Agilent L4411A ‘Low profile’ 6½ Digit Multimeter Leading the Industry in High-Performance System Test Product Overview Agilent L4411A 6½-Digit HighPerformance DMM • 50,000 readings/sec @ 4½ digits direct to PC • 10,000 readings/sec @ 5½ digits direct to PC • 1,000 readings/sec @ 6½ digits direct to PC • Analog level triggering • Programmable pre/post triggering • LAN extensions for instruments (LXI), USB & GPIB standard • 30 PPM 1 year basic DC accuracy • DCV, ACV, DCI, ACI, 2-wire and 4-wire resistance, frequency, period, and diode test • Capacitance & temperature measurements • Expanded measurement ranges A new standard for modular system DMMs The L4411A 6½ digit high performance DMM expands Agilent’s industry leading offering of LXI system products. For the test system integrator looking for the next generation modular DMM, this new meter offers the industry’s best measurement speed and throughput, a reduced size (1 rack unit high), superior measurement performance, and a choice of computer interfaces, including LXI, providing high performance, easy to use, economical I/O. A simple display, including ‘latest reading’ and LAN address, allows the system integrator to quickly integrate and debug the test system. And finally, the DMM comes with a compatibility mode, requiring little-to-no code change to upgrade your test system with next generation capabilities. Dramatic system performance Whether it’s raw reading speed or fast system throughput, the L4411A sets a new benchmark in performance. Using a new A/D technology, the L4411A achieves an impressive 50,000 readings a second at 4½ digits, and can stream readings to your computer at this same speed! Transactional I/O (single reading— measurement and PC transfer time) is 3x faster than other popular modular DMMs, significantly enhancing your test throughput. Triggering is fast and precise, with both trigger latency and trigger jitter less than 1 µs, while bus query response is less than 500 µs. ACV measurements are faster as well thanks to a digital measurement technique that additionally improves accuracy at high and low frequencies. LXI—Class C LAN Extensions for Instruments (LXI) provides the next generation I/O for system applications requiring high throughput. Transfer rates of over 250,000 readings/sec are attainable ensuring even the most data intensive measurements are fast, without the overhead cost of an instrument mainframe. LXI provides a built-in Graphical Web Interface that allows you to interactively control the DMM without the hassle of programming, making it great for debugging your system. The L4411A DMM is LXI — Class C compliant. Enhanced measurement capabilities The L4411A offers temperature and capacitance capabilities in addition to those measurements you have come to expect such as DCV, ACV, DCI, ACI, 2-wire and 4-wire resistance, frequency, period and diode test. You also get offset compensated Ohms, allowing you to accurately measure resistance in the presence of voltages. Measurement ranges have been expanded as well; for example, DC and AC current ranges now go down to 100 µA, resulting in 100 pA resolution. Real-time math and statistics are included, and a peak-detect capability allows you to capture peaks as short as 20 µs. System integration When deciding on your next system DMM you can’t go wrong with the L4411A. Choose from LAN (LXI), USB or GPIB interfaces, all standard on the L4411A, to connect to your computer. The 1U size is perfect for space constrained applications like aerospace/defense depot test. Concerned about the viability of your existing software programs? This new DMM responds to standard commands for programmable instrumentation (SCPI). Additionally there is a 34401A/E1412A emulation mode to ensure the easiest upgrade possible, virtually eliminating costly software and documentation changes. The autoranging power supply allows you to connect to any input power without selecting input voltages or changing fuses. Agilent’s I/O Library Suite ships with the L4411A to help you quickly establish an error-free connection between your PC and instrument. It provides robust instrument control and works with the software development environment you choose. DMM dimensions (mm) 212.3 363.2 Companion LXI switch modules Need a switch to route your signal to the L4411A? Consider Agilent’s LXI switch modules. Choose from a 40-channel armature relay multiplexer (L4421A), a dual/quad 4x8 reed relay matrix (L4433A) or a 32-channel Form A/C general purpose relay switch module (L4437A). Additionally, Agilent has LXI DAC, digital I/O and multifunction modules to help complete your test system requirements. All from the leader in LXI instrumentation, Agilent Technologies. Built to last Our new DMM was designed to high standards of ruggedness and reliability. From the robust, compact package to careful selection of components and conservative circuit design, this meter is built to last. Calculated mean time between failure (MTBF) is in excess of 100,000 hours. Backed by a 1-year warranty and a worldwide network of service centers, you can buy with confidence. Go to the web For the latest information on these or other Agilent DMMs, go to www.agilent.com/find/dmm 2 40.9 Accessories included: Test report, power cord, LAN cross-over interface cable. Product reference CD-ROM (34410-13601) • Software ◦ IntuiLink software ◦ IVI-COM driver ◦ LabView driver ◦ Example programs • Online documentation ◦ Programmer’s reference ◦ Getting started guide ◦ User’s guide ◦ Service guide ◦ Localized manuals Agilent I/O Libraries CD-ROM (E2094-60003) Accuracy Specifications ± (% of reading + % of range) 1 Function Range 3 DC voltage 100.0000 mV 1.000000 V 10.00000 V 100.0000 V 1000.000 V 4 100.0000 mV to 750.000 V True RMS AC voltage 5 Resistance 6 DC current True RMS AC current 7 Frequency or period Capacitance 8 100.0000 Ω 1.000000 kΩ 10.00000 kΩ 100.0000 kΩ 1.000000 MΩ 10.00000 MΩ 100.0000 MΩ 1.000000 GΩ 100.0000 µA 1.000000 mA 10.00000 mA 100.0000 mA 1.000000 A 3.000000 A 100.0000 µA to 3.00000 A 100 mV to 750 V 1.0000 nF 10.000 nF 100.00 nF 1.0000 µF 10.000 µF Temperature 9 RTD -200 °C to 600 °C Thermistor -80 °C to 150 °C 1.0000 V Diode test 10 Frequency, test current or burden voltage 24 hour 2 Tcal ±1°C 0.0030 + 0.0030 0.0020 + 0.0006 0.0015 + 0.0004 0.0020 + 0.0006 0.0020 + 0.0006 3 Hz – 5 Hz 0.50 + 0.02 5 Hz – 10 Hz 0.10 + 0.02 10 Hz – 20 kHz 0.02 + 0.02 20 kHz – 50 kHz 0.04 + 0.025 50 kHz – 100 kHz 0.10 + 0.040 100 kHz – 300 kHz 1.00 + 0.250 1 mA 0.0030 + 0.0030 1 mA 0.0020 + 0.0005 100 µA 0.0020 + 0.0005 10 µA 0.0020 + 0.0005 5 µA 0.0020 + 0.0010 500 nA 0.0100 + 0.0010 500 nA || 10 MΩ 0.200 + 0.001 500 nA || 10 MΩ 2.000 + 0.001 < 0.03 V 0.010 + 0.020 < 0.30 V 0.007 + 0.006 < 0.03 V 0.007 + 0.020 < 0.30 V 0.010 + 0.004 < 0.80 V 0.050 + 0.006 < 2.0 V 0.100 + 0.020 3 Hz – 5 kHz 0.10 + 0.04 5 kHz – 10 kHz 0.20 + 0.04 3 Hz – 5 Hz 0.070 + 0.000 5 Hz – 10 Hz 0.040 + 0.000 10 Hz – 40 Hz 0.020 + 0.000 40 Hz – 300 kHz 0.005 + 0.000 500 nA 0.50 + 0.50 1 µA 0.40 + 0.10 10 µA 0.40 + 0.10 10 µA 0.40 + 0.10 100 µA 0.40 + 0.10 1 mA 0.06 °C 0.08 °C 0.002 + 0.010 1. Specifications are for 90 minute warm-up and 100 PLC. 2. Relative to calibration standards. 3. 20% overrange on all ranges, except DCV 1000 V, ACV 750 V, DCI and ACI 3 A ranges. 4. For each additional volt over ± 500 V add 0.02 mV of error. 5. Specifications are for sinewave input > 0.3% of range and > 1 mVrms. Add 30 µV error for frequencies below 1 kHz. 750 VAC range limited to 8 x 107 Volts-Hz. For each additional volt over 300 Vrms add 0.7 mVrms of error. 6. Specifications are for 4-wire resistance measurements, or 2-wire using Math Null. Without Math Null, add 0.2 Ω additional error in 2-wire resistance measurements. 90 day Tcal ±5°C 1 year Tcal ±5°C Temperature coefficient/°C 0 °C to (Tcal -5°C) (Tcal +5°C) to 55°C 0.0040 + 0.0035 0.0030 + 0.0007 0.0020 + 0.0005 0.0035 + 0.0006 0.0035 + 0.0006 0.50 + 0.03 0.10 + 0.03 0.04 + 0.02 0.08 + 0.025 0.20 + 0.040 1.20 + 0.250 0.008 + 0.004 0.007 + 0.001 0.007 + 0.001 0.010 + 0.001 0.030 + 0.001 0.600 + 0.001 6.000 + 0.001 0.0050 + 0.0035 0.0035 + 0.0007 0.0030 + 0.0005 0.0040 + 0.0060 0.0040 + 0.0060 0.50 + 0.03 0.10 + 0.03 0.045 + 0.02 0.090 + 0.025 0.200 + 0.040 1.200 + 0.250 0.010 + 0.004 0.010 + 0.001 0.010 + 0.001 0.012 + 0.001 0.040 + 0.001 0.800 + 0.001 8.000 + 0.001 0.040 + 0.025 0.030 + 0.006 0.030 + 0.020 0.030 + 0.005 0.080 + 0.010 0.120 + 0.020 0.10 + 0.04 0.20 + 0.04 0.070 + 0.000 0.040 + 0.000 0.020 + 0.000 0.006 + 0.000 0.50 + 0.50 0.40 + 0.10 0.40 + 0.10 0.40 + 0.10 0.40 + 0.10 0.050 + 0.025 0.050 + 0.006 0.050 + 0.020 0.050 + 0.005 0.100 + 0.010 0.150 + 0.020 0.10 + 0.04 0.20 + 0.04 0.070 + 0.000 0.040 + 0.000 0.020 + 0.000 0.007 + 0.000 0.50 + 0.50 0.40 + 0.10 0.40 + 0.10 0.40 + 0.10 0.40 + 0.10 0.0005 + 0.0005 0.0005 + 0.0001 0.0005 + 0.0001 0.0005 + 0.0001 0.0005 + 0.0001 0.010 + 0.003 0.008 + 0.003 0.005 + 0.002 0.010 + 0.0025 0.020 + 0.0040 0.120 + 0.0200 0.0006 + 0.0005 0.0006 + 0.0001 0.0006 + 0.0001 0.0006 + 0.0001 0.0010 + 0.0002 0.0030 + 0.0004 0.1000 + 0.0001 1.0000 + 0.0001 0.0020 + 0.0030 0.0020 + 0.0005 0.0020 + 0.0020 0.0020 + 0.0005 0.0050 + 0.0010 0.0050 + 0.002 0.015 + 0.006 0.030 + 0.006 0.005 + 0.000 0.005 + 0.000 0.001 + 0.000 0.001 + 0.000 0.05 + 0.05 0.05 + 0.01 0.01 + 0.01 0.01 + 0.01 0.01 + 0.01 0.06 °C 0.08 °C 0.008 + 0.020 0.06 °C 0.08 °C 0.010 + 0.020 0.003 °C 0.002 °C 0.0010 + 0.0020 7. Specifications are for sinewave input > 1% of range and > 10 µArms. Frequencies > 5 kHz are typical for 1 A and 3 A ranges. 8. Specifications are for 1-hour warm-up using Math Null. Additional errors may occur for non-film capacitors. 9. For total measurement accuracy, add temperature probe error. 10. Accuracy specifications are for the voltage measured at the input terminals only. 1 mA test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction. 3 A-to-D converter noise performance Resolution (ppm of range) 1 Normal mode rejection (dB) 2 Readings/second 4 0.001 0.002 0.006 0.02 0.06 0.2 1 2 10 100 30 15 6 3 1.5 0.7 0.3 0.2 0.1 0.03 0 0 0 0 0 0 55 110 3 110 3 110 3 50,000 25,000 10,000 3,000 1,000 300 60 (50) 30 (25) 6 (5) 0.6 (0.5) 100 RMS noise (ppm of range) Integration time (NPLC) 10 1 0.1 0.01 0.001 0.01 0.1 1 10 100 1. Resolution is defined as the typical DCV 10 V range RMS noise. Auto-zero on for NPLC ≥ 1. See manual for additional noise characteristics. 2. Normal mode rejection for power line frequency ± 0.1%. 3. For power-line frequency ± 1% 75 dB and for ± 3% 55 dB. 4. Maximum rate with auto-zero off for 60 Hz and (50 Hz) operation. System reading and throughput rates DMM memory to PC (maximum reading rate out of memory) 1 Drawing – Path B LAN (VXI-11) readings/sec LAN (sockets) readings/sec 4,000 89,000 47,000 8,500 265,000 154,000 7,000 110,000 60,000 8,500 270,000 160,000 ASCII 32-bit binary 64-bit binary Direct I/O measurements (single reading – measure and I/O time) 1 Drawing – Path C Function Resolution (NPLC) GPIB msec DCV/2-wire 0.001 resistance ACV/ Fast filter frequency 1 ms gate USB 2.0 LAN LAN msec (VXI-11) (sockets) msec msec (readings/sec) Drawing–Path A or C 2.6 2.9 4.6 3.2 50,000 10.0 10.0 10.0 10.0 500 System performance DCV/2-wire resistance ACV/frequency Range change Auto-range LAN/GPIB (msec) 3 2 (msec) Path ‘A’ DMM input ADC Maximum reading rate into memory or to direct I/O 1. ½ scale input signal, immediate trigger, trigger delay 0, auto-zero off, auto-range off, no math, null off, 60 Hz line frequency. See manual for performance on other functions. Function change (msec) 1 System reading architecture Maximum external trigger rate Maximum internal trigger rate 22 3.9/2.6 7.5 5,000/s 50,000/s 37 6.5/6.4 19 500/s 500/s 1. Time to change from 2-wire Resistance to this specified function, or DCV to 2-wire resistance using the SCPI ”FUNC” command 2. Time to change from one range to the next higher range, ≤ 10 V, ≤ 10 MΩ 3. Time to automatically change one range and be ready for the new measurement, ≤ 10 V, ≤ 10 MΩ 4 Path ‘C’ L4411A/ 34410A/ DMM memory 34411A 50 k readings DMM non-volatile PC GPIB USB 2.0 readings/sec LAN GPIB readings/sec USB Reading format Path ‘B’ Measurement Characteristics DC voltage Measurement method: Linearity: (10 V range) Input resistance: Frequency and period Continuously integrating multi-slope IV A/D converter 0.0002% of reading + 0.0001% of range 0.1 V, 1 V, 10 V ranges 100 V, 1000 V ranges Measurement method: Reciprocal-counting technique. AC-coupled input using the AC voltage measurement function. Input impedance: 1 MΩ ± 2% in parallel with < 150 pF Input protection: 750 Vrms all ranges 10 MΩ or > 10 GΩ (selectable) 10 MΩ ±1% (fixed) Capacitance Measurement method: Connection type: Input bias current: < 50 pA at 25 °C Input protection: 1000 V DC CMRR: 140 dB 1 Temperature True RMS AC voltage Thermistor: RTD: Measurement method: Crest factor: AC-coupled True RMS measurement. Digital sampling with anti-alias filter. No additional error for crest factors < 10. Limited by peak input and 300 kHz bandwidth. Peak input: 300% of range or 1100 V Overload Will select higher range if peak input ranging: overload is detected during auto range. Overload is reported in manual ranging. AC CMR: 70 dB 2 Maximum input: 400 Vdc, 1100 Vpk Input impedance: 1 MΩ ± 2% in parallel with < 150 pF Input protection: 750 Vrms all ranges Response time: Continuity threshold: Input protection: Maximum readings/second Digits 4.5 Function 3 DCV 50 k 2-wire Ω 50 k DCI 50 k Frequency 500 Period 500 Filter setting fast ACV 500 ACI 500 Selectable 2-wire or 4-wire. Current source referenced to LO input. Selectable on the 100 Ω, 1 kΩ, and 10 kΩ ranges 10% of range per lead for 100 Ω, 1 kΩ. 1 kΩ per lead on all other ranges 1000 V on all ranges Current shunt: Maximum input: Input protection: 5.5 10 k 10 k 10 k 90 90 med 150 150 6.5 1k 1k 1k 10 10 slow 50 50 Additional specifications Resolution: Overall bandwidth, DCV & DCI: Triggering: Timebase resolution: Trigger jitter: 200 Ω for 100 µA, 1 mA 2 Ω for 10 mA, 100 mA 0.1 Ω for 1 A, 3 A 3 A, 250 V fuse True RMS AC current Measurement method: 300 samples/sec Fixed at 10 Ω Operating characteristics DC current Current shunt: 2.2 kΩ, 5 kΩ, and 10 kΩ α = 0.00385 Ro from 49 Ω to 2.1 kΩ Diode test Resistance Measurement method: Offset compensation: Max. lead resistance (4-wire): Input protection: Current input with measurement of resulting ramp. 2-wire AC-coupled true RMS measurement. Directly coupled to the fuse and shunt. Digital sampling with anti-alias filter. 200 Ω for 100 µA, 1 mA 2 Ω for 10 mA, 100 mA 0.1 Ω for 1 A, 3 A The peak value of the DC + AC current must be < 300% of range. The RMS current must be < 3 A including the DC current content. 3 A, 250 V fuse See table on page 4 15 kHz typical @ 20 µs aperture (-3 dB) Pre/Post, Analog Level, Int/Ext, Pos/Neg 19.9524 µs 0.01% accuracy 2 µs (p-p), 20 µs (p-p) when pre-triggered 1. For 1 kΩ unbalanced in LO lead, ± 500 V peak maximum 2. For 1 kΩ unbalanced in LO lead and < 60 Hz, ± 500 V peak maximum 3. Maximum rate for DCV, DCI, and resistance functions (using zero settling delay, autozero off, manual range) 5 Ordering Information Spurious-free dynamic range & signal to noise distortion ratio Agilent L4411A Multimeter Function DCV Accessories included Range 1V 10 V 1 100 V Spur-free -75 dB -70 dB -75 dB SNDR 60 dB 60 dB 60 dB Test report, power cord, LAN cross-over interface cable. Product reference CD-ROM (34410-13601): 1. 10 V range: 2 V (p-p) <signal< 16 V (p-p) • Software ◦ IntuiLink software ◦ IVI-COM driver ◦ LabView driver ◦ Example programs • Online documentation ◦ Programmer’s reference ◦ Getting started guide ◦ User’s guide ◦ Service guide ◦ Localized manuals Triggering and memory Reading hold sensitivity: Samples per trigger: Trigger delay: External trigger: 1% of reading 1 to 1,000,000 0 to 3600 sec (20 µs step size) Programmable edge, low-power TTL compatible Delay: < 1 µs Jitter: < 1 µs Max rate: 5,000/sec Min pulse width: 1 µs Voltmeter 3 V logic output, 2 µs pulse with complete: programmable edge Nonvolatile 50,000 readings memory: Volatile memory: 1,000,000 readings Sample timer: Range: 0 to 3600 s (20 µs step sizes) Jitter: < 100 ns Agilent I/O Libraries CD-ROM (E2094-60003) Options Opt. STD Opt. 001 Opt. ABA Opt. 0B0 Opt. A6J General specifications Power supply: Power line frequency: Power consumption: Operating environment: Storage temperature: Weight: Dimensions: Safety: 90 V – 264 V @ 45-66 Hz 90 V – 134 V @ 360 – 440 Hz Automatically sensed at power-on Rear measurement terminals ONLY Front measurement terminals ONLY Printed manual set (English) Delete printed manual set (full documentation included on CD ROM) ANSI Z540 compliant calibration Agilent accessories Y1133A Y1160A 50 VA peak (18 W average) Full accuracy for 0 °C to 55 °C, 80% R.H. at 40 °C non-condensing -40 °C to 70 °C 11059A 11060A 11062A 34171B 34172B 34330A E2308A 1.9 kg (4.25 Lbs) (W x H x D) 40.9 mm x 212.3 mm x 363.2 mm IEC 61010-1, EN 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1, refer to Declarations of Conformity for current revisions. Measurement CAT II 300V, CAT I 1000V. Pollution Degree 2 EMC: IEC 61326, EN 61326, CISPR 11, ICES-001, AS/NZS 2064.1, refer to Declaration of Conformity for current revisions. Vibration & shock: MIL-T-28800E, Type III, Class 5 (Sine only) LXI compliance: LXI Class C, ver. 1.0 Warranty: 1 year 6 Measurement & trigger cable kit Rack mount kit for L4400A series instruments racks 1 or 2 instruments side-by-side on sliding tray Kelvin probe set Surface mount device (SMD) test probes Kelvin clip set Input terminal connector (sold in pairs) Input calibration short (sold in pairs) 30 A current shunt 5 kΩ thermistor probe www.agilent.com www.agilent.com/find/L4411A www.agilent.com/find/dmm Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Product specifications and descriptions in this document subject to change without notice. For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Latin America United States (877) 894-4414 305 269 7500 (800) 829-4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 €/minute Germany 07031 464 6333** Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus © Agilent Technologies, Inc. 2009 Printed in USA, January 30, 2009 5989-6303EN