FUJI EDS8-49E

FCX SERIES FIELD INDICATOR
DATA SHEET
FXE
This is a field installation type moving-coil indicator which
receives and indicates signal of 4 to 20 mA DC. It is employed
when an indicator is to be installed separately from the
transmitter.
SPECIFICATIONS
Functional Specifications
Measured input: 4 to 20mA DC (2-wire type)
Internal impedance:
Scale:
3.5 Ω or less
0 to 100% linear scale or 0 to 100%
square scale, actual scale
Note: Double scale is unavailable.
50mm
Scale length:
Environmental protection:
IEC IP67 and NEMA4X
Explosionproof structure:
Case material:
Finish color:
Intrinsic safety BASEEFA EExiaIICT4,
T5(pending)
Flameproofing JIS d2G4
Aluminum alloy
Epoxy urethane double coating
Silver (case cover is blue-silver)
SCOPE OF DELIVERY
Ambient temperature:
– 40 to +85°C
For explosionproof units, ambient temperature must be within the limits specified
by each standard.
Ambient humidity:
Indicator and pipe mounting bracket (as specified)
CODE SYMBOLS
100% RH or less
Storage temperature:
– 40 to +90°C
Approx. 3.5kg
Mass:
Conduit connection:
G1/2, 1/2– 14NPT, Pg13.5 or M20 x 1.5
conduit, as specified
External terminal:
Input signal terminal x 2, ground terminal
x 1, M4mm screw
Mounting method:
Mounting on 50A (2B) pipe or on wall
Outer dimensions (H x W x D): 92 x 222 x
179mm
[Performance Specifications]
Accuracy:
± 1.5 class
Withstand voltage:
500V AC, 50/60 Hz, for 1 minute, to ground
Insulation resistance:
1 2 3 4 5 6 7 8
F X E
9 10 11 12
Description
0 0 0 1 -
Conduit connection
G1/2
1/2-14NPT
Pg13.5
M20 x 1.5
S
T
V
W
Scale
0 to 100% linear scale
0 to 100% square scale
Actual scale
B
C
D
Explosionproof structure
General type (non-explosionproof)
JIS flameproof (conduit seal type)(*)
JIS flameproof (cable seal type)(*)
BASEEFA Intrinsic safety
A
B
C
K
A
B
C
100MΩ or more at 500V DC, to ground
Y
B
Pipe mounting bracket
Not provided
Provided (steel)
Provided (stainless steel)
Stainless steel tag plate
None
Yes
Note: *10th code B, C is only applicable for 4th
codes.
EDS8-49e
Date
Jan. 18, 2003
FXE
OUTLINE DIAGRAM (Unit:mm)
1Mounting pipe
JIS 50A(2B)
U-bolt M8
55
70
φ92
φ92
Up
Down
Field indicator
88
Clamp(only with flame proof
type)
4-φ9 holes
38
58
*Cable gland
(for flame proof,
cable seal type only)
184
*"B"Conduit connection
"A" Conduit
connection
179
60
Details of "A"
66
Details of "B"
φ13
17
E
E
4th
code
S
164
G
φ15
G1/2
F
G
G1/2
E
17
8
T
1/2-14NPT
16
5
V
Pg13.5
W
M20 × 1.5
8
70
120
4.5
16
5
Note: Asterisked(*) items are provided only with
flameproof(cable seal type) type. φ11mm cable
should be used.
EXTERNAL CONNECTION DIAGRAM
Case 1
Case 2
FCX
Transmitter
+
Field indicator
FXE
CK+
+
Field indicator
FXE
CK+
Power
supply
FCX
Transmitter
+
CK+
+
-
CK-
-
Power
supply
-
CK-
-
CK-
Short bar
Note: Maximum three(3) indicators in
series can be connected to the
transmitter terminals CK+,CK-.
Note: Maximum three(3) indicators in series
can be connected between the power
supply and the transmitter.
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
http://www.fesys.co.jp/eng
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http: //www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan