HRP-200 200W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit 1U low profile 38mm Built-in remote sense function 5 years warranty SPECIFICATION MODEL OUTPUT HRP-200-3.3 HRP-200-5 HRP-200-7.5 HRP-200-12 HRP-200-15 HRP-200-24 HRP-200-36 HRP-200-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 40A 35A 26.7A 16.7A 13.4A 8.4A 5.7A 4.3A CURRENT RANGE 0 ~ 40A 0 ~ 35A 0 ~ 26.7A 0 ~ 16.7A 0 ~ 13.4A 0 ~ 8.4A 0 ~ 5.7A 0 ~ 4.3A RATED POWER 132W 175W 200.3W 200.4W 201W 201.6W 205.2W 206.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 90mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p VOLTAGE ADJ. RANGE 4.3 ~ 5.8V 2.0% 6.8 ~ 9V 2.0% 10.2 ~ 13.8V 1.0% 13.5 ~ 18V 1.0% 21.6 ~ 28.8V 1.0% 28.8 ~ 39.6V 1.0% 40.8 ~ 55.2V 1.0% VOLTAGE TOLERANCE Note.3 2.8 ~ 3.8V 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 1.5% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load Note.5 85 ~ 264VAC VOLTAGE RANGE FREQUENCY RANGE 47 ~ 63Hz INPUT 120 ~ 370VDC POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 80% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.2A/115VAC 35A/115VAC LEAKAGE CURRENT <1.2mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE 2500ms, 50ms/115VAC at full load PF>0.99/115VAC at full load 84% 86% 88% 88% 88% 89% 89% 1.1A/230VAC 70A/230VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 3.96 ~ 4.62V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) detect on heatsink of power transistor OVER TEMPERATURE 105 WORKING TEMP. Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -30 ~ +70 (Refer to output load derating curve) 5 (TSW2) detect on main power output choke 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMS IMMUNITY Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, heavy industry level, criteria A MTBF 209.4K hrs min. DIMENSION 199*98*38mm (L*W*H) 0.77Kg; 18pcs/14.9Kg/0.81CUFT PACKING NOTE I/P-FG:1.5KVAC ISOLATION RESISTANCE HARMONIC CURRENT OTHERS I/P-O/P:3KVAC MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:HRP-200-SPEC 2010-05-12 HRP-200 200W Single Output with PFC Function Mechanical Specification Case No.902E series Unit:mm 3.5 9 7 197 1 9.5 2 80 5 8.2 85.5 4 98 3 6 7 Assignment Pin No. DC OUTPUT -V 4,5 DC OUTPUT +V 6,7 4- M 3 57.5 4.5 120 199 6.5 9.5 Mating Housing 18.5 Pin No. Assignment NC 1 2 NC 3 NC 4 NC +S 5 -S 6 190 9 Connector Pin No. Assignment (CN100) : HRS DF11-6DP-2DS or equivalent Terminal 5 18 3. 13max. 150.75 M3 28 3- HRS DF11-6DS HRS DF11-**SC or equivalent or equivalent Block Diagram fosc :70KHz +S ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P 38 Assignment AC/L AC/N FG LED CN100 SVR1 3.5 3.5 28.5 Pin No. 1 2 3 1 5 2 6 Terminal Pin No. Assignment RECTIFIERS & PFC POWER SWITCHING O.T.P. O.L.P. RECTIFIERS & FILTER Derating Curve -S DETECTION CIRCUIT FG PFC CONTROL +V -V O.V.P. PWM CONTROL Output Derating VS Input Voltage Ta = 25 100 125 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:HRP-200-SPEC 2010-05-12