R P T- 6 0 60W Triple Output Medical Type series Features : 4" 2" miniature size Universal AC input / Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Cooling by free air convection ANSI/AAMI ES60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty SPECIFICATION MODEL OUTPUT INPUT CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 4A 2A 0.5A 4A 2A 0.5A 4A 1.5A 0.5A CURRENT RANGE 0.5 ~ 4.4A 0.1 ~ 2.2A 0.1 ~ 0.55A 0.5 ~ 4.4A 0.1 ~ 2.2A 0.1 ~ 0.55A 0.5 ~ 4.4A 0.1 ~ 1.65A 0.1 ~ 0.55A RATED POWER 46.5W 100mVp-p 150mVp-p PEAK LOAD(10sec.) 50W 50W 55W Note.4 51.15W 80mVp-p 80mVp-p 80mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% 6.0% +9,-8% LINE REGULATION 0.5% 1.0% LOAD REGULATION 1.5% 2.0% RIPPLE & NOISE (max.) Note.2 80mVp-p 55W 80mVp-p 100mVp-p 80mVp-p +3,-2% 6.0% +10,-6% +3,-2% 6.0% 8.0% 1.0% 0.5% 1.0% 2.0% 0.5% 2.0% 2.0% +5,-7% 1.5% 2.0% 5.0% 1.5% 3.0% 4.0% SETUP, RISE TIME 200ms, 15ms/230VAC HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 77% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC COLD START 60A/230VAC LEAKAGE CURRENT For earth <200uA/264VAC, For patient <100uA/264VAC OVERLOAD 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 5) EMC EMISSION 200ms, 15ms/115VAC at full load 15ms/115VAC at full load 127 ~ 370VDC 78% 79% 0.7A/230VAC 30A/115VAC Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A MTBF 677.8Khrs min. DIMENSION 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT PACKING NOTE RPT-60C CH1 PROTECTION OTHERS RPT-60B RPT-60A OUTPUT NUMBER MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Heat Sink HS1,HS2 can not be shorted. File Name:RPT-60-SPEC 2012-01-09 R P T- 6 0 60W Triple Output Medical Type series Features : 4" 2" miniature size Universal AC input / Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Cooling by free air convection ANSI/AAMI ES60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty SPECIFICATION MODEL OUTPUT INPUT CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 24V 12V 3.3V 5V 12V RATED CURRENT 3.5A 1A 0.5A 5A 3A 0.7A CURRENT RANGE 0.5 ~ 3.85A 0.1 ~ 1.1A 0.1 ~ 0.55A 0.5 ~ 5.5A 0.3 ~ 3.3A 0.1 ~ 0.77A RATED POWER 47.5W PEAK LOAD(10sec.) 43.89W Note.4 52.25W 80mVp-p 80mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% 6.0% 8.0% +3,-2% 8.0% +10,-6% LINE REGULATION 0.5% 2.0% 2.0% 0.5% 1.0% 2.0% LOAD REGULATION 1.5% 3.0% 4.0% 1.5% 2.0% +5.5,-5% 150mVp-p 80mVp-p 80mVp-p SETUP, RISE TIME 200ms, 15ms/230VAC HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 79% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC COLD START 60A/230VAC LEAKAGE CURRENT For earth <200uA/264VAC, For patient <100uA/264VAC OVERLOAD 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 5) EMC EMISSION -20 ~ +65 200ms, 15ms/115VAC at full load 15ms/115VAC at full load 127 ~ 370VDC 75% 0.7A/230VAC 30A/115VAC CH1: 3.8 ~ 4.45V (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A DIMENSION 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT PACKING NOTE 39.9W RIPPLE & NOISE (max.) Note.2 80mVp-p PROTECTION OTHERS RPT-6003 RPT-60D OUTPUT NUMBER 677.8Khrs min. MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Heat Sink HS1,HS2 can not be shorted. File Name:RPT-60-SPEC 2012-01-09 R P T- 6 0 60W Triple Output Medical Type Mechanical Specification series Unit:mm 101.6 3.175 95.25 50.8 44.45 FS1 3.175 AC FUSE T2.5/250V 3 2 1 CN1 HS2 1 2 3 4 5 6 FS2 AC FUSE T2.5/250V CN2 HS1 3.3 3 max. 29 4- DC Output Connector (CN2) : JST B6P-VH or equivalent AC Input Connector (CN1) : JST B3P-VH or equivalent Assignment AC/N No Pin AC/L Pin No. 1 2 3 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1,2 3,4 5 6 HS1,HS2 can not be shorted Assignment V1 COM V2 V3 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING V3 RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. fosc : 100KHz RECTIFIERS & FILTER CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 65 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RPT-60-SPEC 2012-01-09