MAKE-PS 212D12VFI

www.make-ps.com
E-mail:[email protected]
200VFI series
Single & Dual Output
DC/DC Converter
FEATURES
•
•
•
•
•
•
Single and Dual Output, 2 watt converter
4000 VAC Input/Output Isolation
Available in 5, 12, and 24 VDC Inputs
Wide Operating Temperature Range
MTBF > 600,000 Hours
Low Cost
DESCRIPTIONS
INPUT CHARACTERISTICS
The 200VFI series is a family of cost effective 2 watt single
and dual output DC/DC converters. 18 models operate from
input bus voltages of 5V, 12V and 24V; producing output
voltage levels of 5V, 12V, 15V, ±5V, ±12V and ±15V for a wide
range of choices.
Min Typ
Input Voltage
5 VDC Input Models
4.5 5
12 VDC Input Models 10.8 12
24 VDC Input Models 13.5 24
Input Fuse Requirements
5 VDC Input Models
1000
12 VDC Input Models
500
24 VDC Input Models
250
Input Filter
The 200VFI series is ideal for a variety of applications
including distributed power systems, mixed analog / digital
subsystems, portable test equipment, local power networks
and battery backed systems.
Max Unit/Comments
5.5
13.2
26.4
VDC
VDC
VDC
mA; Slow blow type
mA; Slow blow type
mA; Slow blow type
Pi Filter
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Balance
(Duals)
Line Regulation
Load Regulation
Ripple/Noise
Ripple/Noise
Overload Protection
Short Circuit Protection
Temperature Coefficient
Min Typ Max Unit/Comments
±2.0 ±4.0 % Output voltage at
nominal line & FL
±2.0 ±4.0 % Equal Output
Loads
±0.3 ±0.5 %; % Change /
Percentage change
in Input
voltage
±0.5 ±1.0 % Output voltage
measured from FL
to 10% load
30 50 mV p-p, Nom.Line
@FL, 20MHz B.W.,
using 1 μf bypass
capacitor
100 mV p-p, Over Line,
Load & Temp., 20
MHz B.W.,
using 1 μf bypass
capacitor
%Rated Output Load
120
Continuous
±0.01 ±0.02 % per degree C
GENERAL CHARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
Min Typ Max Unit/Comments
kHz
25
50
80
VDC, 60 sec.
6,000
Mohm, 500VDC
10,000
20
30 pF, 100kHz, 1Volt
Million Hours,
0.6
+25oC, Ground
Benign
>> B-33
www.make-ps.com
E-mail:[email protected]
ENVIRONMENTAL SPECIFICATIONS
Operating Temp. Range
Operating Temp. Range
Storage Temp. Range
Relative Humidity
PHYSICAL CHARACTERISTICS
Typ Max
+60
+90
+125
+95
Min
-25
-25
-40
Cooling
Unit/Comments
o
C; Ambient
o
C; Case
o
C
% Humidity; noncondensing
Free-Air Convection
Unit/Comments
1.25 X 0.80 X 0.40 inches
(31.8 X 20.3 X 10.2 mm)
Non-Conductive Black Plastic
UL94V-0
12.4 Grams
Case Size
Case Material
Flammability
Weight
OUTLINE DRAWING
1.25 (31.8)
0.40
(10.2)
SIDE VIEW
0.15
(3.8)
0.020(0.50)
PIN DIA.
0.100
(2.54)
0.10
(2.5)
0.08 (2.0)
1 2
10 11 12
0.600 0.80
(15.22) (20.3)
BOTTOM VIEW
24 23
15
13
PIN OUT CHART
Pins
1
2
10
11
12
13
15
23
24
Single
+ Vin
+ Vin
No Pin
No Pin
- Vout
+ Vout
No Pin
- Vin
- Vin
Dual
+ Vin
+ Vin
Common
Common
No Pin
- Vout
+ Vin
- Vin
- Vin
Notes:
1. Unless otherwise specified dimensions are in inches (mm).
Tolerances
Inches
mm
X.XX = ±0.02
X.X = ±0.5
X.XXX= ±0.010
X.XX = ±0.25
Pin :
±0.002
±0.05
All specifications are typical at nominal input, nominal load and 25° C unless otherwise specified.
External, low ESR, 10 microfarad (minimum) capacitor across input is recommended for operation.
>> B-34
www.make-ps.com
E-mail:[email protected]
HOW TO ORDER
HOW TO ORDER
2 XX S XX VFI - Y
ROHS Compliant
Series
Nominal
Input Voltage
Wattage=2 W
Output Voltage
Output
Configuration
(S=Single, D=Dual)
MODEL SELECTION CHART
Model
205S5VFI
212S5VFI
215S5VFI
205S12VFI
212S12VFI
215S12VFI
205S24VFI
212S24VFI
215S24VFI
205D5VFI
212D5VFI
215D5VFI
205D12VFI
212D12VFI
215D12VFI
205D24VFI
212D24VFI
215D24VFI
Nominal
Input
Voltage
(VDC)
5
5
5
12
12
12
24
24
24
5
5
5
12
12
12
24
24
24
Output
Voltage
(VDC)
5
12
15
5
12
15
5
12
15
±5
±12
±15
±5
±12
±15
±5
±12
±15
Full Load
Output
Current
(mA)
400
165
133
400
165
133
400
165
133
±100
±83
±66
±100
±83
±66
±100
±83
±66
No Load
Input
Current
(mA)
100
100
100
50
50
50
30
30
30
100
100
100
50
50
50
30
30
30
Full Load
Input
Current
(mA)
645
629
623
269
262
260
134
131
130
476
699
695
185
281
280
93
143
142
Reflected
Ripple
Current
(mA)
62
63
64
62
63
64
62
63
64
42
57
57
45
59
59
45
58
58
>> B-35
www.make-ps.com
E-mail:[email protected]
DERATING CURVES
MODEL 200VFI
Pout %
100
90
80
70
60
50
40
30
20
10
0
-25
100LFM
200LFM
Natural
Convection
400LFM
~
50
60
70
80
90
100
110
TEMPERATURE ° C
>> B-36