EXTECH 382096

1000A 3-Phase Power & Harmonics Analyzer
For power measurements and analysis
Of single and 3-phase/3-wire or 3-phase/4-wire systems
Features:
• Large backlighting LCD displays up to
35 parameters in one screen (3P4W)
• Clamp-on True RMS power
measurements with on-screen
Harmonics display (1-99th order)
• Simultaneous display of
Harmonics and Waveform
• Display of Waveform with
Peak Values (1024 samples/period)
• Analysis of Total Harmonic Distortion
(THD-F)
• Displays Active Power (kW), Apparent
Power (kVA), Reactive Power (kVAR) and
Power Factor
• kWH and kVARh energy measurements
• Maximum Demand (MDkW, MW, kVA,
MVA) with programmable period
• Adjustable CT ratio (1 to 600) and
VT ratio (1 to 3000)
• Graphic Phase diagram with
3-Phase system parameters
• 3-phase Voltage or Current Unbalanced
Ratio (VUR, VIR) and Unbalanced Factor
(d0%, d2%)
• Calculated Unbalanced Current
through Neutral Line (In)
• Datalogger records up to 52428 records
in single phase,
(17476 records in 3-phase)
• Capture 28 Transient events
(including Dip, Swell and Outage) with
programmable threshold (%)
• Optically isolated RS-232 interface
with software to download Waveforms,
Power Parameters and Harmonics
Optional 3000A Flexible Current
Clamp Probes 24" (610mm) long
for wrapping around busbars
(Model 382098)
Optional 100A Current Clamp
Probes (Model 382097) with
1.2" (30mm) jaw size
Optional Thermal Printer (PR20)
prints text or graphics with fixed
intervals or continuous
Complete with (3) 1000A current clamps, 4 voltage leads with alligator clips,
8 AA batteries, AC adaptor, software, PC interface cable, and carrying case
Specifications
ACV (True rms)
ACA
Active Power (kW)
Apparent Power (kVA)
Reactive Power (kVAR)
Power Factor
Frequency
Phase
Harmonics
Crest Factor
Peak AC Voltage accuracy
Peak AC Current accuracy
Active Power Energy (kWh)
Reactive Power Energy (kVARh)
Datalogging
Dimensions
Weight
Harmonics Analysis
Phase Analysis
Range
600V
1000A
9.999MW
9999kVA
9999kVAR
0.0 to +1.00
45-65Hz
-180.0°~ 0°~ +180.0°
1 to 99
1.00 to 99.99
Basic Accuracy
±(0.5%rdg+5d)
±(0.5%rdg+5d)
±(1%rdg+8d)
VA=Vrms x Arms
VAR= sqr (VA2-W2)
±(1.5%°rdg±8d)
0.1Hz
±1°
±2%
±(5%+30d)
±(5%rdg+30d)
±(5%rdg+30d)
0mWh to 999,999kWh
0.0kVARh to 1000MWh
52428 records (single phase)/17476 records (3 phase)
10.1 x 6.1 x 2.3" (257 x 155 x 57mm)
Meter: 2.5 lbs (1160g); Clamp: 1.3 lbs (600g)
Power Analysis
Internal Menu
Ordering Information:
382095 ........1000A 3-Phase Power Harmonics Analyzer (110V)
382096 ........1000A 3-Phase Power Harmonics Analyzer (220V)
Accessories
382000 ........Voltage Test Leads with Alligator Clips (4 leads)
382097 ........100A Current Clamp Probes (Set of 3)
382098 ........3000A, Flexible Current Probes (Set of 3)
PR20 ............Portable Thermal Printer
757057 ........Thermal Paper for PR20 (6 pack)
USB100 ........RS-232 to USB Adaptor
www.extech.com
Software included to download,
store data and display on a PC
Software Harmonics
Phase Analysis
Software Harmonics Analysis
Specifications subject to change without notice.
6/5/08 - R1
Copyright © 2007 -2008 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.