P D - 11 0 110W Dual Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection With power good signal output(Optional) 100% full load burn-in test Fixed switching frequency at 45KHz 2 years warranty SPECIFICATION MODEL OUTPUT PD-110A PD-110B OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 5A 6.5A 5A 3.5A CURRENT RANGE 0.5 ~ 5A 0.5 ~ 6.5A 0.5 ~ 5A 0.5 ~ 3.5A RATED POWER 103W 109W RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p VOLTAGE ADJ. RANGE CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% INPUT 1.0% 2.0% LOAD REGULATION 1.0% 5.0% 1.0% 5.0% SETUP, RISE TIME 1200ms, 50ms at full load HOLD UP TIME (Typ.) 80ms at full load VOLTAGE RANGE 100 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 75% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3A/115VAC OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE 141 ~370VDC (90 ~ 100VAC 90% load max.) 78% 1.5A/230VAC COLD START 45A <1mA /240VAC 105% ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75VDC Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +50 ,60 with cooling fan (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A DIMENSION PACKING NOTE 6.0% 2.0% PROTECTION OTHERS 6.0% 200mVp-p 1.0% OVERLOAD (Note 4) CH1:4.75 ~ 5.5V 2.0% LINE REGULATION LEAKAGE CURRENT EMC 100mVp-p 323K hrs min. MIL-HDBK-217F (25 177.8*107.95*46.5mm (L*W*H) 0.51Kg; 24pcs/13.1Kg/1.19CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Heat Sink HS1,HS2 can not be shorted. File Name:PD-110-SPEC 2012-02-03 P D - 11 0 110W Dual Output Switching Power Supply Mechanical Specification series Unit:mm 177.8 165.1 6.35 6.35 AC FUSE T4A/250V FS1 CN1 HS1 107.95 12 11 10 9 8 7 6 5 4 3 2 1 95.25 5 4 3 2 1 AC Input Connector (CN1) : Molex 5273-05 or equivalent Assignment FG No Pin AC/N AC/L Pin No. 1 2,4 3 5 HS2 Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent CN2 DC Output Connector (CN2) : Molex 5273-12 or equivalent +5V ADJ 3.96 Pin No. 1,2,3 4,5,6,7 8,9,10 11,12 46.5 4- Assignment V1 COM V2 V3(Option) MODEL 2 max. Pin No. 1,2,3 8,9,10 Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent PD-110A PD-110B +5V +12V +5V +24V HS1,HS2 can not be shorted Block Diagram fosc : 45KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING FG O.L.P. RECTIFIERS & FILTER V2 RECTIFIERS & FILTER V1 COM DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Static Characteristics (A) OUTPUT VOLTAGE (V) 80 Natural convection cooling LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 13 5.2 12 5.0 11 4.8 10 4.6 9 4.4 8 4.2 7 4.0 300 +12V +5V 250 200 150 +12V 100 +5V 50 25 90 100 110 120 140 160 180 200 220 240 OUTPUT RIPPLE (mVp-p) 17CFM forced air cooling(20cm) 100 264 INPUT VOLTAGE (V) 60Hz File Name:PD-110-SPEC 2012-02-03