MEANWELL PD-110A

P D - 11 0
110W Dual Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
With power good signal output(Optional)
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
PD-110A
PD-110B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
5A
6.5A
5A
3.5A
CURRENT RANGE
0.5 ~ 5A
0.5 ~ 6.5A
0.5 ~ 5A
0.5 ~ 3.5A
RATED POWER
103W
109W
RIPPLE & NOISE (max.) Note.2 100mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
INPUT
200mVp-p
6.0%
1.0%
2.0%
1.0%
2.0%
LOAD REGULATION
1.0%
5.0%
1.0%
5.0%
SETUP, RISE TIME
1200ms, 50ms at full load
HOLD UP TIME (Typ.)
80ms at full load
VOLTAGE RANGE
100 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
75%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3A/115VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
CH1:4.75 ~ 5.5V
2.0%
LINE REGULATION
LEAKAGE CURRENT
OTHERS
6.0%
100mVp-p
141 ~370VDC (90 ~ 100VAC 90% load max.)
78%
1.5A/230VAC
COLD START 40A
<1mA /240VAC
105% ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75VDC
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +50 ,60 with cooling fan(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,11; ENV50204, light industry level, criteria A
323K hrs min. MIL-HDBK-217F (25 )
177.8*107.95*46mm (L*W*H)
0.51Kg; 24pcs/13.1Kg/1.19CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:PD-110-SPEC 2008-03-25
P D - 11 0
110W Dual Output Switching Power Supply
Mechanical Specification
series
Unit:mm
177.8
165.1
6.35
6.35
T4A/250V
CN1
95.25
12
11
10
9
8
7
6
5
4
3
2
1
107.95
5
4
3
2
1
AC Input Connector (CN1) : Molex 5273-05 or equivalent
Assignment
FG
No Pin
AC/N
AC/L
Pin No.
1
2,4
3
5
Mating Housing
Terminal
Molex 5195
or equivalent
Molex 5194
or equivalent
CN2
DC Output Connector (CN2) : Molex 5273-12 or equivalent
+5V ADJ
3.96
Pin No.
1,2,3
4,5,6,7
8,9,10
11,12
Assignment
V1
COM
V2
V3(Option)
MODEL
46
4-
Pin No.
1,2,3
8,9,10
Mating Housing
Terminal
Molex 5195
or equivalent
Molex 5194
or equivalent
PD-110A PD-110B
+5V
+24V
2 max.
+5V
+12V
Block Diagram
fosc : 45KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
FG
O.L.P.
RECTIFIERS
&
FILTER
V2
RECTIFIERS
&
FILTER
V1
COM
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics (A)
Ta=25
OUTPUT VOLTAGE (V)
100
80
Natural convection cooling
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
13
5.2
12
5.0
11
4.8
10
4.6
9
4.4
8
4.2
7
4.0
300
+12V
+5V
250
200
150
+12V
100
+5V
50
25
90
100
110
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
17CFM forced air cooling(20cm)
260
INPUT VOLTAGE (V) 60Hz
File Name:PD-110-SPEC 2008-03-25