RPD-65 65W Dual Output Switching Power Supply series Features : Universal AC input/Full range 12V or 24V high peak output current capability Optional L-Bracket and cover (RPD-65x-C, x=C,D) Low leakage current<1mA Protections: Short circuit / Overload / Over voltage 60W free air convection, 77W with 18CFM forced air 100% full load burn-in test Fixed switching frequency at 65KHz 2 years warranty SPECIFICATION MODEL CH1 CH2 CH1 CH2 DC VOLTAGE 12V 5V 24V 5V RATED CURRENT 4.5A 1.2A 2.25A 1.2A CURRENT RANGE 0 ~ 5.8A 0 ~ 1.5A 0 ~ 2.9A 0 ~ 1.5A Rated load 3.75A Rated load PEAK LOAD OUTPUT RPD-65D RPD-65C OUTPUT NUMBER Note.4 7.5A RATED POWER 60W 60W OUTPUT POWER (max.) Rated output power for convection; 77W with 18CFM min. forced air RIPPLE & NOISE (max.) Note.2 120mVp-p 50mVp-p VOLTAGE ADJ. RANGE CH1:11.4 ~ 12.8V VOLTAGE TOLERANCE Note.3 2.0% INPUT 1.0% 1.0% LOAD REGULATION 2.0% 5.0% 2.0% 5.0% SETUP, RISE TIME 800ms, 20ms at full load HOLD UP TIME (Typ.) 20ms at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 440Hz EFFICIENCY (Typ.) 79% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE 127 ~370VDC 81% 0.9A/230VAC COLD START 25A/115VAC <1mA 50A/230VAC 90 ~ 125W output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. CH1:27.6 ~ 32.4V CH1:13.8 ~ 16.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed. -20 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 ) on CH1 output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A MTBF 288.1K hrs min. MIL-HDBK-217F (25 ) PCB:127*76*28mm (L*W*H) ; with optional CASE:130*85*37mm (L*W*H) PCB:0.24Kg; 63pcs/16Kg/1.35CUFT ; with optional CASE:0.47Kg;32pcs/16Kg/0.64CUFT DIMENSION PACKING NOTE 5.0% 1.0% PROTECTION OTHERS 50mVp-p 1.0% OVERLOAD (Note 5) CH1:22.8 ~ 26.4V 2.0% LINE REGULATION LEAKAGE CURRENT EMC 5.0% 150mVp-p 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 10% duty cycle maximum within every second. Average output power should not exceed the rated power, output voltage above 90% DC voltage. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:RPD-65-SPEC 2011-08-19 RPD-65 65W Dual Output Switching Power Supply Mechanical Specification Case No. 946A series Unit:mm Optional cover: No. 946A-T 127 115.8 5.6 5.6 64.8 6 5 4 3 2 1 FS1 1 2 3 SVR1 4- 18 CN1 7.1 3.8 2-M FAM 3 11 5 29mm(max) 85 6-M 3L 4-M .8 3L =4 8.2 78 41 13 0 62 68 26 17 AC Input Connector (CN1) : Molex 5273-03 or equivalent Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent =4 37 15cm 18CFM min. (60W convection, 77W with FAN) 3 max. 76 CN2 .7 .6 Optional L-Bracket: No. 946A-D DC Output Connector (CN2) : Molex 5273-06 or equivalent Pin No. 1,2 3,4 5 6 Assignment V1 GND V2 NC Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Block Diagram fosc : 65KHz I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V RECTIFIERS & FILTER FG O.L.P. PWM CONTROL +5V COM DETECTION CIRCUIT O.V.P. File Name:RPD-65-SPEC 2011-08-19 RPD-65 65W Dual Output Switching Power Supply Derating Curve Output Derating VS Input Voltage 100 100 PCB only 90 For PCB with L-Bracket+cover option 80 70 LOAD(%) LOAD (%) For both PCB only and with L-Bracket+cover option 80 60 40 20 -20 series -10 0 10 20 30 40 AMBIENT TEMPERATURE ( ) 50 60 (HORIZONTAL) 60 50 40 90 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:RPD-65-SPEC 2011-08-19