FC SERIES INTEGRATOR DATA SHEET PKE This is a 6-digit analog integrator which displays an integral upon receiving FC SERIES signals or signals from slide rheostat. FEATURES 1. Accuracy of ± 0.5%. 2. A variety of integral levels are available for free choice, optimum for process lines. 3. The instrument permits transmitting pulses up to 10 times as many as the integral level selected. The integrator can easily be connected to a computer through a remote data transmission system. The output stage is prepared in three types for optional choice in accordance with practical requirements. SPECIFICATIONS Measuring signal :FC SERIES signal DC 1 to 5V DC 4 to 20mA Wiring resistance :5Ω or less per wire Circuit resistance adjustment unneces sary (for slide rheostat) Input resistance :1MΩ (DC 1 to 5V) 250Ω (DC 4 to 20mA) Allowance : Input 5 to 100% Within ±0.5%of rating Display mode Integral level Input less than 5% Within ±1% of rating Rated value means the theoretical value to be obtained when 100% input is continuously applied and integrated. :Decimal 6-digit electromagnetic counter (with click-touch reset pushbutton) :Value to be integrated for 1 hour at 100% input: 50 100 200 250 300 400 500 600 750 800 900 1000 1200 1500 1600 1800 2000 Power supply :DC24V (20 to 30V or AC 100V 10%, 50/60 Hz) Power consumption: Approx. 6W (DC 24V) Approx. 9VA (AC 100V) (including power consumption by pulse transmitter) Power indicator lamp: Rectangular green LED Ambient temperature: 0 to 45˚C Ambient humidity: 90% RH (MAX) Enclosure :Steel case External dimensions (HxWxD): 144 x 72 x 400 mm (casing) + terminal board Mass (weight) :Approx. 4.5kg Finish color :Munsell 7Y 7.3/1.4 EDS10-12e Date Jan. 6, 2006 PKE Optional devices : Pulse transmitter Number of transmission pulses : Integral x 1, 2, 5, 10 Output contact ; 1a contact (excluding semi-conductor output contact) Type of contact ; Relay contact Contact capacity AC 100V, 0.3A/DC 24V, 0.2A (resistive load) Dielectric strength between contact and ground : AC 500V for 1 min Contactless pulse* Integration cutoff : Integration starts at 10% or higher when input is increased from 0% +0% Accuracy of cutoff point: –0.5% Hysteresis: 1% or iess Scope of delivery : Integrator and mounting bracket Mounting: Panel flush mounting = 90 to 60° Output stage of semiconductor contact Load current; 50mA or less Dielectric strength Between PO+ and ground AC 500V for 1 min Between PO+ and PO-: DC 33V BASIC OPERATING PRINCIPLE DIAGRAM Reset pushbutton V/f F–F Input terminal Pulse transmission Pulse transmitter 0 to 100Hz check terminal 2 CODE SYMBOLS 1 2 3 4 5 6 7 8 P KE 9 10 Description 2 Allowance ±0.5% 1 Input signal DC 1 to 5V DC 4 to 20mA A B Integral level Integral per hour at 100% input V ~ U Code Integral Code Integral Code Integral V W A B C E 50 100 200 250 300 400 F G J K L M 500 600 750 800 900 1000 N R S T U 1200 1500 1600 1800 2000 Power supply DC 24V AC 100V 50/60Hz 1 3 Integration cutoff None Cutoff at 10% 0 1 Pulse transmitter Pulse width (make time) : 80 to 200ms Type Specifications for contact A Multiplication 1 Relay contact B C 2 5 " " D 10 " • Contact capacity: DC 24V, 0.2A, DC48V, 0.1A AC 100V, 0.3A, AC 200V, 0.15A • Service life: Mechanical 50 million operations, electrical 10 million operations • Dielectric strength: AC 1000V for 1 min between contact and ground * J 1 * K 2 * L 5 " 10 " Contactless pulse " • Dielectric strength P0+ P0- Between PO+ and ground: AC 500V for 1 min Between PO+ and PO-: DC 33V * M Y • Load current: 50mA None * Asterisked (*) items: Nonstandard 3 PKE OUTLINE DIAGRAM (Unit : mm) + Input Resistance 100 0% Power supply DC 24V (or AC 100V) Voltage Current Check terminal (C-: ground) - P0+ P0C+ C- G 10 1+ I- Pc Vp 11 10 9 8 7 6 5 4 3 2 1 CONNECTION DIAGRAM Pulse output (option) Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan