MEANWELL RP-300-5

HRP-300
300W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89% (typ.)
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
1U low profile 41mm
Built-in cooling fan ON-OFF control
With DC OK signal output
Built-in remote sense function
5 years warranty
SPECIFICATION
MODEL
OUTPUT
HRP-300-3.3
HRP-300-5
HRP-300-7.5
HRP-300-12
HRP-300-15
HRP-300-24
HRP-300-36
HRP-300-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
60A
60A
40A
27A
22A
14A
9A
7A
CURRENT RANGE
0 ~ 60A
0 ~ 60A
0 ~ 40A
0 ~ 27A
0 ~ 22A
0 ~ 14A
0 ~ 9A
0 ~ 7A
RATED POWER
198W
300W
300W
324W
330W
336W
324W
336W
RIPPLE & NOISE (max.) Note.2 80mVp-p
90mVp-p
100mVp-p
120mVp-p
150mVp-p
150mVp-p
250mVp-p
250mVp-p
VOLTAGE ADJ. RANGE
4.3 ~ 5.8V
2.0%
6.8 ~ 9V
2.0%
10.2 ~ 13.8V
1.0%
13.5 ~ 18V
1.0%
21.6 ~ 28.8V
1.0%
28.8 ~ 39.6V
1.0%
40.8 ~ 55.2V
1.0%
2.8 ~ 3.8V
VOLTAGE TOLERANCE Note.3 2.5%
LINE REGULATION
0.5%
0.5%
0.5%
0.3%
0.3%
0.2%
0.2%
0.2%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
VOLTAGE RANGE
Note.5 85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
PF>0.95/230VAC
EFFICIENCY (Typ.)
80%
82%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
5A/115VAC
35A/115VAC
2.5A/230VAC
70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC
OVER VOLTAGE
PF>0.99/115VAC at full load
86%
88%
88%
87%
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
6 ~ 7V
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
3.96 ~ 4.62V
88%
89%
41.4 ~ 48.6V
57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
90
FUNCTION
120 ~ 370VDC
POWER FACTOR (Typ.)
OVERLOAD
PROTECTION
2500ms, 50ms/115VAC at full load
OVER TEMPERATURE
100
(TSW1: detect on heatsink of power transistor)
5
5
for 3.3V,5V,7.5V ; 95
5
for others (TSW2: detect on heatsink of power diod e)
DC OK SIGNAL
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
FAN CONTROL (Typ.)
Load 35 15% or RTH2
WORKING TEMP.
-30 ~ +70
50
Fan on
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 4)
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
OTHERS
/ 70% RH
EMS IMMUNITY
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
176K hrs min.
DIMENSION
199*105*41mm (L*W*H)
0.95Kg;15pcs/15.3Kg/0.69CUFT
PACKING
NOTE
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:HRP-300-SPEC 2009-11-09
HRP-300
300W Single Output with PFC Function
Mechanical Specification
Unit:mm
18 12.5
Case No.980A
series
4-M4 L=6
12.25
168.5
168.5
R2
199
12.25
.25
168.5
120
42.5
18
1.5
HOLE IN CHASSIS
4.5
1
4-M4 L=5
11
2
3
6
7
LED
CN100
SVR
Connector Pin No. Assignment (CN100) :
HRS DF11-08DP-2DS or equivalent
Pin No. Assignment
1,2,4,6
NC
DC-OK
3
5
GND
+S
7
-S
8
Terminal
Mating Housing
167.5
12.25
167.5
12.25
17max.
12.5 18
41
HRS DF11-**SC
or equivalent
HRS DF11-8DS
or equivalent
4-M4 L=6
fosc : 70KHz
Block Diagram
+S
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
Air flow
direction
15
1 7
Assignment
Pin No.
DC OUTPUT -V
4,5
6,7
DC OUTPUT +V
2 8
Assignment
AC/L
AC/N
FG
Pin No.
1
2
3
FAN
5
75
105
125
9.2
4
Terminal Pin No. Assignment
RECTIFIERS
&
PFC
POWER
SWITCHING
O.T.P.
O.L.P.
PFC
CONTROL
PWM
CONTROL
RECTIFIERS
&
FILTER
+V
-V
-S
FG
Derating Curve
DC OK
DETECTION
CIRCUIT
O.V.P.
Output Derating VS Input Voltage
Ta = 25
100
100
90
80
80
70
50
LOAD(%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
85
100
125
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:HRP-300-SPEC 2009-11-09