Triacs INCHANGE BTA16-600B Features ·With TO-220AB Insulated package ·This type is suitable for general purpose AC switching, and can be used as an ON/OFF function in applications such as static relays, heating regulation, induction motor starting circuits... or for phase control operation in light dimmers, motor speed controllers,etc QUICK REFERENCE DATA SYMBOL VALUE UNIT VDRM Repetitive peak off-state voltage 600 V VRRM Repetitive peak off-state voltage 600 V IT(AV) Average on-state current 16 A ITSM Non-repetitive peak on-state current 160 A Tstg Storage temperature -45~150 ℃ 110 ℃ Tj PARAMETER Operating junction temperature TO-220AB ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified) SYMBOL PARAMETER VDRM Repetitive peak off-state voltage ID=0.1mA 600 V VRRM Repetitive peak reverse voltage ID=0.5mA 600 V IGT CONDITIONS MIN MAX VD =12V; RL = 100Ω T2+ G+ 50 T2+ G- 50 T2- G- 50 T2- G+ 100 Gate trigger current UNIT mA VT On-state voltage IT=22.5A 1.6 V IH Holding current IT=0.5A; IGT =50m A 50 mA VD =12V; RL = 100Ω T2+ G+ 1.5 T2+ G- 1.5 T2- G- 1.5 T2- G+ 1.8 VGT Gate trigger voltage V