MEANWELL HDP

HDP-240
240W Dual Output with PFC Function
Features :
Universal AC input / Full range
Built-in active PFC function, PF 0.94
High efficiency up to 84%
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
1U low profile 36mm
Conformal coated
Built-in cooling fan ON-OFF control
ZVS technology to reduce power dissipation
LED indicator for power on
3 years warranty
SPECIFICATION
MODEL
HDP-240
OUTPUT NUMBER
V1
DC VOLTAGE
+3.8V
+2.8V
RATED CURRENT
41.5A
25A
CURRENT RANGE (max.)
0 ~ 50A
RATED POWER
227.7W (typ.)
OUTPUT POWER (max.)
OUTPUT
V2
0 ~ 27.5A
241W (max.)
241W continue. V1 total power output shall not exceed 200W (max. 50A) ; V2 total power output shall not exceed 82.5W (max. 27.5A)
(The V1 & V2 combine total power output shall not exceed 241W)
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
VOLTAGE ADJ. RANGE Note.6 3.6 ~ 4V
VOLTAGE TOLERANCE Note.3 2.0%
2.5 ~ 3V
2.0%
LINE REGULATION
0.5%
LOAD REGULATION
2.0%
0.5%
2.0%
SETUP, RISE TIME
1000ms, 50ms/230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
VOLTAGE RANGE
Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
127 ~ 370VDC
POWER FACTOR (Typ.)
PF 0.94/230VAC
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
84%
3.3A/115VAC
1.3A/230VAC
INRUSH CURRENT (Typ.)
30A/115VAC
45A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
V1+V2: 105 ~ 150% max. output power ; or V2: 125 ~ 170% rated current
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
FUNCTION
2500ms, 50ms/115VAC at full load
FAN CONTROL (Typ.)
WORKING TEMP.
PF 0.98/115VAC at full load
Protection type: Hiccup mode, recovers automatically after fault condition is removed
V2: 3.22 ~ 3.78V
V1: 4.37 ~ 5.13V
Protection type : Shut down o/p voltage, re-power on to recover
80
5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recovery
RTH4 50 Fan on ; RTH4 45 Fan off
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
111.3K hrs min.
DIMENSION
215*115*36mm (L*W*H)
1Kg; 15pcs/16Kg/0.7CUFT
PACKING
NOTE
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Output voltage between V1 and V2 should be higher than 0.8V(V1-V2 0.8V).
File Name:HDP-240-SPEC 2012-02-29
HDP-240
240W Dual Output with PFC Function
Mechanical Specification
Case No.206A
Unit:mm
215
204.5
97.5
150
32.5
24
15.85
SVR1
33.5
Terminal Pin No. Assignment :
Assignment Pin No.
AC/L
4,5
AC/N
6,7
8,9,10,11
FG
SVR1: V1(+3.8V)ADJ.
SVR2: V2(+2.8V)ADJ.
44.75
34.4
Assignment
V2(+2.8V)
V1(+3.8V)
COM
10
32.5
47.45
115
108
95
50
Pin No.
1
2
3
16
3.5
9.5
135
8.3
11
10 LED
9
8
7
4-M4 L=5mm
6 SVR2
5
4
3
2
5-M3 L=3mm
1
15
215
150
32.5
16max.
12.5
36
Air flow
direction
4-M4 L=5mm
Block Diagram
FAN
ON/OFF
CONTROL
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
RECTIFIERS
&
PFC
POWER
SWITCHING
O.T.P.
O.L.P.
PFC fosc : 65KHz
PWM fosc : 80KHz
RECTIFIERS
&
FILTER
+V1
COM
POWER
SWITCHING
DETECTION
CIRCUIT
FG
PFC
CONTROL
FAN
PWM
CONTROL
O.V.P.
+V2
O.L.P.
PWM
CONTROL
DETECTION
CIRCUIT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
100
90
80
80
70
50
LOAD(%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
95
100
115
130
145
165
185
205
225
245
264
INPUT VOLTAGE (V) 60Hz
File Name:HDP-240-SPEC 2012-02-29