spectral response of the ambient light sensor is close to human eyes. Applications ‧Detection of ambient light to control display backlighting Mobile devices – mobile phones, PDAs Computing device – TFT LCD monitor for Notebook computer Consumer device – TFT LCD TV, plasma TV, video camera, digital camera, toys ‧Automatic residential and commercial management ‧Automatic contrast enhancement for electronic signboard ‧Ambient light monitoring device for daylight and artificial light – Street light, CCD/CCTV Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 1 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Package Dimensions Unit: mm Tolerances: ± 0.1mm Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 2 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Absolute Maximum Ratings (Ta=25℃) Parameter Symbol Rating Unit Supply Voltage Vcc -0.5~6.0 V Output Voltage Vo 0 ~ Vcc-0.8 V Output Photo Current IPH 0~5 mA Operating Temperature Range Topr -40 ~ +85 ℃ Storage Temperature Range Tstg -40 ~ +100 ℃ Tsol 260 ℃ Human Body Model ESD HBM 3000 V Machine Model ESD MM 300 V Soldering Temperature Range [Note1] Note1: For detail reflow time and the recommended temperature profile, please refer to page 8. Recommended Operating Conditions (Ta=25℃) Parameter Symbol Min. Max. Unit Operating Temperature Topr -40 +85 ℃ Supply Voltage Vcc 2.5 5.5 V Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 3 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Electrical and Optical Characteristics (Ta=25℃) Parameter Symbol Min. Typ. Max. Unit Supply Current Icc - 1.2*IPH - μA Dark Current ID - - 100 nA IPH1 3.6 - 9.5 μA IPH2 36 - 95 μA IPH3 - 78 - μA IPH4 360 - 950 μA IPH3 / IPH2 - 1.2 - - Vo 2.20 2.35 - V λp - 590 - nm Rise Time tr - 0.356 - ms Fall Time tf - 1.11 - ms Delay Time td - 2.2 - ms Storage Time ts - 0.692 - ms Light Current Photocurrent Ratio Saturation Output Voltage Peak Sensitivity Wavelength Switching Time Test Condition Vcc=3V ; Ev= 0Lux Vcc=3V; Ev=10Lux [Note1] [Fig.2] Vcc=3V; Ev= 100Lux [Note1] [Fig.2] Vcc=3V; Ev= 100Lux [Note2] [Fig.2] Vcc=3V; Ev=1000Lux [Note1] [Fig.2] Vcc=3V; Ev= 100Lx, RL=75KΩ Vcc=3V,RL=27KΩ [Fig.3] [Fig.4] Note: 1. White Fluorescent light (Color Temperature = 6500K) is used as light source. However, White LED is substituted in mass production. 2. Illuminance by CIE standard illuminant-A / 2856K, incandescent lamp. Rankings Rank 1 2 3 Test Condition VCC=3V; Ev= 100Lx Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 Min Max 36 60 50 80 65 95 4 Unit uA http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Fig.1 Block Diagram PDIC15-21C 2.Vcc Vcc 2. Current Amp 1.Vout Vout 1. 3.GND GND 3. 4. 4.GND GND Fig.2 Measurement Method of Light Current Fig.3 ICC Light Source Vcc Vcc APDIC15-21C LS-001 Vout Light Source ALS-001 AS-3021 PDIC15-21C Vout RL IL GND Fig.4 Measurement Method of Saturation Output Voltage GND Switching Time Measurement Method Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 5 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Typical Electrical and Optical Characteristics Curves Fig.5 Light Current vs. Illuminance Fig.6 Dark Current vs. Temperature 100000 Average dark current vs. Temperature Average dark current (nA) 10000 Vcc = 3V , Ev= 0 Lux 1000 100 10 1 0.1 0.01 1E-3 -60 -40 -20 0 20 40 60 80 100 Temperature (℃ ) Fig.7 Light current vs. Temperature 1.10 Fig.8 1.30 Relative light current vs. Temperature Vcc = 3V , Ev = 100 Lux 1.08 1.06 1.25 Relative light current vs. Supply voltage Ev = 100Lux 1.20 1.02 Relative light current Relative light current 1.04 Light current vs. Supply Voltage 1.00 0.98 0.96 0.94 0.92 0.90 0.88 0.86 1.15 1.10 1.05 1.00 0.95 0.84 -60 -40 -20 0 20 40 60 80 100 0.90 2.0 Temperature (℃ ) 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Supply voltage (V) Fig.9 Spectral Response Fig.10 1.2 8 T a = 25 ℃ 7 6 0.8 Output voltage (V) Relative sensitivity 1.0 Output voltage vs. Temperature 0.6 0.4 0.2 VCC = 3V EV = 100 Lux RL = 75KΩ 5 4 3 2 1 0.0 200 300 400 500 600 700 800 900 1000 1100 Wavelength (nm) 0 -60 -40 -20 0 20 40 60 80 100 Temperature (℃ ) Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 6 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Fig.11 Output Voltage vs. Illuminance 10 Ta = 25 ℃ Vcc = 3V Output voltage (V) 1 0.1 0.01 Fluorence light RL = 1 KΩ Fluorence light RL = 7.5 KΩ Fluorence light RL = 27 KΩ Fluorence light RL = 75 KΩ 1E-3 1E-4 1 10 100 1000 10000 Illuminance (Lux) Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 7 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Converting Photocurrent to Voltage Vcc Current Amp Iph Vout RL CL GND Note: 1. The output voltage (Vout) is the product of photocurrent (IPH) and loading resistor (RL) 2. A right loading resistor shall be chosen to meet the requirement of maximum ambient light, and output saturation voltage: Vout(max.) = Iout(max.) × RL ≦ Vout(saturation)=Vcc-0.8V 3. To avoid 60Hz ripple from fluorescent lamps, we suggest that the time constant must be greater than 0.5 second: RL × CL ≧ 0.5 (empirical data) Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 8 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Recommended method of storage Reflow Terms: JEDEC Level 2 Specification Dry box storage is recommended as soon as the aluminum bag has been opened prevent moisture absorption. The following conditions should be observed, if dry boxes are not available: z Storage temperature 10℃ to 30℃ z Storage humidity ≦60%RH max After more than one year under these conditions moisture content will be too high for Reflow soldering. In case of moisture absorption, the devices will recover to former condition by drying under the following condition: 192 hours at 40℃+5℃/-0℃ and 5%RH (dry air / nitrogen), or 96 hours at 60℃+5℃ and < 5%RH for all device containers, or 24 hours at 125℃+5℃ not suitable for reel or tubes ESD Precaution: Proper storage and handing procedures should be followed to prevent ESD damage to the devices especially when they are removed from the Anti-static bag. Electro-Static Sensitive Devices warning labels are on the packing. Recommended Solder Profile Notice: (1) Reflow soldering should not be done more than two times. (2) When soldering, do not put stress on the devices during heating. (3) After soldering, do not warp the circuit board. Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 9 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Soldering Iron Each terminal is to go to the tip of soldering iron temperature less than 350℃ for 3 seconds within once in less than the soldering iron capacity 25W. Leave two seconds and more intervals, and do soldering of each terminal. Be careful because the damage of the product is often started at the time of the hand solder. Repairing Repair should not be done after the device have been soldered. When repairing is unavoidable, a double-head soldering iron should be used (as below figure). It should be confirmed beforehand whether the characteristics of the device will or will not be Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 10 damaged by repairing. http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Packing Quantity Specification 2000 PCS/ 1 Reel Label Format Pb CPN: Customer’s Production Number P/N : Production Number QTY: Packing Quantity CAT: Ranks HUE: Peak Wavelength REF: Reference LOT No: Lot Number EVERLIGHT CPN : P N : XXXXXXXXXXXXX RoHS XXXXXXXXXXXXX QTY : XXX CAT : XXX HUE : XXX REF : XXX LOT NO : XXXXXXXXXX MADE IN TAIWAN: Production Place Reference : XXXXXXXX Reel Dimensions Unit: mm Tolerance: ±0.1mm Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 11 http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Tape Dimensions Unit: mm Tolerance: ±0.1mm Moisture Resistant Packaging Label Label Aluminum moistue-proofbag bag Aluminum moisture-proof Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 12 Desiccant Desiccant Label Label http://www.everlight.com December 7, 2010 ALS-PDIC15-21C/L230/TR8 Surface-Mount Ambient Light Sensor Note: 1. Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above specification. 2. When using this product, please observe the absolute maximum ratings and the instructions for using outlined in these specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these specification sheets. 3. These specification sheets include materials protected under copyright of EVERLIGHT Corporation. Please don’t reproduce or cause anyone to reproduce them without EVERLIGHT’s consent. Everlight Electronics Co., Ltd. Document No: DLS-0000009 Rev 4 13 http://www.everlight.com December 7, 2010