Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Features ‧Close responsively to the human eye spectrum ‧Light to Current, analog output ‧Good output linearity across wide illumination range ‧Low sensitivity variation across various light sources ‧Operating temperature performance, -40 C to 85 C ‧Wide supply voltage range, 1.8V to 5.5V ‧Size : 1.6mm(L)*1.6mm(W)*0.55mm(H) ‧RoHS compliant, Pb Free and halogen free package o o Description The ALS-PDIC17-77C/TR8 is consisting of a photodiode and a current amplification IC. EVERLIGHT ALS series product is a good effective solution to the power saving of display backlighting of mobile appliances, such as the mobile phones, NB and PDAs. Due to the high rejection ratio of infrared radiation, the spectral response of the ambient light sensor is close to that of human eyes. Applications ‧Detection of ambient light to control display backlighting Mobile devices – mobile phones, PDAs Computing device – TFT LCD monitor for Notebook computer Consumer device – TFT LCD TV, Plasma TV, Video camera, Digital camera, Toys ‧Automatic residential and commercial management ‧Automatic contrast enhancement for electronic signboard ‧Ambient light monitoring device for daylight and artificial light – Street light, CCD/CCTV Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 1 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Package Dimensions Top View Bottom View Unit: mm Tolerances: ±0.1mm Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 2 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Absolute Maximum Ratings (Ta=25°C) Parameter Symbol Rating Unit Supply Voltage Vcc -0.5~6.0 V Output Voltage Vo 0 ~ Vcc-0.8 V Output Photo Current IPH 0~5 mA Operating Temperature Range Topr -40 ~ +85 °C Storage Temperature Range Tstg -40 ~ +100 °C Soldering Temperature Range [Note1] Tsol 260 °C Note1: For detail reflow time and the recommended temperature profile, please refer to page 9. Recommended Operating Conditions (Ta=25°C) Parameter Symbol Min. Max. Unit Operating Temperature Topr -40 +85 °C Supply Voltage Vcc 1.8 5.5 V Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 3 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Electrical and Optical Characteristics (Ta=25°C) Parameter Symbol Min. Typ. Max. Unit Test Condition Vcc = 3V, Ev = 1000Lux RL = 1kΩ [Note2] Vcc=3V Ev= 0Lux Supply Current Icc - 480 950 µA Dark Current ID - - 100 nA IPH1 2.7 4 5.4 µA IPH2 27 40 54 µA Vcc=3V; Ev= 100Lux IPH3 - 48 92 µA Vcc=3V; Ev= 100Lux IPH4 - 400 540 µA Vcc=3V; Ev=1000Lux IPH3 / IPH2 - 1.2 1.7 - Vo 2.20 2.35 - V λp - 550 - nm Rise Time tr - 11 1000 µs Fall Time tf - 400 2000 µs Delay Time td - 250 - µs Storage Time ts - 35 - µs Vcc=3V; Ev=10Lux [Note1] [Note1] Light Current Photocurrent Ratio Saturation Output Voltage Peak Sensitivity Wavelength Switching Time [Note2] [Note1] Vcc=3V; Ev= 100Lx, RL=150KΩ Vcc=3V,RL=5kΩ [Fig.3] [Fig.4] Note: 1. Fluorescent light (Color Temperature = 6500K) is used as light source. However, White LED is substituted in mass production. 2. Illuminance by CIE standard illuminant-A 2856K of incandescent lamp. Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 4 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Fig.1 Block Diagram PDIC15-21C PDIC17-77C 2.1.V Vcccc Current Amp Vout 1.6. Vout 2. GND 3.3. GND GND 4. GND 4. GND 5. GND Fig.2 Measurement Method of Light Current Vcc Vcc ICC Light Source Fig.3 Measurement Method of Saturation Output Voltage Light Source Vout ALS-001 PDIC17-77C RL IL GND Fig.4 Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 Vout ALS-001 AS-3021 PDIC17-77C GND Switching Time Measurement Method 5 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Typical Electrical and Optical Characteristics Curves Fig.5 Light Current vs. Illuminance Fig.6 Dark Current vs. Temperature 10000 Fluorescent light Incandescent lamp Light current (uA) 1000 100 10 1 0.1 1 10 100 1000 10000 Illuminance (Lux) Fig.7 Light current vs. Temperature Fig.8 1.6 2.0 ℃ Ta = 25 1.4 1.2 1.0 0.8 0.6 0.4 1.2 0.8 0.4 0.2 0.0 -60 -40 -20 0 20 40 ℃) 60 80 0.0 100 2 3 4 Fig.9 5 6 7 Supply voltage (V) Temperature ( Fig.10 Spectral Response Output Voltage vs. Illuminance 10 Vcc = 3V Ta = 25 ℃ 1 Output voltage (V) Relative light current 1.6 VCE = 3V EV = 100 Lux Relative light current 1.8 Light current vs. Supply Voltage Fluorescent light RL = 5.1 kΩ Incandescent lamp RL = 5.1 kΩ Fluorescent light RL = 30 kΩ Incandescent lamp RL = 30 kΩ Fluorescent light RL = 100 kΩ Incandescent lamp RL = 100 kΩ 0.1 0.01 1E-3 1 10 100 1000 10000 Illuminance (Lux) Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 6 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Fig.11 Consumption current vs. Illuminance Fig.12 Relative consumption current vs. Temperature 1000 1.4 ℃ Relative consumption current Consumption current (uA) Vcc = 3V Ta = 25 100 10 RL = 5.1 kΩ RL = 50 kΩ RL = 100 kΩ 1 0.1 1 10 100 1000 1.2 1.0 0.8 0.6 -40 10000 Vcc = 3V Ev = 100 Lux RL= 1kΩ -20 0 Illuminance (Lux) 20 40 ℃) 60 80 100 Temperature ( Converting Photocurrent to Voltage Vcc Current Amp Iph Vout RL CL GND Note: 1. The output voltage (Vout) is the product of photocurrent (IPH) and loading resistor (RL) 2. A right loading resistor shall be chosen to meet the requirement of maximum ambient light and output saturation voltage: Vout(max.) = Iout(max.) × RL ≦ Vout(saturation)=Vcc-0.6V 3. To avoid 60Hz ripple from fluorescent lamps, we suggest that the time constant must be greater than 0.5 second: RL × CL ≧ 0.5 Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 (empirical data) 7 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Recommended method of storage 1. Do not open moisture proof bag before devices are ready to use. 2. Shelf life in sealed bag from the bag seal date: 18 months at 10°C~30°C and < 90% RH. 3. After opening the package, the devices must be stored at 10°C~30°C and ≤ 60%RH, and used within 1 year (floor life). 4. If the moisture absorbent material (desiccant material) has faded or unopened bag has exceeded the shelf life or devices (out of bag) have exceeded the floor life, baking treatment is required. 5. If baking is required, refer to IPC/JEDEC J-STD-033 for bake procedure or recommend the following conditions: 192 hours at 40°C +5/–0°C and < 5 % RH (reeled/tubed/loose units) or 96 hours at 60°C ± 5°C and < 5 % RH (reeled/tubed/loose units) or 24 hours at 125°C ± 5°C, not suitable for reel or tubes. Recommended Solder Profile Notice: (1) Reflow soldering frequency is based on JEDEC-020D. (2) When soldering, do not put stress on the devices during heating. (3) After soldering, do not warp the circuit board. Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 8 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Soldering Iron Each terminal is to go to the tip of soldering iron temperature less than 350 ℃ for 3 seconds within once in less than the soldering iron capacity 25W. Leave two seconds and more intervals, and do soldering of each terminal. Be careful because the damage of the product is often started at the time of the hand solder. Repairing Repair should not be done after the device have been soldered. When repairing is unavoidable, a double-head soldering iron should be used (as below figure). It should be confirmed beforehand whether the characteristics of the device will or will not be Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 9 damaged by repairing. http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Packing Quantity Specification 3000 PCS/ 1 Reel Label Format CPN: Customer’s Production Number P/N : Production Number QTY: Packing Quantity CAT: Ranks HUE: Peak Wavelength REF: Reference LOT No: Lot Number MADE IN TAIWAN: Production place MADE IN TAIWAN Reel Dimensions Unit: mm Tolerance: ±0.1mm Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 10 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Tape Dimensions Progressive direction Unit: mm Tolerances: ±0.1mm Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 11 http://www.everlight.com Jun. 20, 2011 Surface - Mount Ambient Light Sensor ALS-PDIC17-77C/TR8 Note: 1. Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above specification. 2. When using this product, please observe the absolute maximum ratings and the instructions for using outlined in these specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these specification sheets. 3. These specification sheets include materials protected under copyright of EVERLIGHT corporation. Please don’t reproduce or cause anyone to reproduce them without EVERLIGHT’s consent. Everlight Electronics Co., Ltd. Document No: DLS-0000025 Rev4 12 http://www.everlight.com Jun. 20, 2011