TIGER ELECTRONIC CO.,LTD Product specification BTA/BTB41-600B 40A TRIACS GENERAL DESCRIPTION Available either in through-hole or surface-mount packages, the BTA/BTB41 - 600B triac series is suitable for general purpose AC switching. They can be used as an ON/OFF function in applications such as static relays, heating regulation, induction motor starting circuits... or for phase control operation in light dimmers, motor speed controllers, ... The snubberless versions (BTA/BTB...W series) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL standards. O ABSOLUTE MAXIMUM RATINGS ( Ta = 25 C) PARAMETER Symbol Value Unit Repetitive peak off-state voltages VDRM 600 V peak off-state reverse voltages VRRM 600 V IT 40.0 A ITSM 420 A Tj 110 o Tstg -45~150 o RMS on-state current Non-repetitive peak on-state current Max. Operating Junction Temperature Storage Temperature A1 A2 G C TO-3P C O ELECTRICAL CHARACTERISTICS ( Ta = 25 C) PARAMETER Symbol Test Conditions Repetitive peak off-state voltages VDRM ID=0.1mA Repetitive peak off-state current IDRM VDRM=520V On-state voltage VTM IT=60A Holding current IH T2+G- Current T2-G- Max 600 IT=0.5A,IGT=50mA T2+G+ Gate trigger Min. V 10 uA 1.55 V 80 mA 50 IGT 50 VAK=12V RL=30 mA 50 T2-G+ 100 T2+G+ 1.3 Gate trigger T2+G- Voltage T2-GT2-G+ Unit VGT VD=12V RL=30 1.3 1.3 1.3 V